Product Overview The Schneider MT40H2 MasterPact Circuit Breaker Frame is a high-current air circuit breaker frame associated with the MasterPact NW40H2 configuration. It is used in low-voltage power di……
Schneider MT40H2 MasterPact Circuit Breaker Frame
  • Schneider
  • MT40H2
  • MasterPact Circuit Breaker Frame
  • France
  • 422 × 300 × 352 mm
  • 50 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 6

Our advantage

Schneider MT40H2 MasterPact Circuit Breaker Frame

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Schneider MT40H2 MasterPact Circuit Breaker Frame

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Schneider MT40H2 MasterPact Circuit Breaker Frame

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Schneider MT40H2 MasterPact Circuit Breaker Frame

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Schneider MT40H2 MasterPact Circuit Breaker Frame is a high-current air circuit breaker frame associated with the MasterPact NW40H2 configuration. It is used in low-voltage power distribution systems where high current-carrying capacity and substantial short-circuit interruption performance are required.

The NW40H2 configuration has a rated current of 4000 A and belongs to the H2 breaking performance category. It provides a rated ultimate short-circuit breaking capacity of 100 kA at 440 V AC, making it suitable for main power distribution and high-capacity feeder protection in industrial switchgear installations.

The MasterPact NW platform is used in large electrical distribution systems, including manufacturing plants, commercial infrastructure, and industrial power distribution facilities. Its three-pole fixed configuration supports installation in compatible low-voltage switchgear assemblies.

The MT40H2 frame can be integrated with compatible MasterPact electronic protection units and operating accessories. These components provide the protection, monitoring, and switching functions required by the electrical distribution system.

For replacement applications, engineers should verify the complete NW40H2 configuration, including rated current, breaking capacity, pole arrangement, mounting type, protection unit, and electrical connection requirements.


Technical Specifications

Parameter Specification
Manufacturer Schneider Electric
Model MT40H2
Product Type MasterPact Circuit Breaker Frame
Product Series MasterPact NW
Circuit Breaker Configuration NW40H2
Circuit Breaker Type Air Circuit Breaker
Rated Current 4000 A
Number of Poles 3P
Breaking Capacity 100 kA at 440 V AC
Breaking Capacity at 525 V AC 85 kA
Breaking Capacity at 690 V AC 85 kA
Rated Operational Voltage 690 V AC
Frequency 50/60 Hz
Performance Level H2
Mounting Type Fixed
Control Unit Without Control Unit
Suitability for Isolation Yes
Utilization Category Category B
Insulation Voltage 1000 V AC
Impulse Withstand Voltage 12 kV
Short-Time Withstand Current 85 kA for 1 s
Maximum Breaking Time 25 ms
Maximum Closing Response Time 70 ms
Dimensions 422 × 300 × 352 mm
Weight 50 kg

Product Features

  • 4000 A Current Rating: Supports high-capacity electrical distribution in industrial and commercial power systems.
  • H2 Breaking Performance: Provides a rated ultimate short-circuit breaking capacity of 100 kA at 440 V AC.
  • Three-Pole Configuration: Supports three-phase electrical distribution and circuit protection.
  • MasterPact NW Platform: Belongs to Schneider Electric’s high-current air circuit breaker product family.
  • Fixed Mounting Arrangement: Supports direct installation in compatible low-voltage switchgear assemblies.
  • High Short-Time Withstand Capacity: Supports 85 kA short-time withstand current for 1 second.
  • Isolation Capability: Suitable for electrical isolation according to EN/IEC 60947-2.
  • Protection Unit Compatibility: Supports compatible MasterPact electronic trip units according to the selected configuration.

Working Principle

The MasterPact NW40H2 operates as an air circuit breaker that controls the electrical connection between the incoming power supply and the downstream distribution system.

During normal operation, current flows through the main contacts of the breaker to supply connected electrical equipment. The circuit breaker remains closed while the electrical conditions stay within the permitted operating limits.

When an overload or short circuit occurs, the associated electronic protection unit detects the abnormal current condition and initiates the tripping mechanism. The main contacts separate, interrupting the electrical circuit.

As the contacts open, an electrical arc forms between them. The air arc-extinguishing system controls and extinguishes the arc, allowing the breaker to interrupt the fault current within its specified breaking capacity.

The H2 performance configuration provides a rated ultimate short-circuit breaking capacity of 100 kA at 440 V AC. At higher operating voltages of 525 V and 690 V AC, the specified breaking capacity is 85 kA.

Typical Protection Sequence:

Incoming Power Supply → MasterPact NW40H2 Circuit Breaker → Main Distribution Busbar → Downstream Feeder Circuits

After a fault interruption, the cause of the trip should be investigated before the circuit breaker is reset and returned to service.


Role in Schneider MasterPact Power Distribution Architecture

The MT40H2 serves as a main or feeder circuit protection component within compatible MasterPact NW40H2 low-voltage distribution systems.

In a typical industrial switchgear arrangement, the breaker is installed between the incoming electrical supply and the main distribution busbar. It provides switching and fault interruption functions for high-current electrical circuits.

Its 4000 A rated current and H2 breaking performance make it suitable for installations where substantial electrical loads and high prospective short-circuit currents must be managed.

System Component Function
MT40H2 MasterPact Circuit Breaker Provides high-current switching and circuit protection
Incoming Power Supply Delivers electrical power to the switchgear
Main Distribution Busbar Distributes power to downstream electrical circuits
Micrologic Protection Unit Provides electronic overload and short-circuit protection
Operating Mechanism Controls circuit breaker opening and closing
Auxiliary Contacts Provide breaker operating status signals
Shunt Trip Release Enables remote electrical tripping
Undervoltage Release Initiates opening under specified undervoltage conditions
Switchgear Enclosure Houses and protects the circuit breaker assembly
Downstream Circuit Breakers Protect individual outgoing distribution circuits

Industrial Applications

Application Typical Use
Industrial Power Distribution Main circuit protection in high-current distribution systems
Manufacturing Plants Protecting electrical supplies for production facilities
Commercial Buildings High-capacity low-voltage electrical distribution
Data Centers Protecting large electrical distribution circuits
Power Distribution Rooms Incoming and feeder circuit protection
Process Industries Protecting electrical supplies for continuous production
Infrastructure Projects Integrating high-capacity switchgear
Utility Installations Main electrical distribution protection
Industrial Switchboards Protecting main distribution busbars
Electrical Substations Low-voltage feeder and distribution protection

Installation and Maintenance

  1. Verify Model Configuration: Confirm that MT40H2 corresponds to the required MasterPact NW40H2 configuration, including rated current, breaking capacity, and pole arrangement.
  2. Check Switchgear Compatibility: Verify the fixed mounting arrangement and electrical connection requirements against the existing switchgear assembly.
  3. Isolate the Power Supply: Disconnect the upstream power source and apply the required lockout and tagout procedures.
  4. Verify Absence of Voltage: Use an appropriately rated voltage tester to confirm that all relevant electrical connections are de-energized.
  5. Inspect Main Connections: Examine incoming and outgoing connection points for overheating, oxidation, corrosion, or mechanical damage.
  6. Check Protection Configuration: Verify the installed protection unit and its settings against the electrical coordination requirements.
  7. Inspect Operating Mechanism: Check the opening, closing, and stored-energy operating functions according to the applicable maintenance instructions.
  8. Check Auxiliary Accessories: Inspect auxiliary contacts, shunt releases, undervoltage releases, and other installed accessories.
  9. Verify Mounting Security: Confirm that the circuit breaker is correctly positioned and secured within the switchgear assembly.
  10. Perform Electrical Testing: Carry out the required insulation, contact resistance, and protection function tests using approved procedures.
  11. Conduct Operational Checks: Verify mechanical and electrical operating functions before returning the equipment to service.
  12. Document Maintenance Results: Record the breaker configuration, protection settings, inspection findings, test results, and maintenance date.

Compatible System Components

Component Product Description Function
Micrologic 5.0 MasterPact Electronic Trip Unit Provides electronic protection functions
Micrologic 6.0 MasterPact Electronic Trip Unit Supports advanced circuit protection
MCH MasterPact Charging Motor Charges the stored-energy operating mechanism
MX MasterPact Shunt Trip Release Enables remote circuit breaker tripping
MN MasterPact Undervoltage Release Initiates opening under undervoltage conditions
OF Auxiliary Contact MasterPact Auxiliary Switch Indicates breaker open or closed status

Recommended Related Models

Model Product Description
NW32H2 Schneider MasterPact NW 3200 A H2 Air Circuit Breaker
NW40H1 Schneider MasterPact NW 4000 A H1 Air Circuit Breaker
NW40H2 Schneider MasterPact NW 4000 A H2 Air Circuit Breaker
NW40H3 Schneider MasterPact NW 4000 A H3 Air Circuit Breaker
NW40H10 Schneider MasterPact NW 4000 A H10 Air Circuit Breaker
NW40HA Schneider MasterPact NW 4000 A HA Air Circuit Breaker

Key Advantages

  • 4000 A rated current for high-capacity electrical distribution.
  • H2 performance with 100 kA breaking capacity at 440 V AC.
  • Three-pole configuration for three-phase power systems.
  • Fixed mounting arrangement for compatible switchgear installations.
  • Supports overload and short-circuit protection.
  • Compatible with the MasterPact NW protection and accessory ecosystem.
  • Suitable for industrial and commercial low-voltage distribution applications.

Technical FAQs

1. What is the rated current of the MT40H2?

The associated MasterPact NW40H2 configuration has a rated current of 4000 A at 40 °C. This distinguishes it from the NW32H2 configuration, which has a rated current of 3200 A.

2. What is the short-circuit breaking capacity of the NW40H2?

The H2 configuration provides a rated ultimate short-circuit breaking capacity of 100 kA at 440 V AC. The corresponding breaking capacity is 85 kA at 525 V and 690 V AC.

3. Does the MT40H2 include an electronic protection unit?

The specified configuration is supplied without a control unit. A compatible Micrologic protection unit must be selected according to the required overload, short-circuit, and other protection functions.

4. What should be checked when replacing an MT40H2 circuit breaker?

Verify the 4000 A rated current, H2 breaking performance, three-pole configuration, fixed mounting arrangement, and control unit requirements. The switchgear connection arrangement and installed accessories should also be checked before replacement.