• ABB TA562-RS-RTC 1SAP181500R0001 RS485 Serial Adapter with Real-Time Clock
  • ABB TA562-RS-RTC 1SAP181500R0001 RS485 Serial Adapter with Real-Time Clock
  • ABB TA562-RS-RTC 1SAP181500R0001 RS485 Serial Adapter with Real-Time Clock
  • ABB TA562-RS-RTC 1SAP181500R0001 RS485 Serial Adapter with Real-Time Clock
Product Overview The ABB TA562-RS-RTC, ordering number 1SAP181500R0001, is an option board for compatible ABB AC500-eCo V2 programmable logic controllers. It combines a COM2 RS-485 serial interface with……
ABB TA562-RS-RTC 1SAP181500R0001 RS485 Serial Adapter with Real-Time Clock
  • ABB
  • TA562-RS-RTC 1SAP181500R0001
  • Serial Adapter
  • Sweden (SE)
  • 170 × 10 × 100 mm
  • 0.013 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 10

Our advantage

ABB TA562-RS-RTC 1SAP181500R0001 RS485 Serial Adapter with Real-Time Clock

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

ABB TA562-RS-RTC 1SAP181500R0001 RS485 Serial Adapter with Real-Time Clock

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

ABB TA562-RS-RTC 1SAP181500R0001 RS485 Serial Adapter with Real-Time Clock

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

ABB TA562-RS-RTC 1SAP181500R0001 RS485 Serial Adapter with Real-Time Clock

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The ABB TA562-RS-RTC, ordering number 1SAP181500R0001, is an option board for compatible ABB AC500-eCo V2 programmable logic controllers. It combines a COM2 RS-485 serial interface with a real-time clock function in a single accessory, allowing supported PLC configurations to add serial communication and clock functionality together. <Cite refs={[“turn809929search4″,”turn809929search12”]}/>

In a machine control panel, the serial interface can be used to exchange data with compatible instruments, operator panels, or other serial devices. The integrated real-time clock is useful when the PLC application needs to associate events or process data with date and time information. For example, a controller can communicate with a serial instrument while recording time-related operating events in its application, provided the processor and program support the required functions.

The TA562-RS-RTC differs from the TA562-RS, which adds the COM2 serial interface without the combined clock function. It also differs from the TA569-RS-ISO, which provides galvanic isolation for the serial interface. These variants should not be treated as interchangeable without checking the required functions and processor compatibility.

Before selecting this adapter, confirm the exact CPU model, option-board interface, and serial communication requirements. The real-time clock also depends on the applicable battery arrangement and controller configuration, so the complete installation requirements should be checked during commissioning.


Technical Specifications

Parameter Specification
Manufacturer ABB
Model TA562-RS-RTC
Ordering Number 1SAP181500R0001
Product Type RS485 Serial Adapter with Real-Time Clock
Product Family ABB AC500-eCo V2
Communication Interface RS-485
Serial Port COM2
Additional Function Real-Time Clock
Connector Pluggable screw terminal block
Battery CR2032, purchased separately where required
Dimensions 170 × 10 × 100 mm
Weight 0.013 kg

Product Features

  • Combined serial and clock functions: Integrates a COM2 RS-485 interface and real-time clock in one option board.
  • COM2 communication: Supports serial data exchange with compatible external equipment.
  • Date and time information: Allows supported PLC applications to use clock data for time-based operations and event records.
  • Pluggable screw terminal block: Provides the designated connection for the serial interface.
  • AC500-eCo V2 integration: Belongs to the accessory range for compatible processor hardware.
  • Separate battery provision: The specified CR2032 battery must be accounted for where required by the clock’s backup arrangement.
  • Distinct accessory identification: The TA562-RS-RTC designation distinguishes the combined-function board from the serial-only TA562-RS.

Working Principle

The TA562-RS-RTC combines two functions that serve different purposes within a PLC system. Its RS-485 interface carries serial data between the processor and a compatible external device, while the real-time clock supplies date and time information for applications that require time-based processing.

The communication path is:

AC500-eCo Processor → TA562-RS-RTC COM2 → RS-485 Network → External Serial Device

RS-485 uses differential signaling over a pair of conductors. The PLC application determines the protocol and how received or transmitted data is handled. If the connection uses Modbus RTU, for example, the PLC and external device must share compatible baud rate, parity, data format, and addressing settings.

The clock function operates separately from serial data transmission. It provides time information that a supported PLC application can use when recording events, scheduling operations, or tracking process changes. Clock retention during loss of controller power depends on the supported backup arrangement and battery condition.

During commissioning, both functions should be checked independently. A working serial connection does not establish that the clock is correctly set, and correct clock operation does not confirm that the RS-485 network is configured properly. The application should be tested for communication response, valid date and time values, and correct handling of power interruption.


Role in the AC500-eCo PLC Architecture

The TA562-RS-RTC extends the processor’s communication and timekeeping capabilities. The CPU continues to execute the PLC program, while the option board supplies the additional serial interface and real-time clock function.

System Element Function
ABB AC500-eCo Processor Executes PLC logic and manages application functions
TA562-RS-RTC Adds the COM2 RS-485 interface and real-time clock
RS-485 Cable Carries serial communication signals
External Serial Device Exchanges data with the PLC through the configured protocol
PLC Communication Program Handles serial data and protocol processing
Real-Time Clock Supplies date and time information to supported application functions
CR2032 Battery Provides clock backup where required by the hardware arrangement
Engineering Software Supports PLC programming, configuration, and diagnostics

Industrial Applications

Application Practical Use
Machine Automation Combining serial device communication with time-based application functions
Packaging Equipment Communicating with compatible serial devices while recording process events
Pump Control Systems Supporting serial data exchange and time-related operating records
Building Automation Connecting supported serial equipment in applications that use date and time information
Industrial Instrumentation Reading data from compatible RS-485 instruments
Modbus RTU Networks Supporting protocol-based communication when configured in the PLC application
Event Logging Associating operating events with date and time information
Equipment Maintenance Replacing a combined serial and clock option board in a compatible controller

Installation and Maintenance

  1. Verify the complete part number: Confirm TA562-RS-RTC and ordering number 1SAP181500R0001 against the existing accessory and processor documentation.
  2. Check processor compatibility: Identify the exact AC500-eCo processor model and hardware generation before installing the option board.
  3. Isolate the controller: Follow the processor’s shutdown procedure and disconnect the required power before installing or removing the accessory.
  4. Inspect the option-board interface: Check the designated connection for contamination, damaged contacts, or mechanical obstruction.
  5. Install the board correctly: Align the TA562-RS-RTC with the appropriate interface and seat it according to the processor’s installation instructions.
  6. Check the battery requirement: Verify whether a CR2032 battery is required for the installed configuration and confirm that it is correctly fitted and in serviceable condition.
  7. Inspect the serial terminal block: Check the terminal block and conductors for loose connections, damaged insulation, or incorrect wiring.
  8. Verify RS-485 wiring: Confirm the signal connections, cable arrangement, and any required termination or biasing for the communication network.
  9. Configure the protocol: Match the PLC and external device settings, including baud rate, parity, data format, and device address where applicable.
  10. Set and verify the clock: Confirm that the date and time are correct and check the clock’s behavior after the relevant power-cycle test.
  11. Test communication and timekeeping separately: Verify serial data exchange, then confirm that the application reads valid clock values and uses them as intended.
  12. Record the configuration: Document the board ordering number, processor model, battery status, communication settings, and commissioning results.

Compatible System Components

Component Function
ABB AC500-eCo V2 Processor Hosts the combined serial and clock option in supported configurations
RS-485 Cable Carries serial communication signals
Pluggable Screw Terminal Block Provides the designated serial connection
Compatible Serial Instrument Exchanges process data with the PLC
Operator Panel Supports operator commands and status exchange through a compatible protocol
CR2032 Battery Supports clock backup where required
RS-485 Termination Components Meet the electrical requirements of the serial network
PLC Engineering Software Supports application configuration and diagnostics

Recommended Related Models

Model Product Type Selection Consideration
ABB TA562-RS-RTC / 1SAP181500R0001 RS485 Serial Adapter with Real-Time Clock Reference model combining COM2 and clock functionality
ABB TA562-RS / 1TNE968901R4300 AC500-eCo RS485 Serial Adapter Provides COM2 serial communication without the combined clock function
ABB TA561-RTC / 1SAP181400R0001 Real-Time Clock Option Board Clock-related accessory without the combined COM2 function
ABB TA569-RS-ISO / 1SAP186400R0001 Isolated RS485 Serial Adapter Alternative for supported configurations requiring galvanic isolation
ABB TK503 / 1TNE968901R1100 USB-to-RS485 Programming Cable Programming connection for supported COM1 arrangements
ABB TK504 / 1TNE968901R2100 USB-to-RS485 Programming Cable Programming connection for supported COM2 arrangements
ABB TK506 / 1SAP186100R0001 RS485 Isolator Provides isolation for supported COM1 serial connections
ABB TA570 / 1TNE968901R3203 AC500-eCo Accessory Set Includes specified covers and terminal accessories
ABB PM55x-xP AC500-eCo Processor Family Check processor compatibility with the option board
ABB PM56x-xP AC500-eCo Processor Family Check processor compatibility and available option interfaces
ABB AC500-eCo V2 PLC Product Family Relevant controller family for the TA562-RS-RTC accessory

Key Advantages

  • Combines COM2 RS-485 communication and a real-time clock.
  • Supports time-based application functions alongside serial data exchange.
  • Uses a pluggable screw terminal block for the serial connection.
  • Has a distinct ordering number for replacement identification.
  • Reduces the need to select separate serial and clock accessories where the combined board is supported.

Technical FAQs

What is the difference between the TA562-RS and TA562-RS-RTC?

The TA562-RS provides the COM2 RS-485 interface. The TA562-RS-RTC combines the same general serial-interface function with a real-time clock, so the latter is appropriate when both functions are required and supported by the processor.

Does the TA562-RS-RTC require a separate battery?

The associated documentation identifies a CR2032 battery as a separate item for the clock backup arrangement. Check the installed hardware and its battery requirements before commissioning.

Can the COM2 interface communicate with Modbus RTU devices?

It can be used in a compatible Modbus RTU arrangement when the PLC application and external device support the protocol. Communication parameters, addressing, and RS-485 wiring must be configured consistently.

What should be checked if the clock resets after the controller is switched off?

Check the battery requirement, battery condition, installation, and the processor’s supported clock-backup arrangement. Also verify that the PLC application sets or reads the clock correctly after power is restored.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501