Our advantage
Global Logistics
We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.
Brand new and original
Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.
24-hour service
We provide 7*24 hours service to our customers. We will be there whenever you need us.
Price advantage
All our products are priced very favorably because we have our own warehouse and supply.
| Company Information | |||
| [email protected] | |||
| Mobile | +8615980777398 | ||
| +8615980777398 | |||
| 15980777398 |

The Allen-Bradley 2085-OW16 is a 16-point relay output expansion module designed for compatible Micro800 programmable controller systems. Manufactured by Rockwell Automation, this module allows a Micro800 controller to switch external electrical loads through relay contacts, making it suitable for industrial applications that require flexible discrete output control.
As part of the Bulletin 2085 expansion I/O family, the 2085-OW16 provides 16 relay output points in a compact modular design. Unlike transistor-based digital output modules, relay outputs use electrical contacts to switch compatible loads. Depending on the contact ratings and application requirements, this arrangement can support specified AC or DC circuits.
The module is suitable for applications involving machine control, packaging equipment, conveyor systems, assembly machinery, process equipment, and auxiliary industrial systems. It can be used to switch compatible indicator circuits, relay interfaces, solenoid valves, and other loads within the module’s electrical ratings.
For industrial automation engineers, maintenance teams, and spare-parts buyers, the 2085-OW16 is a useful component when expanding or maintaining a Micro800-based control system. Correct selection requires checking the controller’s expansion compatibility, contact ratings, load characteristics, wiring requirements, and installation conditions.
| Parameter | Specification |
|---|---|
| Brand | Allen-Bradley |
| Manufacturer | Rockwell Automation |
| Model | 2085-OW16 |
| Product Type | Relay Output Expansion Module |
| Product Family | Micro800 / Bulletin 2085 |
| Number of Outputs | 16 relay output points |
| Output Technology | Electromechanical relay contacts |
| Nominal System Voltage | 12/24 V DC, as identified in the product family description |
| Relay Contact Switching | Compatible AC and DC loads within specified contact ratings |
| Continuous Current | Up to 2 A per output, subject to load and contact ratings |
| Contact Rating at 120 V AC | 2 A continuous; make/break limits apply |
| Contact Rating at 240 V AC | 2 A continuous; make/break limits apply |
| Contact Rating at 24 V DC | 1 A continuous |
| Contact Rating at 125 V DC | 0.22 A continuous |
| Minimum Load | 10 mA per point |
| Status Indication | LED channel status indicators |
| I/O Isolation | Isolated relay output circuitry |
| Maximum Bus Current Draw | 160 mA at 5 V DC and 100 mA at 24 V DC |
| Total Power Dissipation | 5.14 W |
| Operating Temperature | -20 to 65°C (-4 to 149°F), subject to installation conditions |
| Dimensions | 90 × 44.5 × 87 mm, as supplied |
| Weight | 0.22 kg, as supplied |
| Typical Applications | Discrete machine control, relay switching, industrial equipment |
| Product Status | Active, according to the manufacturer’s product listing |
Important: Relay contact ratings depend on voltage, load type, power factor, and switching conditions. The maximum continuous current is not the same as the permitted make or break current. The manufacturer publishes dimensions of 44.5 × 90 × 87 mm (H × W × D). The supplied listing gives 90 × 44.5 × 87 mm and 0.22 kg; verify the actual shipping weight and packaging details with the supplier.
The main function of the 2085-OW16 is to switch external electrical circuits in response to commands from a compatible Micro800 controller.
When the controller activates an output point, the associated relay changes contact state. This allows the connected circuit to be energized or de-energized according to the application logic. When the output command changes, the relay returns to its corresponding state.
Typical applications include switching compatible indicator circuits, relay coils, selected solenoid valve circuits, and other electrical loads that fall within the specified contact ratings.
The controller executes the programmed logic, while the relay module provides the physical switching interface between the control system and the external circuit.
The 2085-OW16 provides 16 relay output points, allowing one compatible controller to operate multiple devices through independently controlled output channels.
For example, a packaging machine may use separate outputs for an alarm circuit, a pneumatic valve, an auxiliary relay, and several machine-status indicators. The controller program determines when each output should change state based on sensor feedback, operating modes, and programmed sequences.
This arrangement makes the module useful in machines that require several discrete switching functions but do not need a separate output module for each device.
One important characteristic of relay outputs is that the contacts can switch suitable AC or DC circuits when used within their respective ratings. This provides greater flexibility than a DC-only transistor output module.
However, the permitted contact current varies with the applied voltage and load type. For example, the specified continuous current at 24 V DC differs from the rating at 120 V AC. DC loads can also be more demanding on relay contacts because current interruption characteristics differ from those of AC circuits.
Before connecting a load, engineers should check the contact voltage, continuous current, inrush current, switching frequency, and whether the load is resistive, inductive, or capacitive.
The module includes LED status indication to assist with commissioning and troubleshooting. These indicators help technicians observe the state of the output channels and compare it with the controller’s commands.
If an output is commanded on but the connected device does not operate, the technician can check the controller logic, the channel indicator, the external power supply, wiring, and the load itself.
A status LED does not confirm that the relay contacts are electrically healthy or that the external device has operated successfully. Further testing may be required to identify a failed contact, wiring fault, or damaged load.
Relay contacts provide electrical separation between the control-side switching mechanism and the external load circuit within the module’s specified isolation limits.
This arrangement can be useful when the controller needs to command a load operating at a different circuit voltage. Nevertheless, the module must be installed according to the manufacturer’s wiring and isolation requirements. Isolation should not be treated as a substitute for correct grounding, circuit protection, or electrical safety procedures.
The 2085-OW16 functions as an output interface within a compatible Micro800 automation system. The controller executes the application program and determines the required output states, while the relay module switches the connected field circuits.
A typical Micro800 installation may include:
The 2085-OW16 does not execute a control program independently. Its output states are determined by the controller and its configured I/O mapping.
The complete system design should consider controller compatibility, expansion limits, output contact ratings, field wiring, and the electrical characteristics of every connected load.
Packaging equipment uses discrete outputs to coordinate product movement, auxiliary actuators, alarm circuits, and machine sequences.
The 2085-OW16 can switch compatible AC or DC loads where the contact ratings permit. The controller may use input signals from product sensors and limit switches to determine when to activate each output.
This helps coordinate packaging stages and supports repeatable operation across production cycles.
Conveyor systems often require discrete control of auxiliary devices, relay interfaces, indicators, and selected actuators.
The module can operate compatible loads according to the controller’s logic. For motor control, the relay output should generally operate an appropriate motor starter or interface rather than directly switch a motor unless the motor load is specifically within the relay’s ratings and approved for that application.
Assembly equipment frequently relies on discrete commands to control clamping, positioning, release, and transfer mechanisms.
The 2085-OW16 can provide output signals for compatible devices, while the controller coordinates operations using sensor feedback and programmed interlocks.
The relay-based design can be useful when the application requires contact switching rather than a transistor output.
Small industrial process systems may require outputs for pumps, valves, alarms, auxiliary equipment, and other control functions.
The 2085-OW16 can be considered for switching suitable control circuits. Higher-current loads or equipment with substantial starting current may require external contactors or other switching interfaces.
Engineers should verify the actual load characteristics rather than selecting the module based solely on the nominal voltage or current shown on a device label.
The module can be used to switch compatible alarm devices, status indicators, and auxiliary relay circuits. This is useful when an industrial controller must activate different signals according to equipment state or process conditions.
Where alarm functions are safety-critical, the overall design must use appropriately rated equipment and validated safety procedures. A standard relay output module should not be treated as a safety-rated output system.
Before installing the 2085-OW16, confirm that the target Micro800 controller supports the module and the planned expansion arrangement.
Check the controller model, firmware requirements, supported expansion capacity, and the applicable hardware documentation. Do not assume that every controller in the Micro800 family supports identical module configurations.
Review the voltage and current requirements of every connected load. The 2085-OW16 has a maximum continuous contact current of 2 A per point under specified conditions, but the allowable current varies with voltage and load type.
For example, the published continuous rating for a 24 V DC load is lower than the rating for certain AC loads. Make and break current limits must also be considered when selecting a load.
Motors, transformers, solenoids, and other inductive devices can have high inrush currents or demanding switching characteristics. Use an appropriate contactor, relay interface, or suppression circuit when required.
Because relay contacts can switch suitable AC or DC circuits, wiring must be planned according to the specific circuit voltage and contact ratings.
Keep circuit identification clear and label conductors to distinguish different voltages. Observe the manufacturer’s requirements for terminal connections, insulation, wire sizes, conductor routing, and separation between circuits.
Never assume that all output terminals can be connected to the same voltage or common point without checking the wiring diagram.
The relay contacts and field wiring must be protected according to the load, conductor size, and applicable electrical standards. Use appropriately rated fuses or circuit protection where required by the system design.
For inductive loads, consider suitable suppression components to reduce switching transients and help protect contacts and other equipment. Select suppression based on the load characteristics and manufacturer’s recommendations.
Electromechanical relay contacts wear over time. Contact life depends on the electrical load, switching frequency, inrush current, and environmental conditions.
Applications that switch frequently or interrupt demanding inductive loads may experience faster contact wear than applications with occasional switching of suitable resistive loads.
Where frequent switching is required, compare the expected operating cycle with the relay’s electrical-life specifications and consider a transistor output module or an external switching interface if appropriate.
After wiring, test each output point individually under controlled conditions. Verify that the controller commands the correct channel, that the status indicator responds as expected, and that the connected load operates correctly.
Check for incorrect terminal assignments, loose connections, unexpected output states, and excessive load current before placing the equipment into normal service.
Keep updated electrical drawings, I/O lists, controller project backups, module model information, and load specifications.
Good documentation helps maintenance personnel identify the correct channel, determine the expected contact ratings, and replace equipment without introducing wiring errors.
Before removing or installing the module, follow the applicable electrical isolation procedures and verify that all relevant circuits are in a safe condition.
The following components are examples of equipment categories and related models used in Micro800 systems. Actual compatibility depends on the selected controller, firmware, expansion arrangement, and electrical requirements.
| Model / Component | Type | Function |
|---|---|---|
| Compatible Micro800 controller | Programmable controller | Executes control logic and manages supported expansion I/O |
| 2085-OW16 | 16-point relay output module | Switches compatible AC or DC loads within specified contact ratings |
| 2085-OW16K | 16-point relay output module with conformal coating | Related model for applications requiring the coated version; verify environmental requirements |
| 2085-OW8 | 8-point relay output module | Provides fewer relay output points |
| 2085-OV16 | 16-point sinking DC output module | Provides DC transistor outputs rather than relay contacts |
| 2085-OB16 | 16-point sourcing DC output module | Provides sourcing DC transistor outputs |
| 2085-IQ16 | 16-point DC digital input module | Receives discrete input signals |
| 2085-IQ32T | 32-point DC digital input module | Provides a higher number of input points |
| Relay interface or contactor | External switching device | Switches loads that require a separate power interface |
| Industrial power supply | Power supply | Provides suitable power for controller and field circuits |
These are related system components rather than universal plug-in replacements. Check the controller’s supported modules, output type, electrical ratings, and installation requirements before combining or substituting components.
When selecting an alternative to the 2085-OW16, the required output technology is an important consideration. Relay, sourcing transistor, and sinking transistor outputs have different operating characteristics and wiring requirements.
| Model | Output Technology | Main Consideration |
|---|---|---|
| 2085-OW16 | 16-point relay output | Reference model for this product |
| 2085-OW16K | 16-point relay output with conformal coating | Consider when the coated version is required |
| 2085-OW8 | 8-point relay output | Provides fewer output points |
| 2085-OV16 | 16-point sinking DC transistor output | Suitable for compatible DC loads requiring sinking outputs |
| 2085-OB16 | 16-point sourcing DC transistor output | Suitable for compatible DC loads requiring sourcing outputs |
The 2085-OV16 and 2085-OB16 are not direct electrical equivalents to the 2085-OW16. They use transistor outputs and have different load and voltage limitations.
The 2085-OW16K is a related relay-output option with conformal coating, but it should not be selected automatically without checking the environmental requirements and exact specifications.
For a direct replacement, verify the complete catalog number, hardware condition, controller compatibility, terminal arrangement, contact ratings, and application requirements. A replacement should be assessed against the actual load rather than only its number of output points.
The module provides 16 individually controlled relay output points for applications that require multiple switching functions.
Relay contacts can switch suitable AC or DC circuits when operated within the applicable contact ratings. This gives engineers flexibility when designing discrete control systems.
The relay-based output design provides electrical separation between the control mechanism and the external load circuit within the specified isolation limits.
LED indicators help technicians check channel status during commissioning and routine troubleshooting.
The 2085-OW16 adds output capacity to a compatible Micro800 controller installation, supporting system expansion without requiring a separate controller for each additional output group.
A clearly identified model number helps equipment owners specify the correct replacement and maintain an appropriate inventory of automation components.
Q1: What is the Allen-Bradley 2085-OW16?
The 2085-OW16 is a 16-point relay output expansion module designed for compatible Micro800 automation systems. It allows a controller to switch external electrical loads through relay contacts.
Q2: How many output points does the 2085-OW16 have?
It provides 16 relay output points.
Q3: Can the 2085-OW16 switch both AC and DC loads?
Yes, the relay contacts can switch compatible AC or DC loads within the specified contact ratings. The allowable current differs by voltage and load type, so the applicable ratings must be checked before installation.
Q4: What is the maximum continuous current per output?
The maximum continuous current is up to 2 A per output under specified conditions. However, the permissible current depends on the applied voltage and load. For example, the published continuous rating at 24 V DC is 1 A, while the rating at 125 V DC is 0.22 A.
Q5: What is the difference between the 2085-OW16 and 2085-OV16?
The 2085-OW16 uses electromechanical relay contacts, while the 2085-OV16 uses sinking DC transistor outputs. Relay outputs support suitable AC or DC circuits within their ratings; the OV16 is intended for compatible DC loads.
Q6: Is the 2085-OW16 suitable for motor control?
It may be used to control an appropriate motor starter or interface circuit. Direct motor switching should only be considered if the motor load is explicitly within the module’s permitted contact ratings and the application is suitable. In many cases, a properly rated contactor or motor starter is required.
Q7: Does the module have output status LEDs?
Yes. LED status indication helps technicians observe output-channel status during commissioning and troubleshooting.
Q8: What are the dimensions and weight of the 2085-OW16?
The supplied listing gives dimensions of 90 × 44.5 × 87 mm and a weight of 0.22 kg. The manufacturer’s published dimensions are 44.5 × 90 × 87 mm in height × width × depth order. Published weight figures can vary by documentation version and whether shipping packaging is included, so confirm the actual shipping weight with the supplier.
Q9: What should be checked when replacing a 2085-OW16?
Confirm the catalog number, controller compatibility, output wiring, load voltage, continuous current, make/break current, and switching frequency. After installation, test each channel and verify the connected equipment under controlled conditions.
Q10: Is the 2085-OW16 still an active product?
The manufacturer’s product listing identifies the 2085-OW16 as active. Confirm current availability, product condition, and delivery details with the supplier before ordering.
When sourcing the Allen-Bradley 2085-OW16, provide the full catalog number and clarify whether the module is intended for a new installation, system expansion, or replacement of a failed unit.
For replacement applications, compare the model number on the existing module with the product listing. Verify that the controller supports the module and that the relay contact ratings meet the actual load requirements.
Industrial automation buyers should confirm the unit’s condition, warranty terms, packaging, and included accessories. If the module will be used in a critical production process, keeping a suitable spare can help reduce downtime caused by an unexpected relay or wiring failure.
During routine maintenance, inspect terminal connections, check output status indicators, and verify that connected loads respond correctly. If a channel fails to operate, examine the controller command, external power supply, field wiring, and load before deciding that the module itself requires replacement.
For applications with frequent switching, monitor relay performance and assess contact wear based on the load type and operating cycle. Keep wiring diagrams and I/O assignments updated so replacement work can be completed accurately.
Always follow the applicable electrical isolation and safety procedures before handling the module or its wiring.
The Allen-Bradley 2085-OW16 Micro800 16-Point Relay Output Module is designed to provide flexible discrete switching for compatible Micro800 automation systems. Its 16 relay output points, channel status indication, and ability to switch suitable AC or DC circuits make it useful for a broad range of industrial control applications.
The module can be considered for packaging machinery, conveyor systems, assembly equipment, process auxiliaries, and other installations that require multiple relay-switched outputs. Reliable operation depends on checking controller compatibility, contact ratings, field wiring, load characteristics, and switching frequency.
For industrial automation equipment buyers and maintenance engineers, the 2085-OW16 is a practical component to consider when expanding or maintaining a Micro800-based control system. Correct product identification and careful electrical integration help reduce compatibility problems and support long-term equipment maintenance.