The Schneider MT40H2 MasterPact Circuit Breaker Frame is a high-current air circuit breaker frame associated with the MasterPact NW40H2 configuration. It is used in low-voltage power distribution systems where high current-carrying capacity and substantial short-circuit interruption performance are required.
The NW40H2 configuration has a rated current of 4000 A and belongs to the H2 breaking performance category. It provides a rated ultimate short-circuit breaking capacity of 100 kA at 440 V AC, making it suitable for main power distribution and high-capacity feeder protection in industrial switchgear installations.
The MasterPact NW platform is used in large electrical distribution systems, including manufacturing plants, commercial infrastructure, and industrial power distribution facilities. Its three-pole fixed configuration supports installation in compatible low-voltage switchgear assemblies.
The MT40H2 frame can be integrated with compatible MasterPact electronic protection units and operating accessories. These components provide the protection, monitoring, and switching functions required by the electrical distribution system.
For replacement applications, engineers should verify the complete NW40H2 configuration, including rated current, breaking capacity, pole arrangement, mounting type, protection unit, and electrical connection requirements.
| Parameter | Specification |
|---|---|
| Manufacturer | Schneider Electric |
| Model | MT40H2 |
| Product Type | MasterPact Circuit Breaker Frame |
| Product Series | MasterPact NW |
| Circuit Breaker Configuration | NW40H2 |
| Circuit Breaker Type | Air Circuit Breaker |
| Rated Current | 4000 A |
| Number of Poles | 3P |
| Breaking Capacity | 100 kA at 440 V AC |
| Breaking Capacity at 525 V AC | 85 kA |
| Breaking Capacity at 690 V AC | 85 kA |
| Rated Operational Voltage | 690 V AC |
| Frequency | 50/60 Hz |
| Performance Level | H2 |
| Mounting Type | Fixed |
| Control Unit | Without Control Unit |
| Suitability for Isolation | Yes |
| Utilization Category | Category B |
| Insulation Voltage | 1000 V AC |
| Impulse Withstand Voltage | 12 kV |
| Short-Time Withstand Current | 85 kA for 1 s |
| Maximum Breaking Time | 25 ms |
| Maximum Closing Response Time | 70 ms |
| Dimensions | 422 × 300 × 352 mm |
| Weight | 50 kg |
The MasterPact NW40H2 operates as an air circuit breaker that controls the electrical connection between the incoming power supply and the downstream distribution system.
During normal operation, current flows through the main contacts of the breaker to supply connected electrical equipment. The circuit breaker remains closed while the electrical conditions stay within the permitted operating limits.
When an overload or short circuit occurs, the associated electronic protection unit detects the abnormal current condition and initiates the tripping mechanism. The main contacts separate, interrupting the electrical circuit.
As the contacts open, an electrical arc forms between them. The air arc-extinguishing system controls and extinguishes the arc, allowing the breaker to interrupt the fault current within its specified breaking capacity.
The H2 performance configuration provides a rated ultimate short-circuit breaking capacity of 100 kA at 440 V AC. At higher operating voltages of 525 V and 690 V AC, the specified breaking capacity is 85 kA.
Typical Protection Sequence:
Incoming Power Supply → MasterPact NW40H2 Circuit Breaker → Main Distribution Busbar → Downstream Feeder Circuits
After a fault interruption, the cause of the trip should be investigated before the circuit breaker is reset and returned to service.
The MT40H2 serves as a main or feeder circuit protection component within compatible MasterPact NW40H2 low-voltage distribution systems.
In a typical industrial switchgear arrangement, the breaker is installed between the incoming electrical supply and the main distribution busbar. It provides switching and fault interruption functions for high-current electrical circuits.
Its 4000 A rated current and H2 breaking performance make it suitable for installations where substantial electrical loads and high prospective short-circuit currents must be managed.
| System Component | Function |
|---|---|
| MT40H2 MasterPact Circuit Breaker | Provides high-current switching and circuit protection |
| Incoming Power Supply | Delivers electrical power to the switchgear |
| Main Distribution Busbar | Distributes power to downstream electrical circuits |
| Micrologic Protection Unit | Provides electronic overload and short-circuit protection |
| Operating Mechanism | Controls circuit breaker opening and closing |
| Auxiliary Contacts | Provide breaker operating status signals |
| Shunt Trip Release | Enables remote electrical tripping |
| Undervoltage Release | Initiates opening under specified undervoltage conditions |
| Switchgear Enclosure | Houses and protects the circuit breaker assembly |
| Downstream Circuit Breakers | Protect individual outgoing distribution circuits |
| Application | Typical Use |
|---|---|
| Industrial Power Distribution | Main circuit protection in high-current distribution systems |
| Manufacturing Plants | Protecting electrical supplies for production facilities |
| Commercial Buildings | High-capacity low-voltage electrical distribution |
| Data Centers | Protecting large electrical distribution circuits |
| Power Distribution Rooms | Incoming and feeder circuit protection |
| Process Industries | Protecting electrical supplies for continuous production |
| Infrastructure Projects | Integrating high-capacity switchgear |
| Utility Installations | Main electrical distribution protection |
| Industrial Switchboards | Protecting main distribution busbars |
| Electrical Substations | Low-voltage feeder and distribution protection |
| Component | Product Description | Function |
|---|---|---|
| Micrologic 5.0 | MasterPact Electronic Trip Unit | Provides electronic protection functions |
| Micrologic 6.0 | MasterPact Electronic Trip Unit | Supports advanced circuit protection |
| MCH | MasterPact Charging Motor | Charges the stored-energy operating mechanism |
| MX | MasterPact Shunt Trip Release | Enables remote circuit breaker tripping |
| MN | MasterPact Undervoltage Release | Initiates opening under undervoltage conditions |
| OF Auxiliary Contact | MasterPact Auxiliary Switch | Indicates breaker open or closed status |
| Model | Product Description |
|---|---|
| NW32H2 | Schneider MasterPact NW 3200 A H2 Air Circuit Breaker |
| NW40H1 | Schneider MasterPact NW 4000 A H1 Air Circuit Breaker |
| NW40H2 | Schneider MasterPact NW 4000 A H2 Air Circuit Breaker |
| NW40H3 | Schneider MasterPact NW 4000 A H3 Air Circuit Breaker |
| NW40H10 | Schneider MasterPact NW 4000 A H10 Air Circuit Breaker |
| NW40HA | Schneider MasterPact NW 4000 A HA Air Circuit Breaker |
The associated MasterPact NW40H2 configuration has a rated current of 4000 A at 40 °C. This distinguishes it from the NW32H2 configuration, which has a rated current of 3200 A.
The H2 configuration provides a rated ultimate short-circuit breaking capacity of 100 kA at 440 V AC. The corresponding breaking capacity is 85 kA at 525 V and 690 V AC.
The specified configuration is supplied without a control unit. A compatible Micrologic protection unit must be selected according to the required overload, short-circuit, and other protection functions.
Verify the 4000 A rated current, H2 breaking performance, three-pole configuration, fixed mounting arrangement, and control unit requirements. The switchgear connection arrangement and installed accessories should also be checked before replacement.