The Siemens 6AG1067-1AA25-0AA0 Compact Training Case is a portable industrial drive training system designed for technical education, product demonstrations, engineering tests, and practical automation training. It is based on the SINAMICS G120C frequency converter and provides a compact setup for demonstrating variable-speed motor control and PROFIBUS communication.
Unlike an empty storage case, this product is a complete training package containing several drive-system components. Its documented configuration includes a 0.55 kW SINAMICS G120C frequency converter, IOP-2 and BOP-2 operator panels, and a SIMOTICS asynchronous induction motor. The system is designed to help users understand the relationship between a frequency converter, motor operation, operator controls, and industrial communication.
The training case operates from a 230 V single-phase AC supply. Its integrated components allow users to explore basic drive configuration, motor speed adjustment, operating commands, and communication-related functions in a controlled training environment.
The 6AG1067-1AA25-0AA0 is particularly relevant to technical schools, vocational training centers, automation laboratories, engineering departments, and industrial service organizations. Its compact case format makes it easier to transport, store, and use in different training locations.
The PROFIBUS version is an important distinction when comparing this model with other Siemens training cases. The corresponding PROFINET / EtherNet/IP training case uses a different order number. Buyers should therefore verify the full article number and communication configuration before ordering.
| Parameter | Specification |
|---|---|
| Brand | Siemens |
| Manufacturer | Siemens AG |
| Model | 6AG1067-1AA25-0AA0 |
| Product Type | Compact Drive Training Case |
| Product Series | SINAMICS G120C |
| Training System | SINAMICS G120C PROFIBUS |
| Main Drive | SINAMICS G120C Frequency Converter |
| Drive Power Rating | 0.55 kW |
| Communication Variant | PROFIBUS |
| Supply Voltage | 230 V AC |
| Supply Phase | Single-phase |
| Operator Panels | IOP-2 and BOP-2 |
| Motor | SIMOTICS Asynchronous Induction Motor |
| Case Type | Stackable Tanos Systainer Size 4 |
| Dimensions | 315 × 400 × 300 mm |
| Weight Provided | 10 kg |
| Manufacturer Reference Weight | Approximately 9 kg |
| Typical Applications | Training, demonstration, testing, and drive-system education |
Note: Siemens documentation gives an approximate product weight of 9 kg. The 10 kg supplied value may represent a rounded or packaged shipping weight. Confirm the actual weighing basis when preparing logistics information.
The 6AG1067-1AA25-0AA0 provides a practical environment for learning how a frequency converter controls an AC motor. It combines a drive, operator interfaces, a motor, and a portable enclosure in one training arrangement.
The SINAMICS G120C frequency converter adjusts the electrical frequency and voltage supplied to the connected motor. This enables the motor to operate at different speeds according to the configured reference and operating conditions.
During training, users can observe how changing a speed command affects motor operation. This makes it possible to demonstrate the basic principles of variable-speed control without requiring a full industrial production machine.
The 0.55 kW drive provides a compact platform for studying motor-control functions and basic drive commissioning.
The training case includes IOP-2 and BOP-2 operator panels. These interfaces support interaction with the SINAMICS drive and provide different approaches to parameter access and operation.
The BOP-2 is intended for basic parameterization and drive operation. The IOP-2 provides a more guided operator interface, helping users navigate drive functions and configuration tasks.
Using these panels, trainees can become familiar with parameter navigation, drive status information, operating commands, and basic commissioning procedures.
The included SIMOTICS asynchronous induction motor allows the drive to demonstrate actual motor behavior. Rather than studying drive parameters only through documentation or software, users can observe the relationship between the converter output and motor response.
Training exercises can include starting and stopping the motor, changing speed references, observing acceleration and deceleration, and reviewing operating conditions.
The motor provides a practical load for demonstrating the basic operation of a variable-frequency drive.
This training case is the PROFIBUS variant of the SINAMICS G120C training system. PROFIBUS is an established industrial fieldbus technology used for communication between automation controllers and field devices.
The training system can help users understand how drive communication fits into an industrial automation architecture. Exercises may include examining communication settings, understanding the role of a fieldbus connection, and learning how a drive exchanges control and status information with a compatible controller.
The exact communication exercises depend on the available controller, software, cabling, and training setup.
The equipment is supplied in a stackable Tanos Systainer Size 4 case. This enclosure provides a convenient way to transport and store the training system.
Its portable design is useful for organizations that conduct training sessions in different classrooms, laboratories, customer facilities, or technical departments.
The Siemens 6AG1067-1AA25-0AA0 is intended to support practical learning about industrial drive technology. It can be used to introduce the main elements of a variable-speed motor-control system.
Trainees can examine how a frequency converter receives electrical power, processes control commands, and supplies controlled power to a motor.
This helps explain the relationship between the electrical supply, drive electronics, control parameters, and motor output.
The included IOP-2 and BOP-2 panels provide opportunities to practice drive parameter access and configuration.
Typical training subjects include:
Specific exercises should follow the applicable SINAMICS G120C documentation and the training provider’s procedures.
The PROFIBUS configuration makes the training case useful for introducing fieldbus-based drive integration.
Students and engineers can study how a frequency converter communicates with a compatible automation controller and how control commands and status information are exchanged.
This knowledge is relevant to industrial maintenance, automation commissioning, and drive-system troubleshooting.
The training case allows users to work with real drive hardware and an actual motor. This creates opportunities to study operating behavior, review parameter settings, and understand common drive-related issues.
Practical exercises can help bridge the gap between theoretical knowledge and industrial maintenance work.
The training case can be used in courses covering electrical engineering, industrial automation, motor control, and variable-frequency drive technology.
Students can learn how to configure a drive, operate an AC motor, and understand the basic relationship between control parameters and motor behavior.
Engineering laboratories can use the training case for demonstrations, controlled tests, and introductory drive experiments.
Its integrated components reduce the need to assemble a complete training setup from separately sourced equipment.
The PROFIBUS version is suitable for introductory training on fieldbus-connected drive systems.
Training exercises can explain communication architecture, drive configuration, and the relationship between field devices and automation controllers.
Maintenance departments can use the system to introduce technicians to drive operation and basic troubleshooting procedures.
The training case can support instruction on parameter access, motor behavior, fault interpretation, and routine commissioning checks.
System integrators and technical sales teams can use the compact case to demonstrate SINAMICS G120C functions to customers.
The integrated motor and operator panels make it possible to show basic drive operation in a portable environment without installing a complete production machine.
Technical departments may use the training system for preliminary tests and demonstrations involving drive parameters, motor speed control, and PROFIBUS-related concepts.
It is intended as a compact training and demonstration platform rather than a substitute for a full industrial test bench.
Although the training case is supplied as an integrated package, proper setup and handling remain important.
The training system is specified for a 230 V single-phase AC supply.
Before powering the unit, confirm that the available electrical supply matches the rating and requirements shown in the equipment documentation. Do not connect it to an incompatible three-phase or different-voltage supply.
Place the case on a stable, level surface with sufficient space for operating the panels and observing the motor.
Keep the ventilation openings clear and avoid placing the equipment near excessive heat, moisture, conductive dust, or other environmental hazards.
Before operation, inspect the visible power and control connections. Confirm that the motor and drive are connected according to the manufacturer’s training instructions.
Do not modify the internal wiring unless the work is part of an approved training procedure performed by qualified personnel.
Use the provided operator interface to review the drive configuration and enter the required motor data.
Training personnel should explain the relationship between motor nameplate information, control parameters, speed references, and operating commands.
Incorrect parameter settings can affect motor operation and may cause faults. Follow the manufacturer’s commissioning instructions.
When conducting communication exercises, verify the PROFIBUS configuration and the compatibility of any external controller or communication equipment.
The required network components and software depend on the training exercise. They should not be assumed to be included unless confirmed in the supplied package.
Training activities involving electrical equipment and rotating machinery must be supervised and conducted by qualified personnel.
Keep hands, cables, and loose objects away from moving motor components. Isolate the power supply before carrying out wiring changes or maintenance.
The training case integrates several components that work together to demonstrate variable-speed motor control.
| Component | Function | Training Value |
|---|---|---|
| SINAMICS G120C frequency converter | Controls the electrical power supplied to the motor | Demonstrates variable-frequency motor control |
| IOP-2 operator panel | Provides a guided interface for drive operation and configuration | Supports parameter navigation and operator training |
| BOP-2 operator panel | Provides basic drive operation and parameter access | Introduces basic commissioning procedures |
| SIMOTICS induction motor | Converts electrical power into mechanical motion | Allows users to observe real motor behavior |
| PROFIBUS configuration | Provides the specified fieldbus communication variant | Introduces industrial drive communication |
| Tanos Systainer Size 4 case | Stores and transports the training equipment | Supports portable training and demonstration activities |
The external controller, additional PROFIBUS network equipment, programming software, and other accessories should be checked against the actual delivery scope.
The 6AG1067-1AA25-0AA0 belongs to Siemens’ SINAMICS training equipment range. Other training cases may be considered depending on the drive family, communication interface, and educational objectives.
| Model or Product Family | Description | Selection Considerations |
|---|---|---|
| 6AG1067-2AA00-0AA0 | SINAMICS G120C training case, PROFINET / EtherNet/IP version | Consider when the training environment uses PROFINET or EtherNet/IP |
| 6AG1067-1AA25-0AA0 | SINAMICS G120C training case, PROFIBUS version | Suitable for PROFIBUS-focused drive training |
| SINAMICS V20 training case | Compact training platform for basic drive and motor operation | Consider for introductory variable-speed drive education |
| SINAMICS G120P training case | Training platform based on the G120P drive family | Consider for relevant pump, fan, and HVAC drive topics |
| SINAMICS S200 training case | Servo-drive training platform | More appropriate for servo and motion-control education |
These products are not necessarily direct replacements. Their hardware, functions, power ratings, communication interfaces, and training objectives differ.
The package combines a frequency converter, operator panels, and an induction motor, providing a practical platform for drive demonstrations and learning.
The model provides a specific PROFIBUS configuration for organizations that need to introduce or demonstrate fieldbus-connected drive systems.
The included motor allows users to observe the effects of drive settings on actual motor operation.
The IOP-2 and BOP-2 panels support different approaches to parameter access and drive operation, making the system useful for a range of training exercises.
The stackable Systainer case supports convenient storage and transportation between training locations.
The compact arrangement can be used by technical schools, engineering departments, system integrators, and industrial service organizations.
The training system provides a practical environment for introducing parameterization, operating commands, motor configuration, and basic drive troubleshooting.
It is a SINAMICS G120C compact training case configured for PROFIBUS communication. It includes a 0.55 kW frequency converter, IOP-2 and BOP-2 operator panels, and a SIMOTICS induction motor.
No. It is a complete drive training package supplied in a portable case. The case contains the documented drive-system training components.
The included SINAMICS G120C frequency converter has a rated power of 0.55 kW.
The documented supply voltage is 230 V single-phase AC. Always verify the equipment label and instructions before connecting power.
This catalog number identifies the PROFIBUS version of the SINAMICS G120C training case. It should not be confused with the PROFINET / EtherNet/IP version.
The IOP-2 provides a guided interface for operating and configuring the SINAMICS drive. It helps users access parameters and review drive information during training.
The two panels provide different operator-interface approaches. Their inclusion allows trainees to become familiar with different methods of accessing drive functions and parameters.
The SIMOTICS asynchronous induction motor provides a real motor load for the frequency converter. It allows users to observe speed changes and basic drive-control behavior.
The documented dimensions are 315 × 400 × 300 mm. Siemens lists an approximate product weight of 9 kg, while a 10 kg figure may be used for packaged or shipping weight.
Technical schools, vocational training centers, engineering laboratories, industrial maintenance departments, and automation system integrators can use it for drive demonstrations, training, and basic testing.
Before purchasing the Siemens 6AG1067-1AA25-0AA0, verify the complete order number and confirm that the required PROFIBUS version is being supplied. This is especially important when comparing it with the related PROFINET / EtherNet/IP training case.
Check the delivery scope carefully. The documented package includes the SINAMICS G120C 0.55 kW frequency converter, IOP-2 and BOP-2 operator panels, and a SIMOTICS induction motor. Confirm the condition and presence of these components when purchasing used or surplus equipment.
For a new or refurbished unit, request photographs of the case, drive nameplate, operator panels, motor, and relevant connections. If the training system will be used for practical instruction, confirm that it can be powered up and that the main components operate correctly.
During storage, keep the case closed when the equipment is not in use and protect it from moisture, dust, and impact. Before each training session, inspect the external connections, cables, motor mounting, and case condition.
The training system should be operated according to Siemens documentation and appropriate electrical safety procedures. Parameter changes and wiring exercises should be performed under qualified supervision.
The Siemens 6AG1067-1AA25-0AA0 Compact Training Case is a portable SINAMICS G120C PROFIBUS training system designed for practical education, drive demonstrations, and technical testing. Its documented configuration includes a 0.55 kW frequency converter, IOP-2 and BOP-2 operator panels, and a SIMOTICS induction motor, operating from a 230 V single-phase AC supply.
With its integrated components and stackable carrying case, the system provides a convenient platform for learning variable-frequency motor control and PROFIBUS-related drive concepts. It is particularly relevant to vocational training centers, engineering laboratories, automation departments, and industrial maintenance organizations.