Product Overview The Schneider Electric NW10N1 MasterPact NW Circuit Breaker is a low-voltage air circuit breaker designed for high-capacity power distribution systems. It belongs to the MasterPact NW s……
Schneider NW10N1 Circuit Breaker
  • Schneider
  • NW10N1
  • Circuit Breaker
  • France
  • 352 x 537 x 297 mm
  • 65 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 3

Our advantage

Schneider NW10N1 Circuit Breaker

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Schneider NW10N1 Circuit Breaker

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Schneider NW10N1 Circuit Breaker

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Schneider NW10N1 Circuit Breaker

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Schneider Electric NW10N1 MasterPact NW Circuit Breaker is a low-voltage air circuit breaker designed for high-capacity power distribution systems. It belongs to the MasterPact NW series, a range developed for industrial facilities, commercial buildings, and large electrical installations requiring reliable circuit protection and switching.

The NW10N1 is based on a 1000 A frame rating and uses the N1 breaking-performance class. Its rated ultimate short-circuit breaking capacity is 42 kA at 440 V AC. This capability makes it suitable for electrical distribution applications where the available prospective fault current must be evaluated and coordinated with the protective devices installed throughout the system.

The identified Schneider Electric configuration is a four-pole, fixed-mounted circuit breaker frame supplied without a control unit. This distinction is important: the breaker frame provides the mechanical switching platform, but the appropriate control and protection equipment must be selected according to the electrical installation and the intended protection functions.

The MasterPact NW platform is commonly used in main distribution boards, switchboards, generator systems, and industrial power centers. Its role is to interrupt abnormal current conditions and provide controlled switching of electrical circuits.

With dimensions of 352 × 537 × 297 mm and a supplied weight of 65 kg, the NW10N1 is a substantial electrical distribution component. Installation requires a properly designed switchboard, suitable mounting arrangements, correct electrical connections, and compliance with the manufacturer’s installation instructions.

Technical Specifications

Parameter Specification
Brand Schneider Electric
Product Series MasterPact NW
Model NW10N1
Product Type Air Circuit Breaker (ACB)
Application Power Distribution Protection
Frame Rating 1000 A
Rated Operational Voltage Up to 690 V AC, depending on system configuration
N1 Breaking Performance 42 kA at 440 V AC
Rated Ultimate Breaking Capacity (Icu) 42 kA at 440 V AC
Rated Service Breaking Capacity (Ics) 42 kA at 440 V AC
Rated Short-Time Withstand Current (Icw) 42 kA for 1 second
Pole Configuration 4 Poles
Mounting Type Fixed
Control Unit Not included in the identified configuration
Sensor Rating Options 400 A, 630 A, 800 A, 1000 A
Rated Insulation Voltage (Ui) 1000 V AC
Rated Impulse Withstand Voltage (Uimp) 12 kV
Standards IEC 60947-1, IEC 60947-2
Dimensions 352 × 537 × 297 mm
Weight 65 kg

Note: The exact electrical configuration, control unit, sensor rating, accessories, and connection arrangement must be confirmed against the product nameplate and order documentation. The NW10N1 model designation alone does not identify every component supplied with a complete breaker assembly.

Function and Working Principle

The NW10N1 is designed to provide switching and protection functions in low-voltage power distribution systems. It is installed in an electrical distribution assembly and forms part of the protective arrangement between the power source and downstream electrical loads.

1. Overload Protection

An overload occurs when an electrical circuit carries more current than its intended operating level for an extended period.

In a properly configured MasterPact NW installation, the selected protection unit monitors current conditions and initiates a trip when the applicable overload protection threshold and time characteristic are exceeded.

This helps protect cables, busbars, transformers, and connected equipment from excessive thermal stress.

Because the identified NW10N1 configuration is supplied without a control unit, the appropriate protection unit must be specified separately where required.

2. Short-Circuit Protection

A short circuit can produce a very high fault current within a short period. If the fault is not interrupted, it can cause severe thermal and mechanical damage to electrical equipment.

The NW10N1 uses the N1 breaking-performance class, with a published 42 kA ultimate short-circuit breaking capacity at 440 V AC.

The actual protective performance depends on the system voltage, prospective fault current, protection configuration, and installation conditions. Engineers must verify that the circuit breaker’s breaking capacity is suitable for the available fault current at the installation point.

3. Switching and Isolation

The MasterPact NW platform provides switching functionality for power distribution circuits. Depending on the complete configuration, the breaker can be operated manually or through suitable electrical operating accessories.

A four-pole configuration switches three phase conductors and the neutral conductor. This can be relevant in distribution systems where neutral switching is part of the electrical design.

The breaker must be installed and operated according to the applicable electrical regulations and the manufacturer’s instructions.

4. Short-Time Current Withstand

The published short-time withstand rating is 42 kA for one second. This characteristic is relevant to protection coordination in installations where a downstream fault may be allowed to persist briefly to maintain selectivity with other protective devices.

The coordination study must consider the complete protection arrangement, including upstream and downstream breakers, conductor ratings, and the actual fault-current levels.

5. Protection Coordination

In a large electrical distribution system, several circuit breakers may be installed at different levels. Their protection settings should be coordinated so that the device closest to a fault operates whenever practical.

The MasterPact NW platform can form part of a coordinated protection strategy. Proper settings depend on the selected control unit, current sensors, electrical system characteristics, and the protection study.

Role in Industrial Power Distribution Systems

The NW10N1 is intended for high-capacity electrical distribution applications. It can be installed in main switchboards and distribution assemblies where large electrical loads require a dedicated switching and protection device.

Main Distribution Board Protection

In an industrial facility, the main distribution board receives electrical power from a transformer, generator, or utility connection and distributes it to downstream circuits.

A 1000 A frame circuit breaker can serve as a major switching and protection component where the calculated load and protection requirements are suitable.

The NW10N1’s four-pole arrangement may be used where the system design requires switching of the neutral conductor in addition to the three phases.

Transformer and Generator Systems

Industrial power systems often include transformers and generators supplying multiple distribution sections.

Circuit breakers are used to connect and disconnect these sources and protect the associated distribution circuits. Their ratings must be selected according to the source capacity, short-circuit characteristics, grounding arrangement, and operating requirements.

Busbar Protection

Busbars distribute electrical power between incoming sources and outgoing feeders. A fault on a busbar can affect a large section of the electrical installation.

The NW10N1 can be incorporated into an appropriate switchboard protection arrangement. Its rated current and short-circuit performance must match the design of the busbar system and the expected fault conditions.

Industrial Power Management

Manufacturing plants often operate motors, pumps, compressors, heating equipment, production machinery, and auxiliary electrical systems.

The circuit breaker provides a switching and protective function within the power distribution architecture. It works alongside other protection devices, monitoring equipment, and control systems to support safe electrical operation.

Industrial Applications

The Schneider Electric NW10N1 can be considered for power distribution systems requiring a 1000 A frame circuit breaker and a suitable N1 breaking-performance level.

1. Manufacturing Facilities

Large manufacturing facilities use electrical distribution systems to supply production lines, machine centers, material-handling equipment, and utility systems.

A suitable MasterPact NW installation can provide protection and switching at the main distribution or feeder level.

The actual breaker selection must be based on calculated demand, fault current, protection coordination, and the characteristics of the connected loads.

2. Industrial Power Distribution Panels

Main switchboards and power distribution panels require circuit breakers that can handle the expected operating current and interrupt fault currents safely.

The NW10N1 can be used in a compatible fixed-mounted switchboard arrangement, subject to the required control-unit and accessory configuration.

3. Data Centers

Data centers depend on electrical distribution systems to supply servers, cooling equipment, UPS systems, and supporting infrastructure.

Circuit breakers are used throughout these installations to protect incoming supplies and distribution feeders. The NW10N1 may be considered for an appropriately rated distribution section where its electrical specifications and protection characteristics meet the design requirements.

4. Utility and Infrastructure Facilities

Water treatment plants, transportation infrastructure, large commercial buildings, and utility facilities use high-capacity distribution systems.

MasterPact NW circuit breakers can form part of these systems, providing switching and protection for suitable electrical circuits.

5. Generator and Backup Power Installations

Backup generators are commonly connected to distribution boards through switching and protection equipment.

A correctly selected air circuit breaker can provide circuit protection and switching functions in the generator distribution arrangement. Coordination with transfer switches, generator protection, and upstream equipment must be evaluated during system design.

Installation and System Integration

The NW10N1 is a large power circuit breaker and should only be installed by qualified electrical personnel following the manufacturer’s instructions and applicable electrical codes.

1. Verify the Electrical Ratings

Before installation, confirm the system voltage, rated operating current, available short-circuit current, frequency, and grounding arrangement.

The 1000 A frame rating does not automatically mean that every installation should operate continuously at 1000 A. The selected sensor and protection configuration must be appropriate for the connected load and conductor ratings.

2. Confirm the Control Unit and Sensor Configuration

The identified product configuration is supplied without a control unit.

Before commissioning, determine which compatible control unit and sensor arrangement are required. Verify the selected sensor rating and protection functions against the electrical design.

Do not assume that a control unit or protection sensor is included simply because the product is described as a complete circuit breaker in a supplier listing.

3. Check Switchboard Dimensions

The supplied dimensions are 352 × 537 × 297 mm. These dimensions correspond to the fixed-mounted four-pole MasterPact NW10N1 configuration.

The switchboard design should allow adequate space for mounting, electrical connections, operating access, maintenance, and heat dissipation.

The weight of 65 kg must also be considered when designing the mounting support and handling arrangements.

4. Inspect Electrical Connections

Inspect the incoming and outgoing terminals, busbar connections, and mounting surfaces before installation.

Connection surfaces must be clean and properly prepared. Tightening torque, conductor size, and connection accessories should follow the manufacturer’s specifications.

Incorrect connections can result in overheating, contact resistance, and equipment damage.

5. Verify Protection Coordination

The selected protection unit and settings should be coordinated with upstream and downstream protective devices.

Engineers should evaluate overload settings, short-circuit protection, short-time delay, ground-fault protection where applicable, and selectivity requirements.

Protection settings must be based on a documented electrical study rather than assumptions based solely on the 1000 A frame rating.

6. Perform Commissioning Tests

Before energizing the installation, qualified personnel should verify the mechanical condition, mounting, electrical connections, control wiring, and protection configuration.

Commissioning should include appropriate insulation, functional, mechanical, and protection-system checks according to the manufacturer’s requirements and applicable standards.

All test results and protection settings should be recorded for future maintenance.

Compatible System Components

The NW10N1 operates as part of a complete low-voltage power distribution assembly. The following components may be used in a compatible installation, depending on the system design.

Component Function Integration Considerations
Compatible MasterPact NW control unit Provides protection functions and trip control Must be selected according to the breaker configuration
Current sensors Measure current for protection functions Confirm the correct sensor rating and compatibility
Electrical operating mechanism Supports remote or electrical operation Verify the required accessory configuration
Auxiliary contacts Provide breaker status signals Check contact ratings and control-circuit requirements
Shunt trip accessory Enables remote electrical tripping Confirm control voltage and accessory compatibility
Undervoltage release Trips or prevents closing under specified voltage conditions Select the correct voltage and operating arrangement
Switchboard busbars Carry current between distribution sections Verify current rating, fault withstand, and connection dimensions
Protection relay or monitoring system Supports system-level protection and monitoring Coordinate with the overall protection architecture
Grounding system Provides the required protective earthing arrangement Follow applicable electrical standards

The components listed above are examples of equipment that may be required in a complete installation. They are not necessarily included with the NW10N1 breaker frame.

Alternative Models and Replacement Considerations

The MasterPact NW family includes several frame ratings and breaking-performance classes. A replacement should be selected according to electrical requirements rather than physical appearance alone.

Related Model General Difference Replacement Considerations
NW08N1 800 A frame, N1 performance Lower frame rating; verify load requirements
NW10N1 1000 A frame, N1 performance Original model reference
NW10H1 1000 A frame, higher breaking-performance class Higher interrupting capacity; verify configuration
NW10H2 1000 A frame, higher breaking-performance class Confirm system fault-current requirements
NW12N1 1250 A frame, N1 performance Higher frame rating; not automatically interchangeable
NW16N1 1600 A frame, N1 performance Larger frame rating and different installation requirements

When replacing an existing NW10N1, verify:

  • Frame rating and sensor rating.
  • Number of poles.
  • Fixed or drawout mounting arrangement.
  • Rated operational voltage.
  • Ultimate and service breaking capacities.
  • Short-time withstand rating.
  • Control-unit type and protection functions.
  • Electrical operating accessories.
  • Auxiliary contacts and communication requirements.
  • Terminal and busbar arrangements.
  • Dimensions, weight, and switchboard compatibility.

A breaker with a higher breaking capacity or current rating is not necessarily a direct replacement. The replacement must be compatible with the complete electrical distribution system.

Key Advantages

High-Current Distribution Capability

The 1000 A frame rating makes the NW10N1 suitable for appropriately designed high-capacity low-voltage distribution systems.

Short-Circuit Protection Performance

The N1 performance class provides a published 42 kA ultimate breaking capacity at 440 V AC, subject to the applicable operating conditions and configuration.

Four-Pole Configuration

The four-pole arrangement supports switching of three phases and neutral where required by the electrical system design.

Industrial Power Distribution Application

The MasterPact NW series is designed for demanding power distribution environments, including industrial switchboards and large electrical installations.

Protection Coordination Capability

When equipped with a suitable control unit and correctly configured protection settings, the breaker can participate in coordinated protection systems.

Fixed-Mount Installation

The identified configuration uses fixed mounting, allowing integration into a compatible switchboard designed for the corresponding breaker dimensions and connections.

Established MasterPact Platform

The MasterPact NW family is used in a range of industrial and commercial power distribution applications. Accurate model identification supports maintenance, replacement, and spare-parts planning.

Technical FAQs

1. What is the Schneider Electric NW10N1?

The NW10N1 is a MasterPact NW air circuit breaker frame designed for low-voltage power distribution protection. The identified configuration is rated for a 1000 A frame and uses the N1 breaking-performance class.

2. What is the rated current of the NW10N1?

The frame rating is 1000 A. The actual protection setting and operating configuration depend on the selected control unit and sensor arrangement.

3. What is its short-circuit breaking capacity?

The published N1 ultimate short-circuit breaking capacity is 42 kA at 440 V AC. Engineers should verify the complete rating table for the actual operating voltage.

4. Is the NW10N1 a three-pole or four-pole breaker?

The identified Schneider Electric configuration is a four-pole fixed-mounted breaker frame. Other configurations in the MasterPact NW family may differ, so the full product description should be checked before ordering.

5. Does the NW10N1 include a control unit?

The identified configuration is supplied without a control unit. The appropriate control and protection equipment must be selected according to the application.

6. What is the difference between fixed and drawout circuit breakers?

A fixed breaker is mounted directly into the switchboard arrangement. A drawout breaker uses a withdrawable installation system that allows the breaker to be moved between connected, test, and disconnected positions where supported.

These arrangements have different mounting dimensions, weights, accessories, and maintenance procedures.

7. What are the dimensions and weight of the NW10N1?

The listed dimensions are 352 × 537 × 297 mm, and the weight is approximately 65 kg for the identified fixed-mounted four-pole configuration.

8. Can the NW10N1 be used in a generator system?

It may be used in a compatible generator distribution arrangement if the rated current, voltage, fault-current performance, control configuration, and protection coordination meet the system requirements.

9. What standards apply to this circuit breaker?

The identified product data references IEC 60947-1 and IEC 60947-2, which cover general rules and circuit-breaker requirements for low-voltage switchgear and controlgear.

10. What should be checked before purchasing an NW10N1?

Verify the full model designation, pole configuration, mounting type, frame rating, breaking capacity, control-unit status, sensor configuration, accessories, physical condition, and test documentation.

For used or surplus units, request clear nameplate photographs and confirmation of mechanical and electrical testing.

Procurement and Maintenance Recommendations

When purchasing the Schneider Electric NW10N1, verify that the supplier is offering the intended MasterPact NW configuration. The description should clearly identify the four-pole fixed-mounted arrangement and whether the control unit, sensors, and operating accessories are included.

For replacement projects, compare the complete product configuration with the existing breaker. Confirm the frame rating, short-circuit performance, control-unit compatibility, current sensor, connection arrangement, and switchboard dimensions.

For used or refurbished circuit breakers, request photographs of the nameplate, terminals, operating mechanism, and visible internal components where inspection is permitted. Ask for relevant test records and confirm the condition of the contacts, mechanical mechanism, and protective accessories.

Routine maintenance should follow Schneider Electric’s instructions and the applicable electrical safety requirements. Maintenance may include visual inspection, mechanical operation checks, connection inspection, cleaning, and verification of protection functions.

Because this is a 65 kg power distribution component, suitable lifting equipment and handling procedures should be used during installation and removal. Work must be carried out by qualified personnel with the equipment safely isolated.

Conclusion

The Schneider Electric NW10N1 MasterPact NW Air Circuit Breaker is a 1000 A frame circuit breaker designed for high-capacity low-voltage power distribution systems. Its N1 breaking-performance class provides a rated ultimate short-circuit breaking capacity of 42 kA at 440 V AC.

The identified configuration is a four-pole, fixed-mounted breaker frame supplied without a control unit. Its dimensions are 352 × 537 × 297 mm, with a listed weight of 65 kg.

For industrial power distribution maintenance and replacement projects, confirming the control-unit configuration, sensor rating, pole arrangement, and short-circuit requirements is essential. Correct selection and installation help ensure that the breaker is suitable for the electrical system in which it operates.