• Foxboro RH916UH I/A Series Base-to-Base Cable
  • Foxboro RH916UH I/A Series Base-to-Base Cable
  • Foxboro RH916UH I/A Series Base-to-Base Cable
  • Foxboro RH916UH I/A Series Base-to-Base Cable
Product Overview The Foxboro RH916UH I/A Series Base-to-Base Cable is a 20-meter cable identified for base-to-base connections in compatible Foxboro I/A Series distributed control systems. It belongs to……
Foxboro RH916UH I/A Series Base-to-Base Cable
  • Foxboro
  • RH916UH
  • Base-to-Base Cable
  • USA
  • 20 meters
  • 3 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 6

Our advantage

Foxboro RH916UH I/A Series Base-to-Base Cable

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Foxboro RH916UH I/A Series Base-to-Base Cable

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Foxboro RH916UH I/A Series Base-to-Base Cable

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Foxboro RH916UH I/A Series Base-to-Base Cable

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Foxboro RH916UH I/A Series Base-to-Base Cable is a 20-meter cable identified for base-to-base connections in compatible Foxboro I/A Series distributed control systems. It belongs to the cabling infrastructure used to interconnect designated control-system hardware and maintain the communication paths required by the installed architecture.

In modular DCS installations, baseplates accommodate control and fieldbus modules, while dedicated communication cables connect compatible interfaces. The correct cable type is essential because base-to-base cables, module fieldbus cables, and HDLC cables may serve different connection functions even when they belong to the same product family.

The RH916UH is relevant to maintenance teams working on existing I/A Series installations where the designated base-to-base cable requires replacement. Before installation, engineers should confirm the complete part number, connected baseplate interfaces, connector arrangement, and specified cable construction. Cable length alone is not sufficient to establish compatibility.

Correct identification is particularly important when working with legacy control systems, where similar-looking cable assemblies may have different interface assignments. Matching the replacement to the existing hardware configuration helps avoid incorrect connections and unnecessary communication troubleshooting.


Technical Specifications

Parameter Specification
Manufacturer Foxboro
Product Type I/A Series Base-to-Base Cable
Model RH916UH
Product Family Foxboro I/A Series
Cable Category Base-to-Base Cable
Cable Length 20 meters
Typical Application Base-to-base connections in compatible I/A Series installations
Shipping Weight 3 kg

Product Features

  • 20-meter cable length: Supports installations requiring the specified connection distance between compatible interfaces.
  • Base-to-base connection: Identifies the cable’s intended role in the modular control-system architecture.
  • I/A Series application: Supports compatible Foxboro control-system installations.
  • Dedicated cable function: Helps distinguish the product from module fieldbus and other communication cable types.
  • Maintenance replacement: Supports service work where RH916UH is the designated replacement part.
  • Part-number identification: Helps engineers match replacement cabling to the installed configuration.
  • Installation-specific compatibility: Requires verification of the connected hardware and interface requirements.

Working Principle

The RH916UH provides the physical cable connection between designated baseplate interfaces in a compatible Foxboro I/A Series control system. It carries the electrical signals required by the intended connection, while the connected hardware performs communication handling and control functions.

A modular control system uses baseplates to accommodate control and fieldbus modules. Depending on the architecture, base-to-base connections form part of the interconnection arrangement between designated hardware assemblies. The cable itself is passive: it does not execute control logic, process field measurements, or independently manage network traffic.

A simplified system arrangement is:

Field Devices → Field Wiring → Termination Assemblies → Fieldbus Modules → Baseplate Interfaces → Base-to-Base Connection → Control-System Hardware

The precise role of the RH916UH depends on the installed I/A Series architecture and the interfaces specified for the cable. It should not be treated as interchangeable with an HDLC cable or a module fieldbus cable without confirming the connection requirements.

The 20-meter length is relevant where the system design calls for that cable run. During installation, engineers should ensure that the routing follows the approved cabinet or equipment layout and does not introduce excessive tension, sharp bends, or mechanical damage.

If communication or module operation is affected after cable replacement, inspect the connectors and connected interfaces first. If the cable is correctly installed, check the baseplates, associated modules, and system diagnostics to determine whether another component is responsible for the fault.


Role in the Foxboro I/A Series Control Architecture

The RH916UH supports the designated base-to-base connection within compatible Foxboro I/A Series installations. It forms part of the physical interconnection infrastructure that links the relevant hardware interfaces.

Field Devices → Field Wiring → Termination Assemblies → Fieldbus Modules → Baseplates → RH916UH Cable Connection → Control-System Infrastructure

System Component Function
RH916UH Cable Provides the designated base-to-base cable connection
Modular Baseplates Accommodate compatible modules and provide hardware interfaces
Fieldbus Modules Handle configured process input and output functions
Termination Assemblies Connect field wiring to the associated module interfaces
Field Devices Measure process variables or receive control commands
Control Processors Execute configured control strategies
Communication Infrastructure Supports information exchange between compatible system components
Engineering and Diagnostic Tools Support configuration checks and fault investigation

The RH916UH is a passive cabling component. Its function depends on the connected baseplates, compatible interfaces, and the installed control-system design.


Industrial Applications

Application Typical Use
Distributed Control Systems Maintaining base-to-base cabling in compatible I/A Series installations
Process Automation Supporting designated connections between modular control assemblies
Chemical Processing Maintaining control-system infrastructure in process-control facilities
Oil and Gas Facilities Supporting legacy Foxboro DCS maintenance
Power Generation Maintaining compatible plant automation connections
Industrial Manufacturing Supporting modular control-system interconnections
Plant Maintenance Replacing a damaged base-to-base cable
Control Cabinet Refurbishment Restoring designated hardware connections during scheduled maintenance
Legacy DCS Support Maintaining existing installations that specify the RH916UH
Control-System Expansion Supporting additional connections where permitted by the installed architecture

Application suitability depends on the actual baseplate interfaces and system configuration. Engineers should verify the specified connection before ordering or installing a replacement cable.


Installation and Maintenance

  1. Verify the part number: Confirm that RH916UH is the cable specified for the intended base-to-base connection.
  2. Identify the connected baseplates: Check the installed hardware models and confirm that their interfaces match the cable requirements.
  3. Review system drawings: Verify the connection points and cable routing before removing the existing cable.
  4. Follow site safety procedures: Apply the required isolation and maintenance procedures before accessing control-system hardware.
  5. Inspect the cable jacket: Look for cuts, abrasion, crushing, cracking, or other visible damage.
  6. Check the connectors: Examine the connector housings and contacts for contamination, deformation, or mechanical damage.
  7. Confirm interface compatibility: Ensure that both ends are intended for the designated baseplate connections.
  8. Secure both ends: Fully seat the connectors and secure them according to the applicable equipment instructions.
  9. Route the cable carefully: Avoid sharp bends, excessive tension, crushing, and contact with sharp cabinet edges.
  10. Maintain suitable cable routing: Follow the established installation layout and prevent interference with other wiring or moving components.
  11. Verify system operation: After installation, check the connected hardware status and relevant system diagnostics.
  12. Document the replacement: Record the installed part number, connection points, and verification results in the maintenance records.

If the expected communication function is not restored, inspect the connection points and associated hardware before replacing additional components. Use the system diagnostics to help isolate the source of the fault.


Compatible System Components

The RH916UH is intended for base-to-base connections within compatible Foxboro I/A Series configurations. Related hardware should be selected according to the connection function specified in the installed system design.

Component Function
Foxboro I/A Series Modular Baseplates Provide interfaces for compatible control and fieldbus modules
Foxboro Fieldbus Modules Interface with field devices and process signals
Foxboro Control Processors Execute configured control logic
Compatible Baseplate Interfaces Provide the designated connection points for the cable
Termination Assemblies Connect field wiring to appropriate fieldbus module interfaces
Control-System Communication Hardware Supports information exchange within the installed architecture
Control-System Power Supplies Supply compatible control hardware
Engineering and Diagnostic Tools Support configuration verification and troubleshooting

Recommended Related Models

Model Product Type Relevance
Foxboro P0916UH I/A Series HDLC Cable Related cable designation; verify its interface before selection
Foxboro P0916NA I/A Series Cable Related I/A Series cable model with a different designated connection function
Foxboro P0916NB I/A Series Module Fieldbus Cable Module fieldbus cable for a different connection purpose
Foxboro RH916NA I/A Series Module Fieldbus Cable Related cable family member for module fieldbus connections
Foxboro RH916NB I/A Series Module Fieldbus Cable Related module fieldbus cable with a shorter specified length
Foxboro RH916MZ I/A Series Baseplate-to-Baseplate Cable Related cable designation for baseplate interconnection applications

Key Advantages

  • Provides a dedicated 20-meter cable option for the specified base-to-base connection.
  • Supports maintenance of compatible Foxboro I/A Series control-system infrastructure.
  • Helps restore designated hardware connections during cable replacement.
  • Makes it easier to identify the required component through its specific model number.
  • Supports maintenance planning for existing modular DCS installations.

Technical FAQs

What is the main function of the RH916UH?

The RH916UH is identified as an I/A Series base-to-base cable. Its intended function is to provide the physical connection between compatible baseplate interfaces specified by the installed control-system design.

Can the RH916UH replace the P0916UH HDLC cable?

Do not assume that the two cables are interchangeable. Their product designations indicate different cable categories, and compatibility depends on the intended interfaces and system documentation. Verify the original part number and connection requirements before substitution.

When should a 20-meter base-to-base cable be selected?

Use the 20-meter version when that length is specified for the intended connection and the cable is compatible with both interfaces. Confirm the routing requirements and connector arrangement rather than selecting a replacement based only on length.

What should be checked if the system connection fails after installation?

Check that the correct cable is installed between the designated baseplate interfaces, inspect both connectors, and review the status of the connected hardware. If the connection is intact, use system diagnostics to investigate possible baseplate or communication-interface faults.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501