The Schneider NS1600NA ComPacT Switch Disconnector is a high-current electrical switching device designed for low-voltage power distribution systems. Manufactured by Schneider Electric, it belongs to the ComPacT NS family and is intended for controlling and isolating electrical circuits in industrial and commercial installations.
With a rated operational current of 1600 A and an operational voltage of up to 690 V AC, the NS1600NA is designed for demanding power distribution applications. Its robust construction supports installation in main distribution boards, industrial switchboards, and other electrical infrastructure where reliable circuit isolation is required.
An important distinction is that the NS1600NA is a switch disconnector rather than a conventional automatic circuit breaker with an integrated overcurrent trip unit. Its primary function is to establish, carry, and interrupt current under specified operating conditions and provide electrical isolation. Separate upstream protective devices are required to provide appropriate overload and short-circuit protection.
The ComPacT NS1600NA is available in different configurations, including fixed and withdrawable versions, as well as manually and electrically operated arrangements. The exact configuration should be checked before ordering because these options affect installation, operation, and accessory compatibility.
The device is suitable for integration into industrial electrical distribution systems where high-current switching and isolation are required. Its compact structural design, high current-carrying capacity, and compatibility with suitable distribution accessories make it a useful component in electrical infrastructure projects.
| Parameter | Specification |
|---|---|
| Brand | Schneider Electric |
| Model | NS1600NA |
| Product Series | ComPacT NS |
| Product Type | Switch Disconnector |
| Product Category | 1600A Electrical Switching Device |
| Rated Operational Current | 1600 A |
| Conventional Free-Air Thermal Current | 1600 A at 60°C |
| Rated Operational Voltage | Up to 690 V AC |
| Network Frequency | 50/60 Hz |
| Number of Poles | 4P configuration available |
| Rated Insulation Voltage | Up to 1000 V AC |
| Rated Impulse Withstand Voltage | 8 kV |
| Short-Time Withstand Current | 25 kA for 0.5 seconds |
| Short-Circuit Making Capacity | 52 kA peak at 690 V AC |
| Mechanical Durability | 6000 operating cycles |
| Electrical Durability | 1000 cycles at 440 V AC |
| Connection Pitch | 115 mm |
| Mounting Configuration | Fixed or withdrawable, depending on version |
| Operating Method | Manual or electrical, depending on version |
| Dimensions | 327 × 280 × 147 mm |
| Weight | 18 kg |
| Application | Industrial power distribution and circuit isolation |
Note: The NS1600NA is a switch disconnector. Electrical ratings and operating characteristics vary by configuration. Confirm the exact pole arrangement, mounting type, operating mechanism, and connection accessories before installation.
The Schneider NS1600NA is designed to control and isolate high-current electrical circuits. It provides a switching mechanism that allows an operator or electrical control system to change the connection state of a distribution circuit.
The NS1600NA is rated for 1600 A operational current under its specified utilization conditions. Its contacts and internal current paths are designed to carry substantial electrical current in industrial distribution systems.
The switching mechanism allows the connected circuit to be opened or closed according to the device’s operating specifications.
One of the main functions of a switch disconnector is to isolate an electrical circuit during maintenance or equipment servicing.
When operated correctly and in accordance with the applicable procedures, it separates the connected circuit from its supply. This supports safe maintenance activities when combined with appropriate lockout, verification, and grounding procedures.
Four-pole versions provide switching across three phase conductors and the neutral conductor.
This configuration can be useful in distribution systems where the neutral conductor must also be switched. The exact neutral arrangement and installation requirements should be confirmed for the selected device.
The NS1600NA is designed to withstand specified short-duration current conditions. Published characteristics include a short-time withstand current of 25 kA for 0.5 seconds.
This capability is important when coordinating the switch disconnector with upstream protective equipment. The protective device must clear a fault within the permitted withstand period.
Depending on the selected version, the NS1600NA can use a manual operating mechanism or an electrical operating mechanism.
Manual operation is suitable for installations where local switching is required. Electrically operated configurations can be incorporated into systems requiring remote switching or coordinated operation.
The operating mechanism must be identified before selecting replacement components or planning electrical control wiring.
The NS1600NA can serve as a major switching and isolation component in industrial electrical distribution infrastructure.
In a main distribution board, the switch disconnector can be used to control or isolate a high-current distribution section. This allows maintenance personnel to disconnect designated electrical sections when required.
Large industrial switchboards distribute electrical power to production equipment, motor control centers, and auxiliary systems. The NS1600NA can be installed as part of an appropriately designed switching arrangement.
Industrial facilities may need to isolate individual distribution sections during maintenance, inspection, or equipment modification. The switch disconnector provides a dedicated switching point for this purpose.
Because the NS1600NA is not an automatic overcurrent circuit breaker, it must be coordinated with suitable upstream protection.
The overall electrical design should consider fault current levels, protective-device operating times, cable ratings, and the switch disconnector’s short-time withstand characteristics.
Large manufacturing facilities require reliable electrical distribution equipment to supply production machinery and supporting infrastructure.
The NS1600NA can be used in high-current distribution sections where switching and isolation are required.
Manufacturing plants often contain multiple electrical distribution zones serving production lines, processing equipment, and auxiliary systems.
The device can provide an isolation point for a designated distribution circuit, helping maintenance teams organize electrical shutdown procedures.
Large commercial buildings and infrastructure facilities may use high-current switchboards to distribute electrical power.
The NS1600NA can be considered for suitable distribution applications where its current and voltage ratings meet the system requirements.
Motor control centers distribute power to multiple motor starters, drives, and control systems. A suitable switch disconnector can serve as an isolation component for a distribution section supplying these installations.
The protective coordination between the switch disconnector and downstream motor protection devices must be properly engineered.
Industrial facilities often operate auxiliary electrical systems for ventilation, cooling, lighting, and other essential services.
The NS1600NA can be used in appropriate high-current distribution arrangements where reliable switching and isolation are required.
Correct installation is essential for electrical safety and reliable operation.
Before installation, confirm that the system voltage, operating current, frequency, and available fault current are compatible with the selected NS1600NA configuration.
The 1600 A rating should not be treated as a universal rating under every operating condition. Ambient temperature, installation arrangement, conductor connections, and utilization category must be considered.
The NS1600NA is available in different mounting arrangements. Confirm whether the supplied device is fixed or withdrawable.
The switchboard must provide suitable mounting support, connection spacing, and clearance for operation and maintenance.
Verify the terminal arrangement, connection pitch, conductor dimensions, and busbar requirements.
Electrical connections must be tightened according to the manufacturer’s specified torque values. Incorrect connection practices can cause overheating and damage.
The NS1600NA does not replace the protective function of an automatic circuit breaker or appropriately selected fuse system.
Ensure that the upstream protective device provides adequate overload and short-circuit protection for the complete installation.
Confirm whether the device uses manual or electrical operation.
For electrically operated versions, verify the control voltage, operating mechanism, and compatibility of the control accessories.
Before energizing the equipment, inspect the mounting arrangement, electrical connections, insulation condition, and mechanical operation.
Verify that the switching mechanism operates correctly and that the associated protective equipment is coordinated with the installation.
All commissioning and maintenance activities should be carried out by qualified electrical personnel.
The NS1600NA is normally integrated into a wider electrical distribution system.
| Component | Function | Integration Considerations |
|---|---|---|
| Main distribution busbar | Distributes electrical power | Verify current capacity and connection dimensions |
| Upstream circuit breaker | Provides overload and short-circuit protection | Coordinate protective ratings and clearing times |
| Electrical operating mechanism | Enables electrical switching | Confirm the exact NS1600NA configuration |
| Auxiliary contacts | Provide switching-status information | Check accessory compatibility |
| Control cabinet | Houses electrical distribution equipment | Ensure adequate space and mechanical support |
| Cable connections | Connect the device to the distribution system | Select suitable conductor sizes and terminals |
| Power monitoring equipment | Measures electrical operating conditions | Coordinate current and voltage measurement arrangements |
| Grounding system | Supports electrical safety | Follow applicable grounding standards |
Accessories and auxiliary components are not necessarily included with the basic switch disconnector. Confirm the exact supply configuration before ordering.
When replacing an NS1600NA, it is important to distinguish between a switch disconnector and a protective circuit breaker.
| Alternative Product Family | Main Consideration |
|---|---|
| Schneider ComPacT NS switch disconnectors | Compare current rating, pole arrangement, mounting type, and operating mechanism |
| Schneider ComPacT NS circuit breakers | Provide circuit protection functions, but are not automatically interchangeable |
| Schneider MasterPact circuit breakers | Suitable for certain high-current distribution applications, subject to engineering evaluation |
| Schneider ComPacT NS630b–NS1600 family | Compare frame configuration, electrical characteristics, and accessories |
| Other 1600 A industrial switch disconnectors | Verify utilization category, voltage rating, short-time withstand capacity, and dimensions |
Before purchasing a replacement, compare:
A replacement must satisfy the electrical and mechanical requirements of the original installation. A device with the same 1600 A rating may still have different switching characteristics or accessory requirements.
The 1600 A operational current rating makes the NS1600NA suitable for appropriately designed high-current distribution applications.
Its switching and isolation functions support maintenance and shutdown procedures in industrial electrical installations.
Different fixed and withdrawable configurations provide flexibility for various switchboard designs.
Manual and electrically operated versions can accommodate different operational requirements.
The ComPacT NS platform is designed for industrial and commercial power distribution environments.
Published electrical ratings support engineering evaluation and coordination with associated distribution equipment.
The Schneider NS1600NA is a 1600 A ComPacT NS switch disconnector designed for controlling and isolating electrical distribution circuits.
It is commonly listed in spare-parts catalogs under circuit breaker categories, but the NS1600NA designation refers to a switch disconnector. It should not be confused with an automatic circuit breaker equipped with an overcurrent trip unit.
Its rated operational current is 1600 A under the specified operating conditions.
The published rated operational voltage is up to 690 V AC at 50/60 Hz.
Four-pole versions are available. Other configurations may also exist, so the exact product version should be confirmed.
The manufacturer-listed dimensions are 327 × 280 × 147 mm.
The published net weight is approximately 18 kg.
No. The switch disconnector itself does not provide the automatic overload and short-circuit tripping function of a protective circuit breaker. Suitable upstream protection must be provided.
Yes. Electrically operated versions are available, although the operating mechanism depends on the exact configuration.
Check the full product designation, current and voltage ratings, pole configuration, mounting arrangement, operating mechanism, connection dimensions, and associated accessories. Also verify that the replacement provides the required isolation and switching characteristics.
When purchasing the Schneider NS1600NA, confirm the complete product designation and configuration. The ComPacT NS1600NA family includes different versions, and a basic switch disconnector should not be confused with a complete circuit breaker assembly.
For replacement projects, verify the number of poles, mounting type, operating mechanism, and terminal arrangement. If the existing installation uses electrical operation, confirm that the replacement includes the correct mechanism and compatible control accessories.
For used or refurbished equipment, inspect the operating mechanism, contact condition, terminal connections, insulation surfaces, and visible signs of overheating or mechanical damage. Request photographs of the nameplate and relevant connection points before ordering.
During maintenance, follow the manufacturer’s inspection and operating procedures. Electrical isolation must be verified before work begins, and all servicing should be performed by qualified personnel.
Because this device is intended for high-current distribution systems, correct protective coordination is particularly important. Confirm that upstream protective equipment can clear faults within the permitted withstand limits.
The Schneider NS1600NA ComPacT 1600A Switch Disconnector is designed for high-current electrical distribution and circuit isolation in industrial and commercial installations. With a rated operational current of 1600 A, an operational voltage of up to 690 V AC, and a four-pole configuration available, it provides a switching solution for appropriately engineered power distribution systems.
Its dimensions of 327 × 280 × 147 mm and net weight of 18 kg make it suitable for integration into compatible industrial switchboards.
For procurement and replacement projects, verifying the exact configuration is essential. Engineers should distinguish the NS1600NA switch disconnector from automatic protective circuit breakers and ensure that suitable upstream overload and short-circuit protection is provided.