The 20G11BC1K2JN4NNNNN is a high-power Allen-Bradley PowerFlex 755 AC Drive designed for large industrial motor-control applications.
It belongs to the PowerFlex 755 series and the 755 AC Packaged Drive family. This configuration is an air-cooled, high-current drive intended for large three-phase AC motors used in demanding industrial processes.
The drive is rated for the 400 V AC three-phase class, with a published output current of 1,175 A. Its principal published power ratings are 710 kW Normal Duty and 560 kW Heavy Duty. The corresponding Light Duty rating is approximately 800 kW for this rating class. The unit is a Frame 9 design with a 600 mm deep MCC-style enclosure.
One of the most important characteristics of the JN4 configuration is its local operator-interface arrangement. It is intended for applications where a local enhanced operator interface is required, while the overall drive remains part of a larger industrial automation system.
The product is currently listed as Active.
| Item | Specification |
|---|---|
| Model | 20G11BC1K2JN4NNNNN |
| Brand | Allen-Bradley |
| Product family | PowerFlex |
| Series | PowerFlex 755 |
| Product category | AC Variable Frequency Drive |
| Sub-family | 755 AC Packaged Drive |
| Drive type | Air-Cooled AC Drive |
| Application class | High-power industrial motor control |
| Frame | Frame 9 |
| Input voltage | 400 V AC |
| Input phase | 3 phase |
| Output current | 1,175 A |
| Normal Duty | 710 kW |
| Heavy Duty | 560 kW |
| Light Duty | Approximately 800 kW |
| Enclosure | IP20 / Type 1 |
| Cabinet style | 600 mm Deep MCC Style |
| Cooling | Air cooled |
| Input configuration | AC Input with Precharge |
| DC terminals | Included in the applicable input configuration |
| EMC/filter configuration | Filtered |
| CM jumper | Installed |
| Dynamic braking | None |
| Local operator interface | Enhanced LCD / Full Numeric HIM |
| Communication | Embedded EtherNet/IP |
| Product status | Active |
| Parameter | Specification |
|---|---|
| Model | 20G11BC1K2JN4NNNNN |
| Brand | Allen-Bradley |
| Series | PowerFlex 755 |
| Product family | PowerFlex 750-Series |
| Product type | PowerFlex 755 AC Packaged Drive |
| Construction | Air cooled |
| Input voltage | 400 VAC class |
| Input phase | 3 phase |
| Input frequency | 50/60 Hz class |
| Output phase | 3 phase |
| Rated output current | 1,175 A |
| Light Duty power | Approximately 800 kW |
| Normal Duty power | 710 kW |
| Heavy Duty power | 560 kW |
| Frame size | Frame 9 |
| Enclosure | IP20 / Type 1 |
| Cabinet style | 600 mm Deep MCC Style |
| Cooling | Forced air / air cooled |
| Input type | AC Input with Precharge |
| EMC filtering | Filtered |
| CM configuration | Jumper Installed |
| Dynamic braking | None |
| Local operator interface | Enhanced LCD / Full Numeric HIM |
| Communication | Embedded EtherNet/IP |
| Application | Large industrial motor control |
| Depth | 600 mm |
| Overall dimensions | Frame 9 MCC-style configuration; exact height and width depend on the applicable mechanical drawing |
| Weight (kg) | Approximately 1,246 kg class |
| Product status | Active |
The 20G11BC1K2JN4NNNNN is a very large industrial AC drive.
Its most important electrical specification is the 1,175 A output-current rating.
This places the drive well above the size range normally associated with small machine drives. It is intended for large motors and substantial mechanical loads.
The published 400 V rating class, 1,175 A output and 710 kW Normal Duty / 560 kW Heavy Duty ratings identify this as a Frame 9 high-power configuration.
The power rating should be understood together with the load duty.
| Duty Category | Approximate Power Rating |
|---|---|
| Light Duty | Approximately 800 kW |
| Normal Duty | 710 kW |
| Heavy Duty | 560 kW |
The Normal Duty rating is particularly important for applications where the motor operates continuously under a relatively stable industrial load.
The Heavy Duty rating is more relevant when the motor experiences greater overload requirements.
The final selection should always be based on motor nameplate current, load torque, overload requirements and actual operating conditions rather than simply comparing motor kW values.
The drive is designed for the 400 V AC three-phase industrial voltage class.
This makes it suitable for industrial installations using the common 380–400 V class power system.
A typical installation can be represented as:
Three-Phase AC Supply → PowerFlex 755 Drive → Large AC Motor → Mechanical Load
The drive regulates the electrical power supplied to the motor, allowing motor speed and operating characteristics to be adjusted according to the process requirement.
The 1,175 A rating is one of the strongest reasons to choose this model.
A current rating of this magnitude makes the drive appropriate for large motor-driven equipment such as:
The 20G11BC1K2JN4NNNNN uses a Frame 9 configuration.
Frame 9 is intended for large-power drive applications and provides the physical architecture necessary for high-current power conversion.
The frame accommodates major drive components such as:
The Frame 9 designation is therefore not just a catalog classification. It also indicates that the physical installation is significantly larger than that of ordinary industrial VFDs.
The published configuration uses a Type 1 / IP20 enclosure arrangement with a 600 mm deep MCC-style cabinet.
This configuration is intended for installation in a suitable industrial electrical environment.
The enclosure should not be treated as an outdoor weatherproof enclosure.
The installation environment should therefore provide suitable protection from:
The catalog information identifies the configuration as a 600 mm deep MCC-style design.
The 600 mm depth is an important planning dimension for cabinet integration, cable routing and maintenance access.
The exact overall height and width should be taken from the mechanical drawing applicable to the final supplied configuration rather than estimated from the frame number alone.
| Mechanical Parameter | Specification |
|---|---|
| Model | 20G11BC1K2JN4NNNNN |
| Frame | Frame 9 |
| Enclosure | Type 1 / IP20 |
| Cabinet type | MCC style |
| Depth | 600 mm |
| Overall height | Configuration-dependent |
| Overall width | Configuration-dependent |
| Cooling | Forced air |
| Installation | Industrial electrical room / MCC lineup |
| Final dimensional reference | Applicable mechanical drawing |
This approach is particularly important for projects where the drive must fit into an existing electrical room or MCC lineup.
The 20G11BC1K2JN4NNNNN is heavy industrial equipment.
For preliminary engineering and logistics planning, this configuration can be treated as being in the approximately 1,246 kg class, or about 1.25 metric tons.
| Weight Parameter | Specification |
|---|---|
| Model | 20G11BC1K2JN4NNNNN |
| Equipment category | High-power industrial drive |
| Approximate weight (kg) | 1,246 kg class |
| Approximate metric tons | 1.25 t |
| Transportation | Heavy equipment handling |
| Floor loading | Must be checked |
| Lifting equipment | Required |
| Final shipping weight | Confirm from equipment documentation |
The approximate weight should be used for preliminary planning.
For crane selection, floor-loading calculations, transportation and final mechanical engineering, the actual shipping and equipment documentation should take priority.
The 20G11BC1K2JN4NNNNN is designed to provide controlled operation of large AC motors.
Instead of allowing the motor to operate only at the fixed frequency of the incoming power supply, the drive can control the electrical conditions supplied to the motor.
This allows the motor’s speed and torque behavior to be coordinated with the production process.
For example, a large pump does not necessarily need to operate at full speed all the time.
A large ventilation fan may need different airflow levels at different times.
A conveyor may require controlled acceleration and deceleration.
The variable-frequency drive provides the electrical control required for these applications.
The drive can be integrated into a larger industrial automation architecture.
A typical system may contain:
PLC
↓
Industrial Ethernet Network
↓
PowerFlex 755
↓
Large AC Motor
↓
Pump / Fan / Conveyor / Process Machine
At the same time, maintenance personnel can interact locally with the drive through the operator interface.
This gives the system two practical layers of operation:
Centralized automation control
and
Local maintenance and commissioning control.
The JN4 configuration is particularly useful when local operator access is required.
The local Enhanced LCD / Full Numeric interface allows technicians to interact with the drive directly.
Typical activities include:
The local interface becomes particularly valuable during startup and maintenance.
Imagine a large pump station where the PLC system has not yet been fully commissioned.
A technician can still work directly with the drive to verify motor parameters and basic operation.
Likewise, during maintenance, the technician can inspect the drive without depending entirely on the control-room HMI.
This can save time during:
The PowerFlex 755 platform supports integration into industrial Ethernet-based automation systems.
The embedded Ethernet capability can be used for communication between the drive and plant automation equipment.
Typical systems can include:
This is particularly useful for large plants where several large drives need to be monitored and controlled from a central automation system.
The configuration uses a filtered arrangement with the CM jumper installed.
EMC performance is important in large VFD installations because high-frequency switching can create electrical noise.
The overall installation should therefore consider:
The internal filtering is an important part of the drive configuration, but proper EMC installation remains a system-level responsibility.
The published configuration specifies no dynamic braking.
This can be appropriate for many large industrial applications where rapid deceleration is not required.
For example, a large centrifugal pump may be allowed to slow down naturally after the speed reference is reduced.
A large fan can behave similarly.
However, applications with large rotating inertia or strict stopping-time requirements should be evaluated separately.
Examples include:
The 20G11BC1K2JN4NNNNN can be used in a wide range of heavy industrial applications.
Typical application categories include:
Large pumping systems are one of the strongest application areas for this drive.
Possible applications include:
Variable-speed operation allows the pump to be operated according to process demand rather than simply running continuously at maximum speed.
Wastewater-treatment plants can contain very large pumps and blowers.
The drive can be used for:
The local operator interface is also useful during maintenance because technicians can work directly at the electrical equipment while checking the associated mechanical equipment.
Large fans can require substantial motor power.
Examples include:
Variable-speed control allows airflow to be adjusted to actual process requirements.
Large blowers are common in:
The drive can provide controlled starting and speed regulation while integrating the blower motor into a larger plant control system.
Large conveyors can have significant mechanical inertia.
Controlled acceleration can help reduce mechanical shock to:
This can be especially useful in mining and bulk-material handling.
The high-current capability makes this model suitable for certain large mining installations.
Potential applications include:
Mining environments require careful attention to dust, temperature, vibration and maintenance access.
Large cement and aggregate plants use many high-power motors.
Potential applications include:
The PowerFlex 755 platform is well suited to installations where many large motors need to be incorporated into one automation strategy.
Large manufacturing facilities may require high-capacity cooling-water systems.
The drive can control pump speed according to actual cooling requirements.
Possible advantages include:
Certain large compressors can also benefit from variable-speed motor control.
Potential applications include:
Compressor applications require detailed evaluation of torque, operating range and process requirements before final drive selection.
| Advantage | Description |
|---|---|
| Very high current capability | 1,175 A output rating |
| High power capacity | Approximately 800 kW Light Duty |
| Normal Duty capacity | 710 kW |
| Heavy Duty capacity | 560 kW |
| Frame 9 construction | Suitable for large industrial motors |
| 400 V AC class | Suitable for common industrial power systems |
| Air cooling | Appropriate for properly engineered electrical rooms |
| 600 mm MCC-style configuration | Designed for industrial electrical lineups |
| Local operator interface | Convenient for commissioning and maintenance |
| EtherNet/IP capability | Supports networked industrial control |
| EMC filtering | Helps manage electrical noise |
| AC precharge | Suitable for high-power DC-bus architecture |
| PowerFlex 755 platform | Broad application flexibility |
| High scalability | Multiple related ratings are available |
| Industrial construction | Designed for demanding applications |
The most obvious advantage is the large amount of available output current.
With 1,175 A, the drive is capable of handling motors that would be far beyond the range of ordinary compact VFDs.
This makes it suitable for large pumps, fans, blowers, conveyors and other heavy industrial equipment.
The 710 kW Normal Duty rating provides a substantial capacity margin for many industrial applications.
For a continuously operating process machine, this rating can provide a useful reference point when matching the drive with the motor.
However, engineers should still verify the motor’s actual current and load profile before making the final selection.
The 560 kW Heavy Duty rating is important for applications where the load is more demanding.
Examples include equipment with:
The Heavy Duty rating gives engineers another way to match the drive to the actual load.
The JN4 configuration is useful when local access is important.
A technician standing at the drive can inspect operating information without having to walk back to a control room.
This is particularly useful in large plants where the drive may be installed hundreds of meters away from the main operator station.
The PowerFlex 755 platform allows the drive to be incorporated into an automation network.
This means a plant can combine local drive control with centralized:
The drive can therefore function as part of the complete automation system rather than operating as an isolated device.
The PowerFlex 755 family offers multiple current and power ratings.
This makes standardization easier for large industrial facilities.
A plant may use smaller configurations for moderate-size motors and larger Frame 9 configurations for major process equipment.
The engineering and maintenance teams can therefore work with a consistent general drive architecture.
The following five models are useful alternatives or related configurations within the PowerFlex 755 family.
| Model | Series | Voltage | Current / Rating | Frame | Depth | HIM | Weight (kg) |
|---|---|---|---|---|---|---|---|
| 20G11BC910JN0NNNNN | PowerFlex 755 | 400 VAC | ~910 A / 500 kW ND | 9 | 600 mm | No HIM | ~1,250 |
| 20G11BC1K0JN0NNNNN | PowerFlex 755 | 400 VAC | ~1,040 A / 560 kW ND | 9 | 600 mm | No HIM | ~1,250 |
| 20G11BC1K1JN0NNNNN | PowerFlex 755 | 400 VAC | ~1,090 A / 630 kW ND | 9 | 600 mm | No HIM | ~1,250 |
| 20G11BC1K2JN2NNNNN | PowerFlex 755 | 400 VAC | 1,175 A / 710 kW ND | 9 | 600 mm | Enhanced LCD | ~1,246 |
| 20G11BC1K5JN2NNNNN | PowerFlex 755 | 400 VAC | ~1,480 A / 850 kW ND | 9 | 600 mm | Enhanced LCD | Configuration dependent |
The 1K2 rating is the direct capacity class of the target model.
The 910 A, 1K0 and 1K1 configurations provide lower-capacity alternatives, while the 1K5 configuration provides a higher-capacity option.
The published 400 V rating table identifies the 1K2 class at 1,175 A / 710 kW Normal Duty, with the next larger rating class extending to approximately 1,480 A / 850 kW Normal Duty.
The 20G11BC910JN0NNNNN is a lower-capacity Frame 9 PowerFlex 755 configuration.
| Parameter | Specification |
|---|---|
| Model | 20G11BC910JN0NNNNN |
| Series | PowerFlex 755 |
| Voltage | 400 VAC class |
| Current | Approximately 910 A |
| Normal Duty | Approximately 500 kW |
| Heavy Duty | Approximately 400 kW |
| Frame | 9 |
| Cooling | Air cooled |
| Enclosure | IP20 / Type 1 |
| Cabinet | 600 mm MCC style |
| HIM | No HIM |
| Depth | 600 mm |
| Dimensions | Frame 9; exact height and width configuration dependent |
| Weight (kg) | Approximately 1,250 kg class |
This model is useful when the motor current requirement is lower than the 1,175 A capacity of the target drive.
The 20G11BC1K0JN0NNNNN occupies the next capacity level.
| Parameter | Specification |
|---|---|
| Model | 20G11BC1K0JN0NNNNN |
| Series | PowerFlex 755 |
| Voltage | 400 VAC class |
| Current | Approximately 1,040 A |
| Normal Duty | Approximately 560 kW |
| Heavy Duty | Approximately 500 kW |
| Frame | 9 |
| Cooling | Air cooled |
| Enclosure | IP20 / Type 1 |
| Cabinet | 600 mm MCC style |
| HIM | No HIM |
| Depth | 600 mm |
| Dimensions | Frame 9; exact height and width configuration dependent |
| Weight (kg) | Approximately 1,250 kg class |
The 20G11BC1K1JN0NNNNN is very close to the target rating.
| Parameter | Specification |
|---|---|
| Model | 20G11BC1K1JN0NNNNN |
| Series | PowerFlex 755 |
| Voltage | 400 VAC class |
| Current | Approximately 1,090 A |
| Light Duty | Approximately 710 kW |
| Normal Duty | Approximately 630 kW |
| Heavy Duty | Approximately 500 kW |
| Frame | 9 |
| Cooling | Air cooled |
| Enclosure | IP20 / Type 1 |
| Cabinet | 600 mm MCC style |
| HIM | No HIM |
| Depth | 600 mm |
| Dimensions | Frame 9; exact height and width configuration dependent |
| Weight (kg) | Approximately 1,250 kg class |
This is a practical alternative where the required motor current is slightly below the 1,175 A target rating.
The 20G11BC1K2JN2NNNNN is electrically very close to the target model.
| Parameter | Specification |
|---|---|
| Model | 20G11BC1K2JN2NNNNN |
| Series | PowerFlex 755 |
| Voltage | 400 VAC |
| Output current | 1,175 A |
| Light Duty | Approximately 800 kW |
| Normal Duty | 710 kW |
| Heavy Duty | 560 kW |
| Frame | 9 |
| Cooling | Air cooled |
| Enclosure | IP20 / Type 1 |
| Cabinet | 600 mm MCC style |
| Local HIM | Enhanced LCD / Full Numeric |
| Depth | 600 mm |
| Dimensions | Frame 9; exact height and width configuration dependent |
| Weight (kg) | Approximately 1,246 kg class |
This is one of the most logical alternatives when the electrical capacity should remain the same but a different local-interface configuration is acceptable.
The 20G11BC1K5JN2NNNNN provides higher current and power capacity.
| Parameter | Specification |
|---|---|
| Model | 20G11BC1K5JN2NNNNN |
| Series | PowerFlex 755 |
| Voltage | 400 VAC |
| Current | Approximately 1,480 A |
| Normal Duty | Approximately 850 kW |
| Heavy Duty | Approximately 710 kW |
| Frame | 9 |
| Cooling | Air cooled |
| Enclosure | IP20 / Type 1 |
| Cabinet | 600 mm MCC style |
| Local HIM | Enhanced LCD / Full Numeric |
| Depth | 600 mm |
| Dimensions | Frame 9; exact height and width configuration dependent |
| Weight (kg) | Configuration dependent; approximately 1,250 kg class |
This is a logical choice when the motor’s current requirement exceeds the 1,175 A capability of the 1K2 configuration.
For a broader comparison, the following models provide useful references across the same brand and related PowerFlex product families.
| Model | Series | Voltage Class | Current / Power Class | Typical Application | Dimensions | Weight (kg) |
|---|---|---|---|---|---|---|
| 20G11BC1K2JN2NNNNN | PowerFlex 755 | 400 VAC | 1,175 A / 710 kW ND | Large pumps, fans, conveyors | 600 mm deep MCC style | ~1,246 |
| 20G11BC1K2JN0NNNNN | PowerFlex 755 | 400 VAC | 1,175 A / 710 kW ND | Centralized large-motor control | 600 mm deep MCC style | ~1,246 |
| 20G11BC1K5JN2NNNNN | PowerFlex 755 | 400 VAC | ~1,480 A / 850 kW ND | Larger industrial motors | 600 mm deep MCC style | Configuration dependent |
| 21G11BC1K2JN2NNNNN-ND-L1-P3 | PowerFlex 755 Packaged | 400 VAC | 1,175 A / 710 kW ND | Packaged large-motor systems | 600 mm deep MCC style | Configuration dependent |
| 25B-D030N114 | PowerFlex 525 | 480 VAC class | 30 A class | Compact machine applications | Compact frame | Configuration dependent |
The first four are more directly relevant to high-power industrial applications.
The PowerFlex 525 belongs to a considerably smaller drive class and is better suited to smaller machines rather than the large motors normally associated with the target 1,175 A configuration.
This is a packaged PowerFlex 755 configuration with the same major 400 V / 1,175 A / 710 kW Normal Duty / 560 kW Heavy Duty power class.
| Parameter | Specification |
|---|---|
| Model | 21G11BC1K2JN2NNNNN-ND-L1-P3 |
| Series | PowerFlex 755 Packaged Drive |
| Voltage | 400 V AC, 3 phase |
| Output current | 1,175 A |
| Normal Duty | 710 kW |
| Heavy Duty | 560 kW |
| Frame | 9 |
| Cooling | Air cooled |
| Enclosure | Type 1 |
| Cabinet depth | 600 mm |
| Input type | AC input with precharge |
| Input protection | Circuit breaker |
| Input reactor | 3% |
| Dynamic braking | None |
| Door-mounted HIM | IP20 / NEMA 1 |
| Depth | 600 mm |
| Dimensions | Packaged Frame 9 configuration; exact height and width configuration dependent |
| Weight (kg) | Configuration dependent |
This model is particularly interesting for projects where a more complete packaged-drive arrangement is required.
The JN4 and JN2 configurations are closely related.
| Parameter | JN4 | JN2 |
|---|---|---|
| Model | 20G11BC1K2JN4NNNNN | 20G11BC1K2JN2NNNNN |
| Series | PowerFlex 755 | PowerFlex 755 |
| Voltage | 400 VAC | 400 VAC |
| Output current | 1,175 A | 1,175 A |
| Normal Duty | 710 kW | 710 kW |
| Heavy Duty | 560 kW | 560 kW |
| Frame | 9 | 9 |
| Cabinet depth | 600 mm | 600 mm |
| Cooling | Air cooled | Air cooled |
| Local interface | Enhanced LCD / Full Numeric | Enhanced LCD / Full Numeric |
| Main difference | Higher-protection HIM configuration | Standard local HIM configuration |
| Typical use | More demanding local-interface environment | Conventional indoor industrial environment |
| Weight | ~1,246 kg class | ~1,246 kg class |
The key distinction is not the basic electrical rating.
Both belong to the same 1,175 A / 710 kW Normal Duty / 560 kW Heavy Duty power class.
The selection is mainly influenced by the local interface and installation requirements.
| Parameter | JN4 | JN0 |
|---|---|---|
| Model | 20G11BC1K2JN4NNNNN | 20G11BC1K2JN0NNNNN |
| Voltage | 400 VAC | 400 VAC |
| Current | 1,175 A | 1,175 A |
| Normal Duty | 710 kW | 710 kW |
| Heavy Duty | 560 kW | 560 kW |
| Frame | 9 | 9 |
| Depth | 600 mm | 600 mm |
| Local HIM | Yes | No |
| Centralized PLC control | Yes | Yes |
| Local commissioning | Excellent | More dependent on external tools/interface |
| Weight | ~1,246 kg class | ~1,246 kg class |
If technicians regularly need to work at the cabinet, the JN4 configuration can be more convenient.
If the installation is completely centralized and the local interface is unnecessary, a JN0 configuration may be preferable.
| Parameter | 1K2 JN4 | 1K5 JN2 |
|---|---|---|
| Model | 20G11BC1K2JN4NNNNN | 20G11BC1K5JN2NNNNN |
| Voltage | 400 VAC | 400 VAC |
| Output current | 1,175 A | Approximately 1,480 A |
| Normal Duty | 710 kW | Approximately 850 kW |
| Heavy Duty | 560 kW | Approximately 710 kW |
| Frame | 9 | 9 |
| Depth | 600 mm | 600 mm |
| Cooling | Air cooled | Air cooled |
| HIM | Enhanced LCD / Full Numeric | Enhanced LCD / Full Numeric |
| Application | Large motors | Larger motors |
| Weight | ~1,246 kg class | Configuration dependent |
The 1K5 becomes more attractive when the motor current is higher than 1,175 A.
| Application | Recommended Configuration |
|---|---|
| Large water pump | 20G11BC1K2JN4 |
| Cooling-water pump | 20G11BC1K2JN4 |
| Large centrifugal fan | 20G11BC1K2JN4 |
| Industrial blower | 20G11BC1K2JN4 |
| Large conveyor | 20G11BC1K2JN4 |
| Mining conveyor | 20G11BC1K2JN4 |
| Cement-plant fan | 20G11BC1K2JN4 |
| Large process pump | 20G11BC1K2JN4 |
| Wastewater aeration | 20G11BC1K2JN4 |
| Centralized automation | JN0 / JN2 / JN4 |
| Local maintenance required | JN2 / JN4 |
| More demanding local interface environment | JN4 |
| Motor above 1,175 A | 1K5 or higher class |
| Approximate Motor Current | Relevant PowerFlex 755 Rating Class |
|---|---|
| ~900 A | 20G11BC910 |
| ~1,040 A | 20G11BC1K0 |
| ~1,090 A | 20G11BC1K1 |
| 1,175 A | 20G11BC1K2 |
| ~1,465 A | 20G11BC1K4 |
| ~1,480 A | 20G11BC1K5 |
| Above this range | Larger Frame 9/10 configurations |
The 400 V rating tables place the 1K2 class at 1,175 A and 710 kW Normal Duty, while larger configurations increase current and power capacity.
The drive should be selected primarily according to the motor’s actual electrical requirements.
Important motor information includes:
| Motor Parameter | Importance |
|---|---|
| Motor voltage | Must match the drive voltage class |
| Motor current | One of the most important sizing factors |
| Motor power | General capacity reference |
| Motor frequency | Determines base operating point |
| Motor speed | Defines operating range |
| Motor torque | Determines load compatibility |
| Starting torque | Important for demanding loads |
| Overload requirement | Determines duty selection |
| Acceleration time | Influences current demand |
| Deceleration time | Influences braking requirements |
| Duty cycle | Influences thermal loading |
| Cable length | Affects installation and EMC |
| Motor insulation | Important for VFD operation |
The installation of a 1,175 A drive requires considerably more planning than the installation of a small VFD.
The project should consider:
The drive uses an air-cooled design.
The electrical room therefore needs adequate ventilation and temperature management.
Maintenance personnel should periodically inspect:
A high-power drive operating in a poorly ventilated electrical room can experience unnecessary thermal stress.
A practical preventive-maintenance program can include:
A parameter backup is strongly recommended after commissioning.
The backup should contain the final operating configuration.
Important information can include:
Keeping a current parameter backup can significantly reduce downtime after equipment replacement.
The approximate 1,246 kg weight class means that the equipment must be treated as heavy industrial machinery during transportation and installation.
The installation plan should consider:
This is particularly important for projects where the equipment has to be moved through an existing factory or electrical room.
A suitable electrical room should provide:
The physical size and weight of the drive should be considered during the architectural and electrical-room design stage rather than after the equipment arrives.
A practical commissioning sequence can include the following.
Confirm that the installed unit is:
20G11BC1K2JN4NNNNN
This is important because the PowerFlex catalog number contains information about voltage class, rating, enclosure, filtering, operator interface and other configuration characteristics.
Confirm:
Record the motor nameplate:
Enter the correct motor and application parameters.
Do not simply copy parameters from another motor unless the motors and application are genuinely equivalent.
Verify rotation before connecting the motor to the full mechanical process.
This is particularly important for pumps, fans and conveyors.
Operate the motor at a controlled low speed.
Check:
Observe:
Verify communication between:
A large installation can use the drive in a structure such as:
Plant SCADA
↓
Operator HMI
↓
PLC / Controller
↓
Industrial Ethernet
↓
PowerFlex 755
↓
20G11BC1K2JN4NNNNN
↓
400 V AC Motor
↓
Pump / Fan / Conveyor / Process Equipment
The local HIM provides another access point for maintenance personnel.
There are several practical reasons to select this model.
The first is its 1,175 A output capability.
The second is its 710 kW Normal Duty rating.
The third is the 560 kW Heavy Duty rating.
The fourth is its Frame 9 high-power construction.
The fifth is the 400 V AC three-phase design.
The sixth is the 600 mm deep MCC-style cabinet arrangement.
The seventh is the local Enhanced LCD / Full Numeric operator interface.
The eighth is its ability to participate in a modern industrial automation architecture.
| Category | Detailed Specification |
|---|---|
| Model | 20G11BC1K2JN4NNNNN |
| Brand | Allen-Bradley |
| Series | PowerFlex 755 |
| Product family | PowerFlex 750-Series |
| Product type | 755 AC Packaged Drive |
| Product status | Active |
| Input voltage | 400 VAC |
| Input phase | 3 phase |
| Output current | 1,175 A |
| Light Duty | Approximately 800 kW |
| Normal Duty | 710 kW |
| Heavy Duty | 560 kW |
| Frame | 9 |
| Cooling | Air cooled |
| Enclosure | IP20 / Type 1 |
| Cabinet style | 600 mm Deep MCC Style |
| Input type | AC Input with Precharge |
| EMC configuration | Filtered |
| CM jumper | Installed |
| Dynamic braking | None |
| Local interface | Enhanced LCD / Full Numeric HIM |
| Communication | Embedded EtherNet/IP |
| Typical applications | Pumps, fans, blowers, conveyors, mining, cement, water treatment, process machinery |
| Depth | 600 mm |
| Overall dimensions | Frame 9; exact height and width configuration dependent |
| Weight (kg) | Approximately 1,246 kg class |
The 20G11BC1K2JN4NNNNN is a high-capacity industrial variable-frequency drive belonging to the Allen-Bradley PowerFlex 755 series.
Its electrical rating of 1,175 A, combined with 710 kW Normal Duty and 560 kW Heavy Duty, puts it firmly into the large industrial motor-control category.
It is therefore not intended for ordinary small machinery.
Its natural application environment is large-scale industrial equipment where motor power, process control and reliable automation integration are important.
The Frame 9 construction and 600 mm deep MCC-style configuration also indicate that mechanical planning is a major part of installation.
The final cabinet height and width should be obtained from the applicable mechanical drawing, while the approximate 1,246 kg weight class should be considered when planning transportation, lifting and floor loading.
The JN4 configuration is especially attractive when local operator access is required.
For a large pump, fan, conveyor or process motor, technicians can use the local interface during commissioning and maintenance while the drive remains connected to the plant’s centralized automation system.
The PowerFlex 755 platform also provides a useful range of related ratings.
The lower-capacity 20G11BC910, 20G11BC1K0 and 20G11BC1K1 configurations can be considered when the motor current is lower.
The 20G11BC1K2 family is the direct rating class for the target product.
The larger 20G11BC1K4 and 20G11BC1K5 configurations become relevant when the motor requires additional current capacity.
For the same electrical rating, the 20G11BC1K2JN2NNNNN is one of the closest alternatives.
The main consideration between JN2 and JN4 is the local-interface configuration and the environmental requirements of the installation rather than the basic 1,175 A power rating.
The 20G11BC1K2JN0NNNNN is another closely related choice where local operator access is not required.
For a fully centralized PLC/HMI installation, this can be a practical configuration.
For a plant where maintenance personnel frequently operate directly at the cabinet, the JN2 or JN4 configurations are generally more convenient.
The 20G11BC1K5 class is the direction to consider when the required motor current exceeds the 1,175 A capability.
The published 400 V rating information places the 1K5 class at approximately 1,480 A and 850 kW Normal Duty, making it a natural higher-capacity comparison for the 1K2 configuration.
In practical terms, the 20G11BC1K2JN4NNNNN can be summarized as a 400 V AC, three-phase, 1,175 A, Frame 9, air-cooled PowerFlex 755 industrial AC drive with approximately 800 kW Light Duty capability, 710 kW Normal Duty capability, 560 kW Heavy Duty capability, 600 mm MCC-style depth, filtered configuration, AC input with precharge, no dynamic braking and a local Enhanced LCD / Full Numeric operator interface.
Its strongest applications are large pumps, fans, blowers, conveyors, water-treatment equipment, mining machinery, cement-plant equipment, cooling systems and other high-power industrial processes.
The most important selection point is not simply the motor’s kW rating.
For a real engineering project, the motor’s nameplate current, voltage, torque requirement, overload profile, acceleration/deceleration requirements, operating speed range, braking requirements, environmental conditions and installation arrangement should all be reviewed before final selection.
Overall, the 20G11BC1K2JN4NNNNN is a strong high-power drive choice for industrial plants that need substantial motor-current capacity together with local commissioning capability and integration into a centralized automation system.