• Allen Bradley 80026-420-62-R Powerware 9130 Battery Assembly
  • Allen Bradley 80026-420-62-R Powerware 9130 Battery Assembly
  • Allen Bradley 80026-420-62-R Powerware 9130 Battery Assembly
  • Allen Bradley 80026-420-62-R Powerware 9130 Battery Assembly
Product Overview The Allen Bradley 80026-420-62-R Powerware 9130 Battery Assembly is a replacement battery assembly associated with the Powerware 9130 uninterruptible power supply (UPS) system. It belon……
Allen Bradley 80026-420-62-R Powerware 9130 Battery Assembly
  • Allen Bradley
  • 80026-420-62-R
  • Battery Assembly
  • USA
  • 438 x 86 x 438 mm
  • 12 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 28

Our advantage

Allen Bradley 80026-420-62-R Powerware 9130 Battery Assembly

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Allen Bradley 80026-420-62-R Powerware 9130 Battery Assembly

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Allen Bradley 80026-420-62-R Powerware 9130 Battery Assembly

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Allen Bradley 80026-420-62-R Powerware 9130 Battery Assembly

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Allen Bradley 80026-420-62-R Powerware 9130 Battery Assembly is a replacement battery assembly associated with the Powerware 9130 uninterruptible power supply (UPS) system. It belongs to the backup-power section of the UPS architecture and supports continued operation of connected equipment when the normal AC power source is interrupted.

Unlike an AC/DC power supply, the battery assembly does not primarily perform AC-to-DC conversion for the control cabinet. Its function is energy storage and backup power support. During normal operation, the UPS maintains the battery system in a charged condition. When an input-power interruption occurs, stored energy becomes available to the UPS inverter so that connected loads can continue receiving power for the available backup period.

For maintenance engineers, the 80026-420-62-R is particularly relevant when servicing an existing Powerware 9130 installation and restoring the battery portion of the UPS system.


Technical Specifications

Parameter Specification
Manufacturer Allen Bradley
Model 80026-420-62-R
Product Family Powerware 9130
Product Type Battery Assembly
Application UPS Backup Power
Dimensions 438 x 86 x 438 mm
Weight 12 kg

Product Features

The 80026-420-62-R is intended for battery backup applications within the Powerware 9130 UPS platform.

Key characteristics include:

  • Allen Bradley Powerware 9130 battery assembly
  • Model 80026-420-62-R
  • Used as part of a UPS backup-power system
  • Provides stored electrical energy for backup operation
  • Suitable for Powerware 9130 maintenance applications
  • Supports continued UPS operation during utility-power interruptions
  • Intended for replacement and servicing of the battery section
  • Works together with the UPS charging and inverter circuits
  • Requires correct installation within the applicable UPS configuration

Battery assemblies should be treated as system-specific service components. Before replacement, the UPS model, battery configuration, connectors, and installation arrangement should be verified.


Working Principle

The 80026-420-62-R operates as the stored-energy section of the Powerware 9130 UPS.

A simplified UPS power path can be represented as:

AC Utility Power → UPS Charger / Power Circuit → Battery Assembly → UPS Inverter → Protected Load

During normal operation, the UPS charging circuit maintains the battery assembly at the required state of charge. The stored electrical energy remains available for use if the incoming utility supply is interrupted.

When an input-power failure occurs, the UPS transfers its energy source to the battery system. The stored DC energy is then used by the UPS inverter to maintain power to the protected load.

This makes the battery assembly different from a conventional industrial power supply. It does not act as the primary power-conversion device for the automation cabinet; instead, it serves as the stored-energy source that allows the UPS to maintain power continuity.


Role in a UPS System

The 80026-420-62-R occupies the energy-storage layer of the Powerware 9130 UPS architecture.

A simplified arrangement is:

Utility Power → UPS → Battery Assembly → Inverter → Protected Equipment

The battery assembly works together with the UPS charging system, inverter, control electronics, and protected-load connections.

In an industrial environment, the UPS may support equipment such as:

  • PLC controllers
  • Industrial computers
  • HMI systems
  • Communication equipment
  • Network devices
  • Instrumentation
  • Control-system interfaces
  • Other critical electronic loads

Maintaining the battery section in suitable condition is therefore important when the UPS is used to protect equipment that cannot tolerate an unexpected power interruption.


Industrial Applications

The 80026-420-62-R is applicable to installations using the Powerware 9130 UPS platform.

Application Typical Use
Industrial Automation Backup power for control equipment
PLC Systems Maintaining controller operation during outages
HMI Systems Supporting operator-interface continuity
Industrial Networking Backup power for communication equipment
Process Control Protecting critical control electronics
Manufacturing Equipment Supporting controlled shutdown or continued operation
Data and Control Cabinets UPS battery backup
Plant Maintenance Replacement of depleted battery assemblies

The actual backup duration depends on the UPS configuration, battery condition, and connected load.


Installation and Maintenance

Battery replacement should be performed according to the UPS maintenance procedure and with attention to the electrical hazards associated with stored energy.

Before servicing the 80026-420-62-R, technicians should identify the UPS model and confirm that the replacement battery assembly matches the installed configuration.

Recommended checks include:

  • Confirm the complete 80026-420-62-R model number.
  • Verify the Powerware 9130 UPS configuration.
  • Follow the applicable shutdown and isolation procedure.
  • Inspect battery connectors and wiring.
  • Check for damaged cables or terminals.
  • Inspect the battery compartment before installation.
  • Install the replacement assembly in the correct position.
  • Ensure electrical connections are secure.
  • Verify UPS battery status after installation.
  • Allow the charging system to complete its required charging process.
  • Perform an appropriate UPS battery test.
  • Monitor the UPS for battery-related alarms.

Battery assemblies should not be treated as ordinary electronic modules. Appropriate safety procedures are required because the stored electrical energy can remain hazardous even when the normal AC supply has been disconnected.


Related Components

The 80026-420-62-R forms part of a larger Powerware 9130 UPS architecture.

Component Function
Powerware 9130 UPS Provides uninterruptible power
Battery Assembly Stores backup electrical energy
Battery Charger Maintains battery charge
UPS Inverter Converts stored DC energy for the protected load
UPS Control Electronics Manages UPS operating functions
Input Power Circuit Provides utility power
Output Power Circuit Supplies protected equipment
Protected Load Receives backup power from the UPS

The battery assembly should be evaluated together with the UPS charging and inverter sections when diagnosing backup-power problems.


Recommended Related Models

Model / Product Family Product Type Typical Application
Allen Bradley 80026-420-62-R Powerware 9130 Battery Assembly UPS battery replacement
Allen Bradley 80026-172-23 AC/DC Power Supply Industrial control-system power
Allen Bradley 80026-096-01 DC/DC Converter Power Supply DC power conversion
Allen Bradley 80026-088-01 AC/DC Switching Power Supply AC/DC power conversion
Allen Bradley Powerware 9130 UPS System Uninterruptible power protection
Allen Bradley 1606 Series Industrial Power Supply Automation control power

The 80026-420-62-R is specifically a battery assembly, so it should not be substituted with a conventional power supply simply because both products are associated with electrical power systems.


Key Advantages

  • Powerware 9130 battery assembly
  • Provides stored energy for UPS backup operation
  • Supports continuity of protected electrical loads
  • Suitable for Powerware 9130 maintenance
  • Useful for battery replacement applications
  • Works with the UPS charging and inverter architecture
  • Supports critical automation and electronic equipment
  • Helps maintain the backup-power capability of an established UPS installation

Technical FAQs

What is the Allen Bradley 80026-420-62-R used for?

The 80026-420-62-R is a Powerware 9130 Battery Assembly used as the stored-energy source within the UPS system.

What happens when utility power is interrupted?

When the normal input supply is interrupted, the UPS uses stored energy from the battery assembly to maintain power to the protected load through the UPS inverter.

When should the battery assembly be investigated during UPS maintenance?

It should be investigated when the UPS reports battery-related alarms, reduced backup performance, charging problems, or an inability to maintain the expected load during a power interruption.

What should be checked before replacing the 80026-420-62-R?

The Powerware 9130 configuration, complete battery assembly model, connectors, wiring, installation position, and applicable UPS maintenance procedure should be verified before replacement.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501