Product Overview The Schneider Electric MVS08N Circuit Breaker is part of the EasyPact MVS low-voltage air circuit breaker family. Designed for electrical power distribution applications, this circuit b……
Schneider MVS08N Circuit Breaker
  • Schneider
  • MVS08N
  • Circuit Breaker
  • France
  • 352 x 422 x 297 mm
  • 40 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 8

Our advantage

Schneider MVS08N Circuit Breaker

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Schneider MVS08N Circuit Breaker

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Schneider MVS08N Circuit Breaker

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Schneider MVS08N Circuit Breaker

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Schneider Electric MVS08N Circuit Breaker is part of the EasyPact MVS low-voltage air circuit breaker family. Designed for electrical power distribution applications, this circuit breaker helps protect electrical installations against overloads and short circuits while providing a means of switching and isolating circuits for maintenance.

Air circuit breakers are commonly used in main distribution panels, industrial switchboards, and large electrical installations where high current ratings and coordinated protection are required. They help disconnect a circuit when monitored electrical conditions exceed configured protection limits, reducing the risk of equipment damage and supporting the safe operation of a distribution system.

The MVS08N family includes 800 A circuit breaker configurations. Depending on the complete catalog number, the device may be supplied with different operating mechanisms, mounting arrangements, and electronic trip units. These options influence how the breaker is operated, installed, and coordinated with other protective devices.

The relevant 800 A product configurations are designed for AC networks operating at up to 690 V and 50/60 Hz. A documented three-pole version has a 50 kA breaking-capacity code and supports isolation in accordance with IEC 60947-2, subject to the specific product configuration and operating voltage.

The MVS08N is intended for use in engineered electrical distribution systems. It is not a substitute for a correctly designed protection scheme: current ratings, fault levels, cable sizes, upstream and downstream protection, and installation conditions must all be evaluated before selection.

Because the designation MVS08N does not identify every configuration detail, buyers should confirm the full catalog number printed on the breaker nameplate before ordering a replacement.

Technical Specifications

Parameter Specification
Brand Schneider Electric
Product Family EasyPact MVS
Model MVS08N
Product Type Low-Voltage Air Circuit Breaker
Application Electrical Power Distribution
Rated Current 800 A
Poles Commonly available in 3-pole and 4-pole versions
Network Type AC
Rated Operational Voltage Up to 690 V AC, 50/60 Hz
Breaking Capacity Code N
Documented Breaking Capacity 50 kA at 220–440 V AC for relevant configurations
Rated Insulation Voltage 1000 V AC
Rated Impulse Withstand Voltage 12 kV
Trip Unit Depends on the complete catalog number
Operating Mechanism Manual or electrical, depending on configuration
Mounting Fixed or drawout, depending on configuration
Isolation Suitability Yes, subject to applicable product configuration
Dimensions Provided 352 × 422 × 297 mm
Weight Provided 40 kg
Applicable Standard IEC 60947-2
Typical Installation Main distribution panels and industrial switchboards

Important: MVS08N is a family designation rather than a complete configuration-specific catalog number. Confirm the exact suffix, pole count, trip unit, operating mechanism, mounting type, and electrical ratings before installation or replacement.

Function and Working Principle

The MVS08N circuit breaker is designed to carry normal operating current and interrupt a circuit when a fault condition requires disconnection. Its operation combines switching contacts, an arc-interruption system, and a protection mechanism selected for the particular configuration.

1. Normal Current-Carrying Operation

During normal operation, the breaker’s contacts remain closed, allowing current to flow through the distribution circuit to connected loads.

The 800 A rating identifies the nominal current class of the relevant MVS08N configurations. The actual permissible operating current must also account for ambient temperature, installation conditions, conductor ratings, and the manufacturer’s requirements.

2. Overload Protection

An overload occurs when a circuit carries more current than intended for a sustained period. Depending on the installed trip unit, the breaker can monitor current and initiate a trip when the configured long-time protection threshold and delay are exceeded.

This time-dependent behavior helps distinguish sustained overloads from brief current variations associated with normal equipment operation.

The exact adjustment ranges and protection functions depend on the installed trip unit. Settings must be selected according to the electrical system study and the requirements of the protected equipment.

3. Short-Circuit Protection

A short circuit can produce a very high current over a short period. The circuit breaker must detect the fault and interrupt the current within its rated operating limits.

The MVS08N family includes configurations with a 50 kA breaking-capacity code. For the specific installation, engineers must verify the available prospective short-circuit current and the breaker’s applicable breaking capacity at the actual system voltage.

A 50 kA rating at one voltage should not be assumed to apply unchanged at every operating voltage or in every configuration.

4. Electronic Trip Unit Operation

Depending on the selected model, the breaker may use an electronic trip unit with adjustable protection functions. Such units can provide different combinations of long-time, short-time, instantaneous, and earth-fault protection.

The functions available on a particular breaker depend on its installed trip unit and configuration. A replacement breaker must therefore be checked for protection functions and adjustment ranges, not just its 800 A current rating.

5. Arc Interruption

When the breaker opens under load or fault conditions, an electrical arc can form between the separating contacts. The breaker’s arc-control and interruption system is designed to extinguish this arc and interrupt current safely within the rated conditions.

Correct installation, maintenance, and selection according to the applicable fault level are essential for reliable interruption performance.

Role in Industrial Electrical Distribution Systems

The Schneider Electric MVS08N circuit breaker can serve as a main or feeder protection device in a low-voltage distribution system, depending on the installation design.

Main Distribution Protection

In an industrial main switchboard, a suitably rated air circuit breaker can protect an incoming supply or a major distribution section. It provides a controlled means of connecting and disconnecting the circuit while supporting protection against abnormal current conditions.

The selection process must consider the available fault current, system voltage, load profile, and coordination with upstream protection.

Feeder Protection

The breaker may also be used to protect a large outgoing feeder supplying a sub-distribution panel or substantial electrical load.

In this role, the protection settings must be coordinated with downstream breakers so that a fault is isolated as selectively as practical. Correct coordination can help limit unnecessary interruption to unaffected parts of the facility.

Electrical Isolation

The relevant MVS08N configurations are suitable for isolation under the applicable standard. Isolation procedures must still follow the equipment’s operating instructions and the site’s electrical safety rules.

For maintenance, personnel should verify the isolation state, apply lockout/tagout procedures, and confirm the absence of hazardous voltage before working on the circuit.

Integration with Monitoring Systems

Depending on the installed accessories and operating mechanism, a breaker installation may support remote operation, auxiliary status indication, or integration with an electrical monitoring system.

These functions should not be assumed from the MVS08N family name alone. Check the complete catalog number and accessory list to establish which monitoring or remote-control functions are available.

Industrial Applications

1. Industrial Main Switchboards

Manufacturing facilities use main switchboards to distribute power to production lines, utilities, and building services. An appropriately configured MVS08N breaker can provide protection and switching for a distribution section rated for its electrical characteristics.

The installation must be designed for the actual load current and prospective short-circuit current.

2. Factory Power Distribution

Factories often supply large groups of machines, motors, heaters, and auxiliary equipment from centralized electrical distribution panels. An 800 A air circuit breaker may be suitable for a feeder or distribution section where its ratings and protection characteristics match the design.

The breaker should be selected as part of a coordinated protection system rather than as an isolated component.

3. Commercial and Industrial Buildings

Large commercial buildings and industrial facilities may use air circuit breakers in major distribution assemblies. They can support controlled switching and fault protection for high-current circuits.

Environmental conditions, enclosure requirements, maintenance access, and the system’s fault level must be reviewed during design.

4. Utility and Infrastructure Facilities

Infrastructure installations such as water treatment facilities, transport facilities, and utility support buildings may require robust low-voltage distribution protection.

A suitable MVS08N configuration can be considered when the electrical ratings, protection functions, and installation arrangement meet the requirements of the specific project.

5. Electrical Panel Replacement Projects

The MVS08N may be encountered in maintenance and refurbishment work involving existing EasyPact MVS installations. In these projects, identifying the complete catalog number is particularly important.

Replacing a breaker with a different trip unit, mounting arrangement, or operating mechanism can affect protection coordination, wiring, mechanical fit, and commissioning requirements.

Installation and System Integration

Air circuit breakers are high-energy electrical devices. Installation, commissioning, and servicing should be performed by qualified personnel using the applicable manufacturer instructions and electrical safety procedures.

1. Verify the Full Catalog Number

Before installation, check the complete catalog number on the nameplate. Confirm the current rating, pole count, voltage rating, breaking capacity, trip unit, mounting type, and operating mechanism.

The MVS08N family includes multiple configurations, so the base designation alone is insufficient for a guaranteed like-for-like replacement.

2. Check System Fault Levels

Determine the prospective short-circuit current at the point where the breaker will be installed. Verify that the breaker’s rated breaking capacity is adequate for the system voltage and the calculated fault level.

Protection coordination with upstream and downstream devices should be evaluated before the breaker is commissioned.

3. Confirm Mounting and Dimensions

The supplied dimensions are 352 × 422 × 297 mm, and the supplied weight is 40 kg. Confirm the dimensional drawing for the exact breaker configuration, including any chassis or operating accessories.

Allow adequate space for installation, operation, inspection, and maintenance. For drawout models, check the chassis arrangement and the space required for insertion, withdrawal, and access.

Because the breaker is heavy, use an appropriate handling and lifting procedure. Do not rely on the front panel or operating handle as a lifting point.

4. Inspect Electrical Connections

Check the busbar or cable connection arrangement and ensure that conductors, terminals, and connection hardware are suitable for the intended current and installation conditions.

Follow the manufacturer’s specified tightening procedures and torque values. Poor electrical connections can cause overheating and damage even when the nominal current rating appears suitable.

5. Configure the Trip Unit

If the installed breaker has an adjustable electronic trip unit, set its protection parameters according to the protection study and the characteristics of the downstream circuit.

Do not copy settings from another breaker without verifying the cable ratings, load characteristics, fault levels, and coordination requirements. Record the final settings as part of the commissioning documentation.

6. Test Operation and Protection

Before placing the breaker into service, perform the required inspections and functional tests in accordance with the manufacturer’s instructions and the applicable commissioning procedure.

Verify mechanical operation, auxiliary contacts where fitted, electrical operating functions where applicable, and trip-unit operation using approved testing methods. Confirm that all protection settings are documented and reviewed by the responsible electrical engineer.

7. Establish a Maintenance Schedule

Maintenance intervals should reflect the manufacturer’s recommendations, operating environment, switching duty, and fault history.

Inspection may include contact and mechanism condition, terminal connections, insulation condition, trip-unit testing, and the condition of any fitted accessories. Any abnormal wear, overheating, or mechanical damage should be assessed before the breaker returns to service.

Compatible System Components

The MVS08N is part of a larger electrical distribution assembly. The components used with it depend on the complete breaker configuration and the design of the switchboard.

Component Function Compatibility Considerations
Main busbars Distribute electrical power through the switchboard Verify current capacity, spacing, and connection arrangement
Incoming supply conductors Carry power into the distribution assembly Size according to current, installation method, and applicable standards
Downstream circuit breakers Protect outgoing feeders and loads Coordinate trip settings and breaking capacities
Electronic trip unit Detect abnormal current and initiate tripping Confirm the exact trip-unit type and protection functions
Operating mechanism Provides manual or electrical operation Depends on the full breaker catalog number
Auxiliary contacts Provide status or control signals where fitted Confirm contact configuration and accessory compatibility
Shunt trip or undervoltage release Supports specified remote-trip or undervoltage functions Verify availability, voltage, and accessory compatibility
Drawout chassis Supports insertion and withdrawal of compatible breakers Required only for applicable drawout configurations
Switchboard enclosure Provides mechanical protection and segregation Verify dimensions, clearances, and assembly requirements
Protection coordination study Establishes suitable settings and selectivity Base settings on the actual system and installed trip unit

These components are examples of a typical distribution system. They are not necessarily included with every MVS08N breaker.

Alternative Models and Replacement Considerations

When replacing an MVS08N breaker, selecting another 800 A breaker is only the first step. The replacement must also meet the installation’s voltage, fault-level, mounting, operating, and protection requirements.

Replacement Option Considerations
Same complete MVS08N catalog number Preferred starting point for like-for-like replacement, subject to condition and configuration verification
Another MVS08N configuration May differ in pole count, trip unit, mounting, or operating mechanism
A different EasyPact MVS rating Requires confirmation of current rating, dimensions, connection layout, and protection requirements
Another Schneider Electric air circuit breaker family Requires detailed electrical and mechanical compatibility assessment
A modern equivalent from another manufacturer May require switchboard modifications, new connection hardware, protection-setting changes, and recommissioning

Before approving a replacement, verify:

  • Rated current and operating voltage.
  • Number of poles and protected poles.
  • Rated ultimate and service breaking capacities.
  • Short-time withstand capability where applicable.
  • Trip-unit type and protection functions.
  • Fixed or drawout mounting arrangement.
  • Manual or electrical operating mechanism.
  • Auxiliary contacts and control accessories.
  • Terminal and busbar connection dimensions.
  • Overall dimensions and installation clearances.
  • Protection coordination with upstream and downstream devices.

A breaker should not be replaced solely on the basis of its current rating or physical appearance. Any substitution must be evaluated by qualified electrical personnel.

Key Advantages

High-Current Distribution Capability

The relevant MVS08N configurations are rated at 800 A, making them suitable for appropriately designed high-current low-voltage distribution applications.

High Breaking Capacity for Applicable Configurations

A documented configuration provides a 50 kA breaking capacity at 220–440 V AC. The actual permissible fault level must be verified against the specific breaker rating and system voltage.

Electronic Protection Options

Depending on the configuration, the breaker can be equipped with electronic trip units offering adjustable protection functions.

Fixed and Drawout Configurations

The family includes different mounting arrangements. This allows selection according to the switchboard design and maintenance requirements, although the exact arrangement is identified by the complete catalog number.

Manual or Electrical Operation

Different configurations support different operating methods. Electrical operation may be useful where remote or automated switching is required and the appropriate mechanism and accessories are installed.

Industrial Distribution Applications

The EasyPact MVS family is designed for low-voltage power distribution. Correctly selected and maintained breakers can support reliable electrical protection in industrial and commercial facilities.

Technical FAQs

1. What is the Schneider Electric MVS08N?

MVS08N is a model designation within Schneider Electric’s EasyPact MVS air circuit breaker family. It identifies an 800 A class of low-voltage circuit breaker, but the full catalog number is needed to determine the exact configuration.

2. What is the rated current of the MVS08N?

The relevant MVS08N configuration is rated at 800 A. The permitted operating current must also be assessed against installation conditions and the applicable product documentation.

3. What voltage does the MVS08N support?

Documented configurations are rated for AC systems up to 690 V at 50/60 Hz. Verify the exact breaker and installation requirements before use.

4. What is its breaking capacity?

The breaking-capacity code N corresponds to configurations documented with 50 kA at 220–440 V AC. Breaking capacity can vary with operating voltage and the specific configuration, so the nameplate and technical documentation must be checked.

5. Is the MVS08N a fixed or drawout breaker?

Both fixed and drawout configurations exist within the MVS08N family. The complete catalog number determines which version is supplied.

6. Does it use an electronic trip unit?

Many MVS08N configurations use electronic trip units. The exact trip-unit model and its available protection functions depend on the full catalog number.

7. Can the MVS08N be operated remotely?

Some configurations can be equipped for electrical operation and may support additional control accessories. Remote operation should only be assumed after verifying the operating mechanism and the installed accessories.

8. Can I replace an existing MVS08N with another 800 A breaker?

Not automatically. The replacement must match the required electrical ratings, fault-interruption capability, pole count, trip functions, mounting arrangement, and connection layout. A qualified electrical engineer should review any substitution.

9. What are the dimensions and weight?

The supplied listing values are 352 × 422 × 297 mm and 40 kg. Verify the exact configuration and manufacturer’s dimensional drawing before using these figures for panel design or transportation.

10. What should I check before purchasing a used MVS08N?

Check the complete catalog number, nameplate ratings, trip-unit type, mechanical condition, terminals, operating mechanism, and available testing records. Confirm whether any required chassis, operating accessories, or auxiliary components are included.

Procurement and Maintenance Recommendations

When purchasing a Schneider Electric MVS08N circuit breaker, start by identifying the full catalog number. The base model designation does not establish every detail required for a safe and compatible installation.

For replacement projects, compare the existing breaker with the proposed unit, including rated current, system voltage, breaking capacity, trip unit, pole count, operating mechanism, mounting arrangement, and connection dimensions.

For used or refurbished equipment, request clear photographs of the nameplate and terminals, information about the unit’s operating history where available, and evidence of appropriate inspection or functional testing. Confirm the condition of any supplied accessories and establish the applicable warranty and return terms.

During maintenance, follow the manufacturer’s instructions and site electrical safety procedures. Keep a record of protection settings, inspection findings, functional tests, and any component replacements. If a breaker has interrupted a significant fault, assess its condition according to the manufacturer’s requirements before returning it to service.

Because this is a high-current protective device, installation, protection-setting changes, and commissioning should be handled by qualified electrical personnel. Proper system coordination is essential to ensure that the breaker operates as intended and that faults are isolated without unnecessary disruption to the wider installation.

Conclusion

The Schneider Electric MVS08N EasyPact MVS circuit breaker is an 800 A class low-voltage air circuit breaker designed for electrical distribution and protection applications. Relevant configurations support operation at up to 690 V AC and include a 50 kA breaking-capacity rating at specified lower operating voltages.

Its suitability for a particular installation depends on the complete catalog number, trip-unit configuration, mounting arrangement, operating mechanism, and system fault level. For procurement and replacement work, verifying these details is essential for safe integration, reliable protection, and long-term electrical system performance.