The HIMA F3417A is a 4-channel relay amplifier module designed for safety-instrumented systems. Part of the Planar F series, it conditions discrete input signals and drives safety relays or external devices. With galvanic isolation between each channel and a compact DIN-rail mount form factor, the F3417A ensures reliable, low-latency switching of critical shutdown and alarm circuits.
Parameter | Specification |
---|---|
Model Number | F3417A |
Series | Planar F |
Channels | 4 isolated relay outputs |
Output Type | SPDT safety relays |
Contact Rating | 8 A @ 250 V AC / 30 V DC |
Input Voltage Range | 24 V DC ±10% |
Response Time | < 10 ms |
Isolation Voltage | 1 500 V AC channel-to-channel/backplane |
Mounting | DIN-rail |
Dimensions (W×H×D) | 120 × 100 × 80 mm |
Weight | 0.50 kg |
Operating Temperature Range | –20 °C to +70 °C |
Status Indicators | LED per channel (OK/Trip) |
Safety Shutdown Circuits: Drives final element relays in emergency shutdown sequences.
Alarm and Notification: Activates local alarms and fault indication panels.
Interlock Logic: Implements safety interlocks for pumps, valves, and compressors.
Redundant Architectures: Used in dual or triple-channel safety loops for functional safety.
Process Skids and OEM Panels: Integrated into packaged equipment requiring safety outputs.
High Channel Isolation
Galvanic separation prevents cross-channel faults and ensures safe operation.
Fast Response
Sub-10 ms switching time supports rapid execution of safety functions.
Compact Footprint
DIN-rail mount module at 120 × 100 × 80 mm conserves control cabinet space.
Robust Relay Outputs
8 A contact rating accommodates a wide range of actuators without external relays.
Clear Diagnostics
Individual LEDs per channel provide immediate status on OK versus trip conditions.
HIMA is a specialist in safety instrumentation, renowned for delivering high-integrity, certified solutions for critical process industries worldwide.
The F3417A belongs to HIMA’s Planar F series of functional safety modules—compact, modular components designed for SIL-3 applications in process automation.
Model | Function | Channels | Contact Rating | Dimensions (mm) | Weight (kg) |
---|---|---|---|---|---|
F3417A | Relay Amplifier | 4 outputs | 8 A @ 250 V AC / 30 V DC | 120 × 100 × 80 | 0.50 |
F3416A | 8-Channel Relay Amplifier | 8 outputs | 5 A @ 250 V AC | 120 × 100 × 80 | 0.60 |
F3420A | Digital Input Module | 16 inputs | 24 V DC | 120 × 100 × 80 | 0.55 |
F3414A | Analog Input Module | 4 channels | 4–20 mA | 120 × 100 × 80 | 0.52 |
F3430A | Safety Logic Solver | – | CPU/Safety controller | 120 × 100 × 80 | 0.75 |
Model | Function | Key Feature | Dimensions (mm) | Weight (kg) |
---|---|---|---|---|
F3425A | 4-Channel Analog Output | 4–20 mA outputs | 120 × 100 × 80 | 0.58 |
F3412A | 16-Channel Digital Output | Transistor outputs | 120 × 100 × 80 | 0.65 |
F3410A | 32-Channel Digital Input | High-density inputs | 120 × 100 × 80 | 0.70 |
F3450A | Safety Communication Module | PROFIBUS DP interface | 120 × 100 × 80 | 0.68 |
F3460A | Power Supply Module | Redundant 24 V DC | 120 × 100 × 80 | 0.80 |
Q1: What safety integrity level is the F3417A certified for?
A1: It is certified for SIL-3 applications under IEC 61508 and IEC 61511 standards.
Q2: Can I mount multiple F3417A modules side by side on a single DIN rail?
A2: Yes, the 120 mm width allows up to six modules per standard 600 mm rail.
Q3: How do I test individual relay channels?
A3: Use the front-panel test input or cycle power to observe LED trip indication.
Q4: What is the expected relay lifetime?
A4: Contacts are rated for 100,000 mechanical operations and 50,000 electrical switching cycles.
Q5: Can outputs drive both AC and DC loads?
A5: Yes, contacts support up to 250 V AC and 30 V DC at 8 A.
Q6: Is there built-in short-circuit protection?
A6: Yes, each channel includes self-monitoring to detect welded contacts or shorts.
Q7: How quickly does the module react to an input fault?
A7: Total fault-to-trip response time is under 10 milliseconds.
Q8: What diagnostics interface is available?
A8: LEDs indicate OK or trip status per channel; advanced diagnostics via the safety controller.
Q9: How is the module powered?
A9: It draws 24 V DC from the Planar backplane power bus; no external supply is required.
Q10: Where can I find detailed wiring diagrams?
A10: Full installation and wiring instructions are provided in HIMA’s technical manual F3417A-UM.
Authenticity guarantee
All product specifications are original and authentic imported products. We have an annual sales volume of 300 million yuan, and we only produce original and authentic products. All customers who cooperate with us directly online can enjoy low discounts.
Free warehouse
We have a complete range of product models, 80% of conventional models are in stock, and we have established channels in Asia, Africa, North America, South America, and Europe, effectively shortening the order processing time and satisfying customers in a timely manner.
Technical Team
Fast delivery. Spot goods can be shipped on the same day, and the delivery time transaction is 20% faster than that of peers on average, with a delivery time accuracy rate of 99%.
Thoughtful after-sales service
24-hour after-sales service guarantee team, professional and standardized management service system.