Product Overview The Schneider Electric MT16N1 Circuit Breaker is associated with the Masterpact MT air circuit breaker family, which is designed for low-voltage power distribution and protection in ind……
Schneider MT16N1 Circuit Breaker
  • Schneider
  • MT16N1
  • Circuit Breaker
  • France
  • 301 x 276 x 196 mm
  • 14 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 3

Our advantage

Schneider MT16N1 Circuit Breaker

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Schneider MT16N1 Circuit Breaker

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Schneider MT16N1 Circuit Breaker

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Schneider MT16N1 Circuit Breaker

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Schneider Electric MT16N1 Circuit Breaker is associated with the Masterpact MT air circuit breaker family, which is designed for low-voltage power distribution and protection in industrial and commercial electrical systems. The MT16N1 designation is commonly associated with a 1600 A frame rating and an N1 breaking-capacity classification. The complete product configuration must be verified before the device is selected for a specific installation.

Air circuit breakers are used in main distribution boards, switchgear assemblies, and industrial power systems where large electrical loads require reliable switching and overcurrent protection. Compared with miniature and molded-case circuit breakers, air circuit breakers are intended for higher-current distribution applications and can offer configurable protection and control functions according to the selected model.

Schneider Electric’s Masterpact family includes circuit breakers designed to protect electrical installations against overloads and short circuits. Depending on the exact version, additional functions may include adjustable electronic protection, auxiliary status contacts, remote operation, and integration with electrical monitoring systems.

The MT16N1 designation alone does not establish every feature of an individual breaker. Pole count, mounting arrangement, trip unit, rated operating voltage, and short-circuit performance must be confirmed from the product nameplate and complete ordering reference. These details are especially important when replacing an existing breaker or integrating it into an established switchgear assembly.

For industrial buyers, maintenance teams, and electrical panel builders, correct identification is essential. A circuit breaker with a similar current rating may have different dimensions, terminal arrangements, protection settings, and compatibility requirements. Verification before procurement helps reduce installation risks and avoid costly modifications.

Technical Specifications

Parameter Specification
Brand Schneider Electric
Product Designation MT16N1
Product Family Masterpact MT
Product Type Air Circuit Breaker (ACB)
Application Low-voltage power distribution and circuit protection
Associated Frame Rating 1600 A
Breaking-Capacity Classification N1; confirm the applicable standard and rated voltage
Operating Network AC, depending on the exact configuration
Number of Poles Must be verified from the complete catalog number
Trip Unit Must be verified from the installed configuration
Mounting Type Fixed or drawout; verify the actual unit
Dimensions Provided 301 × 276 × 196 mm
Weight Provided 14 kg
Installation Location Electrical distribution panel or switchgear assembly
Product Identification Verify the complete catalog number and nameplate

Important: MT16N1 is not sufficient to determine all electrical ratings or accessories. The dimensions and weight above are the supplied listing values and should be checked against the exact unit before publication, installation planning, or shipment.

Function and Working Principle

The primary function of an air circuit breaker is to establish, carry, and interrupt electrical current under specified operating conditions. It also provides protection against defined abnormal current conditions when equipped with a suitable protection unit.

1. Normal Current Switching

During normal operation, the circuit breaker’s main contacts carry current from the incoming supply to the downstream distribution system. The contacts and conductive components must be suitable for the circuit’s rated current and operating environment.

When switching is required, the breaker opens or closes its main contacts through its operating mechanism. The exact operating method depends on the breaker configuration and whether manual, motorized, or other control accessories are installed.

2. Overload Protection

An overload occurs when a circuit carries more current than intended for a sustained period. If the breaker is equipped with a compatible protection unit, it can evaluate the current against the configured protection characteristics and initiate a trip when the defined conditions are met.

Proper overload protection helps protect conductors and electrical equipment from excessive heating. The settings must be coordinated with cable ratings, downstream protective devices, load characteristics, and applicable electrical standards.

3. Short-Circuit Protection

A short circuit can produce a very high fault current. The breaker must be suitable for the prospective fault current at its installation point and must be equipped with an appropriate protection configuration.

When a fault meets the configured trip criteria, the protection mechanism initiates opening of the contacts. The breaker must be rated to interrupt the applicable fault current safely under its specified voltage and operating conditions.

The N1 designation should not be treated as a universal short-circuit rating independent of voltage and standard. Confirm the relevant breaking-capacity value from the exact product documentation.

4. Arc Interruption

When a circuit breaker opens while current is flowing, an electrical arc can form between the separating contacts. Air circuit breakers use an arc-control and interruption arrangement designed to extinguish this arc within the device’s rated operating conditions.

The interruption capability depends on the breaker design, contact system, operating mechanism, and specified electrical ratings. This is one reason why replacing a breaker solely on the basis of its nominal current rating is not sufficient.

5. Electronic Protection and Monitoring

Depending on the installed trip unit and accessories, a Masterpact breaker may provide adjustable protection settings and additional electrical information. Some configurations support measurement, alarm indication, trip-event information, and communication with supervisory systems.

These capabilities must not be assumed for every MT16N1-marked unit. The actual trip unit, auxiliary modules, and wiring determine which functions are available.

Role in Industrial Power Distribution Systems

The MT16N1-designated breaker may be used as a major switching and protection device in low-voltage distribution systems. Its exact role depends on the electrical design, installed configuration, and protection coordination requirements.

Main Incoming Protection

In a suitable distribution assembly, an air circuit breaker can be installed at the main incoming supply to provide switching and protection for downstream distribution equipment.

Engineers must verify the supply characteristics, maximum load current, prospective short-circuit current, grounding arrangement, and required protection functions before selecting the breaker.

Distribution Feeder Protection

Air circuit breakers can also protect high-current feeders supplying industrial machinery, distribution sections, or large electrical loads.

Protection coordination with downstream breakers is important. The objective is to ensure that a fault is cleared by the appropriate protective device wherever the system design permits, limiting unnecessary interruption to unaffected equipment.

Switchgear Integration

A circuit breaker must be compatible with the switchgear enclosure, mounting system, busbars, terminal arrangement, and required electrical clearances.

The physical dimensions and mounting method of the exact breaker are therefore as important as its electrical ratings. A fixed breaker and a drawout breaker may require different supporting structures and accessories.

Industrial Monitoring and Control

When suitable auxiliary contacts or compatible communication accessories are installed, breaker status and certain electrical or trip-related information may be integrated into a monitoring system.

The availability of these functions depends on the specific configuration. Before planning PLC, SCADA, or building-management integration, verify the installed accessories and supported interface.

Industrial Applications

Masterpact air circuit breakers are commonly used in electrical distribution applications where high-current switching and protection are required. The suitability of an MT16N1-designated unit must be assessed against the actual system requirements.

1. Industrial Main Distribution Boards

Factories often require a main distribution board to supply production lines, motor-control centers, lighting systems, and auxiliary equipment. An appropriately rated air circuit breaker can serve as a major protective and switching device within this arrangement.

The breaker must be coordinated with the incoming supply, busbar rating, downstream feeders, and the installation’s fault-current level.

2. Manufacturing Facilities

Manufacturing plants may have large connected loads from production machinery, compressors, pumps, conveyors, and process equipment. Air circuit breakers can help protect the main distribution system and selected high-current circuits.

The required current rating and trip characteristics should be determined from the load assessment and electrical protection study, not solely from the size of the existing breaker.

3. Commercial and Industrial Buildings

Large buildings may use air circuit breakers in main switchboards supplying multiple distribution sections. These systems require reliable protection, suitable isolation arrangements, and coordination with downstream circuits.

The breaker must be selected according to the building’s voltage, fault level, service conditions, and applicable electrical regulations.

4. Motor-Control Centers

Industrial motor-control centers can include feeders for large motors, pumps, fans, and other electrical equipment. An air circuit breaker may provide upstream protection for a distribution section or a dedicated feeder where its ratings and protection functions are appropriate.

Motor starting currents, downstream protection, and coordination with motor starters or variable frequency drives must be evaluated as part of the overall design.

5. Critical Power Distribution

Facilities that require controlled electrical distribution may use air circuit breakers as part of a broader protection and isolation strategy. Depending on the system design, additional monitoring and control equipment may support operational visibility and maintenance planning.

A breaker alone does not provide redundancy or uninterrupted power. Those capabilities depend on the architecture of the complete electrical system.

Installation and System Integration

Air circuit breakers operate in high-energy electrical environments. Installation, inspection, and commissioning must be performed by qualified personnel using the applicable manufacturer instructions and electrical safety procedures.

1. Verify the Complete Product Identity

Before installation, check the full catalog number, serial or identification label, current rating, pole configuration, trip unit, mounting arrangement, and accessory list.

The MT16N1 designation does not by itself establish all these details. If the existing breaker is being replaced, compare the new unit against the original nameplate and the switchgear documentation.

2. Confirm Electrical Ratings

Verify the rated operating voltage, frequency, rated current, and applicable short-circuit breaking capacity. Confirm that the breaker is suitable for the prospective fault current at the installation point.

The N1 classification should be checked against the relevant product standard and voltage. Do not infer a breaking-capacity value from the designation alone.

3. Verify Dimensions and Mounting

The supplied dimensions are 301 × 276 × 196 mm. These values should be checked against the actual unit and the manufacturer’s dimensional drawing.

Ensure that the breaker fits the switchgear assembly and that the mounting arrangement, terminal positions, busbar connections, and clearances are correct. A physically similar breaker may not fit or connect safely to the existing equipment.

4. Check Busbars and Connections

Busbars, conductors, and connection hardware must be suitable for the current and fault conditions of the installation. Follow the specified tightening torques, connection preparation, and installation sequence.

Incorrect connection practices can cause excessive contact resistance, overheating, and equipment damage. Inspection should be carried out before the equipment is energized.

5. Configure the Protection Unit

If the breaker includes an adjustable protection unit, its settings must be selected according to the protection study and applicable requirements.

Settings should coordinate with upstream and downstream protective devices, conductor ratings, equipment withstand capabilities, and required fault-clearing times. Avoid copying settings from another installation without checking whether the electrical conditions are equivalent.

6. Verify Auxiliary Functions

If the unit includes auxiliary contacts, shunt releases, undervoltage releases, motorized operating mechanisms, or communication accessories, verify their ratings and wiring before use.

Do not assume that accessories fitted to one Masterpact configuration will be compatible with every breaker carrying the same short designation.

7. Commissioning and Safety

Before energization, inspect the installation, verify mechanical operation according to the manufacturer’s procedure, and confirm that the protection settings and auxiliary circuits are correct.

Follow site lockout procedures and applicable electrical safety requirements. Never perform live work or defeat protective interlocks as a substitute for proper troubleshooting and commissioning.

Compatible System Components

The following components may be used in a complete low-voltage distribution system. Actual compatibility depends on the precise MT16N1 breaker version and the switchgear design.

Component Function Compatibility Considerations
Low-voltage switchgear assembly Houses and supports distribution equipment Verify dimensions, mounting method, clearances, and rated withstand capability
Busbar system Distributes electrical power Check current rating, short-circuit withstand, connection geometry, and insulation
Electronic trip unit Provides configured protection functions Confirm the exact trip unit and supported protection features
Auxiliary contacts Provide breaker position or status signals Verify accessory type, contact rating, and wiring
Motor operating mechanism Enables motorized opening or closing where supported Confirm that the mechanism is specified for the exact breaker
Shunt release Supports remote tripping when installed Verify voltage rating, accessory compatibility, and control-circuit design
Undervoltage release Provides release functionality associated with supply voltage conditions Confirm the required accessory and control logic
Upstream protective device Provides coordinated upstream protection Perform a protection coordination assessment
Downstream circuit breakers Protect outgoing feeders Verify selectivity, fault ratings, and trip coordination
Monitoring or SCADA system Supervises compatible status and electrical data Confirm the installed communication and measurement accessories

These are system-level examples rather than a list of accessories included with every MT16N1-designated breaker.

Alternative Models and Replacement Considerations

If the MT16N1 unit is being replaced, selection should be based on the complete electrical and mechanical specification. A newer Masterpact model may be suitable, but a direct replacement cannot be assumed from the 1600 A rating alone.

Alternative or Related Option Considerations
Compatible Masterpact MT replacement Verify the complete catalog number, trip unit, frame, pole count, and mounting arrangement
Masterpact NT family May be considered for certain legacy distribution applications, subject to engineering compatibility review
Masterpact MTZ family A newer product family that may offer updated protection and monitoring options; dimensional and system changes may be necessary
Another manufacturer’s 1600 A ACB Requires a detailed comparison of electrical ratings, physical fit, protection functions, and applicable standards

Before approving a replacement, compare:

  • Rated operating voltage and frequency.
  • Rated current and temperature-related derating requirements.
  • Short-circuit breaking and withstand capabilities.
  • Number of poles and neutral configuration.
  • Fixed or drawout mounting arrangement.
  • Trip unit type and protection settings.
  • Terminal and busbar connection geometry.
  • Auxiliary contacts and release accessories.
  • Communication and monitoring requirements.
  • Physical dimensions, clearances, and switchgear compatibility.

A replacement project may require modifications to the switchgear, control wiring, protection settings, and commissioning documentation. Any proposed substitute should be reviewed by a qualified electrical engineer or responsible switchgear specialist.

Key Advantages

High-Current Distribution Capability

The Masterpact MT family is intended for low-voltage power distribution applications requiring substantial current-carrying and switching capability. The exact limits must be confirmed for the installed model.

Circuit Protection

When equipped with a compatible protection unit and correctly configured, the breaker can protect electrical circuits against specified overload and short-circuit conditions.

Integration into Industrial Switchgear

Air circuit breakers can form part of main distribution boards, industrial switchgear, and large feeder systems when the electrical and mechanical interfaces are properly matched.

Configurable Protection Options

Depending on the installed trip unit, a Masterpact configuration may support adjustable protection functions and additional monitoring capabilities.

Maintenance and Lifecycle Support

Correct identification of the complete catalog number helps maintenance teams assess spare-part availability, evaluate replacements, and document changes to the electrical distribution system.

System-Level Monitoring Potential

With suitable accessories, some configurations can provide breaker status or electrical data to a supervisory system. These functions depend on the actual installed hardware.

Technical FAQs

1. What is the Schneider Electric MT16N1?

MT16N1 is a designation associated with the Masterpact MT air circuit breaker family and a 1600 A frame rating with N1 breaking-capacity classification. The complete catalog number is needed to identify the exact breaker configuration.

2. Is the MT16N1 an air circuit breaker?

Yes, the designation is commonly associated with a Masterpact MT air circuit breaker. Confirm the product label and complete ordering reference when identifying a specific unit.

3. What is the rated current?

The designation is associated with a 1600 A frame rating. The actual rated current and permitted operating conditions should be verified from the breaker nameplate and technical documentation.

4. What does N1 mean?

N1 is a breaking-capacity classification used within the relevant Masterpact product range. The corresponding interrupting capability depends on the applicable standard and rated voltage. Always check the exact product documentation.

5. Is the MT16N1 suitable for main distribution protection?

It may be suitable for a properly engineered main distribution application if its electrical ratings, protection configuration, and mounting arrangement match the installation. A protection study and verification of the actual product specification are necessary.

6. Does every MT16N1 have an electronic trip unit?

Not necessarily. The exact trip unit and associated protection features must be identified from the complete catalog number and the installed hardware.

7. Can the MT16N1 be integrated with a PLC or SCADA system?

Integration may be possible when the breaker is fitted with compatible auxiliary contacts, measurement equipment, or communication accessories. Verify the actual configuration and supported interfaces before planning the connection.

8. Can a newer Masterpact breaker replace the MT16N1?

Potentially, but not automatically. The replacement must match the electrical requirements and be compatible with the switchgear, busbars, protection settings, control wiring, and required accessories.

9. What should be checked before purchasing a used breaker?

Verify the complete catalog number, nameplate ratings, pole count, trip unit, mounting arrangement, accessory configuration, physical condition, and available inspection or test records. For critical distribution equipment, use qualified personnel to assess the unit before installation.

10. Are the supplied dimensions of 301 × 276 × 196 mm confirmed?

These are the listing dimensions provided for this product. Because dimensions can vary by breaker generation and mounting configuration, confirm the measurements against the actual unit and its manufacturer drawing before designing a panel or planning shipment.

Procurement and Maintenance Recommendations

When purchasing the Schneider Electric MT16N1 Circuit Breaker, begin by verifying the complete catalog number and nameplate. The short designation alone may not identify the pole configuration, trip unit, mounting type, or all required accessories.

For new, surplus, or refurbished equipment, request clear photographs of the nameplate, front face, terminals, and mounting interface. Confirm the unit’s condition, available inspection or test documentation, and the supplier’s warranty and return terms.

Check that the rated current, operating voltage, breaking capacity, and protection functions match the intended installation. Confirm the physical dimensions and connection geometry before placing an order, especially when replacing an existing breaker in a fixed switchgear assembly.

Maintenance should follow the manufacturer’s requirements and the site’s electrical safety procedures. Qualified personnel should inspect the operating mechanism, contacts and connection points as appropriate, auxiliary circuits, protection settings, and any installed monitoring accessories. Testing and servicing intervals should reflect the equipment condition, operating environment, fault history, and applicable standards.

For replacement projects, document the original protection settings and accessory configuration before removing the existing breaker. Any substitute should undergo a formal compatibility review and the required commissioning checks before being returned to service.

Conclusion

The Schneider Electric MT16N1 designation is associated with the Masterpact MT air circuit breaker family and a 1600 A frame rating with N1 breaking-capacity classification. These breakers are used in low-voltage power distribution applications where appropriate switching and circuit protection are required.

For procurement and replacement, the complete catalog number is essential. Confirm the actual current and voltage ratings, trip unit, mounting arrangement, short-circuit capability, accessories, and physical dimensions before installation. Accurate identification and proper engineering verification help ensure that the selected breaker is suitable for the intended electrical distribution system.