• Schneider NS1600H Circuit Breaker
  • Schneider NS1600H Circuit Breaker
  • Schneider NS1600H Circuit Breaker
  • Schneider NS1600H Circuit Breaker
Product Overview The Schneider Electric NS1600H ComPacT Circuit Breaker is a high-capacity low-voltage circuit breaker designed for industrial power distribution systems, electrical switchboards, and la……
Schneider NS1600H Circuit Breaker
  • Schneider
  • NS1600H
  • Circuit Breaker
  • France
  • 327 x 210 x 147 mm
  • 14 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 27

Our advantage

Schneider NS1600H Circuit Breaker

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Schneider NS1600H Circuit Breaker

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Schneider NS1600H Circuit Breaker

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Schneider NS1600H Circuit Breaker

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Schneider Electric NS1600H ComPacT Circuit Breaker is a high-capacity low-voltage circuit breaker designed for industrial power distribution systems, electrical switchboards, and large commercial installations. It belongs to the ComPacT NS630b–1600 product family and is intended for applications where dependable switching, isolation, and short-circuit protection are essential.

Circuit breakers are important components in electrical distribution networks. They protect downstream equipment and conductors by interrupting current when abnormal electrical conditions occur. In large installations, a circuit breaker’s rated current, short-circuit breaking capacity, trip-unit characteristics, and coordination with upstream and downstream protective devices must be carefully evaluated.

The NS1600H is associated with a 1600 A rated-current frame and an H-class breaking-capacity configuration. Schneider Electric product information identifies a 70 kA ultimate short-circuit breaking capacity at 415 V AC for the relevant 3-pole configuration. The device family supports operating voltages up to 690 V AC and 50/60 Hz systems, subject to the specific product reference and electrical ratings.

The NS1600H name alone does not identify every feature of a complete breaker. Some configurations are supplied as basic frames without a trip unit, while other versions include electronic MicroLogic protection units. Fixed and withdrawable versions, manual and electrical operating mechanisms, and different pole arrangements may also be available.

For this reason, the complete reference number and nameplate should always be checked before ordering a replacement. The trip unit and accessories determine important functions such as overload protection, short-time protection, instantaneous protection, metering, remote operation, and signaling.

The NS1600H is suitable for appropriately engineered power distribution applications where high current capacity and reliable circuit interruption are required. It can be installed in industrial switchboards, main distribution panels, and other low-voltage electrical systems after the electrical design and protection coordination have been verified.

Technical Specifications

Parameter Specification
Brand Schneider Electric
Product Series ComPacT NS
Model / Frame NS1600H
Product Type Low-Voltage Circuit Breaker
Device Application Power Distribution
Rated Frame Current 1600 A
Rated Operational Voltage Up to 690 V AC, configuration dependent
Rated Frequency 50/60 Hz
Typical Breaking Capacity 70 kA at 415 V AC, H-class configuration
Ultimate Short-Circuit Breaking Capacity Voltage dependent; refer to the exact product reference
Service Short-Circuit Breaking Capacity Configuration and voltage dependent
Short-Time Withstand Current Up to 19.2 kA for 1 second in documented configurations
Number of Poles 3P or 4P, depending on configuration
Trip Unit Configuration dependent; MicroLogic options available
Mounting Type Fixed or withdrawable, depending on configuration
Operating Mechanism Manual or electrical, depending on configuration
Rated Insulation Voltage Up to 800 V AC in documented fixed configurations
Rated Impulse Withstand Voltage 8 kV in documented configurations
Dimensions Provided 327 × 210 × 147 mm
Weight Provided 14 kg
Typical Applications Industrial distribution, switchboards, main power panels

Important: The dimensions and weight above are the supplied listing values. Schneider Electric publishes different physical dimensions and weights for different pole counts, mounting arrangements, and trip-unit configurations. Confirm the complete reference number and actual product before finalizing installation or shipping details.

Function and Working Principle

The NS1600H is designed to perform switching, isolation, and circuit-protection functions in low-voltage electrical distribution systems. Its operation depends on the installed trip unit and operating mechanism.

1. Overload Protection

An overload occurs when a circuit carries more current than its intended operating level for an extended period. Excessive current can cause conductors, terminals, and connected equipment to overheat.

When fitted with an appropriate protection unit, the NS1600H can detect overload conditions and initiate a trip according to the configured protection characteristics. Electronic trip units can provide adjustable long-time protection settings, allowing engineers to coordinate the breaker with the rated capacity of downstream equipment.

The correct current setting must be selected according to the conductor rating, load requirements, and electrical protection design. A 1600 A frame rating does not mean that every installation should operate continuously at 1600 A.

2. Short-Circuit Protection

A short circuit can produce a very high current within a short period. If not interrupted promptly, the resulting thermal and mechanical forces may damage electrical equipment and create serious safety risks.

The NS1600H H-class configuration is designed for high short-circuit interruption capability. Schneider Electric product information identifies a 70 kA ultimate breaking capacity at 415 V AC for relevant configurations.

The actual breaking capacity depends on the system voltage and exact breaker reference. Engineers must compare the prospective short-circuit current at the installation point with the breaker’s rated capacity.

3. Electronic Trip-Unit Operation

Certain NS1600H versions can be equipped with MicroLogic electronic trip units. Depending on the selected model, these units provide different combinations of protection and monitoring functions.

Examples include:

  • MicroLogic 2.0: Provides long-time and instantaneous protection functions in supported configurations.
  • MicroLogic 5.0: Provides long-time, short-time, and instantaneous protection functions.
  • MicroLogic 2.0A or 5.0A: Versions with additional measurement or display capabilities, depending on the specific product reference.

The exact protection functions and adjustment ranges must be confirmed from the installed trip-unit label and manufacturer’s documentation.

4. Switching and Isolation

The breaker can be used to connect or disconnect a distribution circuit during normal operation and maintenance. Supported configurations may use manual controls or an electrical operating mechanism.

The device’s suitability for isolation is subject to the relevant product configuration and applicable standards. Before maintenance, the circuit must be isolated using the approved site procedure and verified as de-energized.

5. Fault Indication and Monitoring

Depending on the trip unit and accessories, the breaker may provide local fault indications, measurement displays, auxiliary contacts, and remote status signals.

These features help electrical maintenance teams identify operating conditions and coordinate the breaker with supervisory systems. Not every NS1600H frame includes all these functions as standard equipment.

Role in Industrial Power Distribution Systems

The NS1600H can serve as a major protective switching device within an industrial low-voltage distribution network. Its role depends on its position in the electrical architecture and the protection functions selected for the installation.

Main Distribution Protection

In a main distribution board, a high-capacity circuit breaker can protect a major feeder or distribution section. It provides a means of interrupting the circuit when a fault or abnormal current condition occurs.

The breaker must be coordinated with upstream transformers, busbars, cables, and downstream protective devices. Its rating should be based on the actual electrical design rather than the frame current alone.

Transformer Secondary Protection

The NS1600H may be considered for appropriately rated transformer secondary distribution applications. In this role, the breaker helps protect the outgoing low-voltage network against overloads and short circuits.

Selection requires a detailed assessment of transformer capacity, secondary voltage, expected fault current, cable ratings, and protective-device coordination.

Generator and Power-System Distribution

Industrial facilities may use generators as standby or supplementary power sources. A suitable circuit breaker can form part of the generator distribution arrangement.

The protection settings must account for generator fault-current characteristics, system grounding, synchronization arrangements, and the requirements of the complete power system.

PLC and Automation Infrastructure

Industrial automation systems depend on stable electrical distribution for PLC cabinets, motor-control centers, instrumentation, and production equipment.

The NS1600H may protect a major distribution section supplying these systems. It does not replace the smaller branch-circuit protection devices required for individual control panels and field equipment.

Supervisory Monitoring

When equipped with compatible auxiliary contacts or electronic monitoring accessories, the breaker can provide status information to a plant monitoring or supervisory system.

The exact communication and monitoring capabilities depend on the installed trip unit and accessories. Confirm the required interface before planning integration with a PLC, SCADA, or building-management system.

Industrial Applications

The NS1600H is intended for high-capacity low-voltage distribution duties. Typical applications include:

1. Manufacturing Plants

Manufacturing facilities use large distribution boards to supply production lines, motor-control centers, compressors, pumps, and other electrical loads.

A correctly selected NS1600H configuration can provide circuit protection and switching for a major feeder or distribution section. Protection settings must be coordinated with the connected loads and downstream breakers.

2. Industrial Power Distribution Panels

Main distribution panels require circuit breakers with appropriate current ratings and short-circuit performance. The NS1600H may be used in systems where the calculated load and fault levels fall within its electrical capabilities.

Panel designers must also consider busbar ratings, cable connections, heat dissipation, mounting arrangements, and maintenance access.

3. Data Centers and Critical Facilities

Data centers and other critical facilities require carefully coordinated low-voltage distribution systems. Circuit breakers may protect incoming feeders, distribution sections, or selected power paths.

The NS1600H should only be applied where its interruption capacity, protection characteristics, and system configuration meet the facility’s electrical design requirements.

4. Infrastructure and Utility Facilities

Water treatment plants, transportation facilities, utility buildings, and other infrastructure installations often contain high-capacity electrical distribution systems.

A suitable NS1600H configuration can support feeder protection in these environments, provided that the device is selected for the actual voltage, fault level, environmental conditions, and operating requirements.

5. Commercial and Large Building Distribution

Large buildings may use high-capacity low-voltage switchboards to distribute power to HVAC equipment, elevators, pumps, lighting systems, and other major loads.

The NS1600H can be considered for appropriately rated distribution sections. Coordination with downstream protective devices is necessary to limit the extent of a fault-related interruption.

Installation and System Integration

Installing a 1600 A circuit breaker requires professional electrical engineering and qualified personnel. The installation must follow the manufacturer’s instructions, applicable electrical codes, and the approved system design.

1. Verify the Complete Product Reference

Before installation, check the complete catalog number and the nameplate. Confirm whether the unit is a basic frame or a complete circuit breaker with an installed trip unit.

Also verify:

  • Rated current and trip-unit rating.
  • Number of poles.
  • Fixed or withdrawable mounting arrangement.
  • Manual or electrical operation.
  • Short-circuit breaking capacity.
  • Installed protection functions.
  • Auxiliary contacts and other accessories.

These details are essential for determining whether the breaker is suitable for the intended application.

2. Confirm Electrical System Compatibility

Check the system’s rated voltage, frequency, available short-circuit current, grounding arrangement, and load characteristics.

The breaker’s ultimate and service breaking capacities must be suitable for the prospective fault current at the installation point. Protection settings must also be coordinated with the upstream and downstream devices.

3. Mechanical Mounting

The supplied dimensions are 327 × 210 × 147 mm. Verify these values against the manufacturer’s dimensional drawing for the exact pole count and mounting arrangement.

The switchboard must provide suitable structural support, electrical clearances, ventilation, and access for inspection and maintenance. Fixed and withdrawable configurations require different installation arrangements.

4. Electrical Connections

Power connections must be suitable for the rated current and the specified terminal arrangement. Busbars, conductors, connection hardware, and terminal tightening procedures must follow the manufacturer’s requirements.

Incorrect connections or insufficient tightening can lead to overheating, equipment damage, or unsafe operating conditions.

5. Protection Settings

Where an electronic trip unit is installed, protection parameters must be selected according to the system study and coordination requirements.

Important considerations include:

  • Long-time pickup and delay.
  • Short-time pickup and delay, where available.
  • Instantaneous pickup.
  • Ground-fault protection, if supported by the selected configuration.
  • Coordination with downstream circuit breakers.
  • Transformer, generator, and cable protection requirements.

Do not copy settings from another installation without verifying the electrical design.

6. Commissioning and Testing

Before energizing the breaker, qualified personnel should inspect mechanical mounting, electrical connections, protective settings, and accessory wiring.

The commissioning procedure should include appropriate functional checks and verification of protection settings. Testing must follow the manufacturer’s procedures and the site’s electrical safety requirements.

Compatible System Components

The NS1600H is normally installed as part of a complete low-voltage distribution assembly. The following components may be used in the surrounding electrical system, subject to engineering verification.

Component Function Integration Considerations
Main distribution busbar Distributes electrical power Verify current rating, short-circuit withstand, and connection compatibility
MicroLogic trip unit Provides electronic protection and monitoring Select the correct model and functions for the breaker
Auxiliary contacts Provide breaker status signals Confirm contact configuration and control-circuit ratings
Shunt trip release Enables remote electrical tripping Check accessory compatibility and control voltage
Undervoltage release Trips or prevents closing under specified voltage conditions Confirm the required release type and voltage
Motor mechanism Supports electrical operation Only applicable to compatible electrically operated versions
PLC Coordinates monitoring and control Use compatible auxiliary or communication interfaces
SCADA system Supervises power-system status Confirm the installed monitoring accessories and communication method
Low-voltage switchboard Houses and supports the breaker Verify mounting dimensions, clearances, and fault withstand ratings
Upstream transformer Supplies the distribution system Coordinate current rating and short-circuit protection

The listed components are examples of equipment that may be used in an engineered installation. They are not necessarily included with every NS1600H breaker.

Alternative Models and Replacement Considerations

When replacing an NS1600H, selection should be based on electrical performance and physical configuration rather than frame size alone.

Alternative or Related Product Replacement Considerations
Schneider ComPacT NS1600H with matching trip unit A like-for-like option may be possible if the complete reference and configuration match
Schneider ComPacT NS1250H Lower frame-current option; only suitable where the load and protection design permit
Schneider ComPacT NS1600N Different breaking-capacity class; verify fault-level requirements before considering
Schneider ComPacT NS1600L Higher breaking-capacity family option in applicable configurations; confirm physical and electrical compatibility
Schneider MasterPact air circuit breaker May be considered for a broader switchboard redesign or replacement project
Current-generation Schneider Electric circuit breaker May be suitable for an upgrade, but mounting, accessories, protection, and system coordination may need redesign

Before selecting a replacement, compare the following:

  • Rated operational voltage.
  • Rated current and trip-unit rating.
  • Ultimate and service short-circuit breaking capacities.
  • Number of poles and protected-pole arrangement.
  • Long-time, short-time, instantaneous, and ground-fault protection.
  • Fixed or withdrawable mounting.
  • Manual or electrical operation.
  • Auxiliary contacts and release accessories.
  • Physical dimensions and connection layout.
  • Switchboard compatibility and protection coordination.

A replacement breaker with the same 1600 A frame rating is not automatically interchangeable. Differences in mounting, trip-unit functions, and terminal arrangements can affect the entire distribution assembly.

Key Advantages

High Current Capacity

The NS1600H frame is designed for applications requiring a rated current of up to 1600 A, making it relevant to major industrial distribution circuits.

High Short-Circuit Breaking Capability

The H-class configuration provides a documented 70 kA ultimate breaking capacity at 415 V AC for relevant models, supporting use in systems with substantial prospective fault current.

Multiple Protection Configurations

The ComPacT NS family supports different electronic trip-unit options. The selected configuration determines the available overload, short-time, instantaneous, and monitoring functions.

Industrial Distribution Design

The breaker is designed for low-voltage power distribution and can be incorporated into appropriately engineered switchboards and electrical assemblies.

Flexible Installation Options

Depending on the selected product reference, fixed and withdrawable arrangements and different operating mechanisms are available.

Monitoring and Accessory Options

Compatible auxiliary contacts, releases, and electronic trip units can support local indication, remote signaling, and broader electrical-system monitoring.

Established Schneider Electric Product Family

The ComPacT NS range has been used in industrial and commercial electrical distribution installations. Accurate identification of the complete product reference remains essential when maintaining existing equipment.

Technical FAQs

1. What is the Schneider Electric NS1600H?

The NS1600H is a high-capacity low-voltage circuit breaker frame in the Schneider Electric ComPacT NS product family. It is associated with a 1600 A frame rating and H-class short-circuit breaking performance.

2. What is the rated current of the NS1600H?

The frame rating is 1600 A. The actual trip-unit rating and protection settings depend on the complete breaker configuration.

3. What is its breaking capacity at 415 V AC?

Relevant NS1600H H-class configurations have a 70 kA ultimate short-circuit breaking capacity at 415 V AC. Always verify the exact product reference and technical documentation.

4. Does every NS1600H include a MicroLogic trip unit?

No. Some product references identify a basic frame supplied without a trip unit, while complete breaker versions may include MicroLogic protection units. Check the catalog number and front-panel configuration.

5. What is the difference between Icu and Ics?

Icu is the rated ultimate short-circuit breaking capacity, while Ics is the rated service short-circuit breaking capacity. Both are important when evaluating a breaker for a particular electrical system.

6. Can the NS1600H be used in a 690 V AC system?

The product family includes configurations with a rated operational voltage up to 690 V AC. However, the available breaking capacity changes with operating voltage, so the exact model’s ratings must be checked.

7. Is the NS1600H suitable for a three-phase system?

Yes. Three-pole configurations are available for three-phase distribution systems. Four-pole versions are also available in the product family, depending on the complete reference.

8. Can it communicate with a PLC or SCADA system?

The breaker can provide status or monitoring information when equipped with compatible auxiliary contacts, electronic trip units, and communication accessories. The exact interface depends on the installed configuration.

9. What should be checked before replacing an existing NS1600H?

Verify the full catalog number, trip unit, rated current, breaking capacity, pole arrangement, mounting type, operating mechanism, accessories, and connection dimensions. Also confirm that the replacement meets the electrical protection study.

10. Why can NS1600H breakers have different weights and dimensions?

The product family includes different pole counts, fixed and withdrawable versions, basic frames, complete breakers, and different accessories. These variations affect the overall dimensions and weight. Use the exact product reference and manufacturer’s dimensional drawing for confirmation.

Procurement and Maintenance Recommendations

When purchasing a Schneider Electric NS1600H, the first step is to identify the complete product reference. The NS1600H designation alone does not confirm whether the unit includes a trip unit, which protection functions are available, or whether the breaker is fixed or withdrawable.

For replacement projects, request clear photographs of the front panel, nameplate, terminal arrangement, and installed trip unit. Confirm the rated current, pole count, voltage rating, breaking capacity, and accessory configuration.

For used or refurbished equipment, inspect the enclosure, operating mechanism, terminals, contact condition, trip unit, and accessory wiring. Where appropriate, request documented inspection or functional test information from a qualified service provider.

During routine maintenance, follow the manufacturer’s inspection and testing procedures. Check mechanical operation, connection condition, signs of overheating, trip-unit settings, and the condition of the switchboard environment. Any adjustment to protection settings should be performed by qualified personnel and recorded in the electrical maintenance documentation.

For critical distribution systems, breaker replacement should be treated as an engineering task. Confirm the prospective fault current, selectivity, protection coordination, and switchboard compatibility before energizing the replacement device.

Conclusion

The Schneider Electric NS1600H ComPacT Circuit Breaker is a high-capacity low-voltage protection device associated with a 1600 A frame rating and H-class short-circuit performance. Relevant configurations provide a 70 kA ultimate breaking capacity at 415 V AC and support industrial power distribution applications.

The complete breaker configuration determines its trip unit, protection functions, pole arrangement, operating mechanism, and mounting style. For maintenance and procurement, checking the full catalog number is essential to ensure that the selected NS1600H matches the electrical and mechanical requirements of the installation.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501