• Schneider NS1250NA Circuit Breaker
  • Schneider NS1250NA Circuit Breaker
  • Schneider NS1250NA Circuit Breaker
  • Schneider NS1250NA Circuit Breaker
Product Overview The Schneider Electric NS1250NA ComPacT NS Switch Disconnector is a low-voltage power distribution device designed for switching and isolating electrical circuits in industrial and comm……
Schneider NS1250NA Circuit Breaker
  • Schneider
  • NS1250NA
  • Circuit Breaker
  • France
  • 327 x 210 x 147 mm
  • 14 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 25

Our advantage

Schneider NS1250NA Circuit Breaker

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Schneider NS1250NA Circuit Breaker

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Schneider NS1250NA Circuit Breaker

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Schneider NS1250NA Circuit Breaker

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Schneider Electric NS1250NA ComPacT NS Switch Disconnector is a low-voltage power distribution device designed for switching and isolating electrical circuits in industrial and commercial installations. With a rated operational current of 1250 A and an operational voltage of up to 690 V AC, it is intended for applications involving high-current distribution systems and industrial switchboards.

The NS1250NA belongs to the Schneider Electric ComPacT NS product family. It provides a means of manually or mechanically operating a power circuit and establishing an isolation condition for maintenance and electrical distribution purposes. Its switching function makes it suitable for main distribution sections, industrial power panels, and other installations where a high-current isolation device is required.

An important distinction is that the NS1250NA is a switch disconnector, not a conventional circuit breaker with integrated overload and short-circuit trip protection. Its primary function is switching and isolation. Where automatic overcurrent protection is required, the electrical system must include a suitably rated protective device designed for that purpose.

The NS1250NA is designed for three-phase or four-pole configurations depending on the selected product reference. The three-pole fixed configuration is commonly used in three-phase distribution systems. Its rated operational current is 1250 A, and its rated operational voltage reaches 690 V AC at 50/60 Hz.

The device is designed for installation in industrial switchboards and distribution assemblies. Its mechanical construction supports high-current connections, while its switching mechanism provides a controlled means of operating the electrical circuit.

For replacement projects, the exact pole configuration, mounting arrangement, operating mechanism, terminal arrangement, and accessory combination should be checked before ordering. Products within the ComPacT NS family may have similar external appearances but different electrical and mechanical characteristics.

Technical Specifications

Parameter Specification
Brand Schneider Electric
Product Series ComPacT NS
Model NS1250NA
Product Type Switch Disconnector
Device Application Electrical Power Distribution
Rated Operational Current 1250 A
Rated Operational Voltage Up to 690 V AC
Rated Frequency 50/60 Hz
Pole Configuration 3P configuration referenced by supplied dimensions
Mounting Type Fixed
Operating Mechanism Manual operation, depending on selected reference
Rated Insulation Voltage 800 V AC
Rated Impulse Withstand Voltage 8 kV
Rated Short-Time Withstand Current 25 kA for 0.5 seconds
Rated Short-Circuit Making Capacity 52 kA at 690 V AC
Standard IEC 60947-3
Suitability for Isolation Yes
Dimensions Provided 327 × 210 × 147 mm
Weight Provided 14 kg
Typical Application Industrial Power Distribution and Circuit Isolation

Important: These specifications describe the three-pole fixed configuration corresponding to the supplied dimensions and weight. Four-pole versions and electrically operated configurations may have different dimensions, weights, and accessory requirements. Confirm the complete product reference before installation.

Function and Working Principle

The NS1250NA is designed to control the connection and disconnection of high-current electrical circuits. It provides a mechanical switching function that allows an operator to change the state of a power circuit.

1. Electrical Circuit Switching

The primary function of the NS1250NA is to open or close an electrical circuit through its switching mechanism.

When the device is in the closed position, its main contacts provide an electrical path for current to flow through the distribution system. When operated to the open position, the contacts separate and interrupt the normal current path within the device’s specified switching capabilities.

The device is rated for industrial power distribution applications with an operational current of 1250 A.

2. Circuit Isolation

Isolation is important during equipment inspection, maintenance, and repair. The NS1250NA is designed to provide an isolation function in accordance with the applicable product standard.

When correctly installed and operated, it allows the relevant electrical circuit to be disconnected from its supply. However, the isolation procedure must also account for other possible energy sources, backfeeds, stored electrical energy, and auxiliary circuits.

The device’s isolation function does not replace the need for lockout/tagout procedures or verification that the circuit is de-energized.

3. High-Current Distribution

Industrial power distribution systems often supply large motors, production lines, and multiple downstream electrical loads. The NS1250NA is designed for circuits with a rated operational current of 1250 A.

Its main current-carrying components and terminal connections must be installed according to the manufacturer’s requirements. Correct conductor sizing, terminal preparation, tightening torque, and thermal management are essential for reliable operation.

4. Mechanical Operating Mechanism

The switching mechanism transfers the operator’s action to the internal contact system. Depending on the exact product reference, the device may use a manual toggle mechanism or an electrically operated mechanism.

The operating arrangement should be verified before ordering replacement equipment. A manually operated unit and a motor-operated unit are not automatically interchangeable.

5. Switching and Protection Are Different Functions

The NS1250NA should not be confused with a protective circuit breaker.

A circuit breaker equipped with an appropriate trip unit can automatically interrupt a circuit when specified overload or short-circuit conditions occur. A switch disconnector primarily provides switching and isolation functions.

For this reason, an NS1250NA installation must be designed with suitable upstream or associated overcurrent protection. The protective device must be coordinated with the electrical system’s rated current, prospective fault current, conductor capacity, and applicable safety requirements.

Role in Industrial Power Distribution Systems

The NS1250NA can be used as part of a low-voltage distribution assembly where high-current switching and isolation are required.

Main Distribution Panel

In a main distribution panel, a switch disconnector can provide a means of connecting or isolating a major electrical section. It may be installed in a distribution assembly serving several downstream circuits.

Its 1250 A operational rating makes it relevant to high-current distribution applications where the electrical design requires a suitably rated switching device.

Industrial Switchboards

Industrial switchboards distribute electrical power to production equipment, motor control centers, auxiliary systems, and building services.

The NS1250NA can form part of the switching arrangement within such assemblies. Its suitability depends on the switchboard design, rated current, fault withstand requirements, and connection configuration.

Maintenance Isolation

Maintenance personnel may need to isolate a distribution section before working on downstream equipment.

The NS1250NA can provide a designated switching and isolation point when incorporated into a correctly designed electrical installation. Isolation must always be verified using appropriate procedures and test equipment.

Integration with Protective Devices

A switch disconnector is normally used alongside suitable protective devices when the installation requires automatic fault interruption.

The complete distribution design should coordinate the switch disconnector, circuit breaker or fuse protection, busbars, cables, and downstream equipment. The protection device must have an adequate interrupting rating for the available fault current.

Industrial Applications

1. Main Low-Voltage Distribution Systems

Large industrial facilities require reliable switching arrangements for distributing electrical power between incoming supplies and downstream distribution sections.

The NS1250NA can be considered for suitable 1250 A distribution applications where a switch disconnector is required.

2. Manufacturing Facilities

Manufacturing plants often contain multiple production areas supplied through centralized electrical distribution panels.

A high-current isolation device can provide a switching point for a designated distribution section, supporting maintenance planning and electrical system organization.

3. Industrial Switchgear Assemblies

Switchgear assemblies contain switching devices, protective equipment, busbars, terminals, and monitoring components.

The NS1250NA may be installed within a compatible assembly when the mechanical dimensions, current rating, pole arrangement, and connection requirements are satisfied.

4. Motor Control Centers

Motor control centers distribute power to multiple motor feeders and associated control equipment.

A switch disconnector may be used as part of a main or sectional isolation arrangement. Motor branch protection must still be provided by appropriately selected protective devices.

5. Utility and Infrastructure Distribution

Electrical infrastructure installations may require high-current switching and isolation devices in distribution assemblies.

The NS1250NA can be evaluated for applications within its specified voltage, current, and operating conditions. Environmental requirements, system fault levels, and installation standards must be checked before selection.

6. Commercial and Industrial Electrical Rooms

Large commercial facilities, processing plants, and industrial buildings may use high-current distribution panels to supply major electrical loads.

The NS1250NA can serve as a switching and isolation component where its technical ratings and mechanical configuration match the panel design.

Installation and System Integration

Correct installation is essential for electrical safety and reliable long-term operation.

1. Verify the Product Configuration

Before installation, confirm that the device is the correct NS1250NA reference and that its pole configuration matches the electrical system.

Check whether the unit is:

  • Three-pole or four-pole.
  • Fixed-mounted or withdrawable.
  • Manually operated or electrically operated.
  • Supplied as a basic device or a complete assembly.
  • Equipped with the required terminals and accessories.

The supplied dimensions of 327 × 210 × 147 mm and weight of 14 kg correspond to the referenced three-pole configuration. Four-pole versions have different physical dimensions.

2. Check Electrical Ratings

Verify the system voltage, frequency, rated current, and expected operating conditions.

The NS1250NA has a rated operational current of 1250 A and a maximum rated operational voltage of 690 V AC. The installation must remain within the device’s published operating limits.

The short-time withstand and making-capacity ratings must also be considered when evaluating the device for a particular distribution system.

3. Confirm Short-Circuit Protection

The NS1250NA is a switch disconnector and should not be treated as a substitute for an automatic protective circuit breaker.

The installation must include suitable overcurrent and short-circuit protection. Protective-device selection should consider the prospective short-circuit current, cable capacity, busbar ratings, coordination requirements, and applicable electrical regulations.

4. Mechanical Mounting

Install the device on a compatible support or chassis according to the manufacturer’s mounting instructions.

Check the mounting position, operating access, terminal clearance, and required space for cable connections. Ensure that the switchboard structure can support the device’s weight and mechanical operating forces.

5. Electrical Connections

Use conductors and connection hardware suitable for the rated current and installation conditions.

Check terminal preparation, contact surfaces, cable arrangement, tightening torque, and phase identification. Poor connections can increase contact resistance and create excessive heat.

All electrical work should be performed by qualified personnel using the appropriate safety procedures.

6. Commissioning and Functional Checks

Before energizing the system:

  • Confirm the device’s catalog number and pole configuration.
  • Inspect the enclosure, terminals, and visible mechanical components.
  • Verify mounting security.
  • Check conductor connections and protective-device coordination.
  • Confirm the operating mechanism functions correctly.
  • Verify that the open and closed positions are correctly indicated.
  • Confirm the isolation procedure and associated safety controls.

Commissioning should follow the manufacturer’s instructions and the site’s electrical safety procedures.

Compatible System Components

The NS1250NA is normally integrated into a larger electrical distribution assembly. The following components may be used in the same installation, subject to engineering verification.

Component Function Integration Considerations
Low-voltage busbars Distribute current between electrical sections Verify current rating, short-circuit withstand, and connection compatibility
Circuit breaker Provides automatic overload and short-circuit protection Select a suitable protective device and coordinate it with the switch disconnector
Fuse protection Provides overcurrent and short-circuit protection Confirm fuse type, rating, and coordination requirements
Distribution panel Houses switching and protective equipment Check mechanical dimensions, clearances, and heat dissipation
Cable connections Connect the device to the distribution network Verify conductor size, terminal arrangement, and tightening torque
Auxiliary contacts Provide device-position status where supported Confirm compatible accessory reference and wiring requirements
Electrical operating accessories Support remote operation where available Check the exact device version and accessory compatibility
Monitoring equipment Measures electrical operating conditions Select appropriate current and voltage measurement equipment
Earthing system Provides protective grounding Follow the installation’s grounding and bonding design

Accessories should be selected according to the exact NS1250NA reference. Do not assume that accessories intended for another ComPacT NS model will fit or operate correctly.

Alternative Models and Replacement Considerations

When replacing an NS1250NA, the most important consideration is to identify the device’s switching and isolation function correctly.

A circuit breaker with a similar current rating is not automatically a direct substitute because it may have different protection functions, dimensions, connection arrangements, and operating mechanisms.

Alternative or Related Product Replacement Considerations
Another ComPacT NS1250NA configuration Verify pole count, mounting arrangement, operating mechanism, and connection options
ComPacT NS1250N circuit breaker Different device function; includes a circuit-breaker configuration and requires protection and coordination review
ComPacT NS1000NA Lower current rating; not a direct replacement for a 1250 A application without system redesign
ComPacT NS1600NA Higher current rating; installation compatibility and protection coordination must be assessed
Other Schneider Electric switch disconnectors Compare rated current, operational voltage, isolation capability, short-time withstand, and mechanical dimensions

Before selecting a replacement, compare:

  • Product type: switch disconnector or circuit breaker.
  • Rated operational current.
  • Rated operational voltage.
  • Number of poles.
  • Rated insulation voltage.
  • Rated impulse withstand voltage.
  • Short-time withstand current.
  • Short-circuit making capacity.
  • Fixed or withdrawable mounting.
  • Manual or electrical operating mechanism.
  • Terminal and busbar arrangement.
  • Dimensions and installation clearances.
  • Auxiliary contacts and optional accessories.

The replacement should be approved by a qualified electrical engineer based on the complete distribution-system design.

Key Advantages

High-Current Switching Capability

The NS1250NA is rated for 1250 A operational current, making it suitable for appropriately designed high-current distribution applications.

Industrial Isolation Function

Its switch-disconnector design provides a means of disconnecting and isolating electrical distribution circuits for maintenance and operational purposes.

690 V AC Operational Voltage

The device supports electrical distribution applications with operational voltages up to 690 V AC, subject to the specified operating category and installation conditions.

Industrial Mechanical Construction

The ComPacT NS platform is designed for installation in industrial switchboards and distribution assemblies.

Defined Isolation Standard

The NS1250NA is designed in accordance with IEC 60947-3, which covers switches, disconnectors, switch-disconnectors, and fuse-combination units.

Flexible Installation Options

Different product configurations are available within the NS1250NA range. Pole count, operating mechanism, mounting arrangement, and connection configuration can be selected according to the system design.

Technical FAQs

1. What is the Schneider Electric NS1250NA?

The Schneider Electric NS1250NA is a ComPacT NS switch disconnector designed for high-current electrical distribution and isolation applications. Its rated operational current is 1250 A.

2. Is NS1250NA a circuit breaker?

No. The NS1250NA is a switch disconnector. It provides switching and isolation functions but should not be treated as a conventional circuit breaker with integrated automatic overload and short-circuit trip protection.

3. What is the rated current of NS1250NA?

Its rated operational current is 1250 A. The actual permissible operating current depends on the selected configuration and applicable operating conditions.

4. What is the maximum rated operational voltage?

The device is rated for operational voltages up to 690 V AC at 50/60 Hz, subject to its specified utilization category and installation requirements.

5. How many poles does the NS1250NA have?

The product family includes three-pole and four-pole configurations. The supplied dimensions of 327 × 210 × 147 mm and weight of 14 kg correspond to the three-pole configuration.

6. What standard does the NS1250NA comply with?

The NS1250NA switch disconnector is designed to comply with IEC 60947-3, the standard covering switches, disconnectors, switch-disconnectors, and fuse-combination units.

7. Can NS1250NA provide short-circuit protection?

It should not be used as a substitute for a protective circuit breaker. A suitable circuit breaker or fuse arrangement must provide the required automatic overcurrent and short-circuit protection.

8. Can the NS1250NA be used in a 1250 A distribution panel?

It can be considered for a 1250 A distribution application when the system voltage, utilization category, short-time withstand requirements, connections, and installation conditions are compatible.

9. What should be checked before replacing an NS1250NA?

Check the complete product reference, pole count, mounting arrangement, operating mechanism, terminal configuration, current rating, voltage rating, and accessory requirements. Also verify that the replacement performs the same switching and isolation function.

10. Is a three-pole NS1250NA interchangeable with a four-pole version?

No, not automatically. Four-pole versions have different dimensions and connection arrangements. The neutral-pole requirements and switchboard layout must be considered before selecting a replacement.

Procurement and Maintenance Recommendations

When purchasing the Schneider Electric NS1250NA, first confirm that the required device is a switch disconnector rather than a circuit breaker. This distinction is important because the two product types perform different functions within an electrical distribution system.

Check the complete catalog reference and verify the pole configuration, operating mechanism, mounting arrangement, terminal connections, and included accessories. For the three-pole fixed configuration described here, the supplied dimensions are 327 × 210 × 147 mm and the weight is 14 kg.

For replacement or surplus equipment, request clear photographs of the nameplate, terminals, operating mechanism, and overall device condition. Confirm whether the unit is supplied as a basic switch disconnector or a complete assembly with the required connection accessories.

During maintenance, inspect mechanical operation, contact condition, terminal connections, and signs of overheating or abnormal wear according to the manufacturer’s maintenance requirements. Any abnormal noise, mechanical resistance, or evidence of thermal damage should be investigated by qualified personnel.

Electrical isolation must always be performed using approved procedures. Before maintenance begins, verify the absence of voltage and account for possible backfeed sources and stored energy.

For critical distribution installations, maintain accurate equipment records, including the product reference, pole configuration, installation date, inspection history, and associated protective-device settings.

Conclusion

The Schneider Electric NS1250NA ComPacT NS Switch Disconnector is a high-current switching and isolation device designed for industrial low-voltage power distribution. With a rated operational current of 1250 A and an operational voltage of up to 690 V AC, it can be used in appropriately engineered distribution panels and switchboard assemblies.

Its primary role is to provide controlled circuit switching and isolation, not automatic overload and short-circuit protection. Correct selection therefore requires coordination with suitable protective devices and verification of the complete electrical installation.

For maintenance, replacement, and procurement projects, checking the exact pole configuration, operating mechanism, mounting arrangement, and connection requirements is essential to ensure compatibility and safe operation.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501