• Allen Bradley 20G1AJC770AN0NNNNN PowerFlex AC Drive
  • Allen Bradley 20G1AJC770AN0NNNNN PowerFlex AC Drive
  • Allen Bradley 20G1AJC770AN0NNNNN PowerFlex AC Drive
  • Allen Bradley 20G1AJC770AN0NNNNN PowerFlex AC Drive
Allen-Bradley 20G1AJC770AN0NNNNN PowerFlex 755 AC Drive 1. Product Overview The Allen-Bradley 20G1AJC770AN0NNNNN is a high-power PowerFlex 755 air-cooled AC drive designed for large industrial motor-con……
Allen Bradley 20G1AJC770AN0NNNNN PowerFlex AC Drive
  • Allen Bradley
  • 20G1AJC770AN0NNNNN
  • PowerFlex AC Drive
  • USA
  • 2102 × 606 × 600 mm
  • 650kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 45

Our advantage

Allen Bradley 20G1AJC770AN0NNNNN PowerFlex AC Drive

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Allen Bradley 20G1AJC770AN0NNNNN PowerFlex AC Drive

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Allen Bradley 20G1AJC770AN0NNNNN PowerFlex AC Drive

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Allen Bradley 20G1AJC770AN0NNNNN PowerFlex AC Drive

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Allen-Bradley 20G1AJC770AN0NNNNN PowerFlex 755 AC Drive

1. Product Overview

The Allen-Bradley 20G1AJC770AN0NNNNN is a high-power PowerFlex 755 air-cooled AC drive designed for large industrial motor-control applications.

It belongs to the PowerFlex 755 series and is configured for a 400 VAC, three-phase electrical system. The drive provides a nominal continuous output current of 770 A, with application ratings of 450 kW Light Duty, 400 kW Normal Duty, and 355 kW Heavy Duty. It uses a large Frame 8 construction and an 800 mm deep MCC-style enclosure with Type 12 / IP54 protection.

The 20G1AJC770AN0NNNNN is intended for installations where a conventional compact inverter is not sufficient because of motor size, output current, mechanical load, process requirements, or the need for a large integrated industrial drive system.

It is particularly well suited to large pumps, fans, blowers, conveyors, water and wastewater equipment, mining machinery, process equipment, material-handling systems, industrial HVAC, and other large rotating machines.

The model incorporates embedded EtherNet/IP, allowing the drive to participate in a modern industrial automation architecture. The drive is also configured with an EMC filter, while the catalog configuration specifies the common-mode capacitor jumper as removed. It uses AC input with precharge and no DC input terminals, and the standard configuration has no dynamic braking.

An important catalog-status point should also be noted: 20G1AJC770AN0NNNNN is a discontinued configuration. The listed direct replacement is 20G1AJC770JN0NNNNN. The major distinction between the AN0 and JN0 configurations is the filtering/common-mode jumper configuration, so replacement engineering should not be performed solely by matching the output current.

2. Brand and Product Series

Item Specification
Brand Allen-Bradley
Product Family PowerFlex
Product Series PowerFlex 755
Product Type High-Power Air-Cooled AC Drive
Catalog Number 20G1AJC770AN0NNNNN
Drive Category Variable Frequency AC Drive
Construction Floor-Standing / MCC Style
Frame Frame 8
Cooling Forced Air
Input Voltage Class 400 VAC
Input Phase 3 Phase
Output Current 770 A
Enclosure Type 12
Ingress Protection IP54
MCC Style Depth 800 mm
Communications Embedded EtherNet/IP
Dynamic Braking None
Input Configuration AC Input with Precharge
DC Input Terminals None
EMC Filtering Filtered
CM Jumper Removed
HIM Blank / No HIM
Lifecycle Discontinued
Direct Replacement 20G1AJC770JN0NNNNN

The PowerFlex 755 series is positioned toward larger industrial motor applications where higher current capacity, advanced control, communications, diagnostics, and integration into plant automation systems are required.

Within the 400 VAC class, the 770 A configuration is one of the largest Frame 8 options before moving into higher-current Frame 9 and larger configurations. The published selection data identify the 770 A model as a Frame 8 drive with 450 kW Light Duty, 400 kW Normal Duty, and 355 kW Heavy Duty capability.

3. Detailed Technical Specifications

Parameter Specification
Model / Catalog Number 20G1AJC770AN0NNNNN
Brand Allen-Bradley
Series PowerFlex 755
Product Type Air-Cooled AC Drive
Input Voltage 380–400 VAC class / 400 VAC nominal
Input Phase Three Phase
Rated Output Current 770 A
Light-Duty Power 450 kW
Normal-Duty Power 400 kW
Heavy-Duty Power 355 kW
Light-Duty Continuous Current 770 A
Light-Duty 1-Minute Current 847 A
Light-Duty 3-Second Current 1,155 A
Normal-Duty Continuous Current 642 A
Normal-Duty 1-Minute Current 963 A
Normal-Duty 3-Second Current 1,155 A
Heavy-Duty Continuous Current 585 A
Heavy-Duty 1-Minute Current 878 A
Heavy-Duty 3-Second Current 1,125 A
Frame Size Frame 8
Cooling Forced Air
Enclosure Type 12
Protection IP54
MCC Style 800 mm Deep
Input Type AC Input with Precharge
DC Terminals None
EMC Filter Yes
Common-Mode Jumper Removed
Dynamic Braking None
Communications Embedded EtherNet/IP
HIM Blank / No HIM
Installation Style Floor-Standing / MCC Style
Approx. Width Approximately 600 mm class*
Approx. Height Approximately 2,000–2,200 mm class*
Approx. Depth Approximately 800 mm*
Approx. Weight Approximately 500–700 kg*

The published electrical selection data show 832 A Light-Duty one-minute current and 915 A three-second current, 770 A continuous Light-Duty current, 642 A continuous Normal-Duty current, and 585 A continuous Heavy-Duty current. The corresponding power ratings are 450 kW, 400 kW, and 355 kW respectively.

*The 800 mm depth is associated with the MCC-style configuration. Width, height, and complete assembled/shipping weight should be treated as preliminary planning values, not certified mechanical dimensions. For final equipment-room layout, lifting arrangements, floor loading, transportation, and cabinet installation, the exact mechanical drawing for the configured unit should be used.

4. Electrical Performance

4.1 400 VAC Three-Phase Input

The 20G1AJC770AN0NNNNN is designed for the 380–400 VAC / 400 VAC class, three-phase industrial power system.

This voltage class is widely used for large industrial motors and process equipment.

The three-phase configuration is appropriate for high-power AC motors because it provides the electrical structure required for large motor loads while allowing the drive to regulate motor speed and torque electronically.

4.2 770 A Output Capacity

The most distinctive characteristic of this model is its 770 A output-current class.

A 770 A drive belongs to the high-power end of conventional low-voltage AC motor drives.

This makes it suitable for motors and machines that would be beyond the practical range of smaller Frame 6 or Frame 7 drives.

The high current rating is particularly useful for applications involving:

  • Large process pumps.
  • Large ventilation fans.
  • High-capacity blowers.
  • Long conveyors.
  • Mining machinery.
  • Material-handling systems.
  • Industrial process machinery.
  • Large utility equipment.
  • High-capacity water systems.
  • Heavy industrial rotating equipment.

5. Duty Ratings

One of the most important aspects of this model is the distinction between Light Duty, Normal Duty, and Heavy Duty.

Duty Type Continuous Current 1-Minute Current 3-Second Current Power Rating
Light Duty 770 A 847 A 1,155 A 450 kW
Normal Duty 642 A 963 A 1,155 A 400 kW
Heavy Duty 585 A 878 A 1,125 A 355 kW

These ratings show why selecting a drive solely according to the motor’s nameplate kW can be misleading.

A 400 kW motor, for example, may be an appropriate Normal-Duty application, but the same drive should not automatically be assumed to provide the same rating for a demanding Heavy-Duty application.

Heavy-duty machinery can require greater current during acceleration and operation.

Examples include:

  • High-inertia conveyors.
  • Crushers.
  • Mixers.
  • Heavy material-handling machines.
  • Machines with frequent acceleration.
  • Machines with substantial torque requirements.
  • Equipment with demanding overload cycles.

Therefore, the actual motor current, torque requirement, acceleration profile, load inertia, and duty cycle should all be evaluated during drive selection.

6. Frame 8 Construction

The 20G1AJC770AN0NNNNN uses Frame 8 construction.

This is a large industrial drive frame.

Frame 8 is not intended to be treated like a small wall-mounted inverter.

The equipment should normally be considered part of a floor-standing electrical installation.

The large frame provides the physical space necessary for high-current power components, cooling equipment, electrical connections, protection equipment, and associated control hardware.

The Frame 8 construction also has implications for:

  • Transportation.
  • Lifting.
  • Floor loading.
  • Cabinet access.
  • Cable routing.
  • Ventilation.
  • Maintenance clearance.
  • Service access.
  • Installation labor.
  • Electrical-room planning.

7. 800 mm Deep MCC-Style Construction

The drive uses an 800 mm deep MCC-style configuration.

This is particularly useful for large industrial electrical installations where the drive is integrated into a larger motor-control arrangement.

The 800 mm depth should be considered when designing:

  • Electrical rooms.
  • MCC lineups.
  • Drive cabinets.
  • Cable trenches.
  • Rear service areas.
  • Front maintenance areas.
  • Equipment transportation routes.
  • Door and access clearances.

The depth is not simply a catalog dimension.

For a large 770 A drive, adequate space is required for power cables, ventilation, maintenance access, equipment handling, and safe working conditions.

8. Approximate Dimensions and Weight

Physical dimensions and weight are particularly important for this model because it is a large Frame 8 packaged drive.

Mechanical Parameter Approximate Value / Planning Reference
Model 20G1AJC770AN0NNNNN
Frame Frame 8
Enclosure Type 12 / IP54
MCC Depth 800 mm
Approx. Width ~600 mm class
Approx. Height ~2,000–2,200 mm
Approx. Depth ~800 mm
Approx. Complete Weight ~500–700 kg
Installation Floor Standing
Cooling Forced Air
Handling Heavy Equipment Handling
Service Requirement Adequate front/service clearance

The 800 mm depth is the strongest published mechanical reference for this configuration.

The width and height above are practical planning ranges for a large Frame 8 MCC-style package, while the 500–700 kg weight range should be regarded as a preliminary equipment-planning estimate.

The final shipping weight can vary according to the exact cabinet arrangement, internal equipment, options, accessories, and packaging.

For a project involving lifting equipment, floor reinforcement, transportation, seismic calculations, or structural loading, the final configured mechanical documentation should take precedence.

9. Cooling System

The 20G1AJC770AN0NNNNN is an air-cooled drive using forced-air cooling.

At 770 A, thermal management is a major engineering consideration.

The drive converts electrical power to motor power while inevitably generating heat within its power electronics.

The cooling system is therefore an integral part of reliable operation.

The installation should provide appropriate:

  • Airflow.
  • Ventilation.
  • Cabinet clearance.
  • Ambient temperature control.
  • Air inlet conditions.
  • Exhaust-air management.
  • Fan maintenance.

Potential cooling problems can arise from:

  • Blocked ventilation openings.
  • Excessive dust.
  • High ambient temperature.
  • Fan degradation.
  • Incorrect cabinet arrangement.
  • Hot-air recirculation.
  • Poor electrical-room ventilation.

For large industrial installations, the heat generated by multiple drives should be considered when designing the overall electrical room.

10. Enclosure and Protection

The 20G1AJC770AN0NNNNN is configured as Type 12 / IP54.

This provides a substantially more protected installation format than an open-frame drive.

The enclosure is suitable for many industrial electrical-room environments where protection from dust and general industrial contamination is important.

However, Type 12 / IP54 protection should not be interpreted as making the drive suitable for every outdoor or washdown environment.

Application-specific environmental conditions should always be reviewed, including:

  • Humidity.
  • Condensation.
  • Chemical vapors.
  • Salt atmosphere.
  • Conductive dust.
  • High ambient temperature.
  • Outdoor exposure.
  • Washdown conditions.
  • Altitude.
  • Corrosive atmospheres.

11. Embedded EtherNet/IP

The drive includes embedded EtherNet/IP.

This is an important feature for industrial automation applications.

A large motor drive frequently needs to exchange information with a PLC, HMI, supervisory control system, process controller, or plant network.

Using embedded EtherNet/IP allows the drive to become an integrated part of the control architecture.

Typical information exchanged can include:

  • Start and stop commands.
  • Speed reference.
  • Drive status.
  • Motor speed.
  • Output frequency.
  • Motor current.
  • Fault information.
  • Alarm information.
  • Operating conditions.
  • Diagnostic information.
  • Parameter-related data.

For large installations containing many drives, network communications can substantially reduce the amount of conventional hardwired control wiring.

12. EMC Filter Configuration

The catalog configuration specifies an EMC filter.

The filter is relevant in industrial environments where electromagnetic compatibility must be considered.

AC drives use high-frequency switching techniques to generate the required motor voltage waveform.

This switching behavior is essential to drive operation but can also introduce electrical noise.

A properly configured filtering and grounding system can help manage conducted and radiated electrical interference.

However, the filter alone is not a complete EMC solution.

The complete installation should also consider:

  • Motor cable construction.
  • Cable shielding.
  • Grounding.
  • Cable routing.
  • Control-cable separation.
  • Cabinet bonding.
  • Motor grounding.
  • Network-cable routing.
  • Installation practices.

13. Common-Mode Jumper Configuration

The AN0 configuration indicates that the common-mode capacitor jumper is removed.

This is an important catalog-level distinction.

The related JN0 replacement configuration uses the installed jumper arrangement.

Therefore, when replacing an AN0 drive with a JN0 drive, the engineering team should not simply exchange the units without reviewing the applicable installation and grounding requirements.

The electrical system, motor insulation, grounding arrangement, EMC requirements, and drive configuration should be checked as part of the replacement process.

14. Dynamic Braking

The 20G1AJC770AN0NNNNN is specified with no dynamic braking.

This is an important consideration for machines that must decelerate rapidly.

During motor deceleration, energy from a rotating load can return toward the drive.

Applications involving large inertia may therefore require additional braking or regenerative-energy management depending on the required stopping profile.

Examples include:

  • High-inertia fans.
  • Large conveyors.
  • Centrifuges.
  • Large rotating process machines.
  • Rapid-stop applications.
  • Frequent acceleration/deceleration cycles.

Before using this drive on such equipment, the complete stopping strategy should be evaluated.

15. HIM Configuration

The AN0 configuration is supplied with a Blank / No HIM arrangement.

This means that the catalog configuration does not include the enhanced LCD full-numeric local operator interface associated with the JN4 configuration.

This distinction is important when comparing:

20G1AJC770AN0NNNNN

with:

20G1AJC770AN4NNNNN

or:

20G1AJC770JN4NNNNN

The drive itself may be part of the same broad electrical family, but the operator-interface configuration is different.

For installations where technicians need frequent local access to drive parameters, diagnostics, and operating information, the appropriate HIM configuration should be considered during selection.

16. Product Applications

16.1 Large Water Pumping Systems

Large water pumps are one of the strongest application areas for a drive in the 770 A class.

A variable-speed drive can adjust pump speed according to process requirements.

Typical applications include:

  • Raw-water pumping.
  • Water transfer.
  • Cooling-water circulation.
  • Industrial process-water systems.
  • Large irrigation systems.
  • Water-treatment facilities.
  • Municipal-scale pumping equipment.
  • High-capacity circulation systems.

16.2 Wastewater Treatment

Large wastewater facilities use many high-power motors.

Potential applications include:

  • Influent pumps.
  • Effluent pumps.
  • Aeration blowers.
  • Sludge pumps.
  • Process-water pumps.
  • Large ventilation systems.

The high output-current capacity of the 20G1AJC770AN0NNNNN makes it suitable for large motor installations where smaller drives would not provide adequate capacity.

16.3 Large Fans

Industrial fans can consume substantial motor power.

The drive can be used for:

  • Furnace fans.
  • Exhaust fans.
  • Cooling fans.
  • Process ventilation.
  • Combustion-air fans.
  • Dust-extraction fans.
  • Mine ventilation.
  • Large HVAC fans.

Variable-speed control allows airflow to be adjusted to the process requirement.

16.4 Large Blowers

Large blowers are another natural application.

Potential systems include:

  • Aeration blowers.
  • Process-air blowers.
  • Industrial ventilation.
  • Combustion systems.
  • Pneumatic-process air systems.
  • Dust-control systems.

16.5 Conveyor Systems

Large conveyors frequently require high motor power.

A VFD can provide controlled acceleration and deceleration.

This can help reduce mechanical shock on:

  • Belts.
  • Gearboxes.
  • Couplings.
  • Shafts.
  • Bearings.
  • Conveyor structures.

For long conveyors, controlled speed operation can also provide better coordination with upstream and downstream equipment.

16.6 Mining Applications

Mining equipment often combines high motor power with demanding mechanical conditions.

Potential applications include:

  • Belt conveyors.
  • Crushers.
  • Large fans.
  • Dewatering pumps.
  • Material-handling systems.
  • Processing equipment.
  • Ore-handling systems.
  • Auxiliary machinery.

16.7 Cement and Aggregate Plants

Cement plants contain many large rotating machines.

The drive can be considered for:

  • Process fans.
  • Large conveyors.
  • Crushers.
  • Material-handling equipment.
  • Dust-collection systems.
  • Large pumps.
  • Auxiliary process machinery.

16.8 Industrial HVAC

Large industrial HVAC installations can contain motors requiring hundreds of kilowatts.

Potential applications include:

  • Chilled-water pumps.
  • Condenser-water pumps.
  • Large air-handling fans.
  • Cooling-tower fans.
  • Process ventilation.
  • Exhaust systems.

16.9 General Process Industry

The 20G1AJC770AN0NNNNN can also be considered for large rotating equipment used in:

  • Chemical processing.
  • Steel production.
  • Paper manufacturing.
  • Metal processing.
  • General manufacturing.
  • Bulk-material handling.
  • Industrial utilities.
  • Large process plants.

17. Major Product Advantages

17.1 Very High Current Capacity

The 770 A output rating is the primary advantage of this model.

It provides a substantial current margin for large industrial motors and places the drive in a high-power category.

For applications where a 650 A or 750 A drive is close to the required motor current, the 770 A configuration can provide additional capacity.

17.2 Strong Heavy-Duty Rating

The drive provides a 355 kW Heavy-Duty rating.

This is particularly valuable when compared with the 750 A model, which has a 315 kW Heavy-Duty rating.

Therefore, the 770 A model is not simply a small current increase over the 750 A version.

It also provides a meaningful increase in Heavy-Duty capability.

17.3 400 kW Normal-Duty Capability

The 400 kW Normal-Duty rating makes this model suitable for many large industrial motor applications.

It is particularly attractive for large pumps, fans, blowers, and other variable-speed loads.

17.4 450 kW Light-Duty Capability

The 450 kW Light-Duty rating provides an even higher capacity for applications with less demanding overload requirements.

This makes the drive suitable for large variable-torque loads where the duty profile is appropriate.

17.5 Embedded Industrial Networking

Embedded EtherNet/IP makes the drive well suited to modern plant automation.

The drive can exchange operational and diagnostic information with the broader control system without relying exclusively on hardwired control signals.

17.6 Large MCC-Style Construction

The 800 mm deep MCC-style arrangement is appropriate for centralized industrial electrical systems.

This is especially useful for projects where multiple high-power drives are installed in organized electrical lineups.

17.7 Type 12 / IP54 Protection

The enclosed construction provides protection suitable for many industrial electrical-room environments.

It is more appropriate for dusty industrial environments than an open-frame drive, assuming the environmental conditions remain within the intended application range.

17.8 Forced-Air Cooling

Forced-air cooling allows the drive to handle the substantial thermal load associated with its high-current power electronics.

For large industrial installations, this also makes ventilation and fan maintenance important parts of the maintenance program.

17.9 Broad Application Range

The 770 A configuration can cover a wide range of large industrial machines.

Its application range extends from pumps and fans to conveyors, mining equipment, blowers, process machinery, and industrial utility systems.

18. Five Recommended Related PowerFlex 755 Models

The following five models are particularly relevant when comparing the 20G1AJC770AN0NNNNN with nearby 400 VAC PowerFlex 755 configurations.

Model Input Current Light Duty Normal Duty Heavy Duty Frame Enclosure Cooling
20G1AJC460AN0NNNNN 400 VAC, 3 PH 460 A 315 kW 250 kW 200 kW 8 Type 12 / IP54 Forced Air
20G1AJC540AN0NNNNN 400 VAC, 3 PH 540 A 315 kW 315 kW 250 kW 8 Type 12 / IP54 Forced Air
20G1AJC567AN0NNNNN 400 VAC, 3 PH 567 A 355 kW 315 kW 250 kW 8 Type 12 / IP54 Forced Air
20G1AJC650AN0NNNNN 400 VAC, 3 PH 650 A 400 kW 355 kW 315 kW 8 Type 12 / IP54 Forced Air
20G1AJC750AN0NNNNN 400 VAC, 3 PH 750 A 450 kW 400 kW 315 kW 8 Type 12 / IP54 Forced Air

These models form a useful current-capacity progression from 460 A through 770 A.

The published selection data identify the 460 A, 540 A, 567 A, 650 A, 750 A, and 770 A models as Frame 8 configurations in the 380–400 VAC class.

19. Comparison of Related Models

Model Output Current LD ND HD Best Selection Position
20G1AJC460AN0NNNNN 460 A 315 kW 250 kW 200 kW Lower-capacity Frame 8 application
20G1AJC540AN0NNNNN 540 A 315 kW 315 kW 250 kW General high-power application
20G1AJC567AN0NNNNN 567 A 355 kW 315 kW 250 kW Higher Light-Duty requirement
20G1AJC650AN0NNNNN 650 A 400 kW 355 kW 315 kW Higher Normal/Heavy-Duty requirement
20G1AJC750AN0NNNNN 750 A 450 kW 400 kW 315 kW Very large Normal-Duty load
20G1AJC770AN0NNNNN 770 A 450 kW 400 kW 355 kW Highest capacity in this comparison

The 20G1AJC770AN0NNNNN is particularly attractive when Heavy-Duty capacity matters.

Compared with the 750 A version, the 770 A model increases Heavy-Duty capacity from 315 kW to 355 kW.

This can be an important difference for applications with higher torque or overload requirements.

20. Five Recommended Models From the Same Brand

The following models are useful representative Allen-Bradley drive models for comparison across different power levels and applications.

Model Product Series Voltage Class Output / Power Class Frame Enclosure / Construction Typical Application
25B-D030N114 PowerFlex 525 480 VAC class 30 A class Compact Enclosed compact drive Pumps, fans, conveyors, machinery
25C-D030N114 PowerFlex 527 480 VAC class 30 A class Compact Machine-level drive Networked machine automation
20G1AGE053JA0NNNNN PowerFlex 755 600 VAC, 3 PH 53 A / 50 HP ND Frame 6 Type 12 / IP54 Industrial pumps and machinery
20G1AGC260JN0NNNNN PowerFlex 755 400 VAC, 3 PH 260 A / 132 kW ND Frame 7 Type 12 / IP54 Large pumps, fans, conveyors
20G1AND302JA0NNNNN PowerFlex 755 480 VAC, 3 PH 302 A / 250 HP ND Frame 7 Open type Large industrial motor control

These models represent different levels of motor-control capacity.

The 25B-D030N114 and 25C-D030N114 are much smaller and are more appropriate for machine-level applications.

The 20G1AGC260JN0NNNNN and 20G1AND302JA0NNNNN move into significantly larger industrial motor applications.

The 20G1AGE053JA0NNNNN provides an example of a higher-voltage PowerFlex 755 configuration.

21. 20G1AJC770AN0NNNNN vs. 20G1AJC750AN0NNNNN

Parameter 20G1AJC750AN0NNNNN 20G1AJC770AN0NNNNN
Input 400 VAC, 3 PH 400 VAC, 3 PH
Current 750 A 770 A
Light Duty 450 kW 450 kW
Normal Duty 400 kW 400 kW
Heavy Duty 315 kW 355 kW
Frame 8 8
Enclosure Type 12 / IP54 Type 12 / IP54
MCC Depth 800 mm 800 mm
Cooling Forced Air Forced Air
Dynamic Braking None None
Input AC with Precharge AC with Precharge
HIM Blank / No HIM Blank / No HIM
Main Difference Lower HD capacity Higher HD capacity

The 770 A version is a logical step above the 750 A version.

The most significant practical difference is the Heavy-Duty rating.

The 750 A version provides 315 kW Heavy Duty, while the 770 A version provides 355 kW Heavy Duty.

Therefore, if the application has a demanding duty cycle, the 770 A version may provide a more suitable current envelope.

22. 20G1AJC770AN0NNNNN vs. 20G1AJC650AN0NNNNN

Parameter 20G1AJC650AN0NNNNN 20G1AJC770AN0NNNNN
Input Voltage 400 VAC 400 VAC
Output Current 650 A 770 A
Light Duty 400 kW 450 kW
Normal Duty 355 kW 400 kW
Heavy Duty 315 kW 355 kW
Frame 8 8
Enclosure Type 12 / IP54 Type 12 / IP54
MCC Depth 800 mm 800 mm
Cooling Forced Air Forced Air
Dynamic Braking None None
HIM Blank / No HIM Blank / No HIM

The 770 A model provides a significant increase in current capacity over the 650 A model.

It also increases the power rating across all three duty categories.

This makes the 770 A version a stronger choice for motors approaching the upper end of the 650 A drive’s practical operating range.

23. Replacement Consideration

The original 20G1AJC770AN0NNNNN has been discontinued.

The listed direct replacement is:

20G1AJC770JN0NNNNN.

The replacement model should be considered when purchasing new equipment or replacing an existing drive.

However, a replacement should always be evaluated against the complete installation rather than based only on catalog-number similarity.

The following should be checked:

  • Motor current.
  • Motor voltage.
  • Duty classification.
  • Input power.
  • Grounding arrangement.
  • EMC requirements.
  • Common-mode configuration.
  • Network configuration.
  • HIM requirements.
  • Dynamic braking requirements.
  • Existing control wiring.
  • Existing drive parameters.
  • Motor cable arrangement.
  • Cabinet dimensions.
  • Cooling requirements.
  • Maintenance requirements.

The AN0-to-JN0 change is especially relevant because the catalog configuration changes the filter/common-mode jumper arrangement.

24. Installation Considerations

Electrical Supply

The incoming electrical system must be suitable for the 400 VAC three-phase drive configuration.

The upstream protection system should be designed according to the electrical requirements of the installation.

The incoming supply, disconnecting means, protective devices, grounding system, and cable sizing should be engineered as a complete system.

Motor Cable

The motor cable must be correctly selected for:

  • Motor current.
  • Cable length.
  • Installation environment.
  • Insulation requirements.
  • Grounding arrangement.
  • EMC requirements.
  • Temperature.
  • Mechanical installation conditions.

Grounding

Proper grounding is particularly important for large variable-frequency-drive installations.

The drive enclosure, motor, motor cable shield, cabinet, and associated control equipment should be incorporated into a properly engineered grounding system.

Ventilation

The drive uses forced-air cooling.

Therefore, the electrical room or enclosure must provide adequate airflow.

Hot exhaust air should not simply recirculate into the drive’s cooling inlet.

For installations containing several large drives, the total heat load of the room should be calculated.

Cable Routing

High-power motor cables should be routed appropriately and separated from sensitive control and communication wiring where required.

Good cable management is important for both EMC performance and maintenance.

25. Maintenance

A drive of this size should be included in a structured preventive-maintenance program.

Typical inspection activities include:

  • Inspecting cooling fans.
  • Checking airflow.
  • Cleaning ventilation paths.
  • Inspecting cabinet cleanliness.
  • Checking electrical connections.
  • Checking grounding connections.
  • Reviewing fault history.
  • Reviewing temperature conditions.
  • Inspecting motor cables.
  • Inspecting enclosure condition.
  • Checking network communications.
  • Monitoring unusual noise.
  • Checking signs of overheating.
  • Verifying operator/control-system communications.

Because this is a high-power floor-standing drive, maintenance should be performed by appropriately qualified personnel under the applicable electrical safety procedures.

26. Engineering Selection Checklist

Selection Item Requirement for Evaluation
Motor Voltage Confirm compatibility with 400 VAC-class system
Motor Current Compare with applicable drive-duty current
Motor Power Compare with LD / ND / HD rating
Duty Cycle Determine Light, Normal, or Heavy Duty
Acceleration Evaluate required acceleration torque
Load Inertia Calculate motor/load inertia
Deceleration Evaluate regenerative energy
Braking Determine whether external braking is necessary
Input Supply Confirm three-phase supply
Enclosure Confirm Type 12 / IP54 requirement
Installation Depth Allow for 800 mm MCC-style configuration
Cooling Provide sufficient forced-air ventilation
Communications Confirm EtherNet/IP requirements
HIM AN0 configuration has no HIM
EMC Review filter, grounding, shielding and cable routing
Weight Confirm final equipment/shipping weight
Dimensions Confirm final mechanical drawing
Maintenance Provide adequate service clearance
Replacement Check current replacement configuration

The most important selection criterion is the actual motor current under the intended operating duty.

The motor’s nominal kW value should be considered together with current, duty cycle, overload requirements, acceleration requirements, and mechanical load characteristics.

27. Typical Large-Industrial Applications

Application Typical Equipment Reason for Using a High-Power VFD
Water Treatment Large pumps Flow and pressure control
Wastewater Pumps and blowers Process regulation
Mining Conveyors, fans, pumps High motor power and controlled acceleration
Cement Fans, conveyors, process machinery Variable-speed process control
Steel Fans, pumps, process equipment High-power motor regulation
Manufacturing Large machinery Speed and torque control
HVAC Large fans and pumps Airflow and water-flow control
Material Handling Conveyors Controlled acceleration and speed
Process Industry Pumps, mixers, blowers Process optimization
Industrial Utilities Pumps and fans Energy and process control

The drive is particularly well suited to applications where the motor is too large for compact machine-level drives and where centralized industrial automation is required.

28. Overall Advantages of the 20G1AJC770AN0NNNNN

The principal strengths of the 20G1AJC770AN0NNNNN can be summarized as follows:

  1. 770 A high-current output capacity.
  2. 450 kW Light-Duty capability.
  3. 400 kW Normal-Duty capability.
  4. 355 kW Heavy-Duty capability.
  5. 400 VAC three-phase operation.
  6. Large Frame 8 architecture.
  7. 800 mm deep MCC-style construction.
  8. Type 12 / IP54 enclosure.
  9. Forced-air cooling.
  10. Embedded EtherNet/IP communication.
  11. EMC filtering.
  12. AC input with precharge.
  13. No unnecessary internal dynamic-braking configuration for applications that do not require it.
  14. Wide range of industrial applications.
  15. Strong compatibility with centralized automation architectures.
  16. Suitable for large pumps, fans, blowers and conveyors.
  17. Useful for mining, cement, water, wastewater and process industries.
  18. Higher Heavy-Duty capacity than the nearby 750 A configuration.
  19. Large enclosure format suitable for industrial MCC-style installations.
  20. Extensive current-capacity options within the same PowerFlex 755 family.

29. Final Technical Summary

Category Final Specification
Product PowerFlex 755 AC Drive
Model 20G1AJC770AN0NNNNN
Brand Allen-Bradley
Series PowerFlex 755
Product Family PowerFlex 750-Series
Product Type High-Power Air-Cooled AC Drive
Lifecycle Discontinued
Direct Replacement 20G1AJC770JN0NNNNN
Input Voltage 380–400 VAC class
Nominal Voltage 400 VAC
Phase 3 Phase
Rated Output Current 770 A
Light Duty 450 kW
Normal Duty 400 kW
Heavy Duty 355 kW
Frame Frame 8
Cooling Forced Air
Enclosure Type 12
Protection IP54
MCC Depth 800 mm
Input AC Input with Precharge
DC Terminals None
EMC Filter Yes
CM Jumper Removed
Dynamic Braking None
Communication Embedded EtherNet/IP
HIM Blank / No HIM
Approx. Width ~600 mm class*
Approx. Height ~2,000–2,200 mm*
Approx. Depth ~800 mm
Approx. Weight ~500–700 kg*
Installation Floor-Standing MCC Style
Main Applications Pumps, fans, blowers, conveyors, mining, water, wastewater, cement, process machinery and industrial utilities

*Approximate mechanical planning values only; final dimensions and weight should be verified against the exact configured mechanical documentation.

30. Conclusion

The Allen-Bradley 20G1AJC770AN0NNNNN is a large-capacity PowerFlex 755 AC drive intended for demanding industrial motor-control applications.

Its 770 A output rating, 450 kW Light-Duty rating, 400 kW Normal-Duty rating, and 355 kW Heavy-Duty rating make it one of the stronger 400 VAC Frame 8 configurations in this part of the PowerFlex 755 range.

The combination of Frame 8 construction, 800 mm deep MCC-style packaging, Type 12 / IP54 protection, forced-air cooling, EMC filtering, AC input with precharge, and embedded EtherNet/IP makes it suitable for large centralized industrial drive systems.

From an application perspective, the model is particularly appropriate for large pumps, high-capacity fans, blowers, conveyors, mining machinery, water and wastewater equipment, cement plants, process machinery, industrial HVAC, and other large rotating equipment.

Its biggest technical advantage over the nearby 750 A configuration is the 355 kW Heavy-Duty rating, which provides additional capacity for demanding motor applications.

For new projects, the most important point is that 20G1AJC770AN0NNNNN is a discontinued catalog configuration and 20G1AJC770JN0NNNNN is its listed direct replacement. Replacement selection should include a review of the filtering/common-mode configuration, HIM requirements, control wiring, motor data, braking requirements, dimensions, weight, and installation conditions rather than relying solely on the catalog number.

For final mechanical installation, the exact configured dimensions and shipping weight should be confirmed before procurement or site preparation, especially because this is a large Frame 8, floor-standing drive that may require specialized handling and lifting equipment.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501