• Schneider NS630H Circuit Breaker
  • Schneider NS630H Circuit Breaker
  • Schneider NS630H Circuit Breaker
  • Schneider NS630H Circuit Breaker
Product Overview The Schneider Electric NS630H Compact Circuit Breaker is a high-capacity molded case circuit breaker designed for electrical distribution and industrial power protection applications. B……
Schneider NS630H Circuit Breaker
  • Schneider
  • NS630H
  • Circuit Breaker
  • France
  • 327 x 280 x 147 mm
  • 18 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 23

Our advantage

Schneider NS630H Circuit Breaker

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Schneider NS630H Circuit Breaker

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Schneider NS630H Circuit Breaker

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Schneider NS630H Circuit Breaker

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Schneider Electric NS630H Compact Circuit Breaker is a high-capacity molded case circuit breaker designed for electrical distribution and industrial power protection applications. Belonging to the Compact NS family, it is used to protect electrical circuits against overloads and short circuits in demanding low-voltage power distribution systems.

In industrial facilities, reliable circuit protection is essential for maintaining equipment safety and reducing the risk of electrical damage. Large motors, production machinery, distribution panels, and other electrical loads require protective devices capable of interrupting fault currents and isolating affected circuits when abnormal conditions occur.

The NS630H is associated with a 630 A frame rating and is commonly used in three-phase power distribution systems. Depending on the selected trip unit and product configuration, it provides adjustable protection functions for managing overload and short-circuit conditions. Certain STR23SE-equipped configurations provide long-time, short-time, and instantaneous protection.

The circuit breaker’s high interrupting capacity makes it suitable for applications where substantial prospective fault currents may occur. Published specifications for certain NS630H configurations indicate an ultimate breaking capacity of up to 70 kA at 380/415 V AC. The applicable rating must always be checked against the exact breaker configuration and installation conditions.

The NS630H can be installed in industrial distribution boards, main switchboards, motor control centers, and other electrical distribution assemblies. Its suitability depends on system voltage, rated current, prospective short-circuit current, protection coordination, and the characteristics of the connected electrical loads.

When purchasing or replacing an NS630H, engineers should verify the complete product configuration, including pole count, trip unit, connection arrangement, accessories, and mounting requirements.

Technical Specifications

Parameter Specification
Brand Schneider Electric
Product Model NS630H
Product Family Compact NS
Product Type Molded Case Circuit Breaker (MCCB)
Rated Frame Current 630 A
Common Configuration 3-pole
Application Electrical Distribution
Network Type AC / DC, depending on configuration
AC Frequency 50/60 Hz
Rated Operational Voltage Up to 690 V AC for applicable configurations
Rated Insulation Voltage 750 V AC for documented configurations
Rated Impulse Withstand Voltage 8 kV for documented configurations
Breaking Capacity Up to 70 kA at 380/415 V AC for certain configurations
Trip Unit Configuration-dependent; STR23SE available
Protection Functions Overload and short-circuit protection
Mounting Fixed mounting, configuration-dependent
Connection Front connection for documented configurations
Dimensions Provided 327 × 280 × 147 mm
Weight Provided 18 kg
Product Category Industrial Circuit Protection

Technical specifications can vary according to the exact NS630H reference, trip unit, pole configuration, and accessories. Confirm the product nameplate and technical documentation before installation.

Function and Working Principle

The NS630H operates by monitoring current flowing through the protected electrical circuit. When current exceeds the configured protection limits or a short circuit occurs, its trip mechanism initiates circuit interruption.

This protects downstream electrical equipment and helps prevent abnormal current conditions from damaging cables, motors, transformers, and distribution components.

1. Overload Protection

An overload occurs when an electrical circuit carries more current than its permitted operating level for an extended period.

The NS630H can be equipped with a suitable trip unit that provides long-time overload protection. When the current exceeds the configured threshold for the specified duration, the protection mechanism causes the breaker to trip.

The long-time protection settings should be selected according to the rated capacity of the protected cables, connected equipment, and electrical installation.

2. Short-Circuit Protection

A short circuit can produce a sudden and substantial increase in current. If the fault is not interrupted quickly, it can cause excessive heating, equipment damage, and dangerous electrical conditions.

The NS630H is designed to interrupt high fault currents within its applicable breaking-capacity limits.

The exact short-circuit protection functions depend on the installed trip unit. Certain electronic trip configurations provide short-time and instantaneous protection.

3. Adjustable Protection Settings

Some NS630H configurations equipped with electronic trip units offer adjustable protection parameters.

These settings allow electrical engineers to coordinate circuit protection with the characteristics of the installation. For example, long-time pickup settings can be adjusted according to the protected circuit’s rated current.

Correct coordination helps ensure that a downstream protective device operates when a local fault occurs, reducing unnecessary interruption of the wider electrical distribution system.

4. Circuit Isolation

The NS630H can also serve as a means of switching and isolating an electrical circuit when the selected configuration is suitable for the application.

Its switching mechanism allows operators to open or close the protected circuit. For maintenance work, the isolation procedure must follow the installation’s electrical safety requirements and applicable lockout procedures.

5. Fault Interruption

When a fault causes the breaker to trip, the internal contacts separate and the arc-interruption system extinguishes the electrical arc.

This process interrupts the current and isolates the affected circuit. The breaker must be selected according to the prospective fault current and the electrical characteristics of the installation.

Role in Industrial Power Distribution Systems

The NS630H is commonly considered for applications requiring high-current circuit protection. It can serve as a main or branch protective device depending on the distribution architecture and the requirements of the installation.

Main Distribution Protection

In industrial switchboards, the NS630H can protect a major incoming or outgoing feeder. It helps protect downstream distribution equipment against overload and short-circuit conditions.

Its 630 A frame rating makes it relevant to installations with substantial electrical loads, provided the selected trip unit and protection settings are appropriate.

Motor Control Center Protection

Motor control centers contain multiple motor starters, drives, contactors, and protective devices. A suitably configured NS630H can provide upstream protection for a motor control center or a major feeder.

Protection coordination between the main breaker and downstream motor protection devices is important for maintaining system availability.

Transformer and Feeder Protection

The breaker may be incorporated into distribution systems serving transformers and large electrical feeders. Engineers must consider transformer characteristics, cable ratings, fault levels, and protection coordination when selecting the breaker.

The appropriate trip settings depend on the electrical design and the equipment being protected.

Industrial Electrical Safety

By interrupting overload and short-circuit currents within its rated operating limits, the NS630H helps reduce the risk of electrical equipment damage.

It should form part of a complete protection strategy that also includes correct grounding, suitable cable sizing, upstream protection, and appropriate maintenance procedures.

Industrial Applications

The Schneider Electric NS630H is suitable for consideration in a range of industrial electrical distribution applications.

1. Manufacturing Facilities

Manufacturing plants use substantial electrical power for production machinery, automation systems, pumps, compressors, and material-handling equipment.

The NS630H can be used in distribution panels to protect major feeders supplying these loads. Its protection settings should be coordinated with downstream equipment.

2. Motor Control Centers

Motor control centers distribute electrical power to multiple motors and associated control equipment.

A suitably configured NS630H can provide protection for an MCC incoming feeder or another high-current distribution circuit.

3. Industrial Power Distribution Panels

Electrical distribution panels require protective devices capable of handling the expected operating current and interrupting prospective fault currents.

The NS630H can be incorporated into appropriate low-voltage distribution assemblies where its rated voltage, current, breaking capacity, and installation configuration meet the design requirements.

4. Commercial and Infrastructure Facilities

Large commercial buildings and infrastructure installations may contain electrical distribution systems with substantial feeder loads.

The NS630H may be used in suitable switchboards to protect major circuits supplying building services, mechanical equipment, and other electrical loads.

5. Energy and Utility Installations

Power distribution systems in energy-related facilities require dependable circuit protection. The NS630H can be considered for suitable low-voltage distribution applications where its electrical ratings and protection characteristics meet the system requirements.

6. Industrial Process Equipment

Process plants often use pumps, compressors, ventilation systems, and other high-power equipment. The NS630H can protect appropriate distribution circuits supplying these systems.

The breaker must be coordinated with motor starting characteristics, downstream protective devices, and the facility’s fault-current calculations.

Installation and System Integration

Proper installation is essential for ensuring that the NS630H operates safely and provides the intended circuit protection.

1. Verify Electrical Ratings

Before installation, confirm the system voltage, operating frequency, rated current, and prospective short-circuit current.

The 630 A frame rating should not be treated as an automatic indication that every installation can operate continuously at 630 A. The selected trip unit and its settings determine the applicable protection characteristics.

2. Confirm Trip Unit Configuration

The trip unit is an important part of the breaker configuration. Different trip units provide different protection functions and adjustment ranges.

Before ordering a replacement, identify the existing trip unit and confirm that the new unit provides the required long-time, short-time, and instantaneous protection functions.

3. Check Mounting and Dimensions

The supplied product dimensions are 327 × 280 × 147 mm.

Before installing the breaker in a switchboard, verify the actual mechanical dimensions, mounting arrangement, terminal positions, and required installation clearances.

Do not rely solely on the dimensions of a similar NS630H configuration because different accessories and connection arrangements may affect the overall installation space.

4. Electrical Connections

The incoming and outgoing conductors must be selected according to the rated current, installation conditions, and applicable electrical regulations.

Check terminal compatibility, conductor cross-section, tightening torque, and connection condition. Poor electrical connections can cause overheating and unreliable operation.

5. Protection Coordination

The NS630H should be coordinated with upstream and downstream protective devices.

Engineers should evaluate the available fault current, cable ratings, load characteristics, and selectivity requirements. Incorrect protection settings may cause unnecessary tripping or inadequate protection.

6. Commissioning and Testing

Before energizing the installation, inspect the breaker body, operating mechanism, terminals, and associated electrical connections.

Verify the trip-unit configuration and protection settings. Carry out the required electrical and functional tests according to the manufacturer’s procedures and applicable standards.

All commissioning work should be performed by qualified electrical personnel.

Compatible System Components

The NS630H is generally installed as part of a larger electrical distribution system.

Component Function Integration Considerations
Schneider Electric Compact NS accessories Extend breaker operating and installation functions Confirm compatibility with the exact NS630H version
Electronic trip unit Provides overload and short-circuit protection Verify trip-unit type and protection settings
Electrical distribution busbar Distributes current within the switchboard Check current rating, spacing, and connection arrangement
Current transformer Provides current measurement for compatible systems Confirm ratio, accuracy, and application requirements
Auxiliary contact Provides breaker status information Verify contact type and accessory compatibility
Shunt trip Enables remote electrical tripping Check control voltage and accessory reference
Undervoltage release Trips or prevents operation under specified voltage conditions Confirm voltage rating and compatible mechanism
Control panel Supports electrical monitoring and operation Verify wiring and installation requirements
Downstream circuit breakers Protect individual outgoing circuits Coordinate ratings and trip characteristics
Electrical enclosure Provides mechanical and environmental protection Confirm dimensions, mounting, and required clearances

Not all accessories are included with the standard breaker. Their compatibility should be confirmed using the exact product reference.

Alternative Models and Replacement Considerations

When replacing an NS630H, the replacement should be selected according to the electrical and mechanical requirements of the original installation.

Alternative Model or Series Replacement Considerations
Schneider Electric Compact NS630H Suitable for like-for-like replacement when the complete configuration matches
Schneider Electric ComPacT NSX630H A later product family that may be considered after checking electrical and mechanical compatibility
Schneider Electric ComPacT NSX630N A related 630 A frame option, but its breaking-capacity characteristics differ
Schneider Electric ComPacT NS630b A different breaker family with different technical characteristics
Other 630 A MCCBs May be considered if voltage, breaking capacity, trip functions, dimensions, and certification requirements are satisfied

When evaluating a replacement, compare the following:

  • Rated operational voltage.
  • Frame current and trip-unit rating.
  • Number of poles.
  • Ultimate and service breaking capacity.
  • Long-time, short-time, and instantaneous protection.
  • Mounting and connection arrangement.
  • Auxiliary contacts and control accessories.
  • Overall dimensions and installation clearances.
  • Protection coordination with upstream and downstream equipment.

A replacement breaker should never be selected based only on its 630 A frame rating. The interrupting capacity and protection characteristics must be suitable for the actual electrical installation.

Key Advantages

High-Current Circuit Protection

The NS630H is designed for industrial distribution applications involving substantial electrical loads. Its 630 A frame rating makes it suitable for appropriately engineered high-current circuits.

High Interrupting Capacity

Certain documented configurations provide a breaking capacity of up to 70 kA at 380/415 V AC. This characteristic is important in distribution systems with high prospective fault currents.

Electronic Protection Options

Compatible electronic trip units provide configurable protection functions, allowing engineers to adapt circuit protection to the requirements of the installation.

Multiple Industrial Applications

The breaker can be considered for main distribution panels, feeder protection, motor control centers, and industrial switchboards.

Integration with Electrical Distribution Systems

The Compact NS family is designed for use in industrial low-voltage distribution assemblies, allowing the NS630H to form part of a coordinated protection system.

Maintenance and Replacement Support

The NS630H remains relevant to facilities operating legacy Compact NS installations. Accurate identification of the original breaker configuration supports maintenance and replacement planning.

Technical FAQs

1. What is the Schneider Electric NS630H?

The NS630H is a Compact NS molded case circuit breaker designed for industrial electrical distribution and circuit protection. It is associated with a 630 A frame rating.

2. What is the rated current of the NS630H?

The common frame rating is 630 A. The actual trip rating and operating settings depend on the installed trip unit and product configuration.

3. How many poles does the NS630H have?

A common NS630H configuration is three-pole. Other configurations and associated references should be checked individually before ordering.

4. What is the breaking capacity of the NS630H?

Certain documented configurations provide an ultimate breaking capacity of 70 kA at 380/415 V AC. The exact value depends on the voltage and breaker configuration.

5. What protection functions does the NS630H provide?

Depending on the installed trip unit, the breaker can provide overload, short-time short-circuit, and instantaneous short-circuit protection.

6. Can the NS630H be used in a motor control center?

Yes. A suitable NS630H configuration can be used as an incoming or feeder protective device in a motor control center. Protection coordination with downstream motor circuits is essential.

7. Is the NS630H suitable for three-phase power distribution?

Yes. Three-pole configurations are commonly used in three-phase industrial distribution systems. The voltage, current, fault level, and grounding arrangement must be checked before installation.

8. What should be checked before replacing an NS630H?

Verify the complete product reference, pole count, trip unit, rated current, breaking capacity, connection arrangement, accessories, and mechanical dimensions.

9. Can the NS630H be replaced with a ComPacT NSX630H?

A ComPacT NSX630H may be considered as a replacement candidate, but it should not be assumed to be a direct mechanical or electrical substitute. Terminal arrangements, mounting dimensions, accessories, and protection characteristics must be evaluated.

10. What maintenance is recommended for the NS630H?

Maintenance should include visual inspection, terminal and connection checks, operating-mechanism inspection, verification of trip-unit settings, and appropriate functional testing. Follow the manufacturer’s maintenance instructions and applicable electrical safety procedures.

Procurement and Maintenance Recommendations

When sourcing a Schneider Electric NS630H, accurate product identification is essential. The Compact NS family includes different frame sizes, trip units, pole configurations, and accessory combinations. A breaker with a similar appearance may not have the same protection characteristics.

Before purchasing, confirm the complete product reference and inspect the nameplate. Verify the rated current, operational voltage, breaking capacity, trip-unit type, pole count, and connection arrangement.

For used or refurbished equipment, request clear photographs of the front panel, terminals, trip unit, and identification label. Ask for available testing information and confirm the mechanical condition of the operating mechanism.

For replacement projects, compare the original installation drawings with the proposed breaker configuration. Check mounting dimensions, busbar connections, cable requirements, and accessory compatibility before installation.

During routine maintenance, inspect the breaker for signs of overheating, damaged insulation, loose connections, contamination, and mechanical wear. Protection settings should be documented and should not be changed without an appropriate engineering assessment.

Electrical testing and maintenance should be carried out by qualified personnel using approved procedures. The breaker should be isolated and verified de-energized before maintenance work begins.

Conclusion

The Schneider Electric NS630H Compact Circuit Breaker is a high-current molded case circuit breaker designed for industrial electrical distribution and protection applications. With a common 630 A frame rating and high-interrupting-capacity configurations, it can be used in suitable switchboards, motor control centers, feeder circuits, and industrial power distribution systems.

Its actual performance depends on the installed trip unit, rated voltage, pole configuration, and protection settings. For maintenance and replacement projects, verifying the complete product reference and electrical characteristics is essential to ensure safe and reliable integration into the existing power distribution system.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501