The Schneider MT32H2 MasterPact Circuit Breaker Frame is a high-current air circuit breaker frame associated with the MasterPact NW32H2 configuration. It is used in low-voltage power distribution systems requiring high current-carrying capacity and short-circuit protection.
The NW32H2 configuration has a rated current of 3200 A and belongs to the H2 breaking performance category. It provides a rated ultimate short-circuit breaking capacity of 100 kA at 440 V AC, making it suitable for main distribution and high-capacity feeder protection in industrial switchgear installations.
The MasterPact NW platform supports three-phase electrical distribution and can be integrated into compatible low-voltage switchboards. The fixed mounting configuration provides a direct installation arrangement within the corresponding switchgear assembly.
The MT32H2 frame is associated with applications where electrical loads require substantial current capacity and coordinated circuit protection. It can be used with compatible MasterPact protection units and operating accessories according to the selected equipment configuration.
When selecting a replacement, engineers should verify the complete NW32H2 configuration, including rated current, breaking capacity, pole arrangement, mounting type, control unit, and electrical connection requirements.
| Parameter | Specification |
|---|---|
| Manufacturer | Schneider Electric |
| Model | MT32H2 |
| Product Type | MasterPact Circuit Breaker Frame |
| Product Series | MasterPact NW |
| Associated Configuration | NW32H2 |
| Circuit Breaker Type | Air Circuit Breaker |
| Rated Current | 3200 A |
| Number of Poles | 3P |
| Performance Level | H2 |
| Ultimate Breaking Capacity | 100 kA at 440 V AC |
| Rated Operational Voltage | 690 V AC |
| Frequency | 50/60 Hz |
| Rated Insulation Voltage | 1000 V AC |
| Impulse Withstand Voltage | 12 kV |
| Short-Time Withstand Current | 85 kA for 1 s |
| Mounting Type | Fixed |
| Control Unit | Without Control Unit |
| Suitability for Isolation | Yes |
| Utilization Category | Category B |
| Dimensions | 422 × 300 × 352 mm |
| Weight | 50 kg |
The MT32H2 operates as part of the MasterPact NW32H2 air circuit breaker system. It controls the electrical connection between the incoming power supply and the downstream distribution circuit.
During normal operation, current flows through the main contacts of the circuit breaker to supply connected electrical equipment. The breaker remains closed while the electrical conditions stay within the permitted operating limits.
When an overload or short circuit occurs, the associated protection unit detects the abnormal current condition and initiates the tripping mechanism. The main contacts separate, interrupting the electrical circuit.
As the contacts open, an electrical arc forms between them. The air arc-extinguishing system controls and extinguishes the arc, allowing the circuit breaker to interrupt the fault current.
The NW32H2 configuration provides a rated ultimate short-circuit breaking capacity of 100 kA at 440 V AC. This capability is particularly relevant to installations where the prospective fault current is high.
Typical Protection Sequence:
Incoming Power Supply → MT32H2 MasterPact Circuit Breaker → Main Distribution Busbar → Downstream Feeder Circuits
After a fault interruption, the cause of the trip should be investigated before the breaker is reset and returned to service.
The MT32H2 serves as a main or feeder circuit protection component in compatible MasterPact NW32H2 low-voltage distribution systems.
In a typical switchgear installation, the circuit breaker is positioned between the incoming electrical supply and the downstream distribution busbar. It provides switching and fault interruption functions for high-current electrical circuits.
Its 3200 A rating and H2 interruption performance make it suitable for distribution systems with substantial electrical loads and high prospective short-circuit currents.
| System Component | Function |
|---|---|
| MT32H2 MasterPact Circuit Breaker | Provides high-current switching and circuit protection |
| Incoming Power Supply | Delivers electrical power to the switchgear |
| Main Distribution Busbar | Distributes power to downstream circuits |
| Micrologic Protection Unit | Provides electronic protection functions |
| Operating Mechanism | Controls circuit breaker opening and closing |
| Auxiliary Contacts | Provide breaker operating status signals |
| Shunt Trip Release | Enables remote electrical tripping |
| Undervoltage Release | Initiates opening under specified undervoltage conditions |
| Switchgear Enclosure | Houses and protects the circuit breaker assembly |
| Downstream Circuit Breakers | Protect individual outgoing circuits |
| Application | Typical Use |
|---|---|
| Industrial Power Distribution | Main circuit protection in high-current distribution systems |
| Manufacturing Plants | Protecting production facility electrical supplies |
| Commercial Buildings | High-capacity low-voltage power distribution |
| Data Centers | Protecting large electrical distribution circuits |
| Power Distribution Rooms | Incoming and feeder circuit protection |
| Process Industries | Protecting electrical supplies for continuous production |
| Infrastructure Projects | Integrating high-capacity switchgear |
| Utility Installations | Main electrical distribution protection |
| Industrial Switchboards | Protecting main distribution busbars |
| Electrical Substations | Low-voltage feeder and distribution protection |
| Component | Product Description | Function |
|---|---|---|
| Micrologic 5.0 | MasterPact Electronic Trip Unit | Provides electronic protection functions |
| Micrologic 6.0 | MasterPact Electronic Trip Unit | Supports advanced circuit protection |
| MCH | MasterPact Charging Motor | Charges the stored-energy operating mechanism |
| MX | MasterPact Shunt Trip Release | Enables remote circuit breaker tripping |
| MN | MasterPact Undervoltage Release | Initiates opening under undervoltage conditions |
| OF Auxiliary Contact | MasterPact Auxiliary Switch | Indicates breaker open or closed status |
| Model | Product Description |
|---|---|
| NW25H2 | Schneider MasterPact NW 2500 A H2 Air Circuit Breaker |
| NW32H1 | Schneider MasterPact NW 3200 A H1 Air Circuit Breaker |
| NW32H2 | Schneider MasterPact NW 3200 A H2 Air Circuit Breaker |
| NW32H3 | Schneider MasterPact NW 3200 A H3 Air Circuit Breaker |
| NW32HA | Schneider MasterPact NW 3200 A HA Air Circuit Breaker |
| NW32H10 | Schneider MasterPact NW 3200 A H10 Air Circuit Breaker |
The associated MasterPact NW32H2 configuration has a rated current of 3200 A at 40 °C. This rating distinguishes it from the NW25H2 configuration, which is rated at 2500 A.
H2 identifies the circuit breaker’s short-circuit breaking performance. The NW32H2 provides a rated ultimate short-circuit breaking capacity of 100 kA at 440 V AC and 85 kA at 690 V AC.
The specified configuration is without a control unit. A compatible protection unit must be selected according to the required overload, short-circuit, and other protection functions of the electrical installation.
The fixed configuration is installed directly into the switchgear assembly, whereas the drawout configuration uses a withdrawable mounting arrangement that allows the breaker to be moved between connected, test, and disconnected positions. The mounting configuration must match the existing switchgear design.