The 1747-PIC is a programming and communication interface module used in SLC 500 programmable logic controller systems. It is designed to connect a personal computer to SLC 5/01 and SLC 5/02 controllers through a serial communication link, enabling program upload, download, and online monitoring.
This device acts as a bridge between programming software and PLC hardware, making it an essential tool for maintenance, commissioning, and troubleshooting of legacy SLC systems.
It is widely used in industrial environments where older SLC 500 controllers are still operating and require reliable programming access.
| Item | Details |
|---|---|
| Brand | Allen Bradley |
| Product Model | 1747-PIC |
| Product Type | Programming Interface Converter |
| Product Family | SLC 500 Series |
| Series | SLC Communication Accessories |
| Main Function | PC-to-PLC Communication Interface |
| Communication Type | RS-232 to DH-485 conversion |
| Installation Type | External interface cable/device |
The SLC 500 system is a modular PLC platform used in industrial automation applications.
Communication between programming devices and PLC controllers is achieved through specialized interface modules and cables.
The 1747-PIC belongs to the communication accessory family, enabling legacy serial communication between a PC and SLC controllers using DH-485 protocol.
It is especially important in older industrial systems where Ethernet-based communication is not available.
| Parameter | Specification |
|---|---|
| Model | 1747-PIC |
| Product Type | Programming Interface Converter |
| Function | PC to PLC communication interface |
| Communication Protocol | DH-485 |
| PC Interface | RS-232 serial port |
| PLC Interface | DH-485 network |
| Supported Controllers | SLC 5/01, SLC 5/02 |
| Software Compatibility | RSLogix / programming tools for SLC |
| Communication Speed | Up to 19.2 kbps (DH-485 standard) |
| Power Supply | Powered via PC serial port |
| Isolation | Basic electrical isolation |
| Cable Length | ~2–3 meters typical |
| Operating Temperature | 0°C to 60°C |
| Storage Temperature | -40°C to 85°C |
| Humidity Range | 5%–95% non-condensing |
| Dimensions | ~12 × 6 × 2 cm |
| Weight (kg) | ~0.25 kg |
The 1747-PIC converts RS-232 signals from a computer into DH-485 protocol used by SLC controllers.
This enables direct programming and monitoring of PLC systems.
It is designed specifically for older SLC 5/01 and 5/02 controllers that do not support Ethernet communication.
The interface requires no external power supply and operates directly through the PC serial port.
Provides reliable communication for programming and troubleshooting in industrial environments.
The compact structure makes it easy to carry and use in field maintenance applications.
Used for uploading and downloading PLC programs to SLC controllers.
Allows engineers to monitor real-time PLC operation and diagnose faults.
Used in servicing and maintaining legacy automation systems.
Used during machine setup and configuration of PLC logic.
Widely used in older industrial plants still operating SLC 500 systems.
| Advantage | Description |
|---|---|
| Direct PC Connection | Enables PLC programming from computer |
| Supports Legacy Systems | Works with SLC 5/01 and 5/02 |
| No External Power Required | Powered via serial port |
| Simple Operation | Plug-and-use interface |
| Stable Communication | Reliable DH-485 data transfer |
| Portable Design | Easy field use |
| Cost-Effective Maintenance Tool | Reduces service complexity |
| Industrial Reliability | Suitable for harsh environments |
| Model | Product Type | Main Function | Application | Dimensions | Weight (kg) |
|---|---|---|---|---|---|
| 1747-PIC | Interface Converter | PC to PLC communication | SLC programming | 12 × 6 × 2 cm | 0.25 kg |
| 1747-UIC | USB Interface | USB to DH-485 converter | Modern PC connection | 10 × 5 × 2 cm | 0.15 kg |
| 1747-CP3 | Programming Cable | RS-232 programming cable | SLC communication | 200 cm cable | 0.20 kg |
| 1747-CP1 | Communication Cable | DH-485 network cable | PLC networking | 200 cm cable | 0.18 kg |
| 1747-AIC | Interface Module | Advanced interface adapter | Multi-controller systems | 12 × 6 × 3 cm | 0.30 kg |
| Model | Product Category | Main Features | Application Area | Dimensions | Weight (kg) |
|---|---|---|---|---|---|
| 1747-L541 | CPU Module | SLC 5/04 processor | Industrial automation | 25 × 17 × 6 cm | 0.45 kg |
| 1747-L542 | CPU Module | High-performance CPU | Distributed systems | 25 × 16.6 × 5.9 cm | 0.40 kg |
| 1747-L551 | CPU Module | Ethernet-enabled CPU | Network automation | 25 × 16.5 × 5.6 cm | 0.42 kg |
| 1756-EN2TR | Ethernet Module | Dual Ethernet/IP ports | Industrial networking | 14 × 11 × 8 cm | 0.45 kg |
| 1769-L33ER | Compact PLC | Built-in Ethernet/IP | Machine automation | 18 × 12 × 9 cm | 0.92 kg |
The 1747-PIC serves as a critical communication bridge between engineering software and SLC PLC controllers.
It enables programming, configuration, and diagnostics of legacy PLC systems that do not support modern communication protocols.
It remains an essential tool for maintaining older industrial automation systems.
The device is connected between a PC serial port and PLC communication port.
No configuration or software installation is required beyond standard PLC programming software.
Maintenance is minimal due to its simple hardware structure.
It is primarily replaced when upgrading to newer communication interfaces such as USB-based converters.
The 1747-PIC is widely used in industrial maintenance environments due to its simplicity and compatibility with legacy PLC systems.
It remains an important tool for engineers working with SLC 500 controllers in existing factories.
Its stable communication performance ensures reliable programming operations in field conditions.
The Allen Bradley 1747-PIC is a serial communication interface designed for SLC 500 PLC systems.
It enables PC-to-PLC programming and monitoring through DH-485 communication, making it essential for legacy system maintenance.
Its simplicity, portability, and reliability make it a widely used tool in industrial automation support and troubleshooting.