• Schneider NS1250H Circuit Breaker
  • Schneider NS1250H Circuit Breaker
  • Schneider NS1250H Circuit Breaker
  • Schneider NS1250H Circuit Breaker
Product Overview The Schneider Electric NS1250H ComPact NS Circuit Breaker is a high-current circuit protection device designed for industrial power distribution systems, large electrical panels, and co……
Schneider NS1250H Circuit Breaker
  • Schneider
  • NS1250H
  • Circuit Breaker
  • France
  • 224 x 210 x 182 mm
  • 14 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 26

Our advantage

Schneider NS1250H Circuit Breaker

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Schneider NS1250H Circuit Breaker

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Schneider NS1250H Circuit Breaker

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Schneider NS1250H Circuit Breaker

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Schneider Electric NS1250H ComPact NS Circuit Breaker is a high-current circuit protection device designed for industrial power distribution systems, large electrical panels, and commercial power infrastructure. Belonging to the ComPact NS630b–1600 family, it is designed to protect electrical installations against overloads and short-circuit faults while providing a means of switching and isolating electrical circuits.

With a rated current of 1250 A, the NS1250H is intended for applications where substantial electrical loads must be supplied and protected. It can be used in main distribution boards, industrial switchboards, power control centers, and other installations requiring high-capacity circuit protection.

The H breaking-capacity class provides a high short-circuit interruption capability. For the 380/415 V AC operating range, the published rated ultimate short-circuit breaking capacity is 70 kA. This capability is important in installations where the available fault current may be significant and the protective device must interrupt abnormal current conditions safely.

The ComPact NS platform is designed around industrial power distribution requirements. Depending on the selected configuration, the breaker can be supplied with different pole arrangements, operating mechanisms, mounting methods, and electronic trip units. MicroLogic trip units provide electronic protection functions, while other configurations may have different protection and control arrangements.

The NS1250H designation identifies the breaker family and breaking-capacity class, but it does not fully identify every installed option. Buyers should verify the complete catalog number, pole configuration, trip unit, operating mechanism, and mounting arrangement before ordering a replacement.

For industrial maintenance teams, the NS1250H is relevant to installations where reliable power distribution and coordinated electrical protection are essential. Correct selection and commissioning help maintain system reliability and reduce the consequences of electrical faults.

Technical Specifications

Parameter Specification
Brand Schneider Electric
Product Series ComPact NS
Model NS1250H
Product Type Circuit Breaker
Application Electrical Power Distribution
Rated Current 1250 A
Rated Operational Voltage Up to 690 V AC
Operating Frequency 50/60 Hz
Breaking Capacity Class H
Ultimate Breaking Capacity at 380/415 V AC 70 kA
Ultimate Breaking Capacity at 440 V AC 65 kA
Ultimate Breaking Capacity at 500/525 V AC 50 kA
Ultimate Breaking Capacity at 660/690 V AC 42 kA
Rated Insulation Voltage Configuration-dependent; commonly 800 V or 1000 V AC
Trip Unit Configuration-dependent; MicroLogic options available
Trip Unit Technology Electronic, where equipped
Pole Configuration Verify exact unit; 3P and 4P versions exist
Mounting Arrangement Fixed or withdrawable, depending on version
Control Method Manual or electrical, depending on version
Dimensions Provided 224 × 210 × 182 mm
Weight Provided 14 kg
Typical Installation Industrial switchboards and power distribution panels

Important: The NS1250H is available in different configurations. The specifications above describe the product family and the supplied listing information. Verify the exact catalog number and nameplate before treating pole count, trip unit, insulation rating, or mounting method as confirmed.

Function and Working Principle

The Schneider NS1250H is designed to protect electrical distribution circuits by detecting abnormal current conditions and interrupting the circuit when the configured protection thresholds are exceeded.

Its operation combines current detection, trip-unit decision-making, and a mechanical switching mechanism.

1. Overload Protection

An overload occurs when a circuit carries more current than its intended operating level for a sustained period. Excessive current can cause conductors, terminals, and connected equipment to overheat.

When equipped with a suitable protection unit, the NS1250H can detect overload conditions and initiate a trip according to the configured protection characteristics.

The protection settings must be coordinated with conductor ampacity, transformer capacity, downstream equipment, and the overall distribution design.

2. Short-Circuit Protection

A short circuit can produce a very high current within a short period. If it is not interrupted promptly, the resulting thermal and electrodynamic forces can damage electrical equipment.

The NS1250H belongs to the H breaking-capacity class. Its published 70 kA ultimate breaking capacity at 380/415 V AC makes it suitable for appropriately engineered distribution systems with high prospective fault-current levels.

The actual suitability must be established through a short-circuit study and coordination assessment. The breaker must not be selected solely because its interrupting rating appears high.

3. Electronic Trip Unit Operation

Depending on the selected configuration, the NS1250H can be equipped with a MicroLogic electronic trip unit.

Electronic trip units measure current and evaluate it against configured protection thresholds. When an abnormal condition meets the trip criteria, the unit activates the circuit breaker’s trip mechanism.

Some MicroLogic versions provide long-time and instantaneous protection, while more advanced versions may offer additional short-time and ground-fault functions. The actual protection functions depend on the installed trip-unit model.

4. Arc Interruption

When the breaker opens under fault conditions, an electrical arc may form between the separating contacts. The circuit breaker’s internal arc-control and interruption system is designed to extinguish this arc and interrupt the current.

The rated breaking capacity indicates the maximum fault-current level the breaker can interrupt under specified test conditions. It should not be confused with the normal operating current rating.

5. Switching and Isolation

The NS1250H can also be used for switching and circuit isolation, subject to the exact configuration and applicable electrical standards.

Before maintenance, the circuit must be isolated using the approved procedure. A breaker handle position alone should not be treated as proof that all hazardous electrical energy has been removed. Appropriate verification and lockout procedures remain necessary.

Role in Industrial Power Distribution Systems

The NS1250H can serve as a main or feeder protection device in industrial electrical distribution systems. Its position depends on the distribution architecture and the protection coordination study.

Main Distribution Protection

In a main distribution board, a high-current breaker may protect an incoming supply or a major distribution section. The NS1250H’s 1250 A rating makes it suitable for consideration in installations with corresponding load and fault-current requirements.

The main protective device must be coordinated with upstream transformer protection and downstream feeder breakers.

Feeder Circuit Protection

The breaker can also be used to protect a high-capacity outgoing feeder supplying production equipment, motor control centers, or secondary distribution panels.

Proper protection coordination helps ensure that a fault on one feeder does not unnecessarily interrupt power to unrelated sections of the facility.

Integration with Power Monitoring Systems

When equipped with compatible electronic trip and communication accessories, the breaker may form part of a broader power monitoring and management system.

Depending on the installed options, available information may include protection status, trip indications, and electrical measurements. Communication capability should be verified from the complete accessory and trip-unit configuration.

Electrical System Reliability

A properly selected circuit breaker helps limit the effects of overloads and short circuits. It also provides a controlled switching point for maintenance and system operation.

However, the breaker is only one part of the protection system. Transformers, cables, busbars, protective relays, grounding arrangements, and downstream devices must all be considered.

Industrial Applications

1. Main Low-Voltage Distribution Boards

Large manufacturing facilities use main distribution boards to receive and distribute electrical power to different production areas.

A 1250 A breaker may be used as an incoming or outgoing protective device when the electrical design and fault-current calculations support its selection.

2. Industrial Power Control Centers

Power control centers supply multiple electrical loads through individual feeders. The NS1250H can be considered for high-capacity feeder protection where the current rating and breaking capacity meet system requirements.

3. Manufacturing Plants

Manufacturing facilities often operate multiple production lines, large auxiliary systems, and high-power equipment. A suitable high-capacity breaker helps protect the distribution circuits supplying these loads.

Applications may include metal processing, automotive manufacturing, industrial assembly, and other facilities with substantial electrical demand.

4. Water and Wastewater Treatment Facilities

Large treatment plants use pumps, blowers, electrical control panels, and auxiliary distribution systems. High-current circuit breakers may be used to protect major distribution sections supplying these installations.

The breaker selection must account for motor starting conditions, load diversity, fault-current levels, and the protection requirements of the facility.

5. Commercial and Infrastructure Buildings

Large commercial buildings and infrastructure facilities may require high-capacity distribution protection for major electrical panels.

The NS1250H may be considered where its voltage, current, interruption rating, and installation configuration meet the project requirements.

6. Power Distribution and Utility-Related Installations

Industrial substations and distribution facilities use high-capacity low-voltage breakers to protect downstream equipment and distribution sections.

In these environments, coordination with upstream protective devices and downstream feeders is particularly important.

Installation and System Integration

The NS1250H is a high-current protective device. Installation must be performed by qualified electrical personnel following the manufacturer’s instructions and applicable electrical regulations.

1. Verify the Electrical Ratings

Before installation, confirm the system’s nominal voltage, frequency, rated current, and prospective short-circuit current.

The NS1250H has a published operational voltage of up to 690 V AC and a rated current of 1250 A. Its 70 kA H-class breaking capacity at 380/415 V AC must be evaluated against the actual fault-current level at the installation point.

Do not assume that the 70 kA rating applies equally at every voltage. The breaking capacity varies with operating voltage.

2. Confirm the Pole Configuration

The ComPact NS1250H family includes both 3-pole and 4-pole configurations.

A three-pole breaker is generally used in three-phase circuits without a switched neutral, while a four-pole version can also switch the neutral conductor when required by the system design.

The replacement must match the original circuit arrangement and the applicable neutral-switching requirements.

3. Check the Trip Unit

Confirm the exact MicroLogic model, current rating, protection functions, and adjustment range.

A replacement breaker with a different trip unit may have different protection characteristics. Settings should be reviewed against the electrical coordination study before energizing the installation.

4. Confirm Mounting and Dimensions

The supplied dimensions are 224 × 210 × 182 mm. Verify these values against the exact breaker configuration and manufacturer’s dimensional drawing.

Fixed and withdrawable versions may have substantially different installation dimensions and mounting requirements. Allow adequate space for cable connections, operating access, ventilation, and maintenance.

5. Verify Busbar and Cable Connections

High-current connections require suitable conductors, busbars, terminals, and connection hardware.

Check conductor sizing, terminal compatibility, phase arrangement, tightening torque, and thermal conditions. Incorrect connections can cause excessive resistance, overheating, and equipment damage.

6. Configure Protection Settings

Protection settings must be coordinated with the electrical installation.

Review long-time, short-time, instantaneous, and ground-fault settings where these functions are available. Do not copy settings from another breaker without checking the system design and the exact trip-unit configuration.

7. Perform Commissioning Checks

Before energizing the system, qualified personnel should inspect mechanical operation, electrical connections, insulation condition, grounding, and auxiliary wiring.

Functional testing should follow the manufacturer’s procedures. Record the installed catalog number, trip-unit model, protection settings, and commissioning results for future maintenance.

Compatible System Components

The NS1250H is normally installed as part of a larger low-voltage distribution system.

Component Function Integration Considerations
Main distribution board Receives and distributes electrical power Confirm busbar rating and available installation space
Copper or aluminum busbars Carry high-current electrical power Verify current capacity, connection geometry, and thermal limits
MicroLogic trip unit Provides electronic protection functions Confirm exact model and protection capabilities
Auxiliary contacts Provide breaker position or status signals Check accessory compatibility and wiring
Shunt trip accessory Enables remote electrical tripping Verify operating voltage and accessory reference
Undervoltage release Trips or prevents operation under specified voltage conditions Confirm coil rating and control-circuit design
Motor mechanism Supports electrical opening and closing where equipped Check compatibility with the exact breaker version
Current transformers or metering devices Support electrical measurement and monitoring Verify measurement arrangement and system requirements
Downstream circuit breakers Protect individual feeders and loads Coordinate trip characteristics and selectivity
Power monitoring system Collects electrical and breaker status information Requires compatible communication accessories where applicable

The table describes components that may be used in an NS1250H installation. They are not necessarily included with every breaker.

Alternative Models and Replacement Considerations

The NS1250H belongs to a high-capacity circuit breaker family. Replacement selection must be based on electrical and mechanical compatibility rather than rated current alone.

Alternative or Related Product Replacement Considerations
Schneider ComPact NS630b–1600 models Related product family; verify current rating, breaking capacity, and frame configuration
Schneider ComPact NS1250H with matching trip unit Preferred starting point for like-for-like replacement when the complete configuration matches
Schneider ComPact NS1250N or other breaking-capacity variants Check short-circuit performance carefully; breaking capacity may differ
Schneider ComPact NS1600 models Higher current frame option, but not automatically a direct replacement
Schneider MasterPact series May be considered for switchboard redesign or system upgrades; dimensional and functional changes may be required
Other manufacturers’ 1250 A breakers Require detailed electrical, mechanical, and protection coordination checks

Before selecting an alternative, compare:

  • Rated operational voltage.
  • Rated current and temperature conditions.
  • Ultimate and service short-circuit breaking capacity.
  • Pole configuration.
  • Trip-unit type and protection functions.
  • Fixed or withdrawable mounting arrangement.
  • Manual or electrical operating mechanism.
  • Busbar and terminal connection dimensions.
  • Auxiliary contact and release accessories.
  • Panel cutout and installation clearances.

A breaker with the same 1250 A rating may not be suitable if its interrupting capacity, trip characteristics, or mechanical arrangement differs from the original device.

Key Advantages

High Current Capacity

The 1250 A rated-current specification makes the NS1250H suitable for appropriately designed high-capacity distribution circuits.

High Short-Circuit Breaking Capacity

The H breaking-capacity class provides a published 70 kA ultimate breaking capacity at 380/415 V AC, supporting use in suitable installations with high prospective fault currents.

Electronic Protection Options

Compatible MicroLogic trip units provide electronic protection functions and configurable settings. The exact available functions depend on the selected version.

Flexible Configuration

The ComPact NS1250H family offers different pole arrangements, operating mechanisms, and mounting options, allowing engineers to select a configuration that matches the switchboard design.

Industrial Power Distribution Application

The breaker is designed for demanding power distribution environments, including industrial switchboards, main distribution boards, and large feeder circuits.

Isolation Capability

Compatible configurations provide circuit isolation in accordance with applicable IEC 60947-2 requirements.

Integration with Distribution Accessories

Depending on the exact model, compatible auxiliary contacts, releases, operating mechanisms, and monitoring accessories can support broader electrical control and monitoring requirements.

Technical FAQs

1. What is the Schneider NS1250H?

The Schneider NS1250H is a ComPact NS series high-capacity circuit breaker designed for industrial and commercial power distribution. It has a rated current of 1250 A.

2. What is the rated voltage of the NS1250H?

The published rated operational voltage is up to 690 V AC at 50/60 Hz. The applicable breaking capacity depends on the operating voltage.

3. What is the breaking capacity of the NS1250H?

The H breaking-capacity class provides a rated ultimate short-circuit breaking capacity of 70 kA at 380/415 V AC. The rating is lower at some higher operating voltages.

4. Is the NS1250H available in both 3-pole and 4-pole versions?

Yes. The product family includes 3-pole and 4-pole configurations. The exact pole arrangement should be checked from the complete catalog number and nameplate.

5. Does the NS1250H use a MicroLogic trip unit?

MicroLogic trip units are available in NS1250H configurations. The exact trip unit depends on the selected breaker reference and should be confirmed before purchase.

6. What protection functions can be provided?

Depending on the installed trip unit, protection may include long-time, short-time, instantaneous, and other functions. The available protection features must be confirmed from the trip-unit model.

7. Can the NS1250H be used as a main circuit breaker?

It can be considered for main distribution applications where its rated current, voltage, breaking capacity, and protection characteristics meet the electrical system requirements.

8. Is the NS1250H suitable for a 415 V AC system?

The H-class version has a published 70 kA ultimate breaking capacity at 380/415 V AC. Suitability still depends on the actual prospective fault current, system design, and protection coordination.

9. What should be checked before replacing an existing NS1250H?

Check the complete catalog number, pole configuration, trip unit, mounting method, operating mechanism, accessory references, terminal arrangement, and protection settings. Mechanical fit alone is not sufficient.

10. What is the difference between a fixed and withdrawable NS1250H?

A fixed breaker is installed directly in its mounting position. A withdrawable version uses a compatible cradle or chassis arrangement, allowing the breaker to be moved between operating, test, and disconnected positions according to its design. The two arrangements are not automatically interchangeable.

Procurement and Maintenance Recommendations

When purchasing a Schneider NS1250H, verify the exact configuration rather than relying on the family designation alone.

The most important details are the complete catalog number, rated current, pole count, MicroLogic trip-unit model, mounting arrangement, and operating mechanism. These details determine whether the breaker can be installed in the existing switchboard and provide the required protection functions.

For used or refurbished equipment, request clear photographs of the nameplate, front panel, terminals, and operating mechanism. Confirm whether the trip unit and accessories are included. Ask for available inspection or functional-test information, especially when the breaker is intended for a critical power distribution circuit.

During maintenance, inspect the main contacts, connection points, operating mechanism, insulation components, and auxiliary circuits according to the manufacturer’s maintenance procedures. Check for discoloration, overheating, mechanical damage, contamination, and loose connections.

Protection settings should be documented and reviewed whenever the distribution system changes. Periodic testing should be performed by qualified personnel using appropriate procedures and equipment.

For replacement projects, compare the existing switchboard dimensions, busbar arrangement, cable connections, and required clearances with the proposed breaker. A replacement with the same rated current may still require mechanical modifications or changes to the protection coordination.

Conclusion

The Schneider Electric NS1250H ComPact NS Circuit Breaker is a high-capacity protection device designed for industrial and commercial power distribution systems. With a rated current of 1250 A and an H-class ultimate breaking capacity of 70 kA at 380/415 V AC, it is intended for installations requiring substantial current capacity and high short-circuit interruption performance.

The product family offers different pole configurations, trip units, operating mechanisms, and mounting arrangements. Accurate identification of the complete catalog number is therefore essential when purchasing or replacing the breaker.

For maintenance and procurement applications, checking the electrical ratings, trip-unit configuration, mounting dimensions, and accessory requirements helps ensure that the NS1250H is suitable for the intended distribution system.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501