The Allen-Bradley 20G1AJC770AN0NNNNN is a high-power PowerFlex 755 air-cooled AC drive designed for large industrial motor-control applications.
It belongs to the PowerFlex 755 series and is configured for a 400 VAC, three-phase electrical system. The drive provides a nominal continuous output current of 770 A, with application ratings of 450 kW Light Duty, 400 kW Normal Duty, and 355 kW Heavy Duty. It uses a large Frame 8 construction and an 800 mm deep MCC-style enclosure with Type 12 / IP54 protection.
The 20G1AJC770AN0NNNNN is intended for installations where a conventional compact inverter is not sufficient because of motor size, output current, mechanical load, process requirements, or the need for a large integrated industrial drive system.
It is particularly well suited to large pumps, fans, blowers, conveyors, water and wastewater equipment, mining machinery, process equipment, material-handling systems, industrial HVAC, and other large rotating machines.
The model incorporates embedded EtherNet/IP, allowing the drive to participate in a modern industrial automation architecture. The drive is also configured with an EMC filter, while the catalog configuration specifies the common-mode capacitor jumper as removed. It uses AC input with precharge and no DC input terminals, and the standard configuration has no dynamic braking.
An important catalog-status point should also be noted: 20G1AJC770AN0NNNNN is a discontinued configuration. The listed direct replacement is 20G1AJC770JN0NNNNN. The major distinction between the AN0 and JN0 configurations is the filtering/common-mode jumper configuration, so replacement engineering should not be performed solely by matching the output current.
| Item | Specification |
|---|---|
| Brand | Allen-Bradley |
| Product Family | PowerFlex |
| Product Series | PowerFlex 755 |
| Product Type | High-Power Air-Cooled AC Drive |
| Catalog Number | 20G1AJC770AN0NNNNN |
| Drive Category | Variable Frequency AC Drive |
| Construction | Floor-Standing / MCC Style |
| Frame | Frame 8 |
| Cooling | Forced Air |
| Input Voltage Class | 400 VAC |
| Input Phase | 3 Phase |
| Output Current | 770 A |
| Enclosure | Type 12 |
| Ingress Protection | IP54 |
| MCC Style Depth | 800 mm |
| Communications | Embedded EtherNet/IP |
| Dynamic Braking | None |
| Input Configuration | AC Input with Precharge |
| DC Input Terminals | None |
| EMC Filtering | Filtered |
| CM Jumper | Removed |
| HIM | Blank / No HIM |
| Lifecycle | Discontinued |
| Direct Replacement | 20G1AJC770JN0NNNNN |
The PowerFlex 755 series is positioned toward larger industrial motor applications where higher current capacity, advanced control, communications, diagnostics, and integration into plant automation systems are required.
Within the 400 VAC class, the 770 A configuration is one of the largest Frame 8 options before moving into higher-current Frame 9 and larger configurations. The published selection data identify the 770 A model as a Frame 8 drive with 450 kW Light Duty, 400 kW Normal Duty, and 355 kW Heavy Duty capability.
| Parameter | Specification |
|---|---|
| Model / Catalog Number | 20G1AJC770AN0NNNNN |
| Brand | Allen-Bradley |
| Series | PowerFlex 755 |
| Product Type | Air-Cooled AC Drive |
| Input Voltage | 380–400 VAC class / 400 VAC nominal |
| Input Phase | Three Phase |
| Rated Output Current | 770 A |
| Light-Duty Power | 450 kW |
| Normal-Duty Power | 400 kW |
| Heavy-Duty Power | 355 kW |
| Light-Duty Continuous Current | 770 A |
| Light-Duty 1-Minute Current | 847 A |
| Light-Duty 3-Second Current | 1,155 A |
| Normal-Duty Continuous Current | 642 A |
| Normal-Duty 1-Minute Current | 963 A |
| Normal-Duty 3-Second Current | 1,155 A |
| Heavy-Duty Continuous Current | 585 A |
| Heavy-Duty 1-Minute Current | 878 A |
| Heavy-Duty 3-Second Current | 1,125 A |
| Frame Size | Frame 8 |
| Cooling | Forced Air |
| Enclosure | Type 12 |
| Protection | IP54 |
| MCC Style | 800 mm Deep |
| Input Type | AC Input with Precharge |
| DC Terminals | None |
| EMC Filter | Yes |
| Common-Mode Jumper | Removed |
| Dynamic Braking | None |
| Communications | Embedded EtherNet/IP |
| HIM | Blank / No HIM |
| Installation Style | Floor-Standing / MCC Style |
| Approx. Width | Approximately 600 mm class* |
| Approx. Height | Approximately 2,000–2,200 mm class* |
| Approx. Depth | Approximately 800 mm* |
| Approx. Weight | Approximately 500–700 kg* |
The published electrical selection data show 832 A Light-Duty one-minute current and 915 A three-second current, 770 A continuous Light-Duty current, 642 A continuous Normal-Duty current, and 585 A continuous Heavy-Duty current. The corresponding power ratings are 450 kW, 400 kW, and 355 kW respectively.
*The 800 mm depth is associated with the MCC-style configuration. Width, height, and complete assembled/shipping weight should be treated as preliminary planning values, not certified mechanical dimensions. For final equipment-room layout, lifting arrangements, floor loading, transportation, and cabinet installation, the exact mechanical drawing for the configured unit should be used.
The 20G1AJC770AN0NNNNN is designed for the 380–400 VAC / 400 VAC class, three-phase industrial power system.
This voltage class is widely used for large industrial motors and process equipment.
The three-phase configuration is appropriate for high-power AC motors because it provides the electrical structure required for large motor loads while allowing the drive to regulate motor speed and torque electronically.
The most distinctive characteristic of this model is its 770 A output-current class.
A 770 A drive belongs to the high-power end of conventional low-voltage AC motor drives.
This makes it suitable for motors and machines that would be beyond the practical range of smaller Frame 6 or Frame 7 drives.
The high current rating is particularly useful for applications involving:
One of the most important aspects of this model is the distinction between Light Duty, Normal Duty, and Heavy Duty.
| Duty Type | Continuous Current | 1-Minute Current | 3-Second Current | Power Rating |
|---|---|---|---|---|
| Light Duty | 770 A | 847 A | 1,155 A | 450 kW |
| Normal Duty | 642 A | 963 A | 1,155 A | 400 kW |
| Heavy Duty | 585 A | 878 A | 1,125 A | 355 kW |
These ratings show why selecting a drive solely according to the motor’s nameplate kW can be misleading.
A 400 kW motor, for example, may be an appropriate Normal-Duty application, but the same drive should not automatically be assumed to provide the same rating for a demanding Heavy-Duty application.
Heavy-duty machinery can require greater current during acceleration and operation.
Examples include:
Therefore, the actual motor current, torque requirement, acceleration profile, load inertia, and duty cycle should all be evaluated during drive selection.
The 20G1AJC770AN0NNNNN uses Frame 8 construction.
This is a large industrial drive frame.
Frame 8 is not intended to be treated like a small wall-mounted inverter.
The equipment should normally be considered part of a floor-standing electrical installation.
The large frame provides the physical space necessary for high-current power components, cooling equipment, electrical connections, protection equipment, and associated control hardware.
The Frame 8 construction also has implications for:
The drive uses an 800 mm deep MCC-style configuration.
This is particularly useful for large industrial electrical installations where the drive is integrated into a larger motor-control arrangement.
The 800 mm depth should be considered when designing:
The depth is not simply a catalog dimension.
For a large 770 A drive, adequate space is required for power cables, ventilation, maintenance access, equipment handling, and safe working conditions.
Physical dimensions and weight are particularly important for this model because it is a large Frame 8 packaged drive.
| Mechanical Parameter | Approximate Value / Planning Reference |
|---|---|
| Model | 20G1AJC770AN0NNNNN |
| Frame | Frame 8 |
| Enclosure | Type 12 / IP54 |
| MCC Depth | 800 mm |
| Approx. Width | ~600 mm class |
| Approx. Height | ~2,000–2,200 mm |
| Approx. Depth | ~800 mm |
| Approx. Complete Weight | ~500–700 kg |
| Installation | Floor Standing |
| Cooling | Forced Air |
| Handling | Heavy Equipment Handling |
| Service Requirement | Adequate front/service clearance |
The 800 mm depth is the strongest published mechanical reference for this configuration.
The width and height above are practical planning ranges for a large Frame 8 MCC-style package, while the 500–700 kg weight range should be regarded as a preliminary equipment-planning estimate.
The final shipping weight can vary according to the exact cabinet arrangement, internal equipment, options, accessories, and packaging.
For a project involving lifting equipment, floor reinforcement, transportation, seismic calculations, or structural loading, the final configured mechanical documentation should take precedence.
The 20G1AJC770AN0NNNNN is an air-cooled drive using forced-air cooling.
At 770 A, thermal management is a major engineering consideration.
The drive converts electrical power to motor power while inevitably generating heat within its power electronics.
The cooling system is therefore an integral part of reliable operation.
The installation should provide appropriate:
Potential cooling problems can arise from:
For large industrial installations, the heat generated by multiple drives should be considered when designing the overall electrical room.
The 20G1AJC770AN0NNNNN is configured as Type 12 / IP54.
This provides a substantially more protected installation format than an open-frame drive.
The enclosure is suitable for many industrial electrical-room environments where protection from dust and general industrial contamination is important.
However, Type 12 / IP54 protection should not be interpreted as making the drive suitable for every outdoor or washdown environment.
Application-specific environmental conditions should always be reviewed, including:
The drive includes embedded EtherNet/IP.
This is an important feature for industrial automation applications.
A large motor drive frequently needs to exchange information with a PLC, HMI, supervisory control system, process controller, or plant network.
Using embedded EtherNet/IP allows the drive to become an integrated part of the control architecture.
Typical information exchanged can include:
For large installations containing many drives, network communications can substantially reduce the amount of conventional hardwired control wiring.
The catalog configuration specifies an EMC filter.
The filter is relevant in industrial environments where electromagnetic compatibility must be considered.
AC drives use high-frequency switching techniques to generate the required motor voltage waveform.
This switching behavior is essential to drive operation but can also introduce electrical noise.
A properly configured filtering and grounding system can help manage conducted and radiated electrical interference.
However, the filter alone is not a complete EMC solution.
The complete installation should also consider:
The AN0 configuration indicates that the common-mode capacitor jumper is removed.
This is an important catalog-level distinction.
The related JN0 replacement configuration uses the installed jumper arrangement.
Therefore, when replacing an AN0 drive with a JN0 drive, the engineering team should not simply exchange the units without reviewing the applicable installation and grounding requirements.
The electrical system, motor insulation, grounding arrangement, EMC requirements, and drive configuration should be checked as part of the replacement process.
The 20G1AJC770AN0NNNNN is specified with no dynamic braking.
This is an important consideration for machines that must decelerate rapidly.
During motor deceleration, energy from a rotating load can return toward the drive.
Applications involving large inertia may therefore require additional braking or regenerative-energy management depending on the required stopping profile.
Examples include:
Before using this drive on such equipment, the complete stopping strategy should be evaluated.
The AN0 configuration is supplied with a Blank / No HIM arrangement.
This means that the catalog configuration does not include the enhanced LCD full-numeric local operator interface associated with the JN4 configuration.
This distinction is important when comparing:
20G1AJC770AN0NNNNN
with:
20G1AJC770AN4NNNNN
or:
20G1AJC770JN4NNNNN
The drive itself may be part of the same broad electrical family, but the operator-interface configuration is different.
For installations where technicians need frequent local access to drive parameters, diagnostics, and operating information, the appropriate HIM configuration should be considered during selection.
Large water pumps are one of the strongest application areas for a drive in the 770 A class.
A variable-speed drive can adjust pump speed according to process requirements.
Typical applications include:
Large wastewater facilities use many high-power motors.
Potential applications include:
The high output-current capacity of the 20G1AJC770AN0NNNNN makes it suitable for large motor installations where smaller drives would not provide adequate capacity.
Industrial fans can consume substantial motor power.
The drive can be used for:
Variable-speed control allows airflow to be adjusted to the process requirement.
Large blowers are another natural application.
Potential systems include:
Large conveyors frequently require high motor power.
A VFD can provide controlled acceleration and deceleration.
This can help reduce mechanical shock on:
For long conveyors, controlled speed operation can also provide better coordination with upstream and downstream equipment.
Mining equipment often combines high motor power with demanding mechanical conditions.
Potential applications include:
Cement plants contain many large rotating machines.
The drive can be considered for:
Large industrial HVAC installations can contain motors requiring hundreds of kilowatts.
Potential applications include:
The 20G1AJC770AN0NNNNN can also be considered for large rotating equipment used in:
The 770 A output rating is the primary advantage of this model.
It provides a substantial current margin for large industrial motors and places the drive in a high-power category.
For applications where a 650 A or 750 A drive is close to the required motor current, the 770 A configuration can provide additional capacity.
The drive provides a 355 kW Heavy-Duty rating.
This is particularly valuable when compared with the 750 A model, which has a 315 kW Heavy-Duty rating.
Therefore, the 770 A model is not simply a small current increase over the 750 A version.
It also provides a meaningful increase in Heavy-Duty capability.
The 400 kW Normal-Duty rating makes this model suitable for many large industrial motor applications.
It is particularly attractive for large pumps, fans, blowers, and other variable-speed loads.
The 450 kW Light-Duty rating provides an even higher capacity for applications with less demanding overload requirements.
This makes the drive suitable for large variable-torque loads where the duty profile is appropriate.
Embedded EtherNet/IP makes the drive well suited to modern plant automation.
The drive can exchange operational and diagnostic information with the broader control system without relying exclusively on hardwired control signals.
The 800 mm deep MCC-style arrangement is appropriate for centralized industrial electrical systems.
This is especially useful for projects where multiple high-power drives are installed in organized electrical lineups.
The enclosed construction provides protection suitable for many industrial electrical-room environments.
It is more appropriate for dusty industrial environments than an open-frame drive, assuming the environmental conditions remain within the intended application range.
Forced-air cooling allows the drive to handle the substantial thermal load associated with its high-current power electronics.
For large industrial installations, this also makes ventilation and fan maintenance important parts of the maintenance program.
The 770 A configuration can cover a wide range of large industrial machines.
Its application range extends from pumps and fans to conveyors, mining equipment, blowers, process machinery, and industrial utility systems.
The following five models are particularly relevant when comparing the 20G1AJC770AN0NNNNN with nearby 400 VAC PowerFlex 755 configurations.
| Model | Input | Current | Light Duty | Normal Duty | Heavy Duty | Frame | Enclosure | Cooling |
|---|---|---|---|---|---|---|---|---|
| 20G1AJC460AN0NNNNN | 400 VAC, 3 PH | 460 A | 315 kW | 250 kW | 200 kW | 8 | Type 12 / IP54 | Forced Air |
| 20G1AJC540AN0NNNNN | 400 VAC, 3 PH | 540 A | 315 kW | 315 kW | 250 kW | 8 | Type 12 / IP54 | Forced Air |
| 20G1AJC567AN0NNNNN | 400 VAC, 3 PH | 567 A | 355 kW | 315 kW | 250 kW | 8 | Type 12 / IP54 | Forced Air |
| 20G1AJC650AN0NNNNN | 400 VAC, 3 PH | 650 A | 400 kW | 355 kW | 315 kW | 8 | Type 12 / IP54 | Forced Air |
| 20G1AJC750AN0NNNNN | 400 VAC, 3 PH | 750 A | 450 kW | 400 kW | 315 kW | 8 | Type 12 / IP54 | Forced Air |
These models form a useful current-capacity progression from 460 A through 770 A.
The published selection data identify the 460 A, 540 A, 567 A, 650 A, 750 A, and 770 A models as Frame 8 configurations in the 380–400 VAC class.
| Model | Output Current | LD | ND | HD | Best Selection Position |
|---|---|---|---|---|---|
| 20G1AJC460AN0NNNNN | 460 A | 315 kW | 250 kW | 200 kW | Lower-capacity Frame 8 application |
| 20G1AJC540AN0NNNNN | 540 A | 315 kW | 315 kW | 250 kW | General high-power application |
| 20G1AJC567AN0NNNNN | 567 A | 355 kW | 315 kW | 250 kW | Higher Light-Duty requirement |
| 20G1AJC650AN0NNNNN | 650 A | 400 kW | 355 kW | 315 kW | Higher Normal/Heavy-Duty requirement |
| 20G1AJC750AN0NNNNN | 750 A | 450 kW | 400 kW | 315 kW | Very large Normal-Duty load |
| 20G1AJC770AN0NNNNN | 770 A | 450 kW | 400 kW | 355 kW | Highest capacity in this comparison |
The 20G1AJC770AN0NNNNN is particularly attractive when Heavy-Duty capacity matters.
Compared with the 750 A version, the 770 A model increases Heavy-Duty capacity from 315 kW to 355 kW.
This can be an important difference for applications with higher torque or overload requirements.
The following models are useful representative Allen-Bradley drive models for comparison across different power levels and applications.
| Model | Product Series | Voltage Class | Output / Power Class | Frame | Enclosure / Construction | Typical Application |
|---|---|---|---|---|---|---|
| 25B-D030N114 | PowerFlex 525 | 480 VAC class | 30 A class | Compact | Enclosed compact drive | Pumps, fans, conveyors, machinery |
| 25C-D030N114 | PowerFlex 527 | 480 VAC class | 30 A class | Compact | Machine-level drive | Networked machine automation |
| 20G1AGE053JA0NNNNN | PowerFlex 755 | 600 VAC, 3 PH | 53 A / 50 HP ND | Frame 6 | Type 12 / IP54 | Industrial pumps and machinery |
| 20G1AGC260JN0NNNNN | PowerFlex 755 | 400 VAC, 3 PH | 260 A / 132 kW ND | Frame 7 | Type 12 / IP54 | Large pumps, fans, conveyors |
| 20G1AND302JA0NNNNN | PowerFlex 755 | 480 VAC, 3 PH | 302 A / 250 HP ND | Frame 7 | Open type | Large industrial motor control |
These models represent different levels of motor-control capacity.
The 25B-D030N114 and 25C-D030N114 are much smaller and are more appropriate for machine-level applications.
The 20G1AGC260JN0NNNNN and 20G1AND302JA0NNNNN move into significantly larger industrial motor applications.
The 20G1AGE053JA0NNNNN provides an example of a higher-voltage PowerFlex 755 configuration.
| Parameter | 20G1AJC750AN0NNNNN | 20G1AJC770AN0NNNNN |
|---|---|---|
| Input | 400 VAC, 3 PH | 400 VAC, 3 PH |
| Current | 750 A | 770 A |
| Light Duty | 450 kW | 450 kW |
| Normal Duty | 400 kW | 400 kW |
| Heavy Duty | 315 kW | 355 kW |
| Frame | 8 | 8 |
| Enclosure | Type 12 / IP54 | Type 12 / IP54 |
| MCC Depth | 800 mm | 800 mm |
| Cooling | Forced Air | Forced Air |
| Dynamic Braking | None | None |
| Input | AC with Precharge | AC with Precharge |
| HIM | Blank / No HIM | Blank / No HIM |
| Main Difference | Lower HD capacity | Higher HD capacity |
The 770 A version is a logical step above the 750 A version.
The most significant practical difference is the Heavy-Duty rating.
The 750 A version provides 315 kW Heavy Duty, while the 770 A version provides 355 kW Heavy Duty.
Therefore, if the application has a demanding duty cycle, the 770 A version may provide a more suitable current envelope.
| Parameter | 20G1AJC650AN0NNNNN | 20G1AJC770AN0NNNNN |
|---|---|---|
| Input Voltage | 400 VAC | 400 VAC |
| Output Current | 650 A | 770 A |
| Light Duty | 400 kW | 450 kW |
| Normal Duty | 355 kW | 400 kW |
| Heavy Duty | 315 kW | 355 kW |
| Frame | 8 | 8 |
| Enclosure | Type 12 / IP54 | Type 12 / IP54 |
| MCC Depth | 800 mm | 800 mm |
| Cooling | Forced Air | Forced Air |
| Dynamic Braking | None | None |
| HIM | Blank / No HIM | Blank / No HIM |
The 770 A model provides a significant increase in current capacity over the 650 A model.
It also increases the power rating across all three duty categories.
This makes the 770 A version a stronger choice for motors approaching the upper end of the 650 A drive’s practical operating range.
The original 20G1AJC770AN0NNNNN has been discontinued.
The listed direct replacement is:
20G1AJC770JN0NNNNN.
The replacement model should be considered when purchasing new equipment or replacing an existing drive.
However, a replacement should always be evaluated against the complete installation rather than based only on catalog-number similarity.
The following should be checked:
The AN0-to-JN0 change is especially relevant because the catalog configuration changes the filter/common-mode jumper arrangement.
The incoming electrical system must be suitable for the 400 VAC three-phase drive configuration.
The upstream protection system should be designed according to the electrical requirements of the installation.
The incoming supply, disconnecting means, protective devices, grounding system, and cable sizing should be engineered as a complete system.
The motor cable must be correctly selected for:
Proper grounding is particularly important for large variable-frequency-drive installations.
The drive enclosure, motor, motor cable shield, cabinet, and associated control equipment should be incorporated into a properly engineered grounding system.
The drive uses forced-air cooling.
Therefore, the electrical room or enclosure must provide adequate airflow.
Hot exhaust air should not simply recirculate into the drive’s cooling inlet.
For installations containing several large drives, the total heat load of the room should be calculated.
High-power motor cables should be routed appropriately and separated from sensitive control and communication wiring where required.
Good cable management is important for both EMC performance and maintenance.
A drive of this size should be included in a structured preventive-maintenance program.
Typical inspection activities include:
Because this is a high-power floor-standing drive, maintenance should be performed by appropriately qualified personnel under the applicable electrical safety procedures.
| Selection Item | Requirement for Evaluation |
|---|---|
| Motor Voltage | Confirm compatibility with 400 VAC-class system |
| Motor Current | Compare with applicable drive-duty current |
| Motor Power | Compare with LD / ND / HD rating |
| Duty Cycle | Determine Light, Normal, or Heavy Duty |
| Acceleration | Evaluate required acceleration torque |
| Load Inertia | Calculate motor/load inertia |
| Deceleration | Evaluate regenerative energy |
| Braking | Determine whether external braking is necessary |
| Input Supply | Confirm three-phase supply |
| Enclosure | Confirm Type 12 / IP54 requirement |
| Installation Depth | Allow for 800 mm MCC-style configuration |
| Cooling | Provide sufficient forced-air ventilation |
| Communications | Confirm EtherNet/IP requirements |
| HIM | AN0 configuration has no HIM |
| EMC | Review filter, grounding, shielding and cable routing |
| Weight | Confirm final equipment/shipping weight |
| Dimensions | Confirm final mechanical drawing |
| Maintenance | Provide adequate service clearance |
| Replacement | Check current replacement configuration |
The most important selection criterion is the actual motor current under the intended operating duty.
The motor’s nominal kW value should be considered together with current, duty cycle, overload requirements, acceleration requirements, and mechanical load characteristics.
| Application | Typical Equipment | Reason for Using a High-Power VFD |
|---|---|---|
| Water Treatment | Large pumps | Flow and pressure control |
| Wastewater | Pumps and blowers | Process regulation |
| Mining | Conveyors, fans, pumps | High motor power and controlled acceleration |
| Cement | Fans, conveyors, process machinery | Variable-speed process control |
| Steel | Fans, pumps, process equipment | High-power motor regulation |
| Manufacturing | Large machinery | Speed and torque control |
| HVAC | Large fans and pumps | Airflow and water-flow control |
| Material Handling | Conveyors | Controlled acceleration and speed |
| Process Industry | Pumps, mixers, blowers | Process optimization |
| Industrial Utilities | Pumps and fans | Energy and process control |
The drive is particularly well suited to applications where the motor is too large for compact machine-level drives and where centralized industrial automation is required.
The principal strengths of the 20G1AJC770AN0NNNNN can be summarized as follows:
| Category | Final Specification |
|---|---|
| Product | PowerFlex 755 AC Drive |
| Model | 20G1AJC770AN0NNNNN |
| Brand | Allen-Bradley |
| Series | PowerFlex 755 |
| Product Family | PowerFlex 750-Series |
| Product Type | High-Power Air-Cooled AC Drive |
| Lifecycle | Discontinued |
| Direct Replacement | 20G1AJC770JN0NNNNN |
| Input Voltage | 380–400 VAC class |
| Nominal Voltage | 400 VAC |
| Phase | 3 Phase |
| Rated Output Current | 770 A |
| Light Duty | 450 kW |
| Normal Duty | 400 kW |
| Heavy Duty | 355 kW |
| Frame | Frame 8 |
| Cooling | Forced Air |
| Enclosure | Type 12 |
| Protection | IP54 |
| MCC Depth | 800 mm |
| Input | AC Input with Precharge |
| DC Terminals | None |
| EMC Filter | Yes |
| CM Jumper | Removed |
| Dynamic Braking | None |
| Communication | Embedded EtherNet/IP |
| HIM | Blank / No HIM |
| Approx. Width | ~600 mm class* |
| Approx. Height | ~2,000–2,200 mm* |
| Approx. Depth | ~800 mm |
| Approx. Weight | ~500–700 kg* |
| Installation | Floor-Standing MCC Style |
| Main Applications | Pumps, fans, blowers, conveyors, mining, water, wastewater, cement, process machinery and industrial utilities |
*Approximate mechanical planning values only; final dimensions and weight should be verified against the exact configured mechanical documentation.
The Allen-Bradley 20G1AJC770AN0NNNNN is a large-capacity PowerFlex 755 AC drive intended for demanding industrial motor-control applications.
Its 770 A output rating, 450 kW Light-Duty rating, 400 kW Normal-Duty rating, and 355 kW Heavy-Duty rating make it one of the stronger 400 VAC Frame 8 configurations in this part of the PowerFlex 755 range.
The combination of Frame 8 construction, 800 mm deep MCC-style packaging, Type 12 / IP54 protection, forced-air cooling, EMC filtering, AC input with precharge, and embedded EtherNet/IP makes it suitable for large centralized industrial drive systems.
From an application perspective, the model is particularly appropriate for large pumps, high-capacity fans, blowers, conveyors, mining machinery, water and wastewater equipment, cement plants, process machinery, industrial HVAC, and other large rotating equipment.
Its biggest technical advantage over the nearby 750 A configuration is the 355 kW Heavy-Duty rating, which provides additional capacity for demanding motor applications.
For new projects, the most important point is that 20G1AJC770AN0NNNNN is a discontinued catalog configuration and 20G1AJC770JN0NNNNN is its listed direct replacement. Replacement selection should include a review of the filtering/common-mode configuration, HIM requirements, control wiring, motor data, braking requirements, dimensions, weight, and installation conditions rather than relying solely on the catalog number.
For final mechanical installation, the exact configured dimensions and shipping weight should be confirmed before procurement or site preparation, especially because this is a large Frame 8, floor-standing drive that may require specialized handling and lifting equipment.