Product Overview The Foxboro RH916FM I/A Series 200 Type 4 P/PVC Termination Cable is an industrial control-system cable associated with Foxboro I/A Series 200 equipment. It serves as a physical electri……
Foxboro RH916FM I/A Series 200 Type 4 P/PVC Termination Cable
  • Foxboro
  • RH916FM
  • Termination Cable
  • USA
  • 15 meters
  • 3 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 9

Our advantage

Foxboro RH916FM I/A Series 200 Type 4 P/PVC Termination Cable

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Foxboro RH916FM I/A Series 200 Type 4 P/PVC Termination Cable

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Foxboro RH916FM I/A Series 200 Type 4 P/PVC Termination Cable

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Foxboro RH916FM I/A Series 200 Type 4 P/PVC Termination Cable

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Foxboro RH916FM I/A Series 200 Type 4 P/PVC Termination Cable is an industrial control-system cable associated with Foxboro I/A Series 200 equipment. It serves as a physical electrical connection between designated system interfaces, supporting the wiring arrangements used in process automation installations.

In distributed control systems, termination cables connect compatible control hardware and termination points according to the system’s wiring configuration. Selecting the correct cable helps maintain signal continuity and reduces the risk of wiring errors during commissioning, equipment replacement, and routine maintenance. An incorrect connection arrangement can lead to missing signals, intermittent faults, or additional troubleshooting during system startup.

The RH916FM is identified as a Type 4 P/PVC termination cable. Its application depends on the interfaces and termination scheme used in the installed system. Before replacing an existing cable, engineers should verify the model designation, connector arrangement, and intended connection points against the system’s wiring documentation.


Technical Specifications

Parameter Specification
Brand Foxboro
Model RH916FM
Product Series I/A Series 200
Product Type Type 4 P/PVC Termination Cable
Component Category Industrial Control-System Cable
Cable Construction Designation P/PVC
Cable Type Type 4
Primary Function Electrical Connection and Signal Transmission
Application Industrial Process Control Systems
System Compatibility Applicable Foxboro I/A Series 200 Configurations
Installation Context Control-System Wiring and Termination
Connection Requirements Must Match the Intended Equipment Interfaces
Cable Length 15 meters
Shipping Weight 3 kg

Product Features

  • I/A Series 200 integration: Intended for applicable Foxboro control-system wiring arrangements where this cable configuration is specified.
  • Termination cable configuration: Establishes an electrical connection between designated interfaces within a control-system installation.
  • Type 4 designation: Identifies the cable configuration specified for the intended application.
  • P/PVC construction designation: Retains the stated cable construction designation for product identification and selection.
  • Industrial control wiring: Supports interconnection requirements in process automation systems.
  • Maintenance and replacement use: Can be considered when replacing a matching cable after the connection details have been verified.
  • Signal path continuity: Helps maintain the intended electrical path between compatible control-system components.
  • Cable identification: The model designation supports inventory management, maintenance planning, and replacement work.

Working Principle

The RH916FM functions as a physical electrical connection between designated points in a control system. Its conductors carry the electrical signals required by the connected equipment, while the termination arrangement establishes the intended connections between interfaces.

In a process-control installation, the cable forms part of the wiring path between compatible control hardware and a designated termination point. The connected equipment determines the signal type and processing behavior; the cable provides the electrical path through which those signals travel.

Signal continuity depends on the condition of the conductors, insulation, connectors, and termination points. Loose connections, damaged cable sections, incorrect pin assignments, or an unsuitable replacement can interrupt the signal path and lead to faults elsewhere in the control system.

A simplified connection path is:

Foxboro Control-System Equipment → RH916FM Termination Cable → Designated Termination Interface → Connected Control-System Hardware

The actual connection points and signal assignments depend on the installed equipment and its wiring configuration.


Role in an I/A Series 200 Control Architecture

Within an I/A Series 200 control architecture, the RH916FM provides the physical cable connection required by the applicable system wiring arrangement. It supports the electrical interconnection of compatible components so that designated signals can pass between the relevant interfaces.

Control-System Component Function Relationship to the RH916FM
I/A Series 200 Control Hardware Executes control and process-related functions Connects through the applicable wiring interface
Termination Assembly Organizes electrical connections between system components Provides a designated termination point where applicable
RH916FM Termination Cable Carries electrical signals between specified connection points Establishes the physical connection required by the wiring arrangement
I/O Interface Exchanges signals between the control system and connected equipment May connect through the relevant termination arrangement
Field Instrumentation Measures process conditions or provides control signals Participates in the signal path when included in the configured system
Control Cabinet Houses control hardware and wiring assemblies Provides the installation environment for the cable and connected components
System Wiring Documentation Defines connection points and signal assignments Supports correct cable installation and troubleshooting

The cable’s position in the architecture depends on the specific hardware configuration. During installation or replacement, preserving the intended connection arrangement and verifying the termination points helps prevent wiring errors and unnecessary commissioning work.


Industrial Applications

Application Typical Requirement Role of the RH916FM
Process Automation Electrical connections between control-system components Provides the specified cable connection within the control architecture
Chemical Processing Organized wiring for distributed process-control equipment Supports the required connection between designated interfaces
Oil and Gas Facilities Control-system wiring in process equipment installations Can be used where the applicable termination configuration calls for this cable
Power Generation Electrical signal connections within control-system cabinets Supports the designated wiring path
Water and Wastewater Treatment Connections between process-control hardware and related interfaces Provides the physical cable connection where specified
Industrial Control Cabinets Internal interconnection of control-system components Maintains the intended wiring arrangement
Control-System Maintenance Replacement of a damaged or worn cable Supports replacement when the model and connection requirements match
Existing I/A Series Installations Continued operation of established control-system configurations Supports maintenance of the original cabling arrangement

Installation and Maintenance

  1. Confirm the cable model. Verify that RH916FM matches the cable designation required by the existing control-system installation.
  2. Identify the connection points. Determine the intended source and destination interfaces before disconnecting or installing the cable.
  3. Review the wiring arrangement. Check the applicable wiring diagram, connector assignments, and termination layout to avoid incorrect connections.
  4. Apply electrical safety procedures. Follow site isolation procedures before handling control-system wiring.
  5. Inspect the cable before installation. Check the outer jacket, connectors, and accessible termination points for damage or contamination.
  6. Verify connector compatibility. Ensure that the cable ends match the designated equipment interfaces and can be secured correctly.
  7. Route the cable appropriately. Avoid sharp edges, excessive bending, crushing, and unnecessary mechanical tension.
  8. Separate wiring where required. Maintain suitable separation from power conductors and potential interference sources according to the installation requirements.
  9. Secure the terminations. Confirm that connectors or terminal connections are fully seated and secured according to the applicable hardware arrangement.
  10. Check continuity when necessary. If installing a replacement or investigating a suspected cable fault, perform suitable continuity and wiring checks with the circuit safely isolated.
  11. Test the connected system. Verify that the relevant signals and system functions operate as expected after installation.
  12. Record the maintenance work. Document the cable replacement, connection points, inspection results, and any changes to the wiring arrangement.

If a signal fault occurs after installation, check cable seating, connector condition, conductor continuity, and termination assignments. Confirm that the replacement matches the required configuration before investigating other control-system components.


Related Components

Component Function Relationship to the RH916FM
Foxboro I/A Series 200 Control Hardware Performs control-system functions Provides the applicable equipment interface
Foxboro Termination Assembly Organizes system wiring and electrical connections May serve as the cable’s designated termination point
Foxboro I/O Module Handles input or output signals within the control system Connects through the relevant system wiring arrangement
Control-System Connector Establishes the electrical connection between cable and equipment Must match the cable’s connector configuration
Industrial Control Cabinet Houses control hardware and wiring Provides the physical installation environment
Field Signal Wiring Carries signals between instruments and control interfaces Forms part of the wider signal path where applicable
Cable Identification Labels Identify wiring and connection destinations Help prevent incorrect reconnection during maintenance
Wiring Documentation Defines connection assignments and routing Supports installation, testing, and fault diagnosis

Recommended Related Models

Model Product Name Typical Application
P0916FM Foxboro I/A Series 200 Type 4 P/PVC Termination Cable Related termination cable model
P0916FL Foxboro I/A Series 200 Type 4 P/PVC Termination Cable Related termination cable model
RH916FL Foxboro I/A Series 200 Type 4 P/PVC Termination Cable Related Type 4 termination cable
RH916FK Foxboro I/A Series 200 Type 4 P/PVC Termination Cable Related Type 4 termination cable
FBM203d Foxboro I/A Series Fieldbus Module Industrial process-control signal interfacing
FBM204 Foxboro I/A Series Fieldbus Module Control-system I/O applications, subject to configuration
FBM205 Foxboro I/A Series Fieldbus Module Control-system I/O applications, subject to configuration

Key Advantages

  • Supports the specified electrical connection within an I/A Series 200 installation.
  • Maintains the intended wiring path between designated system interfaces.
  • Supports cable replacement and maintenance when the connection configuration matches.
  • Helps maintain organized control-cabinet wiring.
  • Supports signal continuity across the intended electrical connection.
  • Fits established industrial process-control wiring arrangements when correctly matched.

Technical FAQs

1. What is the Foxboro RH916FM used for?

The RH916FM is identified as an I/A Series 200 Type 4 P/PVC termination cable. It provides the specified electrical connection between compatible control-system interfaces within the applicable wiring arrangement.

2. What should be checked before replacing an RH916FM cable?

Verify the exact model designation, connector configuration, connection points, and wiring assignments. A cable with a similar appearance may have a different termination arrangement or electrical application.

3. How can cable-related signal faults be diagnosed?

Inspect the cable and connectors, verify that the terminations are secure, and perform appropriate continuity checks with the circuit safely isolated. If the cable passes these checks, investigate the connected interfaces and the wider signal path.

4. Can the RH916FM replace the P0916FM or RH916FL termination cable?

Direct interchangeability should not be assumed from similar product descriptions alone. Confirm the connector arrangement, wiring assignments, and intended application of each cable before selecting a replacement.