The HIMA F3405 is a high-integrity relay amplifier module designed for the Planar F series safety system. It provides galvanically isolated signal conditioning and relay driving for safety-critical applications, ensuring that field input devices can reliably trigger safety logic and initiate safe shutdown sequences. Its compact design combines robust electronics with diagnostics to simplify integration and maintenance in industrial environments.
Emergency Shutdown (ESD): Driving solenoid valves and shutdown relays in oil & gas, chemical, and power plants.
Safety Interlocks: Amplifying contact outputs from E-stop buttons and door switches to safety logic channels.
Fire & Gas Systems: Interface between gas detectors or flame sensors and safety controller inputs.
Critical Valve Control: Ensuring that fail-safe valves receive reliable trip signals in lost-power or fault conditions.
Redundant Safety Architectures: Serving as the interface module in dual-channel or three-channel safety loops.
Brand: HIMA Paul Hildebrandt GmbH
Series: Planar F Safety System
HIMA’s Planar F series is a modular, scalable safety platform used worldwide in industries where SIL 3/SIL 4 functional safety is mandatory.
High Integrity: Meets IEC 61508 SIL 3 and IEC 61511 requirements for safety-related control.
Galvanic Isolation: 4 kV isolation between input, output, and power rails prevents cross-channel faults.
Built-In Diagnostics: Monitors coil health and internal electronics, reporting faults to the safety controller.
Compact Footprint: Saves cabinet space without sacrificing performance or safety redundancy.
Hot-Swap Capability: Can be replaced during operation without shutting down the entire safety loop (with appropriate procedures).
Specification | Details |
---|---|
Model Number | F3405 |
Function | Relay amplifier for safety outputs |
Input Signal | 24 V DC control voltage |
Output | 2 × SPDT safety relays, 5 A @ 250 V AC / 30 V DC |
Isolation Voltage | 4 kV AC input-to-output and channel-to-channel |
Response Time | < 10 ms |
Diagnostics | Coil voltage monitoring; internal short-circuit detection |
Operating Temperature | –20 °C to +70 °C |
Storage Temperature | –40 °C to +85 °C |
Relative Humidity | 5 % to 95 % RH (non-condensing) |
Dimensions (W × H × D) | 198 × 162 × 108 mm |
Weight | 1.2 kg |
Mounting | DIN rail TS35 |
Model | Function | Key Parameter |
---|---|---|
F3305 | Single relay amplifier, 24 V DC input | 1 × SPDT, 5 A output |
F3410 | Dual relay amplifier with test function | 2 × SPDT, built-in coil test |
F3505 | High-capacity relay amplifier | 2 × DPDT, 10 A output |
F3202 | Safety input module for contact sensors | 8 × digital inputs |
F3705 | Analog I/O interface for pressure sensors | 4–20 mA input/output |
Model | Description | Application |
---|---|---|
F2233 | Dual-channel analog input module | SIL 3 pressure monitoring |
F3281 | Safety logic solver, 2-channel CPU | SIL 3/SIL 4 safety controller |
F5105 | Fast input module for high-speed sensors | Vibration and speed monitoring |
F7205 | SIL 3 voting module for triple-channel loops | Redundant safety voting |
F7101 | Safe Ethernet gateway | Industrial network isolation |
Q: What safety standards does the F3405 comply with?
A: It is certified to IEC 61508 SIL 3 and IEC 61511 for functional safety in process control.
Q: How many relays does the F3405 drive?
A: Two SPDT safety relays, each rated 5 A at 250 V AC or 30 V DC.
Q: Can the F3405 be replaced without shutting down the system?
A: Yes, it supports hot-swap in redundant safety loops when following proper isolation procedures.
Q: What diagnostic features are included?
A: The module monitors coil voltage and detects internal faults, reporting errors to the safety controller.
Q: What is the module’s response time?
A: Typical response time is under 10 ms from input actuation to relay output.
Q: How is the module mounted?
A: It clips onto a standard TS35 DIN rail and connects via a front-mounted bus connector.
Q: What environmental conditions can it withstand?
A: Operating temperature –20 °C to +70 °C and up to 95 % non-condensing humidity.
Q: Is there galvanic isolation between channels?
A: Yes—4 kV AC isolation between input, output, and among channels to prevent fault propagation.
Q: Does it support redundant architectures?
A: It is designed for dual-channel or three-channel safety loop configurations in the Planar F system.
Q: What routine maintenance is required?
A: Visual inspection of relay contacts and periodic functional testing via the safety controller’s diagnostics.
Authenticity guarantee
All product specifications are original and authentic imported products. We have an annual sales volume of 300 million yuan, and we only produce original and authentic products. All customers who cooperate with us directly online can enjoy low discounts.
Free warehouse
We have a complete range of product models, 80% of conventional models are in stock, and we have established channels in Asia, Africa, North America, South America, and Europe, effectively shortening the order processing time and satisfying customers in a timely manner.
Technical Team
Fast delivery. Spot goods can be shipped on the same day, and the delivery time transaction is 20% faster than that of peers on average, with a delivery time accuracy rate of 99%.
Thoughtful after-sales service
24-hour after-sales service guarantee team, professional and standardized management service system.