The Foxboro RH916NC I/A Series Module Fieldbus Cable is a 3-meter cable used to connect compatible Fieldbus Modules (FBMs) to their associated termination assemblies in Foxboro I/A Series distributed control systems. It belongs to the module fieldbus cabling family used to establish the physical connection between control-system I/O hardware and field termination equipment.
In a modular DCS installation, FBMs process field signals and exchange information with the control system, while termination assemblies provide the connection between module interfaces and field wiring. The RH916NC supports this arrangement by providing the required cable connection for compatible hardware configurations.
The RH916NC is the LSZH cable version associated with the earlier P0916NC designation. The corresponding LSZH part number P0928BQ is also listed in Foxboro module fieldbus cable documentation. These designations should be distinguished when checking replacement requirements because cable construction, environmental characteristics, and system compatibility may vary between versions.
The cable is relevant to maintenance work involving existing I/A Series installations, particularly when a damaged connection must be replaced or an established FBM-to-termination assembly connection must be restored. Before installation, engineers should verify the cable type, connector arrangement, module configuration, and termination assembly requirements against the actual system documentation.
| Parameter | Specification |
|---|---|
| Manufacturer | Foxboro |
| Product Type | I/A Series Module Fieldbus Cable |
| Model | RH916NC |
| Product Family | Foxboro I/A Series |
| Cable Category | Module Fieldbus Cable |
| Cable Length | 3 meters |
| Cable Construction | LSZH (Low Smoke Zero Halogen) |
| Previous Part Number | P0916NC |
| Associated LSZH Part Number | P0928BQ |
| Typical Application | Connection between compatible FBMs and termination assemblies |
| Shipping Weight | 3 kg |
The RH916NC provides the physical cable connection required for a compatible Foxboro I/A Series fieldbus module and termination assembly arrangement. It carries the relevant electrical signals between the connected interfaces; the cable itself does not perform signal conversion, execute control logic, or process field measurements.
A typical field I/O connection follows this general path:
Field Device → Field Wiring → Termination Assembly → RH916NC Cable → Fieldbus Module → Control System
For input applications, field signals pass through the field wiring and termination assembly to the appropriate FBM channels. The FBM processes the incoming signals according to its specific function and makes the resulting data available to the control system. For output applications, the signal path operates in the opposite direction, allowing the control system to send commands to compatible field equipment.
The precise electrical arrangement depends on the FBM model, termination assembly, and installed system configuration. The RH916NC must therefore be selected for the intended module-to-termination connection rather than treated as a universal cable for every I/A Series interface.
Cable construction also matters. LSZH refers to low-smoke, zero-halogen material characteristics. Compared with conventional halogen-containing cable jackets, LSZH materials are intended to limit smoke and halogen emissions under specified fire conditions. This classification does not, by itself, establish the cable’s electrical rating, connector compatibility, or suitability for every installation environment.
When communication or field I/O faults occur, technicians should inspect the cable, connector seating, termination assembly, and module status. A damaged or incorrectly connected cable can interrupt the signal path, but similar symptoms may also result from faulty field wiring, a defective termination assembly, or a problem within the FBM.
The RH916NC supports the field I/O connection between compatible FBMs and termination assemblies in the Foxboro I/A Series architecture. It provides the physical link needed to transfer field signals between the termination hardware and the associated module.
Field Devices → Field Wiring → Termination Assembly → RH916NC → FBM → Control Processor
| System Component | Function |
|---|---|
| RH916NC Cable | Connects compatible fieldbus modules and termination assemblies |
| Fieldbus Module | Interfaces with field signals and performs the module-specific I/O function |
| Termination Assembly | Provides the connection between field wiring and the associated module interface |
| Field Devices | Generate process measurements or receive control commands |
| Field Wiring | Carries electrical signals between field devices and termination hardware |
| Control Processor | Executes control strategies and processes system data |
| System Communication Infrastructure | Transfers information between control-system components |
| Engineering and Diagnostic Tools | Support configuration checks and troubleshooting |
The cable does not replace the termination assembly or FBM. Correct operation depends on the compatibility and condition of all components in the field I/O path.
| Application | Typical Use |
|---|---|
| Distributed Control Systems | Connecting compatible FBMs to termination assemblies |
| Process Automation | Maintaining field I/O connections in modular control cabinets |
| Chemical Processing | Supporting field-signal connections in process-control installations |
| Oil and Gas Facilities | Maintaining compatible Foxboro I/A Series field I/O infrastructure |
| Power Generation | Supporting control-system field wiring and module connections |
| Industrial Manufacturing | Connecting field termination hardware to compatible control modules |
| Plant Maintenance | Replacing a damaged module fieldbus cable |
| System Expansion | Establishing additional field I/O connections where supported by the hardware |
| Control-System Modernization | Replacing legacy cabling with a compatible specified version |
| Industrial Electrical Cabinets | Maintaining organized connections between fieldbus modules and termination assemblies |
Application suitability depends on the FBM model, termination assembly, cable construction, and installed system architecture. Confirming these details before replacement helps prevent incorrect connections and unnecessary troubleshooting.
If a field signal remains unavailable after cable replacement, inspect the termination assembly, field wiring, FBM status, and control-system configuration. Confirm the fault location before replacing additional components.
The RH916NC is intended for compatible Foxboro I/A Series module fieldbus connections. The associated hardware must match the cable’s designated function and the system’s field I/O architecture.
| Component | Function |
|---|---|
| Foxboro I/A Series Fieldbus Modules | Interface with field signals and process devices |
| Compatible Termination Assemblies | Connect field wiring to the associated FBM interface |
| Modular Baseplates | Accommodate compatible fieldbus modules and their connections |
| Foxboro Field Control Processors | Execute control strategies in supported system configurations |
| Field Wiring Assemblies | Connect process instruments and actuators to termination hardware |
| Compatible Module Fieldbus Cables | Provide the required connection between FBMs and termination assemblies |
| System Power Supplies | Supply the installed control-system hardware |
| Engineering and Diagnostic Tools | Support hardware configuration and field I/O troubleshooting |
| Model | Product Type | Relevance |
|---|---|---|
| Foxboro P0916NC | I/A Series Module Fieldbus Cable | Earlier cable designation associated with RH916NC |
| Foxboro P0928BQ | I/A Series Module Fieldbus Cable, LSZH | Associated LSZH cable part number for the 3-meter version |
| Foxboro RH916NB | I/A Series Module Fieldbus Cable, 5 m | Related cable option for installations requiring a longer connection |
| Foxboro RH916NA | I/A Series Module Fieldbus Cable, 10 m | Related cable option for longer cable runs |
| Foxboro RH916ND | I/A Series Module Fieldbus Cable, 0.25 m | Related short cable for compatible module connections |
| Foxboro RH916MZ | I/A Series Module Fieldbus Cable, 1 m | Related cable option for a shorter module fieldbus connection |
RH916NC is the LSZH version associated with the earlier P0916NC designation. The corresponding LSZH part number P0928BQ is also listed for the 3-meter module fieldbus cable. Confirm the required cable construction and connector configuration before selecting a replacement.
Its intended role is within the module-to-termination assembly connection. Field devices normally connect through field wiring and the appropriate termination hardware. The exact arrangement depends on the FBM and termination assembly used in the installation.
Termination assemblies are designed for specific module interfaces and field wiring arrangements. A cable with the correct length may still be unsuitable if the associated hardware or connector arrangement differs. Verify the complete connection configuration before installation.
LSZH stands for low smoke, zero halogen. This material classification is relevant where smoke and halogen emissions under fire conditions are important installation considerations. It does not independently establish electrical compatibility, fire certification for a specific installation, or suitability for every operating environment.