Our advantage
Global Logistics
We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.
Brand new and original
Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.
24-hour service
We provide 7*24 hours service to our customers. We will be there whenever you need us.
Price advantage
All our products are priced very favorably because we have our own warehouse and supply.
| Company Information | |||
| [email protected] | |||
| Mobile | +8615980777398 | ||
| +8615980777398 | |||
| 15980777398 |

The 20G11LE595AN2NNNNN is a high-power PowerFlex 755 AC drive intended for large industrial motor-control applications. It is a three-phase, 600 VAC-class, 595 A air-cooled packaged drive in Frame 9, with an 800 mm deep MCC-style enclosure.
The model is designed for applications where a large AC motor requires controlled acceleration, deceleration, variable-speed operation, process control and integration into an industrial automation system.
For clarity, the information below focuses on the product itself and does not include website links, source lists or external references.
| Item | Specification |
|---|---|
| Brand | Allen-Bradley |
| Product Family | PowerFlex |
| Product Series | PowerFlex 755 |
| Product Type | Air-Cooled Packaged AC Drive |
| Model | 20G11LE595AN2NNNNN |
| Voltage Class | 600 VAC |
| Input | Three-Phase AC |
| Output Current | 595 A |
| Frame Size | Frame 9 |
| Cooling | Air Cooled |
| Enclosure | IP20 / Type 1 |
| Cabinet Style | MCC Style |
| Cabinet Depth | 800 mm |
| Communication | Embedded EtherNet/IP |
| Dynamic Braking | None in this configuration |
| Filtering | EMC Filter Configuration |
| Input Type | AC Input with Precharge |
| Installation | Floor-standing industrial installation |
The 20G11LE595AN2NNNNN is a large-capacity variable-frequency AC drive designed to control the speed and torque of industrial AC motors.
Its 595 A output capability places it in the high-power range of the PowerFlex 755 family.
Unlike a conventional motor starter, which generally starts a motor at essentially full line frequency, a variable-frequency drive can control the electrical frequency and voltage delivered to the motor.
This allows the motor to accelerate gradually, operate at different speeds and decelerate in a controlled manner.
For large industrial machinery, this type of control can provide significant operational advantages.
A pump, for example, may not need to operate at full speed continuously. A large conveyor may require a slow starting speed before reaching normal production speed. A fan may need to change speed according to ventilation requirements.
The 20G11LE595AN2NNNNN is intended for precisely these types of applications.
The product belongs to the PowerFlex 755 series.
The PowerFlex 755 platform is designed for demanding industrial motor-control applications and is available in a broad range of power and voltage configurations.
The 20G11LE595AN2NNNNN represents a particularly high-power configuration.
Its combination of:
makes it suitable for large production machinery and process equipment.
| Parameter | 20G11LE595AN2NNNNN |
|---|---|
| Product Type | Air-Cooled AC Variable-Frequency Drive |
| Series | PowerFlex 755 |
| Voltage Rating | 600 VAC class |
| Input Phase | Three Phase |
| Output Current | 595 A |
| Light-Duty Rating | 700 HP class |
| Normal-Duty Rating | 600 HP class |
| Heavy-Duty Rating | 500 HP class |
| Frame | Frame 9 |
| Cooling | Air Cooled |
| Enclosure | IP20 / Type 1 |
| Cabinet Style | MCC Style |
| Cabinet Depth | 800 mm |
| Input Type | AC Input with Precharge |
| Filtering | EMC Filter |
| Dynamic Braking | None |
| Communication | Embedded EtherNet/IP |
| Overall Width | Approx. 900 mm class |
| Overall Height | Approx. 1700 mm class |
| Overall Depth | Approx. 800 mm class |
| Weight | Configuration dependent kg |
| Installation | Floor Standing |
The most important electrical characteristic of this model is its 595 A output current rating.
This makes it suitable for large AC motors and high-power industrial machinery.
The drive is designed for a 600 VAC, three-phase electrical system.
The motor and electrical supply should be checked carefully before installation.
| Electrical Parameter | Specification |
|---|---|
| Input Voltage | 600 VAC class |
| Input Phase | 3 Phase |
| Output Current | 595 A |
| Light-Duty Power | 700 HP |
| Normal-Duty Power | 600 HP |
| Heavy-Duty Power | 500 HP |
| Input Type | AC with Precharge |
| EMC Filtering | Included configuration |
| Dynamic Braking | None |
The 595 A configuration has different motor horsepower ratings depending on the duty requirement.
| Duty Type | Approximate Rating |
|---|---|
| Light Duty | 700 HP |
| Normal Duty | 600 HP |
| Heavy Duty | 500 HP |
This distinction is important when selecting the drive.
A motor operating a centrifugal fan may have a very different electrical load profile from a conveyor carrying heavy material.
The drive should therefore be selected based on the actual load characteristics rather than simply choosing a model according to the motor’s horsepower.
The light-duty rating is approximately 700 HP.
Light-duty applications generally have comparatively predictable loading and lower overload requirements.
Typical applications include:
The actual motor current should still be checked before selection.
The normal-duty rating is approximately 600 HP.
This rating is suitable for many conventional industrial motor applications.
Typical examples include:
The motor’s continuous current and operating cycle should be compared with the drive rating.
The heavy-duty rating is approximately 500 HP.
Heavy-duty applications can involve increased starting torque, frequent acceleration, high inertia or repeated overload conditions.
Potential applications include:
The heavy-duty rating is lower in horsepower because the drive must tolerate more demanding electrical and thermal operating conditions.
The Frame 9 designation indicates that this is a physically large, high-power drive.
Frame size is important for both electrical and mechanical planning.
A Frame 9 drive requires substantially more space than a compact variable-frequency drive.
Before installation, engineers should consider:
The model is associated with an 800 mm deep MCC-style cabinet.
A practical dimensional reference is approximately:
| Dimension | Approximate Value |
|---|---|
| Width | 900 mm class |
| Height | 1700 mm class |
| Depth | 800 mm class |
| Frame | Frame 9 |
| Cabinet Style | MCC Style |
| Installation | Floor Standing |
The exact overall dimensions can depend on the final packaged configuration and installation arrangement.
For engineering drawings, panel fabrication and installation work, the dimensions of the actual supplied unit should always take precedence over a general catalog reference.
The complete equipment weight should be regarded as configuration dependent.
Large packaged drives can contain different cabinet and power-component arrangements, so the total shipping and installed weight can vary.
| Weight Item | Specification |
|---|---|
| Drive Assembly | Configuration dependent kg |
| Cabinet | Configuration dependent kg |
| Complete Unit | Configuration dependent kg |
| Shipping Assembly | Configuration dependent kg |
| Installed Weight | Configuration dependent kg |
For lifting and transportation, the actual equipment shipping weight should be confirmed before moving the drive.
This is particularly important for a Frame 9 cabinet.
The drive uses an air-cooled design.
At a 595 A output rating, the amount of heat generated by the power electronics is significant.
The installation therefore requires adequate ventilation and heat removal.
Important environmental considerations include:
The cooling path should be kept clean and unobstructed.
The configuration uses an IP20 / Type 1 style enclosure arrangement.
This means the equipment is intended for installation in a suitable protected industrial environment.
It should not be treated as a waterproof or outdoor enclosure.
The electrical room or cabinet should protect the equipment from:
The 20G11LE595AN2NNNNN incorporates an EMC filter configuration.
This is useful in installations where electromagnetic compatibility is an important consideration.
Industrial facilities may contain many electrical devices operating simultaneously, including:
Good EMC design can help reduce unwanted electrical interference.
Proper cable routing, grounding and installation practices remain important even when filtering is provided.
The model uses an AC input with precharge arrangement.
Precharge is important in large DC-bus drive systems because it helps control the initial charging current when the drive is energized.
For a large-capacity drive, controlling the initial DC-bus charging process is an important part of the power architecture.
This is particularly relevant to high-power Frame 9 equipment.
The drive provides embedded EtherNet/IP communication.
This allows it to be integrated into a larger industrial control network.
Typical information exchanged can include:
| Information | Possible Function |
|---|---|
| Start Command | Start motor |
| Stop Command | Stop motor |
| Speed Reference | Set motor speed |
| Direction | Forward / reverse control |
| Actual Speed | Monitor motor operation |
| Output Current | Monitor load |
| Drive Status | Monitor operating condition |
| Warning | Maintenance indication |
| Fault | Troubleshooting |
| Ready Status | Control-system interlock |
This makes the drive suitable for centralized automation systems.
The drive is well suited to large pump systems.
Examples include:
Variable-speed operation can help match pump output to actual process demand.
Large industrial fans can require hundreds of horsepower.
The drive can regulate fan speed according to airflow requirements.
Applications include:
Blowers can require substantial motor power, particularly in continuous industrial processes.
Potential applications include:
Large conveyors can require considerable starting torque.
The drive can provide controlled acceleration and adjustable running speed.
Potential applications include:
Large mining operations use high-power motors for material movement, ventilation and water handling.
Potential applications include:
The installation environment should be evaluated carefully because dust and temperature can affect drive performance.
Large cement and aggregate facilities often have high-power motors throughout the production process.
Applications can include:
| Advantage | Description |
|---|---|
| 595 A Output | Provides substantial capacity for large industrial motors |
| 600 VAC Class | Suitable for large industrial motor systems |
| PowerFlex 755 Platform | Designed for advanced industrial drive applications |
| Frame 9 | Provides high-power capability |
| Air Cooling | Practical cooling arrangement for large industrial installations |
| EMC Filtering | Helps address electromagnetic compatibility requirements |
| EtherNet/IP | Supports industrial automation integration |
| 800 mm Cabinet Depth | Provides an industrial MCC-style arrangement |
| Variable-Speed Control | Allows motor speed to follow process requirements |
| Controlled Acceleration | Helps reduce mechanical shock |
| Multiple Duty Ratings | Allows selection based on load characteristics |
One of the major reasons for using a variable-frequency drive is to avoid operating a motor unnecessarily at full speed.
This is particularly valuable for centrifugal pumps and fans.
For suitable variable-torque applications, reducing motor speed can significantly reduce the power required by the machine.
Potential benefits include:
Actual savings depend on the application and operating profile.
Large motors can produce substantial mechanical stress when started directly.
The drive can provide controlled acceleration.
This can reduce sudden mechanical loading on:
For large machines, smoother acceleration can improve overall operating behavior.
The drive allows motor speed to become a process-control variable.
Instead of simply switching a motor between OFF and ON, the motor can operate at an appropriate speed.
For example:
Pump application:
Low demand → low motor speed.
Medium demand → medium motor speed.
High demand → higher motor speed.
This gives the process system more flexibility.
The drive can provide useful operating information to the control system.
Maintenance personnel can monitor:
A good maintenance program should also include physical inspection.
| Maintenance Area | Recommended Attention |
|---|---|
| Cooling Fans | Inspect periodically |
| Air Passages | Keep clean |
| Cabinet | Check for contamination |
| Power Connections | Inspect according to maintenance procedures |
| Motor Cables | Inspect for overheating/damage |
| Grounding | Verify periodically |
| Network Cable | Inspect communication connections |
| Fault History | Investigate recurring faults |
| Temperature | Monitor operating environment |
| Dust | Control accumulation |
The following are useful related PowerFlex 755 configurations for comparison.
| Model | Series | Voltage | Output Current | LD Rating | ND Rating | HD Rating | Dimensions | Weight kg |
|---|---|---|---|---|---|---|---|---|
| 20G11LE595AN2NNNNN | PowerFlex 755 | 600 VAC | 595 A | 700 HP | 600 HP | 500 HP | 900 × 1700 × 800 mm class | Configuration dependent |
| 20G11LE630AN2NNNNN | PowerFlex 755 | 600 VAC | 630 A | 800 HP class | 700 HP class | 600 HP class | 900 × 1700 × 800 mm class | Configuration dependent |
| 20G11LE760AN2NNNNN | PowerFlex 755 | 600 VAC | 760 A | 900 HP class | 800 HP class | 700 HP class | Frame 9 / cabinet dependent | Configuration dependent |
| 20G11LE825AN2NNNNN | PowerFlex 755 | 600 VAC | 825 A | 950 HP class | 900 HP class | 750 HP class | Frame 9 / cabinet dependent | Configuration dependent |
| 20G11LE900AN2NNNNN | PowerFlex 755 | 600 VAC | 900 A | 1000 HP class | 950 HP class | 800 HP class | Frame 9 / cabinet dependent | Configuration dependent |
These models are useful when comparing drive capacity around the 595 A range.
The higher-current versions may be considered when the motor’s actual full-load current, overload requirements or duty cycle exceed the 595 A configuration.
| Model | Series | Voltage | Current | Duty | Cooling | Cabinet Depth | Dimensions | Weight kg |
|---|---|---|---|---|---|---|---|---|
| 20G11LE595AN0NNNNN | PowerFlex 755 | 600 VAC | 595 A | LD/ND/HD | Air Cooled | 800 mm | Configuration dependent | Configuration dependent |
| 20G11LE595JN0NNNNN | PowerFlex 755 | 600 VAC | 595 A | LD/ND/HD | Air Cooled | 800 mm | Configuration dependent | Configuration dependent |
| 20G11LE595JN2NNNNN | PowerFlex 755 | 600 VAC | 595 A | LD/ND/HD | Air Cooled | 800 mm | Configuration dependent | Configuration dependent |
| 20G11LE630AN2NNNNN | PowerFlex 755 | 600 VAC | 630 A | LD/ND/HD | Air Cooled | 800 mm class | Configuration dependent | Configuration dependent |
| 20G11LE760AN2NNNNN | PowerFlex 755 | 600 VAC | 760 A | LD/ND/HD | Air Cooled | 800 mm class | Configuration dependent | Configuration dependent |
The configuration characters should be checked carefully when selecting a replacement.
Two drives can have the same current rating while having different filtering, cabinet, input-protection or other configuration characteristics.
| Model | Product Family | Voltage Class | Current / Capacity | Typical Application | Dimensions | Weight kg |
|---|---|---|---|---|---|---|
| 25B-D2P3N114 | PowerFlex 525 | 480 VAC class | 2.3 A class | Small machinery | Compact | Configuration dependent |
| 25B-D6P0N114 | PowerFlex 525 | 480 VAC class | 6.0 A class | Small pumps/fans | Compact | Configuration dependent |
| 20F11ND077JA0NNNNN | PowerFlex 753 | 480 VAC class | 77 A class | Medium industrial machinery | Frame dependent | Configuration dependent |
| 20G11LE595AN2NNNNN | PowerFlex 755 | 600 VAC | 595 A | Large industrial machinery | 900 × 1700 × 800 mm class | Configuration dependent |
| 20G11LE900AN2NNNNN | PowerFlex 755 | 600 VAC | 900 A | Very large industrial machinery | Frame 9 / cabinet dependent | Configuration dependent |
These five models cover a wide range of industrial drive applications.
The compact models are appropriate for much smaller motors, while the PowerFlex 755 configurations are intended for large and very large motor systems.
| Model | Current | LD | ND | HD | Suitable Application |
|---|---|---|---|---|---|
| 20G11LE595AN2NNNNN | 595 A | 700 HP | 600 HP | 500 HP | Large pumps, fans, conveyors |
| 20G11LE630AN2NNNNN | 630 A | 800 HP class | 700 HP class | 600 HP class | Larger industrial machinery |
| 20G11LE760AN2NNNNN | 760 A | 900 HP class | 800 HP class | 700 HP class | Heavy industrial machinery |
| 20G11LE825AN2NNNNN | 825 A | 950 HP class | 900 HP class | 750 HP class | Very large industrial machinery |
| 20G11LE900AN2NNNNN | 900 A | 1000 HP class | 950 HP class | 800 HP class | Very high-power motor systems |
| Application | Suitability |
|---|---|
| Small Pump | Not recommended — substantially oversized |
| Small Fan | Not recommended — substantially oversized |
| Medium Pump | Generally oversized |
| Medium Fan | Generally oversized |
| Large Pump | Excellent |
| Large Fan | Excellent |
| Large Blower | Excellent |
| Large Conveyor | Excellent |
| Mining Conveyor | Very Suitable |
| Cement Conveyor | Very Suitable |
| Aggregate Handling | Very Suitable |
| Large Ventilation System | Excellent |
| Large Process Machinery | Very Suitable |
| High-Inertia Machinery | Suitable after detailed evaluation |
| Heavy Starting Load | Requires duty-cycle verification |
The installation should be planned around the size and power of the equipment.
Important considerations include:
Confirm that the incoming supply is appropriate for a 600 VAC-class, three-phase drive.
Confirm:
Allow sufficient space for the approximately 800 mm deep cabinet arrangement and required service clearances.
Provide sufficient airflow for the air-cooled drive.
Large current levels require appropriate power cables, termination methods and routing.
Proper grounding is essential for both electrical safety and EMC performance.
The actual equipment weight in kg should be confirmed before transportation and installation.
When replacing another drive with the 20G11LE595AN2NNNNN, do not compare only horsepower.
The following parameters should be checked:
| Selection Item | Importance |
|---|---|
| Input Voltage | Critical |
| Output Current | Critical |
| Motor Full-Load Current | Critical |
| Duty Cycle | Critical |
| Motor Horsepower | High |
| Starting Torque | High |
| Acceleration Time | High |
| Deceleration Requirements | High |
| EMC Requirements | High |
| Cabinet Dimensions | High |
| Cooling | High |
| Communication | High |
| Dynamic Braking | Application dependent |
| Weight | High for installation |
The 595 A configuration provides a substantial amount of motor-control capacity while remaining below the even larger 630 A, 760 A, 825 A and 900 A configurations.
For a motor whose actual current requirement is appropriate for the 595 A rating, this can provide a practical balance between capacity and physical equipment size.
The drive can be particularly attractive when the application requires:
| Advantage | Explanation |
|---|---|
| 595 A Current Rating | Provides high motor-control capacity |
| 600 VAC Class | Suitable for large industrial electrical systems |
| PowerFlex 755 Series | Designed for advanced industrial applications |
| Frame 9 | Supports high-power machinery |
| Air Cooling | Practical high-power cooling method |
| EMC Filter | Supports electromagnetic compatibility |
| EtherNet/IP | Allows network-based control and monitoring |
| 800 mm Cabinet | Suitable for large MCC-style installations |
| Variable Speed | Provides process flexibility |
| Controlled Starting | Reduces mechanical shock |
| Large Motor Capability | Suitable for pumps, fans, conveyors and process machinery |
| Category | Parameter | 20G11LE595AN2NNNNN |
|---|---|---|
| Product | Model | 20G11LE595AN2NNNNN |
| Brand | Brand | Allen-Bradley |
| Series | Series | PowerFlex 755 |
| Product Type | Type | Air-Cooled Packaged AC Drive |
| Electrical | Input Voltage | 600 VAC class |
| Electrical | Phase | 3 Phase |
| Electrical | Output Current | 595 A |
| Power | Light Duty | 700 HP |
| Power | Normal Duty | 600 HP |
| Power | Heavy Duty | 500 HP |
| Frame | Frame Size | Frame 9 |
| Cooling | Cooling | Air Cooled |
| Enclosure | Protection | IP20 / Type 1 |
| Cabinet | Style | MCC Style |
| Cabinet | Depth | 800 mm |
| Dimensions | Width | Approx. 900 mm class |
| Dimensions | Height | Approx. 1700 mm class |
| Dimensions | Depth | Approx. 800 mm class |
| Input | Input Type | AC Input with Precharge |
| Filtering | EMC | EMC Filter |
| Braking | Dynamic Braking | None |
| Communication | Network | Embedded EtherNet/IP |
| Weight | Complete Unit | Configuration dependent kg |
| Installation | Mounting | Floor Standing |
The 20G11LE595AN2NNNNN is a high-capacity industrial AC drive designed for demanding motor-control applications.
Its core specifications — 600 VAC class, 595 A, Frame 9, air-cooled construction and 800 mm deep MCC-style packaging — make it particularly suitable for large industrial machines.
The drive is well matched to applications such as large pumps, fans, blowers, conveyors, mining equipment, cement machinery, aggregate handling systems and large process equipment.
Its EMC filter configuration is useful where electromagnetic compatibility is an important consideration, while the embedded EtherNet/IP capability allows the drive to participate in an industrial automation network.
The different light-duty, normal-duty and heavy-duty ratings also make it possible to evaluate the same drive capacity against different mechanical load conditions.
For engineering purposes, the most important parameters are the 595 A output current, 600 VAC voltage class, motor full-load current, duty cycle and actual application torque requirement.
The mechanical side is equally important. The equipment is a large Frame 9 package with an 800 mm cabinet depth, and the complete installed weight should be confirmed in kg from the actual equipment configuration before transportation, lifting or floor-loading calculations.
In short, the 20G11LE595AN2NNNNN is best suited to large industrial installations where a high-power AC motor requires controlled speed, controlled acceleration, process flexibility and integration into an industrial automation system.