The Schneider MT25H2 MasterPact Circuit Breaker Frame is a high-current air circuit breaker assembly used in low-voltage power distribution systems. It belongs to the MasterPact NW25H2 product configuration, which is rated for 2500 A and provides high short-circuit interruption performance for industrial and commercial electrical installations.
The MT25H2 configuration is associated with the MasterPact NW circuit breaker platform. Its primary function is to provide circuit protection by interrupting electrical current when overloads or short circuits occur. The H2 performance level provides a rated ultimate short-circuit breaking capacity of 100 kA at 440 V AC.
The MasterPact circuit breaker is suitable for applications involving large distribution boards, industrial switchgear, and main power supply systems. It supports fixed mounting arrangements and three-pole electrical distribution configurations.
The circuit breaker can be integrated into low-voltage switchboards where high current-carrying capacity and coordinated circuit protection are required. Its protection arrangement can be combined with compatible control and protection accessories according to the selected equipment configuration.
For replacement and equipment maintenance, the complete MasterPact NW25H2 configuration should be checked against the existing switchgear arrangement, including rated current, breaking capacity, pole configuration, mounting type, and control unit requirements.
| Parameter | Specification |
|---|---|
| Manufacturer | Schneider Electric |
| Model | MT25H2 |
| Product Type | MasterPact Circuit Breaker Frame |
| Product Series | MasterPact NW |
| Circuit Breaker Configuration | NW25H2 |
| Circuit Breaker Type | Air Circuit Breaker |
| Rated Current | 2500 A |
| Number of Poles | 3P |
| Breaking Capacity | 100 kA at 440 V AC |
| Rated Operational Voltage | 690 V AC |
| Frequency | 50/60 Hz |
| Performance Level | H2 |
| Mounting Type | Fixed |
| Control Unit | Without Control Unit |
| Suitability for Isolation | Yes |
| Utilization Category | Category B |
| Insulation Voltage | 1000 V AC |
| Impulse Withstand Voltage | 12 kV |
| Maximum Breaking Time | 25 ms |
| Maximum Closing Response Time | 70 ms |
| Dimensions | 422 × 300 × 352 mm |
| Weight | 50 kg |
The MasterPact NW25H2 operates as an air circuit breaker that monitors the electrical current flowing through the protected circuit.
During normal operation, current passes through the main contacts of the breaker to supply downstream electrical equipment. The circuit breaker remains closed while operating conditions stay within the permitted protection limits.
When an overload or short circuit occurs, the associated protection system detects the abnormal current condition and initiates the opening mechanism. The main contacts separate, interrupting the electrical circuit.
During contact separation, an electrical arc forms between the contacts. The air arc-extinguishing arrangement controls and extinguishes this arc, allowing the circuit to be interrupted safely within the specified breaking capacity.
The H2 performance configuration provides a 100 kA ultimate short-circuit breaking capacity at 440 V AC. This capability makes the breaker suitable for distribution installations where high prospective fault currents must be interrupted.
Typical Protection Sequence:
Incoming Power Supply → MasterPact NW25H2 Circuit Breaker → Protected Distribution Busbar → Downstream Electrical Loads
After a fault interruption, the cause of the trip should be investigated before the breaker is returned to service. Resetting the mechanism without identifying the fault may expose the electrical installation to repeated short-circuit or overload conditions.
The MT25H2 serves as a main or distribution-level circuit protection device within compatible MasterPact NW switchgear arrangements.
In a typical low-voltage distribution system, the breaker is installed between the incoming power supply and the downstream distribution busbar. It provides the switching and interruption capability required to isolate electrical circuits during abnormal operating conditions.
Its 2500 A current rating and H2 interruption performance make it suitable for large industrial distribution installations.
| System Component | Function |
|---|---|
| MT25H2 MasterPact Circuit Breaker | Provides main circuit switching and protection |
| Incoming Power Supply | Delivers electrical power to the distribution system |
| Distribution Busbar | Distributes electrical power to downstream circuits |
| Micrologic Protection Unit | Provides compatible electronic protection functions |
| Circuit Breaker Operating Mechanism | Controls opening and closing operations |
| Auxiliary Contacts | Provide breaker status information |
| Undervoltage Release | Initiates opening under specified voltage conditions |
| Shunt Trip Release | Allows remote electrical tripping |
| Switchgear Enclosure | Houses and protects the circuit breaker assembly |
| Downstream Circuit Breakers | Protect individual outgoing distribution circuits |
| Application | Typical Use |
|---|---|
| Industrial Power Distribution | Main circuit protection in high-current distribution systems |
| Manufacturing Plants | Protecting electrical supply circuits for production facilities |
| Commercial Buildings | Main low-voltage electrical distribution |
| Data Centers | Protecting high-capacity electrical distribution systems |
| Power Distribution Rooms | Incoming and outgoing feeder protection |
| Process Industries | Protecting electrical supply systems for continuous production |
| Infrastructure Projects | High-current switchgear installations |
| Utility Distribution | Main circuit switching and protection |
| Industrial Switchboards | Integrating circuit protection into distribution assemblies |
| Electrical Substations | Low-voltage distribution and feeder protection |
| Component | Product Description | Function |
|---|---|---|
| Micrologic 5.0 | MasterPact Electronic Trip Unit | Provides electronic protection functions |
| Micrologic 6.0 | MasterPact Electronic Trip Unit | Supports advanced circuit protection |
| MCH | MasterPact Charging Motor | Charges the stored-energy operating mechanism |
| MX | MasterPact Shunt Trip Release | Enables remote circuit breaker tripping |
| MN | MasterPact Undervoltage Release | Initiates opening under undervoltage conditions |
| OF Auxiliary Contact | MasterPact Auxiliary Switch | Indicates breaker open or closed status |
| Model | Product Description |
|---|---|
| NW20H2 | Schneider MasterPact NW 2000 A H2 Air Circuit Breaker |
| NW25H1 | Schneider MasterPact NW 2500 A H1 Air Circuit Breaker |
| NW25H2 | Schneider MasterPact NW 2500 A H2 Air Circuit Breaker |
| NW25H3 | Schneider MasterPact NW 2500 A H3 Air Circuit Breaker |
| NW25H10 | Schneider MasterPact NW 2500 A H10 Air Circuit Breaker |
| NW25HA | Schneider MasterPact NW 2500 A HA Air Circuit Breaker |
H2 identifies the circuit breaker’s performance level. For the NW25H2 configuration, it corresponds to a rated ultimate short-circuit breaking capacity of 100 kA at 440 V AC.
The MasterPact NW25H2 configuration has a rated current of 2500 A at 40 °C. The actual operating conditions and switchgear installation must comply with the applicable equipment specifications.
The specified configuration is supplied without a control unit. A compatible protection unit must be selected according to the required protection functions and circuit breaker configuration.
Verify the MasterPact NW platform, 2500 A current rating, H2 breaking performance, three-pole configuration, fixed mounting arrangement, and control unit requirements. The existing switchgear connections and accessory configuration should also be checked before replacement.