Product Overview The Woodward MRI4A0AB is a digital feeder protection relay from the MRI4 HighPROTEC family. It is used to monitor electrical circuits and initiate protective tripping when configured fa……
Woodward MRI4A0AB Digital Protection Relay
  • Woodward
  • MRI4A0AB
  • Digital Protection Relay
  • USA
  • 250 × 130 × 70 mm
  • 0.85 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 8

Our advantage

Woodward MRI4A0AB Digital Protection Relay

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Woodward MRI4A0AB Digital Protection Relay

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Woodward MRI4A0AB Digital Protection Relay

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Woodward MRI4A0AB Digital Protection Relay

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Woodward MRI4A0AB is a digital feeder protection relay from the MRI4 HighPROTEC family. It is used to monitor electrical circuits and initiate protective tripping when configured fault conditions are detected. In a medium-voltage switchgear installation, the relay evaluates current measurements from instrument transformers and coordinates with the circuit breaker to isolate a faulted feeder.

For example, when a short circuit develops on an industrial distribution feeder, the measured phase current can rise significantly above its normal operating level. The MRI4A0AB evaluates the measured current against its configured pickup thresholds and timing characteristics. If the protection criteria are met, the relay operates its assigned trip output, allowing the circuit breaker to disconnect the affected section.

The MRI4 platform supports multiple protection elements, including non-directional overcurrent and earth-fault protection. Depending on the configured application, these functions can use definite-time or inverse-time characteristics. This allows protection engineers to coordinate the relay with upstream and downstream protective devices instead of relying on a single fixed trip threshold.

The complete order code matters when selecting a replacement. The MRI4A0AB designation identifies a particular configuration, and the available communication interfaces, current-input arrangement, and mounting options should be checked against the installed unit. Correct selection depends on more than matching the relay’s product name.


Technical Specifications

Parameter Specification
Manufacturer Woodward
Model MRI4A0AB
Product Family HighPROTEC MRI4
Product Type Digital Protection Relay
Protection Application Feeder protection
Primary Functions Overcurrent and short-circuit protection
Additional Functions Earth-fault protection, according to configuration
Tripping Characteristics Definite-time and inverse-time, where supported
Current Measurement Instrument-transformer inputs; exact configuration must be verified
Communication Depends on the installed hardware and protocol option
Installation Panel mounting; verify the housing variant
Size 250 × 130 × 70 mm
Weight 0.85 kg

Product Features

  • Digital feeder protection: Evaluates electrical measurements and executes configured protection logic.
  • Overcurrent monitoring: Detects phase-current conditions that exceed the selected pickup threshold.
  • Short-circuit protection: Supports rapid fault clearance through the assigned trip circuit.
  • Earth-fault protection: Supports earth-current protection where the installed configuration includes the required function.
  • Adjustable timing characteristics: Allows protection delays to be coordinated with other devices.
  • Disturbance recording: The MRI4 platform supports recording functions that help engineers investigate protection events.
  • Configurable protection elements: Enables the relay to be adapted to the requirements of the protected circuit.
  • System integration: Works with current transformers, circuit breakers, and associated control wiring.
  • Application-specific communication: Communication capabilities depend on the selected hardware and protocol configuration.

Working Principle

The MRI4A0AB operates by receiving electrical measurement signals and evaluating them against the protection settings configured for the feeder. When a measured quantity meets the criteria for a protection element, the relay applies the relevant timing characteristic and initiates the assigned output action.

A typical feeder protection sequence is:

Current Transformers → MRI4A0AB → Trip Circuit → Circuit Breaker

Under normal operating conditions, the measured current remains within the configured limits. When an overload or short circuit occurs, the phase-current measurement may exceed the pickup threshold. The relay then evaluates the magnitude and duration of the abnormal condition.

With definite-time protection, the relay operates after a configured delay if the fault condition persists. With inverse-time protection, the operating time changes according to the measured fault current and the selected characteristic. The appropriate setting depends on the protected equipment, available fault current, and coordination requirements of the electrical network.

Earth-fault protection follows a similar principle but evaluates the current signal associated with the configured earth-current measurement circuit. If the measured signal meets the applicable pickup and timing criteria, the relay can initiate a trip through its assigned output.

The relay does not interrupt the main power circuit directly. The trip circuit and circuit-breaker mechanism must operate correctly to isolate the fault. Commissioning therefore needs to verify both the relay’s measurement and protection response and the complete breaker trip path.


Role in an Electrical Protection Architecture

The MRI4A0AB acts as the protection decision-making component between the electrical measurement circuits and the switching equipment. It evaluates fault conditions and sends the appropriate trip command when the configured protection criteria are satisfied.

Protected Feeder → Current Transformers → MRI4A0AB → Trip Circuit → Circuit Breaker

System Element Function
Protected Feeder Supplies power to downstream equipment
Phase Current Transformers Provide current signals for overcurrent protection
Earth-Current Measurement Circuit Supplies the signal used by the configured earth-fault function
MRI4A0AB Evaluates measurements and executes configured protection logic
Auxiliary Power Supply Powers the relay according to the installed configuration
Trip Output Circuit Transfers the protection command to the breaker
Circuit Breaker Disconnects the protected circuit
Protection Coordination Scheme Establishes timing and selectivity between protective devices
Supervisory System Receives available status or measurement information where communication is configured

Protection settings must reflect the actual CT ratios, grounding arrangement, fault-current levels, and upstream/downstream coordination requirements. The exact communication and input/output configuration should be confirmed for the installed unit.


Industrial Applications

Application Typical Use
Medium-Voltage Switchgear Protecting outgoing feeders against overcurrent and short circuits
Industrial Distribution Networks Isolating faults in circuits supplying production equipment
Transformer Feeders Providing feeder protection on compatible transformer circuits
Industrial Substations Coordinating local protection with upstream devices
Motor Supply Feeders Protecting suitable motor circuits against configured current faults
Power Generation Auxiliary Systems Protecting distribution circuits supplying auxiliary equipment
Electrical Retrofit Projects Replacing an installed relay after verifying its complete configuration
Fault Investigation Reviewing recorded disturbance information after a protection event

The relay’s suitability depends on the protection functions available in the installed configuration. Directional protection, voltage-based functions, and other specialized applications should not be assumed unless they are supported by the specific hardware and configuration.


Installation and Maintenance

  1. Verify the complete model number: Confirm MRI4A0AB and check the installed hardware and order-code configuration.
  2. Review the protection design: Identify the protected feeder, grounding method, and required protection functions before making changes.
  3. Isolate the electrical circuit: Follow approved lockout and electrical safety procedures before handling the relay or its wiring.
  4. Check the mounting arrangement: Confirm that the installed housing and panel cutout match the replacement unit.
  5. Verify the auxiliary supply: Check the required supply range and terminal assignments for the exact configuration.
  6. Inspect current-transformer wiring: Verify CT ratios, polarity, phase assignment, and terminal connections against the circuit diagram.
  7. Check the earth-fault measurement circuit: Confirm the measurement method and wiring where earth-fault protection is used.
  8. Set the pickup thresholds: Select overcurrent and earth-fault thresholds according to the protected equipment and protection study.
  9. Coordinate the operating delays: Verify the selected definite-time or inverse-time characteristics against adjacent protective devices.
  10. Inspect output and trip wiring: Confirm that each assigned output is connected to the intended alarm or circuit-breaker trip circuit.
  11. Perform functional testing: Use approved test equipment to verify pickup behavior, timing, output operation, and the complete trip sequence.
  12. Record the final configuration: Document settings, CT details, output assignments, communication parameters, and test results.

Never open a current-transformer secondary circuit while primary current is flowing unless it has been made safe using an approved shorting and isolation arrangement. After changing protection settings, test the affected protection functions and confirm correct breaker operation before returning the feeder to service.


Compatible System Components

The MRI4A0AB operates within a wider electrical protection arrangement. The following component categories are relevant to its integration; exact ratings and compatibility must be established from the installed system design.

Component Function
Phase Current Transformers Supply current measurements for phase protection
Earth-Current Transformer or Summation Circuit Provides the measurement signal for earth-fault protection
Circuit Breaker Interrupts the protected feeder
Trip Coil Circuit Converts the relay output into a breaker operating action
Auxiliary Power Supply Provides the required relay operating power
Protection Test Equipment Supports secondary-injection and functional testing
Terminal Blocks Organize current, supply, and trip wiring
Communication Network Transfers supported data where the installed interface permits
Supervisory Control System Monitors available status and measurements
Electrical Switchgear Panel Houses the relay and associated protection equipment

Recommended Related Models

The following Woodward protection devices are related by product family or protection application. They are not confirmed direct replacements for MRI4A0AB; verify the required functions, current inputs, housing, and communication options before selecting an alternative.

Model Product Type Relevance
Woodward MRI4-2 Non-Directional Feeder Protection Relay Related MRI4 feeder protection variant
Woodward MRI4 Combined Non-Directional Overcurrent and Earth-Fault Relay Same protection relay family
Woodward MRA4-2 Directional Overcurrent and Earth-Fault Protection Relay Related protection family for applications requiring directional functions
Woodward MCA4-2 Directional Overcurrent and Earth-Fault Protection Relay Related HighPROTEC protection device
Woodward MRM4 Multifunctional Protection Relay Related relay family with broader protection capabilities
Woodward IRI1-I5E05D Time Overcurrent and Earth-Fault Relay Related current-based protection device

Key Advantages

  • Digital protection for electrical feeders.
  • Configurable overcurrent and short-circuit protection.
  • Supports earth-fault protection where configured.
  • Definite-time and inverse-time characteristics for protection coordination.
  • Disturbance recording capabilities within the MRI4 platform.
  • Integration with external trip circuits and compatible monitoring systems.

Technical FAQs

What is the main protection role of the MRI4A0AB?

The MRI4A0AB is used for feeder protection. Its principal role is to evaluate electrical measurements and initiate a trip when configured protection conditions, such as overcurrent or short circuit, are met. Earth-fault functions depend on the installed configuration.

How should the overcurrent timing characteristic be selected?

The choice between definite-time and inverse-time operation depends on the protected equipment, fault-current levels, and coordination with upstream and downstream devices. Settings should be established from the protection study rather than copied from another feeder.

What should be checked if the relay detects a fault but the circuit breaker does not open?

Check the assigned output, trip-circuit supply, wiring continuity, breaker trip coil, and any external interlocks. Secondary-injection testing can help establish whether the relay output operates correctly, while a separate trip-circuit test verifies the downstream switching path.

Can every MRI4 communication option be used with the MRI4A0AB?

No. Communication capabilities depend on the installed hardware and selected protocol option. Confirm the actual interface, protocol, and terminal arrangement before connecting the relay to a PLC, SCADA system, or substation communication network.