The Schneider Electric NS1600N ComPacT Circuit Breaker is a high-current circuit protection device designed for low-voltage power distribution systems. Belonging to the ComPacT NS630b–1600 product family, it is intended for industrial and commercial electrical installations where reliable switching, circuit isolation, and short-circuit protection are essential.
Circuit breakers play an important role in electrical distribution networks. They help protect cables, busbars, connected equipment, and downstream circuits from abnormal current conditions. When an overload or short circuit occurs, the appropriate protection unit detects the fault and initiates circuit interruption to limit potential damage.
The NS1600N has a rated current of 1600 A and a rated operational voltage of up to 690 V AC. Its N breaking-capacity class provides a rated ultimate short-circuit breaking capacity of 50 kA at 380/415 V AC, subject to the applicable product configuration and installation conditions.
The product is part of the ComPacT NS630b–1600 family, which is designed for high-current power distribution applications. Depending on the selected reference, the equipment may be supplied as a basic circuit-breaker frame or as a more complete assembly with a specified trip unit and operating mechanism.
This distinction is important when purchasing the NS1600N. The model designation alone does not establish whether the unit is fixed or withdrawable, manually or electrically operated, or equipped with a particular electronic trip unit. Buyers should verify the complete product reference and nameplate before selecting a replacement.
With its high-current rating and industrial distribution application, the NS1600N is suitable for appropriately engineered main distribution boards, power control centers, and other low-voltage electrical installations.
| Parameter | Specification |
|---|---|
| Brand | Schneider Electric |
| Product Series | ComPacT NS |
| Model | NS1600N |
| Product Type | Low-Voltage Circuit Breaker |
| Product Family | ComPacT NS630b–1600 |
| Rated Current | 1600 A |
| Rated Operational Voltage | Up to 690 V AC |
| Network Type | AC |
| Network Frequency | 50/60 Hz |
| Breaking Capacity Class | N |
| Ultimate Short-Circuit Breaking Capacity | 50 kA at 380/415 V AC |
| Rated Insulation Voltage | 800 V AC for the documented configuration |
| Rated Impulse Withstand Voltage | 8 kV for the documented configuration |
| Utilization Category | Category B |
| Number of Poles | Depends on the complete product reference; 3P and 4P versions exist |
| Trip Unit | Depends on the selected configuration |
| Operating Mechanism | Manual or electrical, depending on reference |
| Mounting Type | Fixed or withdrawable, depending on reference |
| Dimensions Provided | 224 × 210 × 182 mm |
| Weight Provided | 14 kg |
| Typical Application | Industrial low-voltage power distribution |
Important: The NS1600N designation covers multiple configurations. The electrical and mechanical details of the complete unit must be confirmed using its full catalog number. The dimensions above are the supplied listing values and correspond to a documented fixed-frame configuration.
The Schneider Electric NS1600N is designed to provide switching and circuit protection in low-voltage electrical distribution systems. Its operation involves detecting abnormal current conditions through the selected protection arrangement and interrupting the circuit when the applicable trip conditions are met.
An overload occurs when a circuit carries more current than its intended operating level for an extended period. This may result from excessive connected loads, equipment malfunction, or changes in operating conditions.
When equipped with a suitable protection unit, the NS1600N can detect overload conditions and initiate circuit interruption according to the configured protection characteristics.
The correct protection settings must coordinate with the ratings of cables, busbars, transformers, and downstream equipment.
A short circuit can produce a very high fault current within a short period. Without appropriate protection, this current may cause severe thermal and mechanical stress to electrical equipment.
The NS1600N belongs to the N breaking-capacity class, with a rated ultimate short-circuit breaking capacity of 50 kA at 380/415 V AC for the documented product family.
The actual short-circuit protection performance must be assessed against the system’s prospective fault current and the complete breaker configuration.
A circuit breaker can be used to connect or disconnect an electrical circuit during normal operation, maintenance, or abnormal conditions.
Depending on the selected NS1600N reference, operation may be manual or electrical. Electrically operated configurations can support remote opening and closing when the required operating mechanism and control accessories are installed.
The ComPacT NS1600N family is designed for isolation in accordance with applicable IEC 60947-2 requirements for the documented configurations.
Isolation is important during maintenance because it allows electrical equipment to be separated from its power source. Safe work still requires the prescribed isolation, lockout, and verification procedures.
Certain NS1600N configurations use electronic MicroLogic trip units. These units provide protection functions according to their specific type.
For example, MicroLogic 2.0 configurations provide long-time and instantaneous protection functions, while other trip-unit versions may offer additional protection features.
The exact protection functions should always be confirmed from the installed trip-unit model rather than inferred from the NS1600N frame designation.
The NS1600N can serve as a main or feeder circuit breaker in industrial low-voltage distribution systems. Its position depends on the electrical architecture and the coordination requirements of the installation.
In a main distribution board, a high-current circuit breaker may be installed between the incoming power source and the main busbar system.
The breaker provides a means of controlling and protecting the incoming distribution circuit. Its rated current and short-circuit capacity must be coordinated with the transformer, supply network, busbars, and downstream protective devices.
The NS1600N may also be used as a feeder breaker supplying a large electrical load or a downstream distribution section.
In this arrangement, the breaker helps isolate the relevant feeder when a fault occurs. Protection coordination with downstream breakers is important to reduce unnecessary interruption to unaffected parts of the installation.
Industrial power control centers often contain circuit breakers, contactors, motor starters, metering devices, and protection equipment.
The NS1600N can form part of this electrical infrastructure when its ratings and physical configuration match the switchboard design.
When the appropriate trip unit and accessories are installed, the breaker may support additional monitoring or remote-control functions.
The availability of communication, measurement, and remote operation depends on the complete product configuration. These functions should not be assumed from the NS1600N designation alone.
The NS1600N is intended for high-current low-voltage distribution applications. Its suitability depends on the electrical system design, available fault current, load characteristics, and selected breaker configuration.
Large manufacturing facilities require reliable distribution of electrical power from transformers or incoming supply equipment to different production areas.
A 1600 A circuit breaker may be used in an appropriately designed main distribution board to provide switching and protection for the incoming or outgoing circuit.
Power control centers distribute electrical energy to motors, process equipment, and auxiliary systems.
The NS1600N can be considered for a suitable high-current feeder or distribution position where its voltage, current, breaking capacity, and mounting configuration meet the project requirements.
Industrial plants often operate production lines, compressors, pumps, fans, and other high-power equipment.
The breaker may be installed in the distribution infrastructure supplying these systems. Correct protection coordination helps limit the impact of electrical faults on production operations.
Large commercial buildings and infrastructure facilities may require high-current protection at main distribution or sub-distribution points.
The NS1600N may be suitable where the installation requires a 1600 A low-voltage circuit breaker and the system’s fault level falls within the selected configuration’s rated breaking capacity.
Industrial facilities frequently have auxiliary electrical systems for lighting, ventilation, cooling, water treatment, and other services.
A high-current circuit breaker may protect a distribution section supplying multiple auxiliary loads. The selection must account for the load profile and the required continuity of service.
Correct installation is essential for electrical safety, reliable switching, and effective fault protection.
The first step is to identify the complete product reference. NS1600N is a family designation, not a complete configuration identifier.
Confirm the following before installation:
A basic frame without a trip unit should not be treated as a fully configured protective circuit breaker.
Confirm that the installation voltage and frequency are within the product’s specified limits. The rated current must be suitable for the protected circuit and the connected load.
The system’s prospective short-circuit current must also be evaluated. The selected breaker must have adequate breaking capacity at the actual operating voltage.
The supplied dimensions are 224 × 210 × 182 mm. Verify these measurements against the exact product reference and manufacturer’s installation drawing before designing the switchboard.
Provide sufficient space for mounting, electrical connections, operating mechanisms, ventilation, and maintenance access.
For withdrawable versions, additional space and the correct cradle or chassis arrangement may be required.
Power connections must use conductors, busbars, terminals, and connection accessories suitable for the rated current and installation conditions.
Follow the manufacturer’s requirements for conductor preparation, terminal arrangement, tightening torque, and phase identification.
Incorrect connection practices may lead to overheating, loose connections, or equipment damage.
If an electronic trip unit is installed, verify the protection settings against the system study and coordination requirements.
Relevant parameters may include long-time protection, short-time protection, instantaneous protection, and ground-fault protection where supported by the selected unit.
Do not use generic settings without checking cable ratings, transformer characteristics, downstream protection, and the calculated fault level.
Before energizing the system, inspect the mechanical assembly, electrical connections, auxiliary circuits, and protection unit.
Where required, carry out manufacturer-recommended mechanical and electrical tests. Confirm that opening, closing, tripping, indication, and interlocking functions operate correctly.
Testing and commissioning should be performed by qualified personnel using approved procedures.
The NS1600N is generally installed as part of a complete low-voltage distribution assembly.
| Component | Function | Integration Considerations |
|---|---|---|
| Low-voltage switchboard | Houses and connects distribution equipment | Verify frame dimensions, mounting, and busbar arrangement |
| Main busbar system | Distributes electrical power | Confirm current rating, temperature rise, and short-circuit withstand |
| MicroLogic trip unit | Provides electronic protection functions | Select the correct trip-unit type and protection features |
| Motor operating mechanism | Enables electrical opening and closing | Required only for applicable electrically operated configurations |
| Auxiliary contacts | Provide breaker status signals | Verify contact ratings and control-circuit requirements |
| Shunt trip release | Enables remote electrical tripping | Confirm the correct accessory and control voltage |
| Undervoltage release | Trips or prevents closing under specified voltage conditions | Check the required voltage and operating characteristics |
| Current transformers or metering devices | Support electrical measurement | Confirm compatibility with the selected metering arrangement |
| Downstream circuit breakers | Protect individual feeders and loads | Coordinate protection settings and breaking capacities |
| Power monitoring system | Monitors distribution conditions | Communication and measurement accessories may be required |
The components listed above are examples of equipment used in circuit-breaker installations. They are not necessarily included with every NS1600N product reference.
When replacing an NS1600N, the selected alternative must match the electrical and mechanical requirements of the original installation.
| Alternative or Related Product | Replacement Considerations |
|---|---|
| Schneider Electric ComPacT NS1600N with matching reference | Preferred starting point for like-for-like replacement when the original configuration is available |
| Schneider Electric ComPacT NS1600N with a different trip unit | Requires checking protection functions, ratings, accessories, and settings |
| Schneider Electric ComPacT NS new-generation models | May be considered for modernization, subject to switchboard and electrical compatibility |
| Schneider Electric Masterpact air circuit breakers | May be suitable for certain main distribution applications, but usually require a broader engineering review |
| Other 1600 A low-voltage circuit breakers | Must meet the required voltage, breaking capacity, installation dimensions, and protection coordination |
Before selecting a replacement, compare:
A replacement with the same 1600 A current rating is not automatically interchangeable. Differences in breaking capacity, trip-unit characteristics, frame dimensions, and accessory arrangements can affect both safety and system operation.
The NS1600N is designed for distribution applications requiring a rated current of up to 1600 A, making it suitable for appropriately engineered industrial power systems.
The N breaking-capacity class provides a documented 50 kA ultimate short-circuit breaking capacity at 380/415 V AC.
The ComPacT NS family is designed for low-voltage electrical distribution applications in industrial and commercial environments.
The NS1600N family includes different configurations, allowing system designers to select suitable pole arrangements, operating mechanisms, mounting types, and protection units.
The documented product configurations support isolation in accordance with applicable IEC 60947-2 requirements.
The breaker can be incorporated into switchboards and power control centers when the selected frame, trip unit, and accessories match the installation design.
The NS1600N is a high-current circuit breaker in the ComPacT NS630b–1600 family. It is designed for low-voltage AC power distribution and has a rated current of 1600 A.
The documented rated operational voltage is up to 690 V AC at 50/60 Hz. The applicable rating must be confirmed for the complete product reference.
The N breaking-capacity class has a rated ultimate short-circuit breaking capacity of 50 kA at 380/415 V AC for the documented product family.
Both 3-pole and 4-pole configurations exist in the NS1600N family. The complete catalog number is needed to identify the exact version.
No. Some references are supplied as basic frames without a trip unit, while other references include specified MicroLogic protection units. Check the complete product reference before purchasing.
Certain configurations support electrical operation through a motor mechanism and the required control accessories. Manually operated versions do not automatically provide this capability.
A fixed breaker is mounted directly in the switchboard assembly. A withdrawable breaker is installed with a compatible chassis or cradle, allowing the breaker to be moved between designated positions for isolation and maintenance procedures.
It can be used in suitable industrial distribution applications when its voltage, current, breaking capacity, mounting arrangement, and protection settings meet the installation requirements.
Check the complete catalog number, pole count, trip unit, operating mechanism, mounting type, connection arrangement, accessories, and protection settings. Also verify that the replacement meets the system’s fault-current and coordination requirements.
The full Schneider Electric reference or a clear photograph of the product nameplate is required. This information helps identify the pole configuration, trip unit, operating mechanism, mounting type, and other options.
When purchasing the Schneider Electric NS1600N, buyers should verify the complete product reference rather than relying on the family designation alone.
For replacement projects, compare the original nameplate with the proposed unit. Confirm whether the breaker is supplied with a trip unit, operating mechanism, auxiliary contacts, and other required accessories. A basic frame without a protection unit may require additional components before it can function as the intended protective device.
For used or refurbished equipment, inspect the main contacts, operating mechanism, terminals, insulation surfaces, trip unit, and accessory compartments. Request available test records and confirm the condition of the product before installation.
During routine maintenance, follow the manufacturer’s inspection and testing procedures. Check mechanical operation, connection integrity, signs of overheating, and the condition of auxiliary circuits. Protection settings should be reviewed whenever the electrical distribution system changes.
For critical distribution equipment, maintenance and replacement work should be performed by qualified electrical personnel. The breaker should be selected and commissioned according to the system protection study and applicable electrical standards.
The Schneider Electric NS1600N ComPacT Circuit Breaker is a high-current low-voltage protection device designed for industrial and commercial electrical distribution systems. With a rated current of 1600 A and an N-class ultimate short-circuit breaking capacity of 50 kA at 380/415 V AC, it can support appropriately engineered main and feeder distribution applications.
The NS1600N family includes different mechanical and electrical configurations. Correct identification of the complete catalog number, trip unit, operating mechanism, and mounting arrangement is essential when purchasing, maintaining, or replacing this circuit breaker.