• Ingersoll Rand 47555210001 99289894 Minimum Pressure Check Valve Repair Kit
  • Ingersoll Rand 47555210001 99289894 Minimum Pressure Check Valve Repair Kit
  • Ingersoll Rand 47555210001 99289894 Minimum Pressure Check Valve Repair Kit
  • Ingersoll Rand 47555210001 99289894 Minimum Pressure Check Valve Repair Kit
Product Overview The Ingersoll Rand 47555210001 99289894 Minimum Pressure Check Valve Repair Kit is a service kit for the minimum pressure valve assembly in compatible rotary screw air compressors. The ……
Ingersoll Rand 47555210001 99289894 Minimum Pressure Check Valve Repair Kit
  • Ingersoll Rand
  • 47555210001 99289894
  • Minimum Pressure Check Valve Repair Kit
  • USA
  • 84 × 84 × 202 mm
  • 1.41 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 7

Our advantage

Ingersoll Rand 47555210001 99289894 Minimum Pressure Check Valve Repair Kit

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Ingersoll Rand 47555210001 99289894 Minimum Pressure Check Valve Repair Kit

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Ingersoll Rand 47555210001 99289894 Minimum Pressure Check Valve Repair Kit

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Ingersoll Rand 47555210001 99289894 Minimum Pressure Check Valve Repair Kit

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Ingersoll Rand 47555210001 99289894 Minimum Pressure Check Valve Repair Kit is a service kit for the minimum pressure valve assembly in compatible rotary screw air compressors. The minimum pressure valve helps maintain the required pressure inside the compressor system during startup and operation, supporting proper oil circulation and the operation of the air-oil separation system in oil-injected compressor designs.

During compressor startup, the minimum pressure valve helps prevent the system pressure from remaining too low for the intended operating conditions. Once the required pressure is established, the valve regulates the flow of compressed air toward the downstream air network. Its check-valve function also helps limit reverse airflow when downstream pressure exceeds the pressure available from the compressor.

Over time, valve sealing surfaces and internal moving components can wear, accumulate deposits, or lose their ability to operate correctly. A repair kit provides replacement components for servicing the valve assembly without automatically requiring replacement of the complete valve unit.

The 99289894 kit is particularly relevant when maintenance personnel identify problems associated with minimum pressure regulation or reverse-flow prevention. Depending on the actual fault, these problems may present as slow pressure buildup, abnormal pressure behavior during unloading, or difficulty maintaining the expected operating conditions. Such symptoms can also result from other compressor faults, so the valve assembly should be inspected before replacement parts are installed.

Correct kit selection is essential because minimum pressure valve assemblies differ across compressor models and configurations. The complete part number should be matched to the installed equipment before maintenance begins.


Technical Specifications

Parameter Specification
Manufacturer Ingersoll Rand
Part Number 99289894
Associated Product Reference 47555210001
Product Type Minimum Pressure Check Valve Repair Kit
Component Category Compressor Valve Service Kit
Primary Application Minimum pressure valve assembly maintenance
Equipment Type Compatible rotary screw air compressors
Main Function Restoration of minimum pressure valve and check-valve operation
Operating System Compressed-air and compressor pressure-control circuit
Service Method Repair of the existing compatible valve assembly
Dimensions 84 × 84 × 202 mm
Weight 1.41 kg

Product Features

  • Minimum pressure valve servicing: Supports maintenance of the valve assembly responsible for maintaining the required compressor-side pressure.
  • Check-valve function restoration: Helps restore the intended prevention of reverse airflow when the relevant internal components are worn or damaged.
  • Targeted component replacement: Allows specified valve components to be serviced without automatically replacing the complete assembly.
  • Compressed-air system maintenance: Supports the pressure-control arrangement in compatible oil-injected rotary screw compressors.
  • Pressure regulation support: Helps restore the valve’s intended operating behavior when the fault is attributable to serviceable internal components.
  • Part-number identification: Provides a specific replacement reference for maintenance planning and spare-parts inventory.
  • Planned and corrective maintenance: Can be used during scheduled servicing or when inspection identifies a fault in the compatible minimum pressure valve assembly.

Working Principle

The minimum pressure valve operates within the compressor’s air and oil separation system. It helps maintain a minimum internal pressure before compressed air is delivered to the downstream system. This pressure is important in oil-injected rotary screw compressors because the internal pressure conditions support the intended circulation and separation processes.

A simplified airflow arrangement is:

Compressor Airend → Air-Oil Separator Vessel → Minimum Pressure Check Valve → Aftercooler → Compressed-Air Network

The exact arrangement varies by compressor design. During startup, the valve restricts downstream air delivery until the required pressure conditions are established. As pressure develops, the valve opens according to its operating characteristics and permits compressed air to flow toward the outlet.

The check-valve function helps prevent downstream air from flowing backward into the compressor when the pressure conditions change. This is particularly relevant during unloading or shutdown, when the pressure on the outlet side may differ from the pressure inside the compressor system.

The 99289894 repair kit supports the restoration of this valve function by supplying the specified service components for the compatible assembly. Depending on the kit’s actual contents, the maintenance procedure may involve replacing worn sealing or internal valve components. The exact component list and assembly procedure must correspond to the valve design being serviced.

After the repair, the valve should be checked for correct operation within the compressor’s normal operating sequence. Pressure buildup, unloading behavior, leakage, and downstream air delivery can provide useful diagnostic information. Abnormal behavior should not automatically be attributed to the minimum pressure valve because separator restriction, control faults, leakage, and other pressure-system problems can produce similar symptoms.


Role in the Compressor Pressure-Control System

The 99289894 repair kit supports the maintenance of a component that influences internal compressor pressure and the direction of compressed-air flow. The kit itself does not regulate pressure; that function is performed by the repaired valve assembly.

Compressor Airend → Separator Vessel → Minimum Pressure Check Valve → Air Treatment Equipment → Plant Air Network

System Component Function
Compressor Airend Compresses incoming air
Air-Oil Separator Vessel Separates oil from compressed air in applicable oil-injected designs
Minimum Pressure Check Valve Helps maintain the required internal pressure and limits reverse airflow
99289894 Repair Kit Supplies specified service components for the compatible valve assembly
Aftercooler Reduces compressed-air temperature downstream of the compression stage
Air Receiver Stores compressed air and helps accommodate demand fluctuations
Downstream Air Network Distributes compressed air to production equipment
Compressor Controller Manages operating sequences and monitors supported operating conditions
Pressure Sensors and Switches Provide pressure information for control and monitoring where fitted

The repair should be assessed as part of the complete compressor pressure system. Restoring the valve does not correct unrelated faults in the separator, control circuit, pressure sensors, or downstream air network.


Industrial Applications

Application Typical Use
Industrial Rotary Screw Compressors Servicing the minimum pressure valve assembly
Manufacturing Plants Maintaining compressor pressure regulation in production air systems
Automotive Production Supporting compressed-air equipment used by assembly and pneumatic tools
Packaging Facilities Maintaining pressure-control components in compressor installations
Metalworking Workshops Servicing compressor valves supplying pneumatic machinery
Process-Air Installations Maintaining the intended pressure behavior of compatible compressor systems
Centralized Compressor Rooms Supporting corrective maintenance on shared compressed-air equipment
Industrial Utilities Restoring valve operation following inspection and fault diagnosis
Compressor Overhaul Work Replacing specified internal valve components during planned maintenance
Preventive Maintenance Programs Keeping compatible minimum pressure valve assemblies serviceable

Installation and Maintenance

  1. Verify the repair kit reference: Confirm part number 99289894 and identify the installed minimum pressure valve before beginning the repair.
  2. Identify the compressor configuration: Check the compressor model and the applicable parts arrangement to ensure that the kit matches the installed valve assembly.
  3. Diagnose the pressure problem: Review startup pressure buildup, unloading behavior, leakage, and other operating symptoms before deciding that the minimum pressure valve requires repair.
  4. Shut down the compressor: Stop the machine using the approved shutdown procedure and prevent an unexpected restart during maintenance.
  5. Isolate and depressurize the system: Disconnect the required energy sources and verify that the relevant pressure-containing sections are safely depressurized before dismantling the valve.
  6. Inspect the valve assembly: Examine accessible sealing surfaces, internal moving components, and the valve housing for wear, contamination, corrosion, or mechanical damage.
  7. Check the kit contents: Compare the supplied service components with the valve’s maintenance requirements before removing the original parts.
  8. Clean the service area: Prevent dirt and loose debris from entering the compressor’s air, oil, or pressure-control passages during disassembly.
  9. Replace the specified components: Follow the applicable assembly procedure and use the correct installation orientation, sealing method, and tightening requirements.
  10. Inspect related pressure-system components: Check associated connections and accessible components for leakage or damage that could affect valve operation.
  11. Verify operation after reassembly: Restore the compressor according to the approved procedure and check pressure buildup, unloading behavior, air delivery, and leakage.
  12. Record the maintenance results: Document the kit part number, compressor operating hours, replaced components, observed fault, and post-repair test results.

Compatible System Components

Component Function
Compatible Ingersoll Rand Rotary Screw Compressor Provides the compressor platform for the specified valve repair
Minimum Pressure Check Valve Assembly Regulates the minimum pressure and limits reverse airflow
Air-Oil Separator Vessel Supports oil separation in applicable compressor designs
Separator Element Removes entrained oil from compressed air
Compressor Pressure Sensors Provide pressure measurements for supported control functions
Compressor Controller Manages operating sequences and monitors operating conditions
Aftercooler Reduces compressed-air temperature
Air Receiver Stores compressed air for the downstream system
Pressure Piping and Connections Carry compressed air between the compressor and plant network

Recommended Related Models

Model / Part Number Product Type Main Application
Ingersoll Rand 99289894 Minimum Pressure Valve Repair Kit Repairing the compatible minimum pressure valve assembly
Ingersoll Rand 22064695 Minimum Pressure Valve Repair Kit Related compressor valve service reference; verify the specific equipment application
Ingersoll Rand 23531577 Minimum Pressure Valve Repair Kit Servicing compatible minimum pressure valve assemblies
Ingersoll Rand 47740158001 Minimum Pressure Valve Repair Kit Valve repair application for selected GDK15–22 compressors
Ingersoll Rand 47723684001 Minimum Pressure Valve Repair Kit Related minimum pressure valve service part for compatible equipment
Ingersoll Rand 47550032 Intake Valve Repair Kit Related compressor valve maintenance component for selected HAKG120 equipment

Key Advantages

  • Supports repair of a compatible minimum pressure check valve without automatically replacing the complete valve assembly.
  • Helps restore the intended pressure regulation and reverse-flow prevention functions when worn internal components are responsible for the fault.
  • Provides a defined part number for maintenance planning and spare-parts identification.
  • Supports corrective maintenance following pressure-system diagnosis.
  • Helps maintain the operating condition of compatible rotary screw compressor installations.

Technical FAQs

What is the difference between a minimum pressure valve and a minimum pressure check valve?

The terms are often used for the same combined valve assembly in rotary screw compressors. The minimum pressure function helps maintain the required internal pressure, while the check-valve function restricts reverse airflow. The exact arrangement depends on the compressor design.

What compressor symptoms may indicate a problem with the minimum pressure valve?

Possible symptoms include abnormal pressure buildup, unexpected pressure loss, unusual unloading behavior, or reverse airflow under conditions where the valve should prevent it. These symptoms are not conclusive on their own; the separator, control system, pressure sensing, and other related components should also be evaluated.

Does the 99289894 kit replace the complete minimum pressure valve?

The product is identified as a repair kit rather than a complete valve assembly. It is intended to support servicing of the compatible valve, using the components specified for that assembly. The kit contents should be checked before maintenance to establish the exact repair scope.

What should be checked before returning the compressor to service after the repair?

Confirm that the valve has been reassembled correctly, all connections are secure, and the relevant pressure sections have been restored according to the service procedure. During the operational check, observe pressure buildup, unloading behavior, air delivery, and any signs of leakage.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501