20G11TE460AN0NNNNN — Detailed Product Specifications, Introduction, Applications, Advantages and Related Models
The 20G11TE460AN0NNNNN is a high-power AC variable frequency drive from the PowerFlex 755 series. It is designed for large three-phase industrial motors and demanding applications where high current capacity, adjustable speed, controlled acceleration, process control, and industrial communication are required.
This model belongs to the 600 VAC class and has a 460 A Light Duty output rating. Its corresponding motor ratings are approximately 500 HP for Light Duty, 500 HP for Normal Duty, and 400 HP for Heavy Duty.
The drive uses an air-cooled, open-type Frame 9 configuration and is intended for installation in a suitable industrial electrical cabinet or equipment enclosure. It is a substantially larger drive than compact variable frequency drives and is intended for large pumps, conveyors, fans, blowers, process machinery, mills, crushers, and other high-power industrial equipment.
The model is also an older catalog configuration. For replacement planning, the corresponding 20G11TE460JN0NNNNN configuration is the newer direct-replacement version to evaluate.
1. Basic Product Information
| Parameter |
Specification |
| Brand |
Allen-Bradley |
| Product Series |
PowerFlex 755 |
| Product Family |
PowerFlex 750-Series AC Drives |
| Model |
20G11TE460AN0NNNNN |
| Product Type |
High-Power AC Variable Frequency Drive |
| Drive Type |
Adjustable Frequency AC Drive |
| Voltage Class |
600 VAC |
| Input Voltage Range |
540–660 VAC class |
| Input Phase |
3-Phase |
| Output Phase |
3-Phase |
| Light Duty Output Current |
460 A |
| Normal Duty Output Current |
460 A |
| Heavy Duty Output Current |
395 A |
| Light Duty Motor Rating |
500 HP |
| Normal Duty Motor Rating |
500 HP |
| Heavy Duty Motor Rating |
400 HP |
| Frame |
Frame 9 |
| Cooling |
Forced Air / Air Cooled |
| Construction |
Open Type |
| Input Configuration |
AC Input with Precharge |
| DC Terminals |
Yes |
| Communication |
Embedded EtherNet/IP |
| EMC Configuration |
Filtered |
| CM Configuration |
Jumper Installed |
| Dynamic Braking |
None |
| HIM |
Blank / No HIM |
| Output Frequency |
Up to approximately 400 Hz class |
| Installation |
Industrial cabinet / protected enclosure |
| Approx. Dimensions |
Approximately 950 × 800 × 1370 mm class, installation-dependent |
| Approx. Weight |
Approximately 600–700 kg class, configuration-dependent |
The dimensions and weight should be regarded as engineering reference values rather than fixed shipping specifications. The actual Frame 9 arrangement, cabinet construction, power connections, mounting hardware, cooling arrangement, and auxiliary equipment can change the final dimensions and weight.
2. Brand and Series
| Category |
Information |
| Brand |
Allen-Bradley |
| Series |
PowerFlex 755 |
| Product Family |
PowerFlex 750-Series |
| Product Category |
Industrial AC Drive |
| Drive Class |
High Power |
| Voltage Category |
600 VAC |
| Frame Category |
Frame 9 |
| Primary Function |
Large AC motor speed and torque control |
The PowerFlex 755 series is intended for industrial applications requiring considerably more capability than a compact general-purpose inverter.
It is particularly appropriate for large motors and machinery where the drive must provide controlled speed, acceleration, deceleration, monitoring, and integration with an industrial control system.
3. Product Model Identification
The catalog number 20G11TE460AN0NNNNN contains several configuration identifiers.
| Model Section |
General Description |
| 20G |
PowerFlex 755 family |
| 11 |
Drive configuration |
| TE |
600 VAC, three-phase configuration |
| 460 |
460 A current class |
| A |
Earlier configuration |
| N0NNNNN |
Additional configuration positions |
The 460 portion is particularly important because it identifies the current class of the drive.
The TE designation identifies the 600 VAC class.
The complete catalog number should be used when identifying a replacement because two drives with similar current and horsepower ratings may have different communication, braking, filtering, feedback, enclosure, or control configurations.
4. Detailed Electrical Specifications
| Electrical Parameter |
Specification |
| Input Voltage Class |
600 VAC |
| Input Voltage Range |
540–660 VAC class |
| Input Phase |
Three-phase |
| Output Phase |
Three-phase |
| Light Duty Current |
460 A |
| Normal Duty Current |
460 A |
| Heavy Duty Current |
395 A |
| Light Duty Horsepower |
500 HP |
| Normal Duty Horsepower |
500 HP |
| Heavy Duty Horsepower |
400 HP |
| Approx. Light Duty Power |
373 kW |
| Approx. Normal Duty Power |
373 kW |
| Approx. Heavy Duty Power |
298 kW |
| DC Bus Voltage Class |
Approximately 810 VDC |
| Output Frequency |
0–400 Hz class |
| Cooling |
Forced Air |
| Input Type |
AC with precharge |
| DC Terminals |
Included |
| EMC Filter |
Filtered |
| CM Jumper |
Installed |
| Dynamic Braking |
None |
| Communication |
Embedded EtherNet/IP |
| Local HIM |
Not included |
| Frame |
Frame 9 |
| Construction |
Open Type |
The 460 A configuration is notable because its Light Duty and Normal Duty ratings are both approximately 500 HP, while its Heavy Duty rating is approximately 400 HP.
That difference is important when the drive is used on machines with high overload or high starting-torque requirements.
5. Duty Rating Explanation
The three duty classifications should not be treated as interchangeable.
Light Duty
The Light Duty rating is approximately 460 A / 500 HP.
This rating is more appropriate for applications where the motor load is relatively moderate and the overload requirements are less demanding.
Typical examples can include certain large fans, centrifugal pumps, and other applications where the load characteristics are comparatively smooth.
Normal Duty
The Normal Duty rating is also approximately 460 A / 500 HP.
This makes the model particularly attractive for large industrial applications where the motor continuously operates around the 500 HP class but does not require the more severe overload capability associated with Heavy Duty operation.
Heavy Duty
The Heavy Duty rating is approximately 395 A / 400 HP.
This lower rating reflects the additional thermal and electrical demands associated with heavier overload conditions.
Applications such as crushers, high-inertia machinery, heavily loaded conveyors, and certain process machines may need to be evaluated using the Heavy Duty rating rather than the maximum horsepower rating.
6. Product Introduction
The 20G11TE460AN0NNNNN is designed to control the speed and operating behavior of large three-phase AC motors.
A conventional motor starter generally provides basic starting and stopping.
A variable frequency drive provides much more control.
The drive can adjust the frequency and voltage supplied to the motor, allowing the motor to operate at different speeds.
This can make a major difference in large industrial machinery.
For example, a large conveyor does not necessarily need to start at full speed. A pump may not need to operate continuously at maximum speed. A fan may require different airflow during different stages of production.
By controlling motor speed, the drive allows the machine to respond more closely to actual process requirements.
7. Operating Principle
The drive receives three-phase AC power from the electrical system.
The internal power electronics process the incoming power and generate a controlled variable-frequency output for the motor.
The output frequency determines the commanded motor speed.
The drive can also regulate voltage, current, acceleration, deceleration, and other motor-control parameters according to the configured operating mode.
The result is a controlled motor system capable of operating over a range of speeds rather than being restricted to the fixed speed associated with the electrical supply frequency.
8. Main Product Functions
8.1 Variable-Speed Control
The primary purpose of the drive is to control motor speed.
This allows the motor to operate according to process requirements rather than continuously operating at a fixed speed.
For large industrial systems, this can improve process flexibility and can reduce unnecessary operation at maximum speed.
8.2 Controlled Acceleration
Large motors and machines can have substantial inertia.
Starting them abruptly can produce high electrical and mechanical stresses.
The drive can provide a controlled acceleration profile.
This allows the machine to move from zero speed toward its operating speed in a more controlled manner.
8.3 Controlled Deceleration
The drive can also control the rate at which the motor slows down.
This can be particularly useful for:
- Large fans
- Large conveyors
- High-inertia rotating machinery
- Process equipment
- Large pumps
- Material-handling systems
8.4 Industrial Communication
Embedded EtherNet/IP allows the drive to be integrated into an industrial automation network.
The drive can exchange information with the control system, including operating commands, status information, speed references, and fault information.
This makes the drive suitable for centralized machine control and plant-level automation.
9. Product Applications
9.1 Large Conveyors
Large conveyors can require substantial motor power, especially when transporting heavy material over long distances.
The drive can provide controlled acceleration and speed regulation.
This can help reduce mechanical shock to:
- Conveyor belts
- Gearboxes
- Couplings
- Shafts
- Rollers
- Mechanical structures
The application is particularly relevant to mining, bulk material handling, aggregate processing, cement production, ports, and heavy manufacturing.
9.2 Large Pumps
Large pumps can benefit from variable-speed control when the required flow or pressure changes during operation.
Instead of continuously running the motor at maximum speed, the drive can adjust speed according to the process.
Applications include:
- Water treatment
- Industrial cooling
- Process water
- Circulation systems
- Industrial pumping
- Utility systems
- Large-scale fluid handling
9.3 Large Fans and Blowers
Large fans and blowers can consume substantial motor power.
Variable-speed operation allows airflow to be adjusted according to actual requirements.
This is useful for:
- Industrial ventilation
- Furnace systems
- Dust collection
- Process exhaust
- Cooling systems
- Mining ventilation
- Large air-handling systems
9.4 Crushers
Crushers can produce highly variable mechanical loads.
Starting a large crusher can require significant torque.
The drive can provide controlled acceleration and help manage the motor according to the machine’s operating requirements.
For crusher applications, the Heavy Duty rating should be considered carefully.
9.5 Mills
Large mills can require hundreds of horsepower.
The PowerFlex 755 platform is suitable for applications where the motor requires variable-speed control and the machine must be integrated into a broader production system.
9.6 Mixers and Agitators
Large mixers can experience high starting torque, especially when the material being mixed is dense or viscous.
The drive allows the motor to accelerate under controlled conditions and operate at a selected speed.
9.7 Material-Handling Equipment
The high current capacity makes the model suitable for large material-handling machinery.
Possible applications include:
- Bulk handling
- Large conveyors
- Processing equipment
- Industrial transport systems
- Heavy production machinery
9.8 Process Machinery
The drive can also be used for large process machines where adjustable speed is required.
Examples include:
- Large rotating equipment
- Process fans
- Large pumps
- Mixers
- Extrusion equipment
- Industrial production machinery
10. Major Product Advantages
10.1 High-Power Capacity
The model provides approximately 500 HP Light Duty and 500 HP Normal Duty capacity.
This makes it suitable for large industrial motors that cannot be handled by compact drive families.
10.2 High Current Rating
The 460 A output rating provides substantial electrical capacity.
This is one of the main reasons to select this model over smaller PowerFlex configurations.
10.3 600 VAC Class
The 600 VAC class is appropriate for high-power industrial electrical systems.
For large motors, higher-voltage systems can reduce current compared with equivalent lower-voltage systems.
This can have implications for:
- Cable selection
- Motor selection
- Switchgear
- Transformers
- Electrical distribution
- Protection equipment
10.4 Industrial Network Integration
Embedded EtherNet/IP allows the drive to become part of a networked control architecture.
This is useful for factories where motor control, machine control, diagnostics, and production monitoring need to work together.
10.5 Large-Frame Construction
The Frame 9 design is intended for high-power applications.
It provides a substantially larger power section than compact variable frequency drives.
10.6 Forced-Air Cooling
High-power electronic equipment generates considerable heat.
Forced-air cooling provides the necessary thermal management.
This makes proper cabinet airflow an important part of the installation.
10.7 Flexible Industrial Application
The same drive platform can be applied to many different machine types.
This is useful for industrial facilities that want to standardize their motor-control architecture across multiple applications.
11. Mechanical Specifications
| Mechanical Parameter |
Specification |
| Frame |
Frame 9 |
| Construction |
Open Type |
| Cooling |
Forced Air |
| Approx. Width |
Approximately 800 mm class |
| Approx. Height |
Approximately 950 mm class |
| Approx. Depth |
Approximately 1370 mm class |
| Approx. Overall Dimensions |
Approximately 950 × 800 × 1370 mm class |
| Approx. Weight |
Approximately 600–700 kg class |
| Cabinet Installation |
Required / Recommended |
| Ventilation |
Required |
| Maintenance Clearance |
Required |
| Power Cable Space |
Required |
| Control Cable Space |
Required |
For this size of industrial drive, physical dimensions can vary depending on the installation arrangement.
The complete electrical assembly can include mounting structures, power distribution components, cooling equipment, wiring compartments, and other accessories.
Therefore, the dimensions above should be used for preliminary planning rather than treated as an exact shipping measurement.
12. Why Dimensions and Weight Matter
A drive in this power class cannot be treated like a small panel-mounted inverter.
The mechanical installation requires careful planning.
The cabinet designer needs to consider:
- Available floor space
- Cabinet width
- Cabinet depth
- Cabinet height
- Door clearance
- Cable entry
- Cable bending radius
- Ventilation
- Heat dissipation
- Service access
- Lifting equipment
- Mounting structure
The approximate 600–700 kg weight class also means that transportation and installation require appropriate handling equipment.
13. Cooling and Thermal Management
The drive uses forced-air cooling.
Because the drive can operate at hundreds of amps, thermal management is an important engineering consideration.
The cabinet should provide adequate airflow.
Hot exhaust air should not be allowed to circulate back into the cooling-air intake.
The installation should also consider ambient temperature, dust, altitude, ventilation filters, and maintenance intervals.
A clean and properly ventilated installation can help maintain stable operating temperatures and reduce unnecessary thermal stress.
14. Industrial Communication
The embedded EtherNet/IP capability is an important feature of this model.
In a modern automated plant, the drive can be integrated into the machine-control system.
The control system can exchange information such as:
- Run command
- Stop command
- Speed reference
- Actual speed
- Drive status
- Current
- Fault condition
- Alarm information
- Operating state
This allows the drive to operate as an integrated component of the machine rather than as an independent motor controller.
15. Typical Industrial Applications
| Application |
Suitability |
Main Benefit |
| Large Conveyor |
Excellent |
Controlled acceleration and speed |
| Large Pump |
Excellent |
Variable flow and pressure control |
| Large Fan |
Excellent |
Adjustable airflow |
| Large Blower |
Excellent |
Speed regulation |
| Crusher |
Good |
High-power motor control |
| Mill |
Good |
Controlled large motor operation |
| Mixer |
Good |
Controlled starting torque |
| Material Handling |
Excellent |
High current capacity |
| Process Machinery |
Excellent |
Networked variable-speed control |
| Industrial Cooling |
Excellent |
Variable-speed fan/pump operation |
| Small Machine |
Poor |
Excessive capacity and physical size |
16. Five Recommended Models from the Same Series
The following models are closely related PowerFlex 755 configurations and are useful for comparison.
| Product Series |
Model |
Voltage |
Current Class |
Light Duty |
Normal Duty |
Heavy Duty |
Frame |
Dimensions |
Weight (kg) |
| PowerFlex 755 |
20G11TE355AN0NNNNN |
600 VAC |
355 A |
400 HP |
350 HP |
300 HP |
8 |
Approx. 900 × 600 × 1260 mm class |
Approx. 400–500 kg |
| PowerFlex 755 |
20G11TE395AN0NNNNN |
600 VAC |
395 A |
450 HP |
400 HP |
350 HP |
8 |
Approx. 900 × 700 × 1260 mm class |
Approx. 450–500 kg |
| PowerFlex 755 |
20G11TE435AN0NNNNN |
600 VAC |
435 A |
500 HP |
450 HP |
350 HP |
8 |
Approx. 900 × 760 × 1260 mm class |
Approx. 450–550 kg |
| PowerFlex 755 |
20G11TE460JN0NNNNN |
600 VAC |
460 A |
500 HP |
500 HP |
400 HP |
9 |
Approx. 950 × 800 × 1370 mm class |
Approx. 600–700 kg |
| PowerFlex 755 |
20G11TE510AN0NNNNN |
600 VAC |
510 A |
550 HP |
500 HP |
450 HP |
9 |
Approx. 1100 × 800 × 1470 mm class |
Approx. 650–750 kg |
The 20G11TE460JN0NNNNN is especially important because it is the newer configuration corresponding to the 20G11TE460AN0NNNNN.
The lower-current models can be considered when the motor’s actual current requirement is below the 460 A class.
The 510 A configuration can be considered when additional current capacity is required.
17. Same-Series Model Comparison
| Model |
Current |
LD Rating |
ND Rating |
HD Rating |
Relative Position |
| 20G11TE355AN0NNNNN |
355 A |
400 HP |
350 HP |
300 HP |
Lower capacity |
| 20G11TE395AN0NNNNN |
395 A |
450 HP |
400 HP |
350 HP |
Lower capacity |
| 20G11TE435AN0NNNNN |
435 A |
500 HP |
450 HP |
350 HP |
Lower capacity |
| 20G11TE460AN0NNNNN |
460 A |
500 HP |
500 HP |
400 HP |
Target model |
| 20G11TE510AN0NNNNN |
510 A |
550 HP |
500 HP |
450 HP |
Higher capacity |
This comparison shows that the 460 A model occupies an important position in the 600 VAC PowerFlex 755 range.
It provides more Normal Duty capacity than the 435 A configuration while maintaining a 500 HP class rating.
18. Five Popular Models from the Same Brand
The following models represent different product ranges and power levels.
| Product Series |
Model |
Voltage Class |
Approx. Power Class |
Typical Application |
Dimensions |
Weight (kg) |
| PowerFlex 525 |
25B-D010N104 |
480 VAC class |
Approx. 4 HP |
Small machinery, pumps, conveyors |
Approx. 180 × 90 × 150 mm |
Approx. 2–3 kg |
| PowerFlex 525 |
25B-D017N104 |
480 VAC class |
Approx. 7.5 HP |
General industrial machinery |
Approx. 220 × 110 × 170 mm |
Approx. 3–4 kg |
| PowerFlex 523 |
25A-D030N104 |
480 VAC class |
Approx. 15 HP |
Pumps, fans, conveyors |
Approx. 250 × 130 × 190 mm |
Approx. 4–6 kg |
| PowerFlex 753 |
20F11NC022JA0NNNNN |
480 VAC class |
High-power industrial |
Process equipment, conveyors, pumps |
Configuration dependent |
Configuration dependent |
| PowerFlex 755 |
20G11TE460JN0NNNNN |
600 VAC |
460 A / 500 HP ND |
Large industrial machinery |
Approx. 950 × 800 × 1370 mm class |
Approx. 600–700 kg |
These products cover very different application ranges.
The compact products are intended for much smaller motors.
The PowerFlex 753 and PowerFlex 755 platforms are intended for more demanding industrial applications.
19. Compact Drives Compared with the 20G11TE460AN0NNNNN
| Characteristic |
Compact Drive |
20G11TE460AN0NNNNN |
| Motor Size |
Small to medium |
Large |
| Output Current |
Low/medium |
460 A |
| Normal Duty Power |
Low/medium |
500 HP |
| Voltage Class |
Usually lower |
600 VAC |
| Installation |
Compact panel |
Large industrial cabinet |
| Cooling |
Compact |
Forced air |
| Industrial Network |
Model dependent |
Embedded EtherNet/IP |
| Large Conveyor |
Limited |
Suitable |
| Large Pump |
Limited |
Suitable |
| Large Fan |
Limited |
Suitable |
| Crusher |
Generally limited |
Suitable within rating |
| Mill |
Generally limited |
Suitable within rating |
| Heavy Process Equipment |
Limited |
Suitable |
20. Product Advantages for Large Industrial Systems
High Motor Capacity
The ability to operate at approximately 500 HP Normal Duty makes this model appropriate for large motor-driven equipment.
High Current Capability
The 460 A current class provides enough electrical capacity for substantial industrial motors.
Industrial Voltage Class
The 600 VAC configuration makes it suitable for high-power motor systems.
Network Integration
Embedded EtherNet/IP makes it easier to incorporate the drive into an automated production system.
Controlled Motor Operation
Variable-speed control allows the machine to operate according to actual production requirements.
Large-Scale Mechanical Compatibility
The Frame 9 construction is designed around large industrial equipment rather than compact machinery.
Flexible Application Range
The same general drive platform can be used for pumps, fans, conveyors, mills, crushers, mixers, and process machinery.
21. Energy and Process Benefits
Variable-speed operation can provide important process benefits.
A motor does not always need to run at full speed.
For a pump, reducing motor speed can reduce flow and pressure.
For a fan, speed can be adjusted according to the required airflow.
For a conveyor, speed can be matched to material flow.
For a process machine, speed can be coordinated with upstream and downstream production equipment.
The actual energy savings depend strongly on the load type and operating conditions, so energy performance should be evaluated against the specific machine rather than assumed solely from the use of a VFD.
22. Maintenance Considerations
A high-power drive requires appropriate maintenance practices.
Important areas include:
- Cooling fans
- Air passages
- Cabinet ventilation
- Electrical connections
- Power terminals
- Control wiring
- Network connections
- Environmental contamination
- Temperature
- Fault history
- Motor cable condition
Dust accumulation around the cooling system can reduce airflow.
Poor ventilation can increase internal temperature.
Loose power connections can create electrical and thermal problems.
For these reasons, routine inspection is particularly important on large industrial drives.
23. Installation Environment
The open-type construction means the drive should normally be integrated into an appropriate protected electrical installation.
The installation environment should be evaluated for:
- Dust
- Moisture
- Temperature
- Corrosive materials
- Altitude
- Vibration
- Air quality
- Electrical interference
The cabinet should be designed so that the drive’s environmental requirements are maintained during normal operation.
24. Replacement Considerations
The original 20G11TE460AN0NNNNN is an older configuration.
For replacement purposes, the corresponding 20G11TE460JN0NNNNN is the important newer model to evaluate.
The electrical class remains closely related:
| Parameter |
20G11TE460AN0NNNNN |
20G11TE460JN0NNNNN |
| Series |
PowerFlex 755 |
PowerFlex 755 |
| Voltage |
600 VAC |
600 VAC |
| Current Class |
460 A |
460 A |
| Light Duty |
500 HP |
500 HP |
| Normal Duty |
500 HP |
500 HP |
| Heavy Duty |
400 HP |
400 HP |
| Frame |
9 |
9 |
| Cooling |
Forced Air |
Forced Air |
| Construction |
Open Type |
Open Type |
| Communication |
Embedded EtherNet/IP |
Embedded EtherNet/IP |
| EMC |
Filtered |
Filtered |
| CM Configuration |
Legacy configuration |
Updated configuration |
| Replacement Relationship |
Original configuration |
Newer replacement configuration |
When replacing the older model, it is still necessary to verify control wiring, parameters, feedback, network settings, cabinet dimensions, power connections, and application-specific options.
25. Recommended Selection by Application
| Application |
Recommended Drive Consideration |
| 300–350 HP industrial motor |
Consider lower-current PowerFlex 755 configuration |
| 400 HP Normal Duty motor |
20G11TE395 class or larger |
| 450 HP Normal Duty motor |
20G11TE435 class or larger |
| 500 HP Normal Duty motor |
20G11TE460 class |
| 500 HP Heavy Duty motor |
Consider a higher-rated configuration |
| Large centrifugal pump |
460 A class can be appropriate depending on motor current |
| Large fan |
460 A class can be appropriate depending on motor current |
| Heavy conveyor |
Check Heavy Duty rating carefully |
| Crusher |
Check Heavy Duty current and overload requirements |
| Mill |
Check actual motor current and duty cycle |
| Large process machine |
Check motor current, inertia and overload |
26. Important Selection Factors
Before selecting the drive for a particular motor, the following information should be checked.
| Selection Factor |
Importance |
| Motor Voltage |
Critical |
| Motor Full-Load Current |
Critical |
| Motor Horsepower |
Important |
| Motor Frequency |
Important |
| Duty Cycle |
Critical |
| Starting Torque |
Critical for demanding loads |
| Overload Requirement |
Critical |
| Acceleration Time |
Important |
| Deceleration Time |
Important |
| Load Inertia |
Important |
| Ambient Temperature |
Important |
| Altitude |
Important |
| Motor Cable Length |
Important |
| Braking Requirement |
Application dependent |
| Feedback Requirement |
Application dependent |
| Communication |
Important |
| Cabinet Space |
Critical |
| Cooling |
Critical |
| Maintenance Access |
Important |
27. Key Technical Advantages at a Glance
| Feature |
Advantage |
| 460 A Output |
High-current motor control |
| 500 HP Light Duty |
Very high power capability |
| 500 HP Normal Duty |
Strong continuous-duty capacity |
| 400 HP Heavy Duty |
Suitable for demanding applications within rating |
| 600 VAC |
High-power industrial electrical compatibility |
| Frame 9 |
Large industrial drive architecture |
| Forced Air |
Effective cooling for high-power electronics |
| Embedded EtherNet/IP |
Networked industrial control |
| DC Terminals |
Supports DC-bus-related applications |
| Filtered EMC |
Helps manage electromagnetic compatibility |
| Open Type |
Flexible cabinet integration |
| No HIM |
Suitable for externally controlled systems |
28. Product Application Advantages
Conveyors
Controlled acceleration can reduce mechanical shock and provide adjustable material-handling speed.
Pumps
Variable-speed operation allows pump output to be adjusted according to process requirements.
Fans
Fan speed can be adjusted according to airflow demand.
Blowers
The drive provides large-motor speed control for industrial air-moving systems.
Mills
The high-power rating allows use with large mill motors within the applicable duty range.
Crushers
The high current capacity supports large motors, although Heavy Duty requirements must be checked carefully.
Mixers
Controlled acceleration and speed regulation can be useful when starting under heavy material loads.
Process Machinery
Networked motor control allows the drive to be integrated into a larger automated production system.
29. Overall Product Evaluation
The 20G11TE460AN0NNNNN is a high-power industrial AC drive intended for applications around the 500 HP class.
Its combination of 600 VAC operation, 460 A current capacity, 500 HP Light Duty rating, 500 HP Normal Duty rating, 400 HP Heavy Duty rating, Frame 9 construction, forced-air cooling, and embedded EtherNet/IP makes it suitable for large industrial equipment.
Compared with the 435 A PowerFlex 755 configuration, the 460 A model provides a higher Normal Duty capacity.
This makes it particularly useful when a 450 HP-class drive is close to its operating limit and additional current capacity is desirable.
At the same time, the drive is physically large and heavy.
It should therefore be selected for applications that genuinely require this level of capacity rather than simply choosing it because a smaller drive is available.
30. Final Technical Specification Table
| Parameter |
20G11TE460AN0NNNNN |
| Brand |
Allen-Bradley |
| Series |
PowerFlex 755 |
| Product Type |
High-Power AC Variable Frequency Drive |
| Voltage Class |
600 VAC |
| Input Voltage Range |
540–660 VAC class |
| Phase |
Three-phase |
| Light Duty Current |
460 A |
| Normal Duty Current |
460 A |
| Heavy Duty Current |
395 A |
| Light Duty Rating |
500 HP |
| Normal Duty Rating |
500 HP |
| Heavy Duty Rating |
400 HP |
| Light Duty Power |
Approx. 373 kW |
| Normal Duty Power |
Approx. 373 kW |
| Heavy Duty Power |
Approx. 298 kW |
| Frame |
Frame 9 |
| Cooling |
Forced Air |
| Construction |
Open Type |
| Input |
AC Input with Precharge |
| DC Terminals |
Yes |
| Communication |
Embedded EtherNet/IP |
| EMC Configuration |
Filtered |
| CM Configuration |
Jumper Installed |
| Dynamic Braking |
None |
| HIM |
Blank / No HIM |
| Output Frequency |
0–400 Hz class |
| Approx. Width |
800 mm class |
| Approx. Height |
950 mm class |
| Approx. Depth |
1370 mm class |
| Approx. Dimensions |
950 × 800 × 1370 mm class |
| Approx. Weight |
600–700 kg class |
| Typical Application |
Large industrial motor control |
| Main Applications |
Conveyors, pumps, fans, blowers, mills, crushers, mixers |
| Related Lower Model |
20G11TE435AN0NNNNN |
| Related Higher Model |
20G11TE510AN0NNNNN |
| Replacement Configuration |
20G11TE460JN0NNNNN |
31. Conclusion
The 20G11TE460AN0NNNNN is a large-frame, high-power PowerFlex 755 AC variable frequency drive designed for large three-phase industrial motors.
Its 600 VAC voltage class, 460 A current rating, and 500 HP Normal Duty capacity make it particularly suitable for large industrial motor applications.
The drive is a strong choice for large conveyors, industrial pumps, fans, blowers, crushers, mills, mixers, material-handling equipment, and process machinery where variable-speed control and industrial automation integration are required.
One of its most important advantages is the combination of high electrical capacity and networked industrial control.
The embedded EtherNet/IP capability allows the drive to communicate with the wider automation system, while the high-current power section provides the capacity needed for large motors.
For applications below the 460 A class, models such as 20G11TE355AN0NNNNN, 20G11TE395AN0NNNNN, and 20G11TE435AN0NNNNN are useful same-series alternatives.
For applications requiring additional capacity, 20G11TE510AN0NNNNN is the logical higher-current comparison.
For replacement work, 20G11TE460JN0NNNNN is the key newer configuration to consider for the original 20G11TE460AN0NNNNN.
The most important point when applying this drive is to select it according to the actual motor full-load current, duty cycle, overload requirements, starting torque, ambient conditions, and installation requirements, rather than relying on horsepower alone.
Note: The dimensions and weight in this document are intended as reference values for preliminary product evaluation. For final cabinet design, transportation, lifting, installation, or replacement work, the exact mechanical configuration should be verified because Frame 9 installations can vary according to the complete equipment arrangement.