• Allen Bradley 20G1AJC750JN0NNNNN PowerFlex AC Drive
  • Allen Bradley 20G1AJC750JN0NNNNN PowerFlex AC Drive
  • Allen Bradley 20G1AJC750JN0NNNNN PowerFlex AC Drive
  • Allen Bradley 20G1AJC750JN0NNNNN PowerFlex AC Drive
1. Product Overview The Allen-Bradley 20G1AJC750JN0NNNNN is a high-power PowerFlex 755 AC Drive designed for large three-phase industrial motors where high current capacity, variable-speed operation, ne……
Allen Bradley 20G1AJC750JN0NNNNN PowerFlex AC Drive
  • Allen Bradley
  • 20G1AJC750JN0NNNNN
  • PowerFlex AC Drive
  • USA
  • 2102 × 606 × 600 mm
  • 650kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 34

Our advantage

Allen Bradley 20G1AJC750JN0NNNNN PowerFlex AC Drive

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Allen Bradley 20G1AJC750JN0NNNNN PowerFlex AC Drive

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Allen Bradley 20G1AJC750JN0NNNNN PowerFlex AC Drive

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Allen Bradley 20G1AJC750JN0NNNNN PowerFlex AC Drive

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

1. Product Overview

The Allen-Bradley 20G1AJC750JN0NNNNN is a high-power PowerFlex 755 AC Drive designed for large three-phase industrial motors where high current capacity, variable-speed operation, networked control, and industrial enclosure protection are required.

This model is a 400 VAC, three-phase, 750 A Frame 8 drive. Its published capacity is 450 kW Light Duty, 400 kW Normal Duty, and 315 kW Heavy Duty.

The drive uses a forced-air-cooled power section and an IP54 / NEMA Type 12, 800 mm deep MCC-style enclosure. It includes embedded EtherNet/IP, an AC input with precharge, no DC terminals, filtering, and an installed common-mode jumper.

The configuration is specified as No Dynamic Braking and Blank / No HIM, making it particularly appropriate for installations in which drive operation and monitoring are handled through a PLC, HMI, SCADA system, or industrial Ethernet network rather than through a permanently mounted local operator panel. 

The 20G1AJC750JN0NNNNN is also the direct replacement configuration for the earlier 20G1AJC750AN0NNNNN, which was discontinued on June 30, 2024.

The JN0 version therefore has particular importance for modernization projects, replacement projects, spare-parts planning, and new installations requiring this specific high-power 400 VAC configuration. 


2. Brand and Product Series

Item Specification
Brand Allen-Bradley
Product Family PowerFlex
Product Series PowerFlex 755
Product Type Air-Cooled AC Drive
Catalog Number 20G1AJC750JN0NNNNN
Drive Category High-Power Industrial AC Drive
Voltage Class 400 VAC
Input Phase 3 Phase
Rated Normal-Duty Current 750 A
Light-Duty Rating 450 kW
Normal-Duty Rating 400 kW
Heavy-Duty Rating 315 kW
Frame Frame 8
Cooling Forced Air
Enclosure IP54 / NEMA Type 12
Cabinet Style 800 mm Deep MCC Style
Communication Embedded EtherNet/IP
Input Configuration AC Input with Precharge
DC Terminals None
Filtering Filtered
CM Jumper Installed
Dynamic Braking None
HIM Blank / No HIM
Product Status Active
Related Previous Model 20G1AJC750AN0NNNNN
Product Class Large Industrial Variable-Frequency Drive

The model belongs to the PowerFlex 755 series, a high-performance industrial AC-drive family intended for larger motors and more demanding industrial machinery.

The catalog configuration specifically identifies the 750 A model as an air-cooled PowerFlex 755 with embedded EtherNet/IP, 400 VAC three-phase input, Frame 8 construction, IP54 / Type 12 protection, and an 800 mm deep MCC-style package. 


3. Detailed Technical Parameters

Technical Parameter Specification
Model / Catalog Number 20G1AJC750JN0NNNNN
Brand Allen-Bradley
Series PowerFlex 755
Product Type Air-Cooled AC Drive
Input Voltage 400 VAC nominal
Input Phase 3 Phase
Normal-Duty Output Current 750 A
Light-Duty Continuous Current 796 A class
Light-Duty 1-Minute Current 876 A class
Normal-Duty Continuous Current 750 A
Normal-Duty 1-Minute Current 825 A
Normal-Duty 3-Second Current 1125 A
Heavy-Duty Continuous Current 585 A
Heavy-Duty 1-Minute Current 878 A
Heavy-Duty 3-Second Current 1053 A class
Light-Duty Power 450 kW
Normal-Duty Power 400 kW
Heavy-Duty Power 315 kW
Frame Size Frame 8
Cooling Forced Air
Enclosure Rating IP54
Enclosure Type NEMA Type 12
Cabinet Style 800 mm Deep MCC Style
Input Type AC Input with Precharge
DC Terminals None
Communication Embedded EtherNet/IP
EMC / Filtering Filtered
CM Jumper Installed
Dynamic Braking None
HIM Blank / No HIM
Local Keypad Not Included
Control Characteristic PID capable
Integrated Motion No
Safety Functions Suitable for supported safety applications with appropriate configuration
Approx. Width 600 mm class
Approx. Height 2,000–2,200 mm class
Approx. Depth 800 mm
Approx. Weight 500–700 kg
Installation Floor-standing / MCC-style
Operating Temperature Approximately -20 to +60 °C, subject to rating conditions
Storage Temperature Approximately -40 to +70 °C
Typical Application Large industrial motors
Product Status Active

The core published electrical data identifies this model as a 400 V, three-phase, 750 A PowerFlex 755, with 400 kW Normal Duty and 315 kW Heavy Duty ratings. The broader PowerFlex selection data gives the 750 A configuration a 450 kW Light-Duty rating and identifies it as a Frame 8 model. 

The approximate dimensions and weight are intended for preliminary engineering planning. The final mechanical drawing should be used for exact cabinet dimensions, lifting arrangements, floor loading, shipping weight, and installation clearances.


4. Product Description

The 20G1AJC750JN0NNNNN is intended for applications where a standard small or medium variable-frequency drive is insufficient for the motor’s current and power requirements.

At 750 A, this drive is positioned toward the high-current end of the 400 VAC PowerFlex 755 range.

Its 400 kW Normal-Duty rating makes it suitable for very large industrial motors.

The 450 kW Light-Duty rating is particularly relevant to variable-torque equipment, while the 315 kW Heavy-Duty rating provides a substantial capacity for applications requiring greater overload capability.

The drive is designed as an industrial packaged unit rather than a compact machine-mounted inverter.

Its Frame 8 construction, forced-air cooling, and 800 mm deep MCC-style enclosure make it more appropriate for centralized electrical rooms, motor-control centers, process plants, utility rooms, and large industrial installations. 

The embedded EtherNet/IP interface allows the drive to become part of a larger automation system.

Rather than requiring every operating command to be performed locally, the drive can receive speed references, start/stop commands, status information, and diagnostic information from the plant control system.

The JN0 configuration deliberately does not include a local HIM.

This makes it a practical configuration for plants that use centralized operator stations or network-based control.


5. Electrical Rating

The drive is designed for a 400 VAC three-phase industrial power supply.

Its principal output rating is 750 A Normal Duty.

This is a substantial current level and places the unit in the large-drive category.

The motor should be selected according to actual full-load current rather than simply using motor horsepower as the only selection criterion.

For example, two motors with the same nominal kW rating may have different full-load currents because of differences in:

  • Motor efficiency.
  • Power factor.
  • Voltage.
  • Speed.
  • Motor design.
  • Operating temperature.
  • Duty.

The drive selection should therefore begin with the actual motor nameplate data and application load profile.


6. Duty Ratings

The model supports different current and power ratings according to application duty.

Duty Classification Current Class Power Rating Typical Application
Light Duty 796 A class 450 kW Variable-torque applications
Normal Duty 750 A 400 kW General industrial loads
Heavy Duty 585 A 315 kW High-torque / demanding overload loads

The difference between these ratings is important.

A pump or fan may be able to use the higher Light-Duty rating because its torque generally varies with speed.

A conveyor, mixer, or other high-torque machine may require a more conservative Heavy-Duty selection.

The 315 kW Heavy-Duty rating should therefore not be interpreted as a limitation of the drive’s overall power capability.

It reflects the thermal and overload requirements associated with more demanding duty conditions.

The selection guide also identifies the 750 A model with substantial short-duration current capability, which can be important during acceleration and transient load conditions. 


7. Light-Duty Applications

The 450 kW Light-Duty rating makes this drive particularly attractive for variable-torque equipment.

Typical examples include:

  • Centrifugal water pumps.
  • Large cooling-water pumps.
  • Industrial fans.
  • Large ventilation fans.
  • Centrifugal blowers.
  • HVAC equipment.
  • Process-air systems.

For these applications, reducing motor speed can substantially reduce the mechanical power required by the load.

The drive can therefore provide both process-control and potential energy-efficiency benefits.


8. Normal-Duty Applications

The 400 kW Normal-Duty rating is suitable for many large industrial applications.

Typical examples include:

  • Large process pumps.
  • Large conveyors.
  • Material-handling systems.
  • Industrial fans.
  • Blowers.
  • Process machinery.
  • Large mixers.
  • Manufacturing equipment.

The Normal-Duty rating provides a useful balance between motor capacity and overload requirements.


9. Heavy-Duty Applications

The Heavy-Duty rating is 315 kW at 585 A continuous current.

Heavy-Duty selection becomes more important where the machine requires higher torque or repeated overload operation.

Potential applications include:

  • Heavy conveyors.
  • High-inertia machinery.
  • Large mixers.
  • Material-handling equipment.
  • Certain crushers.
  • Machinery with demanding acceleration requirements.

The correct Heavy-Duty selection depends on the actual motor current and load profile.


10. Frame 8 Architecture

The Frame 8 designation indicates that this is a large physical and electrical drive platform.

Frame 8 equipment requires considerably more installation space than compact drive frames.

The installation should therefore consider:

  • Cabinet footprint.
  • Cable access.
  • Front service clearance.
  • Cooling-air circulation.
  • Lifting requirements.
  • Floor loading.
  • Transportation route.
  • Electrical-room HVAC.

The PowerFlex selection data groups the 750 A configuration with other large Frame 8 models such as the 460 A, 540 A, 567 A, 650 A, and 770 A versions. 


11. IP54 / NEMA Type 12 Enclosure

The enclosure is specified as IP54 / NEMA Type 12.

This provides a protected industrial package appropriate for many indoor industrial installations.

Potential locations include:

  • Electrical rooms.
  • MCC rooms.
  • Pump stations.
  • Water-treatment facilities.
  • Manufacturing plants.
  • Cement plants.
  • Mining facilities.
  • Process plants.
  • Industrial utility rooms.

The enclosure protection does not eliminate the need for environmental control.

The installation should still be protected from excessive:

  • Dust.
  • Moisture.
  • Condensation.
  • Corrosive chemicals.
  • Excessive heat.
  • Poor-quality cooling air.

12. 800 mm Deep MCC-Style Construction

The drive uses an 800 mm deep MCC-style configuration.

This is important when planning a new electrical room or replacing an existing large drive.

The physical installation needs adequate space for:

  • Incoming power cables.
  • Motor output cables.
  • Control wiring.
  • Ethernet connections.
  • Cooling airflow.
  • Service access.
  • Maintenance equipment.

The 800 mm depth should therefore be included in the electrical-room layout.

For replacement projects, the existing cabinet should be measured before ordering.

Cable-entry positions should also be compared.


13. Forced-Air Cooling

The drive uses forced-air cooling.

Large semiconductor devices and other power components generate substantial heat during operation.

The cooling system removes heat from:

  • Power semiconductor modules.
  • DC bus components.
  • Capacitors.
  • Filters.
  • Internal power assemblies.

The electrical room must therefore provide adequate ventilation and HVAC capacity.

Air inlet and exhaust areas should remain unobstructed.

Cooling fans should be inspected as part of routine preventive maintenance.


14. Embedded EtherNet/IP

One of the important features of the 20G1AJC750JN0NNNNN is its embedded EtherNet/IP capability.

This allows the drive to participate directly in an industrial Ethernet architecture.

Typical information exchanged with the control system can include:

  • Start command.
  • Stop command.
  • Speed reference.
  • Frequency reference.
  • Drive status.
  • Output current.
  • Motor speed.
  • Fault status.
  • Alarm status.
  • Diagnostic information.
  • Operating state.

This is particularly valuable in large plants where many motors are controlled from centralized automation equipment.

The drive can function as an intelligent motor-control node within the overall automation architecture.


15. No HIM Configuration

The model is configured as Blank / No HIM.

This is a deliberate configuration characteristic.

It is especially useful where the drive is normally controlled through:

  • PLC.
  • HMI.
  • SCADA.
  • DCS.
  • Plant Ethernet.
  • Central control room.

The absence of a local HIM can also be useful where the electrical cabinet is not intended to function as a local operator station.

For installations requiring direct local parameter access, a related JN4 configuration with a protected HIM may be more appropriate.


16. Filtered Configuration

The drive is specified as Filtered.

Filtering is important in large variable-frequency-drive installations because switching devices generate high-frequency electrical components during normal operation.

The complete installation should consider:

  • Motor cable construction.
  • Cable length.
  • Grounding.
  • Shielding.
  • EMC requirements.
  • Instrumentation.
  • Communication wiring.
  • Nearby sensitive electronic equipment.

The drive should be installed according to the applicable electrical and EMC requirements for the specific plant.


17. CM Jumper Installed

The configuration specifies the CM jumper as installed.

This is an important distinction when comparing it with some older configurations where the jumper may have been removed.

The common-mode configuration should be considered together with the complete motor-drive-grounding system.

When replacing an existing drive, the existing jumper configuration should be documented before installation.


18. AC Input with Precharge

The model uses an AC input with precharge and does not provide DC terminals in this configuration. 

The precharge arrangement is particularly relevant to a high-power drive because the DC bus contains significant stored electrical energy.

Controlled charging of the DC bus helps manage the initial energization process.

The incoming electrical system must still be correctly sized.

The following should be reviewed:

  • Transformer rating.
  • Feeder rating.
  • Circuit protection.
  • Disconnect equipment.
  • Cable size.
  • Grounding.
  • Available fault current.

19. Dynamic Braking

The catalog configuration specifies No Dynamic Braking.

This is appropriate for many pump and fan applications where the load does not require aggressive deceleration.

However, braking requirements should be reviewed for applications involving:

  • High-inertia loads.
  • Frequent stopping.
  • Rapid deceleration.
  • Large conveyors.
  • Material handling.
  • Large rotating machinery.

If the machine returns significant energy to the drive during deceleration, an appropriate braking strategy should be evaluated separately.


20. Main Product Applications

20.1 Large Water Pumps

The drive is highly suitable for large water-pumping systems.

Typical applications include:

  • Raw-water pumps.
  • Cooling-water pumps.
  • Transfer pumps.
  • Industrial water systems.
  • Process-water pumps.
  • High-capacity irrigation systems.
  • Municipal pumping.

The drive can adjust motor speed to match actual flow requirements.

This can provide more precise process control than simple fixed-speed operation.


20.2 Wastewater Treatment

Large wastewater facilities frequently use motors in the hundreds-of-kilowatts range.

Potential applications include:

  • Lift pumps.
  • Transfer pumps.
  • Sludge pumps.
  • Aeration blowers.
  • Process-water pumps.
  • Ventilation equipment.

The high-current rating is suitable for large pump motors.

The embedded Ethernet interface also makes integration into centralized plant control practical.


20.3 Large Industrial Fans

Large fans are another strong application.

Examples include:

  • Furnace fans.
  • Exhaust fans.
  • Dust-collection fans.
  • Cooling fans.
  • Process ventilation.
  • Kiln fans.
  • Combustion-air systems.
  • Industrial HVAC.

For variable-torque fan loads, the 450 kW Light-Duty rating can provide substantial application capacity.


20.4 Large Blowers

Large blowers can require substantial motor power.

Possible applications include:

  • Aeration.
  • Process-air systems.
  • Pneumatic material handling.
  • Furnace systems.
  • Combustion systems.
  • Industrial ventilation.

Variable-speed operation can allow airflow to follow process demand.


20.5 Mining Conveyors

Large mining conveyors can place substantial demands on motor-control equipment.

Applications include:

  • Ore conveyors.
  • Coal conveyors.
  • Aggregate conveyors.
  • Transfer conveyors.
  • Long belt conveyors.

The 750 A drive can provide the current capacity required by large conveyor motors.

However, conveyor applications should receive specific analysis of:

  • Starting torque.
  • Belt tension.
  • Acceleration time.
  • Load inertia.
  • Stopping time.
  • Regenerative energy.

20.6 Cement Plants

Large cement and aggregate facilities contain many high-power motors.

The drive can be used for:

  • Conveyors.
  • Large fans.
  • Blowers.
  • Process pumps.
  • Material handling.
  • Dust collection.
  • Cooling systems.

The PowerFlex 755 platform also makes it possible to standardize drive technology across multiple motor sizes.


20.7 Industrial Process Equipment

The model can be used for large process machinery where variable-speed motor control is required.

Potential applications include:

  • Large mixers.
  • Pumps.
  • Blowers.
  • Fans.
  • Process machinery.
  • Industrial utilities.
  • Material-processing systems.

The final selection should always be based on the motor’s actual torque-speed curve.


21. Product Advantages

21.1 750 A High-Current Capability

The most obvious advantage is the 750 A current rating.

This allows the drive to serve motors considerably larger than those handled by compact VFDs.

It is particularly useful where the motor current is close to the upper range of conventional industrial drives.


21.2 450 kW Light-Duty Capacity

The 450 kW Light-Duty capability makes the drive particularly attractive for large variable-torque loads.

This includes:

  • Large pumps.
  • Fans.
  • Blowers.
  • Ventilation systems.

21.3 400 kW Normal-Duty Capacity

The 400 kW Normal-Duty rating provides substantial capacity for general industrial machinery.

It represents a useful balance between high power and normal industrial overload requirements.


21.4 315 kW Heavy-Duty Capacity

The Heavy-Duty rating allows the drive to support demanding applications where greater overload performance is needed.


21.5 Embedded EtherNet/IP

Integrated EtherNet/IP communication simplifies integration into industrial control networks.

This can reduce the need for separate communication hardware and provide direct access to drive status and control information.


21.6 IP54 / NEMA Type 12 Construction

The protected enclosure is suitable for many industrial electrical-room environments.

It provides a much more protected physical package than an open-frame configuration.


21.7 Frame 8 High-Power Architecture

Frame 8 provides the physical and electrical platform necessary for high-current motor control.


21.8 MCC-Style Construction

The 800 mm deep MCC-style arrangement is well suited to centralized industrial installations.


21.9 No Local HIM

Although the absence of a HIM can be a disadvantage for applications requiring local operation, it is an advantage for centralized control systems.

The drive can remain integrated into the plant automation architecture without requiring a local operator interface.


22. Dimensions and Weight

The model is a large Frame 8 packaged drive.

For preliminary engineering planning, the following mechanical values are appropriate.

Mechanical Parameter Approximate Specification
Model 20G1AJC750JN0NNNNN
Frame Frame 8
Enclosure IP54 / NEMA Type 12
Cabinet Style 800 mm Deep MCC Style
Approx. Width 600 mm class
Approx. Height 2,000–2,200 mm class
Approx. Depth 800 mm
Approx. Weight 500–700 kg
Installation Floor-standing
Cooling Forced Air
Equipment Category Heavy Industrial
Service Access Front service area required
Handling Heavy-duty lifting equipment recommended

The catalog configuration confirms the 800 mm deep MCC-style construction and Frame 8 architecture. 

The exact mechanical dimensions and complete shipping weight should be verified from the final equipment drawing.

The approximate 500–700 kg weight range is intended for preliminary planning and should not be treated as a certified shipping weight.

For foundation design, lifting calculations, transportation, and final cabinet layout, the actual supplied configuration should be used.


23. Installation Requirements

The 20G1AJC750JN0NNNNN should be planned as major industrial electrical equipment.

The installation should address both electrical and mechanical requirements.

Electrical Requirements

  • 400 VAC three-phase supply.
  • Proper transformer capacity.
  • Correct feeder sizing.
  • Suitable circuit protection.
  • Proper grounding.
  • Correct motor cable sizing.
  • Appropriate disconnect equipment.
  • Suitable short-circuit rating.

Mechanical Requirements

  • Adequate cabinet footprint.
  • Adequate front access.
  • Sufficient cooling airflow.
  • Suitable floor loading.
  • Appropriate lifting equipment.
  • Adequate transportation path.
  • Sufficient electrical-room ventilation.

24. Motor Selection Guidelines

The following motor data should be confirmed before final drive selection.

Motor Parameter Required Information
Motor Voltage Rated voltage
Motor Current Full-load current
Motor Power kW / HP
Frequency Hz
Speed RPM
Power Factor Motor PF
Efficiency Motor efficiency
Torque Rated and starting torque
Motor Duty Continuous / intermittent
Cooling Motor cooling method
Insulation Motor insulation system
Operating Cycle Actual duty profile

The motor’s full-load current should be compared directly with the drive’s applicable current rating.

The 750 A figure should not be interpreted as a recommendation to use the drive with any motor below a particular horsepower without considering the actual load.


25. Energy Efficiency and Variable-Speed Operation

One of the major benefits of a variable-frequency drive is the ability to match motor speed to process demand.

This is particularly important for centrifugal pumps and fans.

If the process does not require full flow or full airflow, the motor can operate at a reduced speed rather than remaining at full speed.

This can provide:

  • Lower energy consumption.
  • Better process control.
  • Reduced mechanical stress.
  • Improved system flexibility.
  • Reduced throttling.

The actual energy savings depend on the process and operating schedule.

Variable-speed control does not automatically guarantee energy savings in every application.


26. Process-Control Benefits

The drive can function as more than a motor starter.

It can participate in a complete process-control system.

Typical functions include:

  • Speed regulation.
  • Pressure control.
  • Flow control.
  • Tension control.
  • Process synchronization.
  • Controlled acceleration.
  • Controlled deceleration.
  • Load monitoring.
  • Fault monitoring.
  • Alarm handling.

This makes it suitable for large process systems where motor speed directly affects production output.


27. Network Integration

The embedded EtherNet/IP interface is particularly useful for multi-drive installations.

A plant may have dozens or hundreds of motors.

With networked drives, the control system can monitor drive operating states centrally.

For example, the automation system can determine:

  • Which drive is running.
  • Which drive is stopped.
  • Which drive has a fault.
  • Which motor is drawing excessive current.
  • What speed each motor is operating at.
  • Whether the drive is available.
  • Whether a process interlock is active.

This can simplify plant-wide diagnostics.


28. Maintenance Advantages

The JN0 configuration does not include a local HIM, so maintenance is generally more dependent on the plant’s control and diagnostic architecture.

This can actually be beneficial in large centralized systems.

Maintenance personnel can use the control system to review:

  • Drive status.
  • Fault history.
  • Alarm conditions.
  • Operating parameters.
  • Network status.
  • Motor current.
  • Speed.

Where direct local access is required, a JN4 configuration with an enhanced protected HIM can be considered as a related alternative.


29. Preventive Maintenance

A high-power Frame 8 drive should be included in a structured preventive-maintenance program.

Recommended activities include:

Cooling System

Inspect fans.

Check airflow.

Remove excessive dust.

Inspect air passages.

Check abnormal temperature rise.

Electrical System

Inspect power connections.

Inspect grounding.

Check motor terminals.

Check control wiring.

Check Ethernet connections.

Drive Condition

Review fault history.

Review alarms.

Check unusual noise.

Check unusual vibration.

Inspect enclosure condition.

Check for signs of overheating.


30. Five Recommended Same-Series or Related Models

The following models are particularly relevant to the 20G1AJC750JN0NNNNN.

Model Voltage Current LD Power ND Power HD Power Frame Enclosure
20G1AJC460JN0NNNNN 400 VAC 460 A 315 kW 250 kW 200 kW 8 IP54 / Type 12
20G1AJC540JN0NNNNN 400 VAC 540 A 315 kW 315 kW 250 kW 8 IP54 / Type 12
20G1AJC567JN0NNNNN 400 VAC 567 A 355 kW 315 kW 250 kW 8 IP54 / Type 12
20G1AJC650JN0NNNNN 400 VAC 650 A 400 kW 355 kW 315 kW 8 IP54 / Type 12
20G1AJC770JN0NNNNN 400 VAC 770 A 450 kW 400 kW 355 kW 8 IP54 / Type 12

These models form a practical current-capacity progression around the 750 A configuration.

The 460 A, 540 A, 567 A, 650 A, 750 A, and 770 A configurations are all part of the same high-power Frame 8 group. 


31. Related Model Comparison

Model Current LD ND HD Relative Position
20G1AJC460JN0NNNNN 460 A 315 kW 250 kW 200 kW Lower capacity
20G1AJC540JN0NNNNN 540 A 315 kW 315 kW 250 kW Lower-middle capacity
20G1AJC567JN0NNNNN 567 A 355 kW 315 kW 250 kW Intermediate capacity
20G1AJC650JN0NNNNN 650 A 400 kW 355 kW 315 kW Lower than 750 A
20G1AJC750JN0NNNNN 750 A 450 kW 400 kW 315 kW Reference model
20G1AJC770JN0NNNNN 770 A 450 kW 400 kW 355 kW Higher capacity

The 20G1AJC650JN0NNNNN is a particularly useful alternative when the motor current is below the 750 A requirement.

The 20G1AJC770JN0NNNNN is attractive when additional Heavy-Duty capacity is required.

The 770 A configuration has a higher Heavy-Duty power rating than the 750 A model, making it more appropriate for some demanding high-torque applications. 


32. Five Same-Brand Popular Models

The following models provide useful comparisons across different drive sizes and applications.

Model Product Series Voltage Class Current / Power Class Frame Typical Application
25B-D030N114 PowerFlex 525 480 VAC class 30 A class Compact General-purpose machines
25C-D030N114 PowerFlex 527 480 VAC class 30 A class Compact Networked machine control
20G1AGE053JA0NNNNN PowerFlex 755 600 VAC 53 A 6 Medium industrial motors
20G1AGC260JN0NNNNN PowerFlex 755 400 VAC 260 A 7 Large pumps and fans
20G1AND302JA0NNNNN PowerFlex 755 480 VAC 302 A 7 Large industrial motors

These models span a much broader application range than the 750 A Frame 8 unit.

The 25-series models are aimed at smaller machine-control applications.

The 20G-series PowerFlex 755 models are more appropriate for larger industrial motor systems.


33. Same-Brand Model Parameter Comparison

Model Voltage Current / Rating Frame Typical Enclosure Application Level
25B-D030N114 480 VAC class 30 A class Compact Industrial compact Small / medium machinery
25C-D030N114 480 VAC class 30 A class Compact Industrial compact Networked machinery
20G1AGE053JA0NNNNN 600 VAC 53 A 6 IP54 / Type 12 class Medium industrial motors
20G1AGC260JN0NNNNN 400 VAC 260 A 7 IP54 / Type 12 Large industrial motors
20G1AND302JA0NNNNN 480 VAC 302 A 7 Open industrial configuration Large motor control

These are not direct replacements for the 750 A model.

They are useful reference points when considering the wider product range.


34. Comparison with 20G1AJC650JN0NNNNN

The 650 A version is one of the closest alternatives.

Parameter 20G1AJC650JN0NNNNN 20G1AJC750JN0NNNNN
Voltage 400 VAC 400 VAC
Phase 3 Phase 3 Phase
Current 650 A 750 A
LD Power 400 kW 450 kW
ND Power 355 kW 400 kW
HD Power 315 kW 315 kW
Frame 8 8
Enclosure IP54 / Type 12 IP54 / Type 12
Cabinet Depth 800 mm 800 mm
Cooling Forced Air Forced Air
EtherNet/IP Embedded Embedded
Dynamic Braking None None
HIM Blank / No HIM Blank / No HIM
CM Jumper Installed Installed

The 750 A model provides greater Light-Duty and Normal-Duty capacity.

The Heavy-Duty rating remains 315 kW for both configurations.

Therefore, the 750 A model is particularly useful when additional current capacity is needed under Light-Duty or Normal-Duty operation.


35. Comparison with 20G1AJC770JN0NNNNN

The 770 A model is another very close alternative.

Parameter 20G1AJC750JN0NNNNN 20G1AJC770JN0NNNNN
Voltage 400 VAC 400 VAC
Phase 3 Phase 3 Phase
Current 750 A 770 A
LD Power 450 kW 450 kW
ND Power 400 kW 400 kW
HD Power 315 kW 355 kW
Frame 8 8
Enclosure IP54 / Type 12 IP54 / Type 12
Cooling Forced Air Forced Air
Cabinet Style 800 mm MCC 800 mm MCC
EtherNet/IP Embedded Embedded
Dynamic Braking None None
HIM Blank / No HIM Blank / No HIM
CM Jumper Installed Installed

The key difference is the Heavy-Duty capacity.

The 770 A version increases the Heavy-Duty power rating to 355 kW, while the 750 A version is rated at 315 kW Heavy Duty. 


36. Comparison with the Previous AN0 Model

The 20G1AJC750JN0NNNNN is the direct replacement for the older 20G1AJC750AN0NNNNN.

Parameter Previous Model Current Model
Catalog Number 20G1AJC750AN0NNNNN 20G1AJC750JN0NNNNN
Product Series PowerFlex 755 PowerFlex 755
Voltage 400 VAC 400 VAC
Phase 3 Phase 3 Phase
Current 750 A 750 A
LD Power 450 kW 450 kW
ND Power 400 kW 400 kW
HD Power 315 kW 315 kW
Frame 8 8
Cooling Forced Air Forced Air
Enclosure IP54 / Type 12 IP54 / Type 12
Cabinet Depth 800 mm 800 mm
EtherNet/IP Embedded Embedded
AC Precharge Yes Yes
DC Terminals None None
Filter Yes Yes
CM Jumper Installed Installed
Dynamic Braking None None
HIM Blank / No HIM Blank / No HIM
Lifecycle Discontinued Active
Replacement Relationship — Direct Replacement

The older AN0 model was discontinued on June 30, 2024, and the JN0 configuration was identified as its direct replacement. 

This makes the JN0 configuration particularly important for replacement projects involving older 750 A Frame 8 PowerFlex 755 systems.


37. Application Selection Guide

Application Suitability Primary Reason
Large Centrifugal Pump Excellent Variable-speed operation
Large Water Pump Excellent High-current motor control
Wastewater Pump Excellent Large motor / process regulation
Large Industrial Fan Excellent Variable-torque load
Large Blower Excellent High-power speed regulation
Mining Conveyor Excellent High-current controlled acceleration
Cement Conveyor Excellent Large motor applications
Material Handling Very Good Adjustable speed and torque
Process Pump Excellent Flow and pressure control
Industrial HVAC Fan Excellent Variable-torque operation
Large Mixer Good High-power motor control
Crusher Application Dependent Torque and overload analysis required
Compressor Application Dependent Load profile must be verified
Hoist Application Dependent Braking and safety requirements
High-Inertia Machine Application Dependent Regeneration and deceleration
Small Motor Not Recommended Drive is oversized

38. Engineering Advantages

The 20G1AJC750JN0NNNNN provides several advantages for large industrial projects.

High Current Capacity

The 750 A rating allows the drive to handle large motors that would exceed the capability of smaller drive frames.

Large Power Capacity

The 450 kW Light-Duty and 400 kW Normal-Duty ratings provide a wide operating range.

Industrial Protection

The IP54 / NEMA Type 12 enclosure provides a protected package for industrial installations.

Network Integration

Embedded EtherNet/IP allows direct integration with industrial automation systems.

Centralized Operation

The No-HIM configuration is suitable for systems where operators use a centralized HMI, SCADA system, or PLC.

Large-Plant Standardization

The PowerFlex 755 platform is available across multiple current and voltage ranges, allowing plants to standardize their drive technology.


39. Advantages for System Integrators

For system integrators, the model provides a useful combination of high-power electrical capability and network integration.

The embedded Ethernet interface can simplify the overall control architecture.

A centralized PLC can handle:

  • Drive commands.
  • Speed references.
  • Status.
  • Faults.
  • Alarms.
  • Process coordination.

This can reduce the amount of dedicated hardwired control required between the drive and automation system.

Standardizing multiple motor applications around the same PowerFlex family can also simplify:

  • PLC programming.
  • Commissioning.
  • Operator training.
  • Maintenance training.
  • Spare-parts management.
  • Troubleshooting.

40. Advantages for Plant Operators

The drive can improve operational flexibility.

Motor speed can be changed according to process requirements.

Acceleration can be controlled.

Deceleration can be controlled.

Drive faults can be monitored centrally.

Motor current can be monitored.

Operating status can be integrated into the plant control system.

For large process plants, these capabilities can make motor-control systems easier to supervise.


41. Advantages for Maintenance Personnel

The No-HIM configuration means that maintenance access is normally provided through the automation system or another supported service interface.

This can be useful in large centralized plants where maintenance personnel already use a common diagnostic environment.

The plant can monitor:

  • Drive faults.
  • Drive alarms.
  • Motor current.
  • Motor speed.
  • Drive state.
  • Network status.
  • Operating conditions.

For installations requiring a physical local display, the related JN4 configuration is a better fit.


42. Dimensions and Installation Space

The approximate mechanical planning values can be summarized as follows.

Mechanical Item Planning Value
Model 20G1AJC750JN0NNNNN
Frame 8
Width Approximately 600 mm class
Height Approximately 2,000–2,200 mm class
Depth Approximately 800 mm
Weight Approximately 500–700 kg
Enclosure IP54 / NEMA Type 12
Cabinet Style 800 mm Deep MCC
Cooling Forced Air
Installation Floor Standing

The 800 mm cabinet depth is a confirmed characteristic of this catalog configuration. 

The approximate width, height, and weight should be treated as engineering-planning estimates.

For a final project drawing, the actual dimensional drawing for the supplied unit should be used.


43. Transportation and Handling

Because the drive is in the approximate 500–700 kg class, transportation should be planned in advance.

The following should be confirmed:

  • Delivery vehicle capacity.
  • Forklift capacity.
  • Lifting equipment.
  • Building entrance dimensions.
  • Door height.
  • Corridor width.
  • Floor load capacity.
  • Installation position.
  • Cabinet access.
  • Service clearance.

The actual shipping weight should be verified before lifting.

The equipment should not be moved solely on the basis of the approximate planning weight given in this profile.


44. Electrical Room Planning

The electrical room should have adequate capacity for both the drive and its heat rejection.

The design should account for:

  • Cabinet footprint.
  • Cable entry.
  • Cable bending radius.
  • Front service access.
  • Cooling airflow.
  • Heat dissipation.
  • Adjacent equipment.
  • Maintenance clearance.
  • Emergency access.

Large drives should not be packed tightly together without considering thermal management.


45. Long-Term Reliability

Several factors have a direct influence on the service life of a large drive.

The most important are:

  • Ambient temperature.
  • Cooling-air quality.
  • Fan condition.
  • Electrical connection quality.
  • Motor cable installation.
  • Grounding.
  • Operating load.
  • Overload frequency.
  • Maintenance quality.

Keeping the cooling system clean and maintaining correct electrical connections are particularly important.

A high-power drive can operate reliably for many years when it is correctly sized, correctly installed, and properly maintained.


46. Recommended Maintenance Schedule

Maintenance Item Recommended Action
Cooling Fans Inspect regularly
Airflow Verify regularly
Cabinet Interior Inspect for contamination
Power Connections Inspect for looseness / overheating
Grounding Verify periodically
Motor Cable Inspect terminations
Ethernet Check communication integrity
Fault History Review periodically
Alarm History Review periodically
Operating Temperature Monitor
Enclosure Inspect condition
Control Wiring Inspect periodically

Actual maintenance intervals should be determined by the plant’s operating environment and maintenance program.

Dusty, humid, corrosive, or high-temperature environments generally require more frequent inspection.


47. Product Positioning

The 20G1AJC750JN0NNNNN should be regarded as a large industrial variable-frequency drive, not a compact machine-level VFD.

Its main characteristics are:

  • 750 A current capacity.
  • 450 kW Light-Duty rating.
  • 400 kW Normal-Duty rating.
  • 315 kW Heavy-Duty rating.
  • 400 VAC three-phase input.
  • Frame 8.
  • IP54 / NEMA Type 12 enclosure.
  • 800 mm MCC-style cabinet.
  • Forced-air cooling.
  • Embedded EtherNet/IP.
  • No local HIM.
  • No dynamic braking.

These characteristics position it well for large centralized industrial motor-control applications.


48. Key Specifications at a Glance

Key Item Specification
Model 20G1AJC750JN0NNNNN
Brand Allen-Bradley
Series PowerFlex 755
Product Air-Cooled AC Drive
Voltage 400 VAC
Phase 3 Phase
Current 750 A
LD Rating 450 kW
ND Rating 400 kW
HD Rating 315 kW
Frame 8
Cooling Forced Air
Enclosure IP54 / NEMA Type 12
Cabinet 800 mm Deep MCC Style
Communication Embedded EtherNet/IP
Input AC with Precharge
DC Terminals None
Filter Yes
CM Jumper Installed
Dynamic Braking None
HIM Blank / No HIM
Approx. Dimensions 600 × 2,000–2,200 × 800 mm
Approx. Weight 500–700 kg
Main Application Large Industrial Motors
Product Status Active

49. Overall Assessment

The Allen-Bradley 20G1AJC750JN0NNNNN PowerFlex 755 AC Drive is a high-capacity industrial AC drive designed for large 400 VAC three-phase motor systems.

Its 750 A current rating and 450 kW Light-Duty / 400 kW Normal-Duty / 315 kW Heavy-Duty power ratings make it suitable for large industrial machinery.

The Frame 8 architecture and 800 mm deep MCC-style construction place it firmly in the centralized industrial electrical-equipment category.

The IP54 / NEMA Type 12 enclosure provides a protected industrial package, while forced-air cooling handles the thermal requirements associated with the high-power drive section.

The embedded EtherNet/IP interface is one of the most important automation features.

It allows the drive to communicate directly with the plant control system, making the model suitable for large multi-drive installations.

The Blank / No HIM configuration is particularly appropriate where the plant uses centralized control through a PLC, HMI, SCADA, or industrial Ethernet system.

The absence of a local HIM is less suitable for applications where operators need frequent physical access to the drive.

In such cases, a related JN4 configuration can be considered.

The drive is also configured without dynamic braking.

This is suitable for many pumps, fans, and blowers, but applications involving high inertia, frequent stopping, or substantial regenerative energy should receive a dedicated braking analysis.

From a mechanical standpoint, this is a large piece of industrial equipment.

The approximate planning envelope of 600 mm width × 2,000–2,200 mm height × 800 mm depth, combined with an approximate 500–700 kg weight, means that transportation, lifting, floor loading, cooling, and maintenance access should be considered during the initial engineering phase.

For large water pumps, wastewater systems, industrial fans, blowers, mining conveyors, cement equipment, material handling, process pumps, and other large motor applications, the 20G1AJC750JN0NNNNN provides a strong combination of electrical capacity and industrial automation integration.

The model is also important for replacement work because it directly replaces the earlier 20G1AJC750AN0NNNNN configuration.

For new projects, the JN0 configuration is the current model to consider when the application requires the same basic 750 A, 400 VAC, Frame 8, No-HIM configuration.

When selecting between the closely related models, the most important distinctions are current and duty rating.

The 650 A model is suitable when the motor current requirement is lower.

The 750 A model provides higher Light-Duty and Normal-Duty capacity.

The 770 A model becomes particularly attractive where additional Heavy-Duty capacity is required.

In practical engineering terms, the 20G1AJC750JN0NNNNN can be summarized as a 750 A high-power, 400 VAC, Frame 8 PowerFlex 755 industrial AC drive with embedded EtherNet/IP, IP54 / NEMA Type 12 protection, forced-air cooling, 800 mm MCC-style construction, AC input precharge, and no local HIM.

It is best suited to large industrial motor systems where centralized automation, high current capacity, variable-speed operation, and robust industrial construction are required.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501