Our advantage
Global Logistics
We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.
Brand new and original
Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.
24-hour service
We provide 7*24 hours service to our customers. We will be there whenever you need us.
Price advantage
All our products are priced very favorably because we have our own warehouse and supply.
| Company Information | |||
| [email protected] | |||
| Mobile | +8615980777398 | ||
| +8615980777398 | |||
| 15980777398 |

The Schneider Electric AM0FIP001V000 FIPIO Communication Card is an optional communication interface designed for Schneider Electric Lexium 15 servo drive systems. It enables compatible servo drives to exchange control commands, operating information, and diagnostic data through the FIPIO industrial fieldbus.
FIPIO is an industrial communication bus based on the WorldFIP standard. It was developed to support communication between automation controllers, remote I/O devices, servo drives, and other compatible industrial equipment. By installing the AM0FIP001V000 option card, a supported Lexium 15 servo drive can participate in a FIPIO network instead of operating only through its local control interfaces.
The AM0FIP001V000 supports a communication rate of 1 Mbps and uses a 9-pin male SUB-D connector for its bus connection. It is intended for installations where the control architecture relies on FIPIO communication and compatible Schneider Electric automation equipment.
Within a servo control system, the communication card provides a link between the drive and the wider automation network. A PLC or other compatible controller can use this connection to exchange operating data with the servo drive, coordinate machine movements, and monitor drive status.
The card is an optional communication accessory rather than a standalone controller or servo amplifier. Its operation depends on the host drive, the FIPIO network architecture, compatible connectors and cables, and the software configuration used by the automation system.
Because FIPIO is a legacy industrial communication technology, engineers should verify the existing network configuration and software environment before selecting this card for maintenance or replacement. The complete part number, AM0FIP001V000, should be checked against the installed Lexium 15 equipment.
| Parameter | Specification |
|---|---|
| Brand | Schneider Electric |
| Product Model | AM0FIP001V000 |
| Product Type | FIPIO Communication Card |
| Product Range | Lexium 15 |
| Application | Servo Drive Communication |
| Communication Protocol | FIPIO |
| Protocol Standard | WorldFIP-based industrial fieldbus |
| Communication Speed | 1 Mbps |
| Physical Connector | 9-pin male SUB-D |
| Network Medium | Shielded twisted-pair bus cable |
| Network Function | Exchange of control, operating, and diagnostic data |
| Installation Type | Optional communication card |
| Dimensions Provided | 155 × 25 × 120 mm |
| Weight Provided | 0.14 kg |
| Product Status | Legacy product; service termination date published by Schneider Electric |
Note: Dimensions and weight are the supplied listing values. Confirm the physical card and any mounting bracket or packaging before using these figures for shipping or enclosure calculations.
The AM0FIP001V000 provides the communication interface required for a compatible Lexium 15 servo drive to connect to a FIPIO fieldbus. It allows the drive to exchange information with other devices in the automation system through a structured industrial communication network.
FIPIO is designed for communication between industrial automation devices. It supports the exchange of process information between a controller and compatible network stations.
The AM0FIP001V000 acts as the communication interface at the servo drive. Once correctly installed and configured, it enables the host drive to participate in the FIPIO network and exchange data with the network controller.
The communication speed specified for this card is 1 Mbps. Actual network performance also depends on the network configuration, connected devices, cable installation, and communication cycle settings.
A servo drive requires information from the control system to perform its assigned motion tasks. Through the FIPIO connection, compatible control equipment can exchange relevant operating data with the drive.
Depending on the supported drive configuration and application, exchanged information may include:
The exact data structure and available functions depend on the Lexium drive, its firmware, and the communication configuration.
In a typical FIPIO architecture, a compatible PLC manages network communication and coordinates connected devices. The servo drive operates as a network participant and receives the information required for its assigned machine function.
This arrangement allows motion equipment to be integrated into a centralized control strategy. The PLC can coordinate the servo drive with sensors, conveyors, machine stations, and other automation components.
The AM0FIP001V000 does not replace the PLC or perform independent machine sequencing. Its purpose is to provide the communication interface between the host drive and the FIPIO network.
Communication between the servo drive and the automation system can help maintenance personnel access operating information and identify abnormal conditions.
Depending on the installed system and software tools, drive status and diagnostic information can be used to investigate communication interruptions, drive faults, and machine-control problems.
Reliable diagnosis requires checking both the communication network and the servo drive itself. A network fault may originate from cabling, termination, addressing, configuration, or another connected device rather than from the option card.
The AM0FIP001V000 is designed to connect a compatible Lexium 15 servo drive to a FIPIO-based automation architecture. Its role is particularly relevant in older Schneider Electric installations where servo motion and PLC control are coordinated through the same fieldbus.
A PLC can coordinate the operation of multiple devices within a machine. When a compatible Lexium 15 drive is connected through FIPIO, the controller can exchange the information required for coordinated machine operation.
For example, a packaging machine may use servo drives for product positioning while a PLC manages sensors, machine interlocks, and production sequencing.
The communication card supports the data exchange required by this architecture, while the servo drive remains responsible for its own motor-control functions.
Servo systems often require more than basic start and stop commands. They may need speed references, position-related information, operating-mode selection, and status feedback.
The AM0FIP001V000 provides the FIPIO communication path through which supported Lexium 15 systems can exchange motion-related information with the automation controller.
The actual motion functions depend on the drive configuration and the application software. Engineers should confirm that the required operating modes and data objects are supported by the specific installation.
Connecting servo drives to a common automation network can simplify the exchange of operating and diagnostic information.
A compatible controller or engineering environment can use this information to support troubleshooting and maintenance. This can be useful in production systems where several servo-driven machine sections must operate together.
The AM0FIP001V000 is primarily associated with Lexium 15 servo drive installations that use FIPIO communication. Its applications are therefore determined by the host servo drive and the design of the machine-control system.
Packaging equipment frequently uses servo motors for feeding, positioning, cutting, sealing, and product handling. FIPIO communication can connect compatible servo drives to the machine’s control architecture.
The communication card helps integrate the servo drive into the wider production sequence, allowing the controller to exchange commands and operating information.
Automated material-handling equipment may use servo-driven mechanisms for accurate positioning and synchronized movement.
A compatible FIPIO-connected servo drive can participate in the machine’s control network, supporting coordination with conveyors, transfer stations, and other equipment.
Assembly equipment often combines multiple motion axes with sensors and mechanical actuators. Communication between the PLC and servo drives helps coordinate movement sequences and machine timing.
The AM0FIP001V000 provides the fieldbus interface for supported Lexium 15 installations that use this communication architecture.
Printing and converting machinery may require coordinated motor operation across feeding, tension-control, and processing sections.
In legacy systems using Lexium 15 servo drives and FIPIO, the communication card can provide the connection needed for drive-level data exchange with the automation controller.
Many industrial facilities continue operating established automation equipment because the machinery remains mechanically and operationally suitable for production.
In these installations, maintaining the original communication architecture can reduce the need for extensive control-system modifications. The AM0FIP001V000 may therefore be relevant when repairing or restoring an existing FIPIO-based Lexium 15 system.
Correct installation and configuration are necessary for reliable communication between the servo drive and the FIPIO network.
Before installation, confirm that the host equipment is a compatible Lexium 15 servo drive designed to accept the AM0FIP001V000 option card.
Do not assume that the card is compatible with every Schneider Electric servo drive or other automation product simply because they support industrial communication.
Check the drive’s hardware documentation, option-card requirements, and firmware compatibility.
Install the card in the designated option-card position according to the host drive’s instructions.
Before opening the drive or handling the card, isolate the equipment from the power supply and follow the required electrical safety procedures. Observe electrostatic discharge precautions when handling electronic circuit boards.
Ensure that the card is fully seated and that its connectors are not damaged.
The card uses a 9-pin male SUB-D connector. The appropriate FIPIO connector and bus cable must be selected for the network layout.
Schneider Electric FIPIO installations may use dedicated connectors and accessories such as TSX FP ACC series connection devices. The exact connector and wiring arrangement should be checked against the installed network design.
Use the specified shielded twisted-pair cable and follow the network’s grounding and shielding recommendations.
The communication system must be configured so that the controller and connected devices recognize the correct network stations.
Configuration work may include:
The supported configuration procedure depends on the PLC platform, software version, and Lexium 15 installation.
FIPIO network reliability depends on correct cable installation and termination.
Check the cable route, connector condition, shielding, grounding, and termination at the network ends. Incorrect termination or damaged cable sections may cause intermittent communication or prevent the drive from joining the network.
Avoid unnecessary cable branches and follow the permitted topology and distance requirements for the specific installation.
After installation, power up the system according to the equipment procedures and verify that the controller recognizes the servo drive.
Check communication status, drive diagnostics, operating data, and the response to control commands. Test the system under controlled conditions before returning the machine to normal production.
Record the network configuration and relevant drive parameters for future maintenance.
The AM0FIP001V000 operates as part of a FIPIO-based Lexium 15 servo control system. The following components may be relevant to a typical installation.
| Component | Function | Integration Considerations |
|---|---|---|
| Schneider Electric Lexium 15 servo drive | Hosts the communication option card and controls the servo motor | Verify exact drive compatibility |
| Schneider Electric Premium PLC | Manages control logic and compatible FIPIO network communication | Confirm supported processor and communication configuration |
| FIPIO bus cable | Provides the physical communication medium | Use the specified shielded cable type |
| TSX FP ACC2 connector | Provides a FIPIO bus connection interface | Confirm connector type and network arrangement |
| TSX FP ACC12 connector | Supports specified FIPIO connection arrangements | Follow the relevant hardware installation instructions |
| FIPIO termination accessories | Maintain correct network electrical characteristics | Install according to the network topology |
| Servo motor | Converts drive output into mechanical motion | Match motor and drive ratings |
| Engineering software | Supports configuration, commissioning, and diagnostics | Confirm compatibility with the installed PLC and drive generation |
These components are examples of equipment used in compatible installations. They are not necessarily supplied with the AM0FIP001V000 card.
The AM0FIP001V000 is a specific FIPIO option card for the Lexium 15 range. It should not be replaced with another communication card simply because the alternative has a similar connector or supports an industrial fieldbus.
| Alternative or Related Option | Consideration |
|---|---|
| Another AM0FIP001V000 card | The most direct option for maintaining the original configuration |
| Schneider Electric Lexium communication options | Different communication cards may support other protocols and require different host-drive compatibility |
| Modbus communication option | Suitable only where the host drive and control architecture support the corresponding interface |
| Profibus DP communication option | Requires a compatible drive option and Profibus network configuration |
| Ethernet communication option | May be considered for a redesigned system, but is not a direct FIPIO replacement |
| Modern servo drive with current network support | May be appropriate for a wider modernization project involving controller and software changes |
Before selecting an alternative, check:
If the existing PLC system depends on FIPIO, replacing the card with an Ethernet or Modbus option may require changes to the PLC hardware, control program, network wiring, and commissioning procedures.
The card provides a communication interface specifically intended for compatible Lexium 15 servo drive installations using the FIPIO fieldbus.
Its specified communication rate supports data exchange within compatible FIPIO networks.
The male SUB-D connector provides a defined physical connection for the FIPIO bus cabling system.
The card allows supported servo drives to participate in a centralized automation architecture, helping coordinate motion equipment with the machine controller.
The communication interface supports the exchange of operating and diagnostic information available through the configured host drive.
For existing production lines using Lexium 15 and FIPIO, retaining the original communication interface may help avoid unnecessary changes to the established control architecture.
It is an optional FIPIO communication card designed for compatible Schneider Electric Lexium 15 servo drives. It provides the fieldbus interface required for communication with compatible automation equipment.
The AM0FIP001V000 supports FIPIO, an industrial fieldbus based on the WorldFIP standard.
The specified communication rate is 1 Mbps.
It uses a 9-pin male SUB-D connector for the FIPIO bus connection.
No. Compatibility depends on the FIPIO network architecture, the PLC platform, the host servo drive, and the available configuration software. Confirm the complete system compatibility before installation.
No. It is an optional communication interface. It does not independently control a servo motor or replace the PLC and servo drive.
The FIPIO network uses a specified shielded twisted-pair cable system. Cable type, connectors, termination, and network layout should follow the installation documentation.
Not as a direct substitution. A different communication protocol may require a compatible drive option, different wiring, PLC program changes, and network reconfiguration.
Verify the complete reference AM0FIP001V000, physical condition, connector condition, card compatibility with the host Lexium 15 drive, and whether the unit has been tested. For refurbished equipment, request available inspection or functional-test information.
Schneider Electric lists December 15, 2025, as the service termination date for this reference. Buyers maintaining existing systems should confirm current repair, spare-parts, and technical-support availability directly with the relevant service channel.
The AM0FIP001V000 is a legacy communication option, so procurement should focus on exact model identification and compatibility with the existing Lexium 15 installation.
Before ordering, compare the reference printed on the existing card with the required replacement. Check the host drive model, connector condition, card dimensions, and available installation documentation. A communication card from another Lexium product family should not be treated as equivalent without technical confirmation.
For new-surplus or refurbished units, request clear photographs of the front and rear of the card, its connector, and its identification label. Confirm the condition, test status, warranty terms, and return policy before purchasing.
During maintenance, inspect the card connection, bus connector, shielded cable, grounding, and network termination. Communication faults should be investigated across the entire network rather than assuming the option card is the only possible cause.
For long-term equipment planning, document the existing FIPIO architecture, connected devices, PLC configuration, and servo parameters. If a modernization project is planned, evaluate the replacement of the communication architecture as a complete system rather than changing only the option card.
The Schneider Electric AM0FIP001V000 FIPIO Communication Card is an optional communication interface for compatible Lexium 15 servo drives. Supporting a 1 Mbps FIPIO connection through a 9-pin male SUB-D connector, it enables the servo drive to exchange control, operating, and diagnostic information with compatible industrial automation equipment.
For maintenance teams working with legacy Lexium 15 systems, the card is relevant to preserving the original FIPIO communication architecture. Accurate part-number verification, host-drive compatibility checks, correct bus wiring, and careful commissioning are essential when sourcing or replacing this component.