The Schneider Electric BMXCPS4022S Redundant Power Supply Module is an industrial power supply designed for the Modicon X80 automation platform. It provides regulated power to the controller and I/O modules installed in a compatible backplane, supporting stable operation in industrial automation and process-control systems.
As part of the Modicon X80 range, the BMXCPS4022S is designed for applications requiring dependable DC power distribution and advanced power supply diagnostics. It accepts a 24–48 V DC primary input and generates the secondary voltages required by the automation backplane.
The module provides two main output power functions: 3.3 V DC for I/O module logic and 24 V DC for I/O module power and the processor, subject to the specified loading conditions. Its rated secondary power capabilities include 18 W at 3.3 V DC and up to 40 W at 24 V DC under the documented operating conditions.
One of its important characteristics is support for redundant power supply configurations. Two compatible power supply modules can be installed in an appropriate redundant Ethernet backplane, with one operating as the primary supply and the other as the secondary supply. This arrangement helps maintain system power availability if one supply experiences a fault.
The BMXCPS4022S also incorporates diagnostic functions that provide information about redundancy status, operating temperature, remaining service life, and operating time. These features can assist maintenance personnel in identifying power supply problems and planning preventive maintenance.
With its industrial design, protection functions, and compatibility with the Modicon X80 platform, the BMXCPS4022S is suitable for automation installations where stable backplane power and system availability are important.
| Parameter | Specification |
|---|---|
| Brand | Schneider Electric |
| Model | BMXCPS4022S |
| Product Series | Modicon X80 |
| Product Type | Redundant Power Supply Module |
| Application | Industrial Automation / Safety Systems |
| Primary Input Voltage | 24–48 V DC |
| Primary Voltage Range | 18–62.4 V DC |
| Input Current at 24 V DC | 1.9 A |
| Input Current at 48 V DC | 1 A |
| Secondary Output | 3.3 V DC and 24 V DC |
| 3.3 V DC Secondary Power | 18 W |
| 24 V DC Secondary Power | Up to 40 W under specified loading conditions |
| 3.3 V DC Output Current | 5 A |
| 24 V DC Output Current | 1.67 A |
| Redundancy Support | Yes |
| Diagnostic Functions | Redundancy status, remaining lifetime, temperature sensing, uptime |
| Protection Functions | Overload, overvoltage, short-circuit |
| Status Indicators | Voltage OK, redundancy OK, power supply status |
| Reset Function | Front-panel RESET push-button |
| Maximum Power Dissipation | 8.5 W |
| Protection Rating | IP20 |
| Operating Temperature | -25°C to +60°C under specified power conditions |
| Dimensions Provided | 250 × 178 × 90 mm |
| Weight | 0.81 kg |
| Product Family | Modicon X80 |
Note: The weight of 0.81 kg matches the manufacturer’s published net weight. The dimensions above are the supplied listing values; verify the mechanical drawing and packaging dimensions before panel installation or shipping.
The BMXCPS4022S converts incoming DC electrical power into regulated secondary voltages for the Modicon X80 backplane. These voltages supply the electronic circuits of the controller and associated I/O modules.
The module accepts a primary DC input between 24 V and 48 V. The permitted primary voltage range is 18–62.4 V DC.
Its internal power conversion circuitry regulates the incoming supply and generates the required secondary power rails. This allows the controller and connected modules to receive the appropriate operating voltages.
The input voltage must remain within the specified limits to ensure stable operation and avoid unnecessary power supply faults.
The 3.3 V DC output supplies the logic circuits of compatible I/O modules and other backplane electronics.
Stable logic power is essential for digital processing, signal interpretation, internal communication, and module operation. Voltage instability can affect the behavior of connected automation equipment.
The BMXCPS4022S provides a documented 3.3 V DC output capability of 5 A, corresponding to 18 W under the specified operating conditions.
The module also provides a 24 V DC output for compatible I/O module power requirements and the processor when the specified loading conditions permit.
The documented 24 V DC output current is 1.67 A, with a rated power capability of up to 40 W.
The available power depends on the actual loading of the 3.3 V and 24 V output circuits. Engineers should calculate the total backplane load rather than assume that both output ratings can always be used independently at their maximum values.
The BMXCPS4022S supports redundant power supply arrangements in compatible Modicon X80 configurations.
In a redundant installation, two suitable power supply modules can be installed in the designated redundant backplane positions. One module serves as the primary supply, while the other provides backup power.
The redundancy management functions help monitor the operating condition of both supplies. If a fault occurs in one supply, the redundant arrangement is designed to help maintain power availability for the automation system.
Actual redundancy behavior depends on the supported backplane configuration, correct installation, and the availability of an appropriate independent power source.
The module provides diagnostic information covering redundancy status, temperature, remaining service life, and uptime.
It also includes protection against secondary-side overload, overvoltage, and short-circuit conditions. These functions help protect connected equipment from certain electrical abnormalities.
Front-panel LED indicators provide information about voltage presence, redundancy status, and general power supply operation.
The BMXCPS4022S serves as a power supply component in Modicon X80 automation architectures. Its function is essential because the processor, communication modules, and I/O modules depend on stable backplane power.
A programmable automation controller requires stable power to execute its control program and manage connected equipment.
The BMXCPS4022S supplies the appropriate secondary voltages to compatible controller hardware. This allows the automation platform to process input signals, execute logic, and update output states.
Industrial I/O modules collect information from field devices and transmit control signals to actuators and other equipment.
The power supply supports the logic and power requirements of compatible backplane modules. Correct power distribution helps maintain reliable signal processing and module operation.
The BMXCPS4022S is identified as a Modicon X80 redundant safety power supply module and is used in supported Modicon M580 safety configurations.
In safety-related installations, the specified power supply family must be used according to the system design and applicable safety documentation. Replacing it with an ordinary power supply simply because the physical dimensions or voltage appear similar may result in an incompatible installation.
Power supply failure can interrupt controller operation and affect the availability of an entire production system.
When installed in a supported redundant configuration, the BMXCPS4022S can help reduce the risk of system interruption caused by a single power supply failure.
The effectiveness of this arrangement depends on correct system configuration, backplane compatibility, input power design, and maintenance.
The BMXCPS4022S is designed for industrial automation systems that use compatible Modicon X80 hardware.
Chemical processing, water treatment, and manufacturing facilities often rely on programmable controllers to manage pumps, valves, motors, and process instruments.
The BMXCPS4022S supplies the controller backplane, helping maintain stable operation of the automation hardware.
Its redundancy capabilities are particularly relevant to installations where unexpected power interruptions can affect production continuity.
Automated production lines use distributed I/O modules to monitor sensors and control actuators.
The BMXCPS4022S provides power for compatible controller and I/O hardware, supporting communication between the controller and connected equipment.
Water treatment facilities use automation systems to monitor pressure, flow, tank levels, pumps, and filtration equipment.
A stable controller power supply helps maintain the operation of monitoring and control functions. Redundant power arrangements may be considered where system availability is important.
Electrical substations, utility facilities, and energy infrastructure may use industrial controllers for monitoring and control.
The BMXCPS4022S can be used in compatible Modicon X80 installations where the required DC input and redundancy architecture are provided.
The module is designed for supported Modicon M580 safety power supply applications.
In these installations, power supply selection and redundancy configuration must follow the system’s safety architecture. The power supply itself does not independently provide a complete safety function; the overall system design, certified hardware, configuration, and application logic determine the safety capability.
Proper installation is necessary to maintain stable power distribution and ensure compatibility with the Modicon X80 platform.
Before installation, confirm that the available DC source is within the specified 24–48 V DC nominal range and the permitted 18–62.4 V DC operating range.
Check the source’s current capacity and its ability to handle the module’s inrush current. The documented inrush current can reach 60 A, so the upstream supply and protective devices must be selected accordingly.
The BMXCPS4022S is designed for the Modicon X80 platform. Although the product documentation indicates broad backplane compatibility, redundant operation requires a suitable redundant Ethernet backplane and an approved configuration.
Confirm the exact rack type and system architecture before installation, especially when the rack contains M580 safety hardware.
Install the module in its designated power supply position according to the applicable Modicon X80 hardware instructions.
Check that the module is correctly seated and secured. Ensure that ventilation openings are unobstructed and that the cabinet provides sufficient space for heat dissipation.
The IP20 protection rating means the module is intended for installation inside an appropriate electrical enclosure rather than direct exposure to water or dust.
Use the designated input connector for DC supply and protective earth connections. Follow the manufacturer’s terminal identification and wiring requirements.
The module also provides a two-pin alarm relay connection. This can be incorporated into an appropriate monitoring circuit where required.
All wiring should be completed by qualified personnel using suitable conductors and protective devices.
For redundant installations, use two compatible power supply modules in the supported redundant backplane arrangement.
The primary and secondary modules must be installed in their designated positions. Verify that the redundancy indicators operate correctly after startup.
Schneider Electric documentation describes supported redundancy arrangements for the main and extended backplanes. Not every backplane configuration provides identical redundancy management and diagnostic capabilities.
After installation, verify:
Record the installation details and any relevant diagnostic information for future maintenance.
The BMXCPS4022S is used with compatible Modicon X80 automation hardware. The following components illustrate the types of equipment that may be involved in a complete installation.
| Component | Function | Integration Considerations |
|---|---|---|
| Modicon X80 backplane | Provides mechanical mounting and electrical connections | Verify the exact backplane and redundancy support |
| Modicon M580 safety controller | Executes automation and safety-related control functions | Follow the approved safety architecture |
| Modicon X80 I/O modules | Acquire field signals and control output devices | Calculate total backplane power consumption |
| Redundant power supply module | Provides backup power in a supported configuration | Use compatible modules and designated positions |
| DC power source | Supplies the primary 24–48 V DC input | Verify voltage, current capacity, and inrush capability |
| Ethernet backplane | Supports compatible system communication and redundancy functions | Confirm supported configuration |
| Alarm monitoring circuit | Receives power supply alarm information | Use the designated alarm relay connection |
| Control cabinet | Protects installed automation hardware | Maintain suitable ventilation and environmental conditions |
Compatibility should always be confirmed using the exact module references and the system’s hardware documentation. The presence of a component in this table does not mean it is included with the BMXCPS4022S.
When replacing a BMXCPS4022S, the primary input voltage, secondary power requirements, safety-system compatibility, and redundancy functions must be considered.
| Alternative Model | Description | Replacement Considerations |
|---|---|---|
| BMXCPS4022 | Modicon X80 redundant DC power supply | Compare safety-system requirements and exact hardware compatibility |
| BMXCPS4002S | Modicon X80 redundant AC power supply | Uses a different primary input voltage; requires an appropriate AC source |
| BMXCPS3522S | Modicon X80 redundant 125 V DC power supply | Designed for a different DC input voltage class |
| BMXCPS4002 | Modicon X80 AC power supply | Verify redundancy and safety application requirements before substitution |
These models are related products, not automatically interchangeable replacements.
Before selecting an alternative, compare:
For safety-related installations, replacement decisions should follow Schneider Electric’s approved hardware and system documentation.
The BMXCPS4022S supports redundant power supply configurations in compatible Modicon X80 systems. This can improve power availability in installations where uninterrupted controller operation is important.
The module provides 3.3 V DC and 24 V DC secondary power for compatible controller and I/O hardware.
Redundancy information, temperature sensing, remaining-life information, and uptime data help maintenance teams evaluate power supply condition.
Secondary-side overload, overvoltage, and short-circuit protection help protect connected backplane circuits from specified electrical faults.
LED indicators provide visual information about voltage presence, power supply condition, and redundancy status.
The module is designed for the Modicon X80 platform and supported M580 safety architectures, making it suitable for compatible industrial automation installations.
The module has a published net weight of 0.81 kg, allowing it to be incorporated into appropriately designed industrial control cabinets.
The BMXCPS4022S is a redundant DC power supply module from the Modicon X80 series. It provides regulated 3.3 V DC and 24 V DC secondary power for compatible controller and I/O modules.
Its nominal primary input range is 24–48 V DC, with a documented operating voltage limit of 18–62.4 V DC.
The module provides 3.3 V DC for I/O module logic and 24 V DC for compatible I/O module power and processor requirements.
Yes. Two compatible modules can be installed in a supported redundant Ethernet backplane arrangement, with one acting as the primary supply and the other as the secondary supply.
It is designed for supported Modicon M580 safety power supply configurations. The complete system must follow the applicable safety hardware and installation requirements.
The module provides protection against secondary-side overload, overvoltage, and short circuits. Its primary input circuit also has an internal fuse that is not accessible for replacement.
Yes. Available diagnostic information includes redundancy status, redundancy testing, remaining service life, temperature sensing, and uptime duration.
The documented secondary power ratings are 18 W at 3.3 V DC and up to 40 W at 24 V DC under specified loading conditions. The total available power must be evaluated according to the actual output loading.
The manufacturer’s published net weight is approximately 0.81 kg, matching the supplied product listing.
Not as a direct electrical replacement. The BMXCPS4002S uses a 100–240 V AC primary supply, while the BMXCPS4022S uses a 24–48 V DC input. The replacement must match the available power source and the system’s hardware requirements.
When purchasing the Schneider Electric BMXCPS4022S, verify the complete model number and confirm that the product is intended for a Modicon X80 installation requiring a 24–48 V DC redundant power supply.
For replacement projects, compare the primary input voltage, secondary power ratings, backplane compatibility, redundancy requirements, and safety-system configuration. Do not substitute a standard power supply module without checking the system design.
For used or surplus units, inspect the enclosure, electrical connectors, mounting points, and status indicators. Request clear photographs of the product label and confirm the unit’s condition before purchase. Where the application is safety-related, verify the product’s traceability and suitability through the relevant system documentation.
During routine maintenance, inspect the DC input connections, grounding, ventilation, and cabinet temperature. Review the module’s diagnostic information and redundancy status. Any abnormal indication should be investigated before it develops into a wider controller power problem.
For critical installations, verify that the primary and secondary supplies have been installed in the correct positions and that the intended redundancy function is operating correctly. Maintain records of module replacement, diagnostic alarms, and power supply test results.
The Schneider Electric BMXCPS4022S Modicon X80 Redundant Power Supply Module is designed to provide stable DC power to compatible industrial automation controllers and I/O modules. With a 24–48 V DC primary input, 3.3 V DC and 24 V DC secondary outputs, advanced diagnostics, and redundant power supply support, it is an important component in supported Modicon X80 and M580 safety installations.
Its electrical protection functions and diagnostic capabilities help maintenance teams monitor power supply conditions and support reliable automation system operation. For replacement and procurement projects, verifying the exact model, backplane compatibility, input voltage, and safety-system requirements is essential.