Product Overview The Foxboro P0916NC I/A Series Module Fieldbus Cable is a communication cable used in compatible Foxboro I/A Series distributed control system installations. It forms part of the cablin……
Foxboro P0916NC I/A Series Module Fieldbus Cable
  • Foxboro
  • P0916NC
  • Module Fieldbus Cable
  • USA
  • 3 meters
  • 3 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 6

Our advantage

Foxboro P0916NC I/A Series Module Fieldbus Cable

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Foxboro P0916NC I/A Series Module Fieldbus Cable

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Foxboro P0916NC I/A Series Module Fieldbus Cable

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Foxboro P0916NC I/A Series Module Fieldbus Cable

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Foxboro P0916NC I/A Series Module Fieldbus Cable is a communication cable used in compatible Foxboro I/A Series distributed control system installations. It forms part of the cabling infrastructure that connects fieldbus-related control hardware, supporting communication between system components within the configured automation architecture.

In a modular DCS, Fieldbus Modules (FBMs) interface with process signals and field devices, while fieldbus communication infrastructure carries information between the modules and the control system. The correct cable is essential to maintaining the intended communication path, particularly in installations using multiple baseplates and interconnected fieldbus modules.

The P0916NC is listed as a 3-meter cable in Foxboro FEM100 cabling documentation. Its application should be evaluated against the actual system topology and the required connection points. Engineers maintaining an existing installation should distinguish this cable from fiber-optic network cables, baseplate terminators, and field termination cables, which serve different functions.

During maintenance or system expansion, selecting the correct cable helps preserve the intended connection between control-system components. Cable routing, connector condition, and compatibility with the installed hardware should be checked before commissioning.

Technical Specifications

Parameter Specification
Manufacturer Foxboro
Product Type I/A Series Module Fieldbus Cable
Model P0916NC
Product Family Foxboro I/A Series
Cable Function Module Fieldbus Communication
Cable Length 3 meters
System Application Compatible Foxboro I/A Series control-system cabling
Typical Use Communication connection within a modular fieldbus architecture
Shipping Weight 3 kg

Product Features

  • Dedicated system cabling: Intended for use within compatible Foxboro I/A Series control-system installations.
  • 3-meter cable length: Supports installations where this cable length meets the required routing and connection arrangement.
  • Fieldbus infrastructure integration: Supports the physical interconnection required by the configured module communication architecture.
  • Modular DCS application: Relevant to systems containing fieldbus modules, baseplates, and associated control hardware.
  • Maintenance replacement: Can be considered when an existing cable requires inspection or replacement, provided the interface and part number are verified.
  • System expansion support: May be used in compatible installations where the documented connection arrangement calls for this cable.
  • Configuration-dependent compatibility: Requires verification against the system’s cabling drawings and installed hardware.

Working Principle

The P0916NC serves as a physical connection within the Foxboro I/A Series control-system communication infrastructure. Its role is to provide the cable path required for the designated connection; the cable itself does not execute control logic or process field signals.

In a modular automation system, the control processor communicates with fieldbus modules through the system’s supported communication architecture. The modules exchange process information with the controller, allowing control strategies to respond to field measurements and issue commands to connected equipment.

A simplified communication path is:

Control Processor → Fieldbus Communication Infrastructure → Compatible Module Connection → Fieldbus Module → Process I/O

The precise position of the P0916NC within this path depends on the installed hardware and the connection specified in the system drawings. The cable should not be assigned an assumed connector type or electrical interface without confirming the relevant configuration.

Cable selection also matters when several cable types are used in the same control cabinet. A fieldbus communication cable, fiber-optic network cable, baseplate-to-baseplate cable, and module termination cable are not automatically interchangeable. Each serves a particular purpose within the system architecture.

When communication problems arise, technicians should inspect the cable for visible damage, verify the connectors and connection points, and check the status of the connected modules. If the physical connection is intact, troubleshooting should extend to the communication hardware, system configuration, and other components along the communication path.


Role in the Foxboro I/A Series Control Architecture

The P0916NC belongs to the cabling infrastructure used in compatible Foxboro I/A Series control systems. Its role is to support the required connection between the designated hardware interfaces within the configured communication arrangement.

Control Processor → Fieldbus Communication Network → Compatible Module Interface → Fieldbus Module → Field Devices

System Component Function
P0916NC Cable Provides the designated cable connection within the system architecture
Field Control Processor Executes control strategies and manages supported control operations
Fieldbus Communication Module Provides the relevant communication interface in supported configurations
Fieldbus Modules Interface with process signals and field devices
Modular Baseplates Accommodate compatible control and fieldbus hardware
Termination Assemblies Connect designated fieldbus modules to field wiring
Field Devices Supply process measurements or receive control commands
System Diagnostic Tools Help identify communication faults and hardware status problems

The P0916NC is a passive cabling component. Its contribution depends on compatible interfaces, correctly installed hardware, and a properly configured communication architecture.


Industrial Applications

Application Typical Use
Distributed Control Systems Supporting communication connections within modular Foxboro I/A Series installations
Process Automation Maintaining connections between compatible control-system components
Power Generation Supporting existing plant control-system infrastructure
Chemical Processing Maintaining cabling connections in process-control installations
Oil and Gas Facilities Supporting compatible legacy DCS installations
Industrial Control Cabinets Connecting designated control-system interfaces
Control-System Expansion Supporting additional connections where specified by the system design
Plant Maintenance Replacing a damaged cable after verifying the required part number
System Restoration Helping restore a communication path after cable or hardware servicing
Legacy Automation Support Maintaining compatible installed I/A Series equipment

Application suitability depends on the actual connection type, system topology, and installed hardware. The cable’s model number and length should be checked against the relevant system documentation before installation.


Installation and Maintenance

  1. Verify the part number: Confirm that P0916NC is the specified cable for the intended connection in the Foxboro I/A Series installation.
  2. Check the system drawings: Identify the exact connection points and confirm the cable’s intended role in the communication architecture.
  3. Verify interface compatibility: Ensure that both connected devices or assemblies support the specified cable connection.
  4. Follow maintenance procedures: Apply the site’s required isolation and control-system maintenance procedures before accessing the hardware.
  5. Inspect the cable jacket: Look for cuts, abrasion, crushing, deformation, or other visible damage that could affect cable integrity.
  6. Examine the connectors: Check connector housings and contacts for contamination, damage, or signs of poor mechanical engagement.
  7. Confirm connector orientation: Align each connector with its intended interface and avoid forcing an incompatible connection.
  8. Secure both ends: Ensure that the cable is fully seated and mechanically secured at the designated connection points.
  9. Route the cable correctly: Avoid sharp bends, excessive tension, crushing, and contact with sharp cabinet edges.
  10. Follow cabinet wiring requirements: Maintain the cable separation and routing practices specified for the installed communication system.
  11. Verify communication after installation: Check module status indicators, system alarms, and available diagnostics to confirm that the intended connection is functioning.
  12. Record maintenance results: Document the replaced part number, connection points, and commissioning observations for future troubleshooting.

If communication remains unavailable after cable replacement, inspect the connected interfaces, module status, and system configuration. A cable fault should be confirmed rather than assumed to be the only possible cause.


Compatible System Components

The P0916NC is associated with Foxboro I/A Series cabling infrastructure. Components selected for use alongside it must match the installed system’s communication architecture and the function of the relevant connection.

Component Function
Foxboro I/A Series Fieldbus Modules Interface with process signals and field devices
Foxboro FCP270 Field Control Processor Executes control functions in supported I/A Series configurations
Foxboro FCM Communication Modules Provide supported fieldbus communication interfaces
Compatible Modular Baseplates Accommodate fieldbus modules and associated connections
Fieldbus Termination Assemblies Provide the connection between designated modules and field wiring
Compatible Communication Cables Establish other required links within the system topology
System Power Supplies Supply the connected control hardware
Engineering and Diagnostic Tools Support configuration verification and fault investigation

Recommended Related Models

Model Product Type Relevance
Foxboro P0916MZ I/A Series Baseplate-to-Baseplate Cable Related cable used for a different baseplate interconnection function
Foxboro P0916NB I/A Series Communication Cable, 5 m Related cable listed in the same system cabling documentation
Foxboro P0916NA I/A Series Communication Cable, 10 m Related cable option for installations requiring a longer cable run
Foxboro P0916ND I/A Series Communication Cable, 0.25 m Related short cable listed in the FEM100 cabling documentation
Foxboro P0917JJ I/A Series Communication Cable, 0.5 m Related cable option for compatible system connections
Foxboro P0916RB I/A Series Fieldbus Terminator Related fieldbus component used for termination rather than cable interconnection

Key Advantages

  • Provides a dedicated cable connection for compatible Foxboro I/A Series installations.
  • Supports modular control-system communication infrastructure.
  • Offers a 3-meter cable length for installations requiring the corresponding connection distance.
  • Supports maintenance and restoration of existing system cabling.
  • Helps preserve the intended communication architecture when the correct interfaces and installation procedures are used.

Technical FAQs

What should be verified before installing the Foxboro P0916NC?

Confirm the part number, cable length, connection points, and interface requirements against the installed system drawings. The cable’s exact role should be verified before it is connected to fieldbus modules or other control hardware.

Can the P0916NC replace the P0916MZ baseplate-to-baseplate cable?

They should not be treated as interchangeable based on length or product family alone. P0916MZ is identified as a baseplate-to-baseplate cable, while P0916NC is associated with module fieldbus cabling. Confirm the intended connection and interface before selecting a replacement.

What are the likely causes of communication problems after cable installation?

Potential causes include loose connectors, physical cable damage, incorrect connection points, incompatible interfaces, or faults in the connected modules and communication hardware. Checking the physical installation and system diagnostics helps narrow down the cause.

Does the 3-meter cable length determine whether the P0916NC is compatible with a particular control system?

No. Cable length is only one selection criterion. Compatibility also depends on the connection type, supported communication architecture, connector arrangement, and the specific requirements of the installed Foxboro I/A Series system.