Our advantage
Global Logistics
We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.
Brand new and original
Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.
24-hour service
We provide 7*24 hours service to our customers. We will be there whenever you need us.
Price advantage
All our products are priced very favorably because we have our own warehouse and supply.
| Company Information | |||
| [email protected] | |||
| Mobile | +8615980777398 | ||
| +8615980777398 | |||
| 15980777398 |

The Schneider Electric MT10N1 Circuit Breaker is a high-current industrial air circuit breaker associated with the Masterpact MT product family. It is designed for use in electrical distribution systems where reliable switching, overload protection, and short-circuit fault interruption are essential to the safe operation of industrial and commercial facilities.
Air circuit breakers are commonly installed in main distribution boards, switchboards, and large electrical panels. They help protect electrical systems by interrupting current when operating conditions exceed the limits of the protection settings. Depending on the installed trip unit and breaker configuration, they can also support system monitoring, adjustable protection settings, and coordinated power distribution.
The MT10N1 designation is associated with a 1000 A rated-current configuration. Certain identified units carry a Micrologic 5.0A electronic trip unit, which provides electronic protection functions. Because the MT10N1 designation alone may not specify every electrical and mechanical option, the complete nameplate and catalog information should be checked before selecting the breaker for a new installation or replacement project.
This model is relevant to industrial facilities that require high-current circuit protection, including manufacturing plants, process-control installations, large commercial buildings, and electrical distribution systems. It may also be encountered in maintenance and refurbishment projects involving existing Masterpact switchgear.
The supplied listing dimensions are 301 × 276 × 196 mm, with a weight of 14 kg. These figures should be confirmed against the actual breaker, its accessories, and its packaging before being used for enclosure design or shipping calculations.
| Parameter | Specification |
|---|---|
| Brand | Schneider Electric |
| Product Family | Masterpact MT |
| Model | MT10N1 |
| Product Type | Air Circuit Breaker |
| Rated Current | 1000 A for the identified configuration |
| Trip Unit | Micrologic 5.0A on the identified configuration; verify the actual unit |
| Protection Functions | Overload and short-circuit protection, subject to installed trip unit and settings |
| Rated Operational Voltage | Confirm from the complete catalog number and nameplate |
| Number of Poles | Confirm from the installed breaker configuration |
| Ultimate Breaking Capacity | Verify for the exact voltage and breaker version |
| Rated Short-Time Withstand Current | Confirm from the nameplate and technical documentation |
| Installation Type | Depends on the specific fixed or withdrawable configuration |
| Dimensions Provided | 301 × 276 × 196 mm |
| Weight Provided | 14 kg |
| Typical Application | High-current industrial and commercial power distribution |
Important: The table distinguishes the identified model information from details that must be confirmed on the exact unit. Do not use unverified voltage, pole, or breaking-capacity values for electrical design.
An air circuit breaker performs switching and protective functions within a power distribution system. Its main purpose is to interrupt current when a fault or abnormal electrical condition requires disconnection.
During normal operation, the breaker allows current to flow through its main contacts to the connected load. Depending on the installed mechanism and configuration, it can be operated to connect or disconnect a circuit.
This switching capability is important in electrical distribution systems where operators and maintenance personnel need to isolate sections of a switchboard for inspection, testing, or planned maintenance.
The breaker must be operated within its rated limits and according to the manufacturer’s procedures.
An overload occurs when a circuit carries more current than intended for a sustained period. If not addressed, excessive current can cause overheating in conductors, busbars, transformers, and connected equipment.
An electronic trip unit such as the identified Micrologic 5.0A can provide adjustable long-time protection. The settings must be selected to match the circuit’s design current, conductor capacity, equipment requirements, and protection coordination study.
A correct setting helps distinguish permissible operating conditions from sustained overloads that require interruption.
A short circuit can produce a rapid and substantial increase in current. If the fault is not cleared promptly, it can cause severe thermal and mechanical stress on electrical equipment.
The breaker uses its trip mechanism and interrupting assembly to disconnect the affected circuit when the detected fault meets the configured protection criteria.
The selected breaker must have a suitable breaking capacity for the prospective short-circuit current at the installation point. This value depends on the supply system, transformer impedance, upstream equipment, and installation design.
Electronic trip units monitor electrical conditions and determine when the breaker should trip. Depending on the installed version, they may support multiple protection functions and adjustable thresholds.
Protection settings should be selected by qualified personnel using the system’s load data, conductor ratings, fault calculations, and coordination requirements. Incorrect settings can compromise protection or cause unnecessary interruptions.
A circuit breaker can support isolation procedures when the specific device is suitable for the intended isolation function and is used according to the applicable requirements.
However, switching a breaker to the open position should not be treated as a substitute for a complete safe-work procedure. Personnel must follow the appropriate isolation, lockout, and verification procedures before working on electrical equipment.
The MT10N1 can form part of the main or feeder protection arrangement in a high-current electrical distribution system. Its function is to help manage current flow, disconnect faults, and support safe maintenance practices.
In a main switchboard, a suitably rated air circuit breaker may protect an incoming feeder or a major section of the distribution system. It helps isolate downstream faults and supports the coordination of protective devices throughout the facility.
The breaker must be selected according to the supply voltage, available fault current, load profile, and protection requirements.
Industrial facilities often distribute power to multiple production areas, motor-control centers, and process systems. A high-current air circuit breaker can protect a major feeder supplying one of these sections.
Protection coordination is essential. The breaker settings should be evaluated alongside downstream breakers and upstream protective equipment to help ensure that faults are cleared by the appropriate device.
Depending on the trip unit and installed accessories, an air circuit breaker may support electrical measurement, status indication, and communication with a supervisory monitoring system.
These capabilities are configuration-dependent. Before planning integration with a PLC, SCADA platform, or energy management system, verify the exact trip unit, communication accessories, wiring interfaces, and supported protocols.
Air circuit breakers may remain in service for many years in industrial facilities. Maintenance teams may need to inspect contact condition, operating mechanisms, protection settings, and auxiliary circuits.
When replacing an existing breaker, matching the current rating alone is insufficient. The replacement must also match the switchboard arrangement, electrical ratings, mounting system, connection geometry, trip unit, and protection coordination requirements.
Large manufacturing facilities contain multiple production lines, motor-control centers, and distribution panels. A suitably configured air circuit breaker can protect high-current feeders supplying these areas.
Its role is especially important where an electrical fault could affect multiple machines or interrupt a major production process.
Main switchboards and distribution assemblies require protective devices selected according to load current and prospective fault current. An appropriately rated air circuit breaker can serve as a main or feeder breaker in these installations.
The final selection must be supported by the system’s electrical calculations and the switchboard manufacturer’s compatibility requirements.
Facilities using PLC, DCS, instrumentation, and large motor-driven equipment depend on stable electrical distribution. High-current circuit breakers can protect the power infrastructure supplying these systems.
Although the breaker is not itself a PLC or DCS controller, its protection and switching functions support the reliability of the wider automation installation.
Large buildings may have substantial electrical demand from HVAC systems, pumps, elevators, lighting, and other infrastructure. Air circuit breakers can be used in suitable main distribution or feeder positions.
The selected model must meet the building’s voltage, current, fault-level, and installation requirements.
Infrastructure facilities may require high-current protection for electrical distribution equipment, auxiliary power systems, and critical loads.
The suitability of the MT10N1 for any particular installation depends on its exact electrical configuration and the requirements of the facility’s protection scheme.
Installation should be carried out by qualified electrical personnel in accordance with the manufacturer’s documentation and applicable electrical codes.
Before installation, check the full model designation, nameplate, trip-unit type, rated current, rated voltage, pole configuration, and breaking-capacity information.
Do not assume that every breaker carrying the MT10N1 designation has identical electrical or mechanical options. Confirm the exact unit and the requirements of the intended application.
Confirm that the breaker is mechanically compatible with the switchboard or panel assembly. Important considerations include the mounting arrangement, busbar connections, terminal orientation, clearances, and any required accessories.
A breaker that fits physically may still be unsuitable if its connection system or electrical ratings do not match the installation.
The rated voltage, rated current, breaking capacity, and short-time withstand rating must be appropriate for the power distribution system.
The breaker must be capable of interrupting the prospective fault current at its installation point. This should be verified through the electrical design documentation rather than inferred from the current rating alone.
Where an electronic trip unit is installed, its settings must be reviewed before commissioning. Long-time, short-time, instantaneous, and other available protection functions should be configured according to the exact trip unit and system requirements.
Protection coordination studies should consider upstream and downstream protective devices, conductor ratings, equipment withstand capabilities, and the consequences of power interruption.
Before energizing the system, qualified personnel should inspect the breaker and associated switchgear for damage, contamination, loose or damaged connections, and signs of overheating.
Mechanical operation, interlocks, auxiliary contacts, and indication circuits should be checked according to the manufacturer’s prescribed procedure. Contact resistance or other electrical tests should be performed only using appropriate methods and acceptance criteria.
Commissioning should verify the correct installation, protection settings, operating status, and integration with the wider distribution system.
Record the breaker configuration, trip settings, test results, and relevant maintenance information. Accurate documentation helps future maintenance personnel identify the installed equipment and assess any proposed replacement.
The MT10N1 should be treated as part of a complete electrical protection and distribution assembly. The exact compatibility of accessories and connected equipment depends on the installed breaker version.
| Component | Function | Compatibility Considerations |
|---|---|---|
| Main switchboard | Houses and distributes electrical power | Verify the exact breaker mounting and connection arrangement |
| Copper or aluminium busbars | Carry current through the distribution assembly | Check current capacity, connection geometry, and temperature-rise requirements |
| Electronic trip unit | Detects abnormal electrical conditions and initiates tripping | Verify the exact trip-unit model and available functions |
| Auxiliary contacts | Provide breaker status signals | Confirm contact arrangement and electrical ratings |
| Shunt trip accessory | Allows an external signal to initiate tripping | Verify the accessory type and control voltage |
| Undervoltage release | Initiates or prevents operation under specified voltage conditions | Confirm the correct accessory and control-circuit requirements |
| Upstream protective device | Provides upstream fault protection and coordination | Check selectivity and coordination requirements |
| Downstream circuit breakers | Protect individual feeders and loads | Coordinate settings with the main breaker |
| PLC or SCADA system | Monitors selected electrical and breaker status signals | Confirm the required interface and any communication accessories |
Not every component listed above is included with the breaker. Verify the installed accessories and the required bill of materials before procurement.
When the MT10N1 needs replacement, engineers should compare the complete technical configuration rather than selecting another breaker based only on its nominal current rating.
| Replacement Option | Considerations |
|---|---|
| Another compatible Masterpact MT breaker | Verify exact electrical ratings, frame configuration, trip unit, accessories, and switchboard fit |
| A suitable Masterpact NT or NW model | Requires an engineering review of current rating, breaking capacity, dimensions, mounting, and protection functions |
| A current-generation Schneider Electric air circuit breaker | May be appropriate for an upgrade, but switchboard and connection modifications may be necessary |
| A breaker from another manufacturer | Requires a detailed assessment of electrical ratings, mechanical fit, protection coordination, and applicable standards |
Before selecting an alternative, compare:
A replacement with a similar current rating is not necessarily a direct substitute. A change of breaker family may require alterations to the switchboard, wiring, protection study, and commissioning procedure.
The identified 1000 A configuration is intended for high-current distribution applications where appropriately rated protection is required.
The identified Micrologic 5.0A configuration supports electronic protection functions. Exact functions and settings must be verified on the installed unit.
The breaker can provide switching and fault-interruption functions within a properly designed electrical distribution system.
When matched to the switchboard, the breaker can serve as part of a main or feeder protection arrangement.
Accurate model identification helps maintenance teams source suitable spare parts, inspect existing equipment, and plan replacement projects.
The Masterpact family is used in industrial and commercial electrical distribution. Correctly identifying the specific model and options is important when maintaining an existing installation.
The MT10N1 is an air circuit breaker associated with the Masterpact MT product family. The identified configuration is rated at 1000 A, with certain units carrying a Micrologic 5.0A electronic trip unit.
The identified configuration has a rated current of 1000 A. Confirm the nameplate of the actual unit before using this value in electrical design or replacement decisions.
Protection depends on the installed trip unit. The identified Micrologic 5.0A configuration supports electronic overload and short-circuit protection functions. Review the trip-unit documentation for the exact functions and settings available.
The rated voltage must be confirmed from the complete catalog information and nameplate. Do not determine the permissible operating voltage from the model designation alone.
It may be suitable for a main or feeder position when its electrical ratings, breaking capacity, installation arrangement, and protection coordination meet the requirements of the switchboard.
Monitoring and control integration depend on the installed trip unit and accessories. Auxiliary contacts or supported communication hardware may provide status or measurement information, but the required interfaces must be verified.
Verify the complete model, nameplate, trip-unit type, mechanical condition, contact condition, operating mechanism, accessories, and available test records. For critical installations, require suitable inspection and functional testing before acceptance.
The supplied listing values are 301 × 276 × 196 mm and 14 kg. A reseller listing reports approximately 16.24 kg for an MT10N1 unit. Differences may reflect measurement methods, accessories, or listing inconsistencies. Confirm the exact breaker and packaging before finalizing shipping or enclosure requirements.
Not automatically. A replacement must meet the system’s voltage, fault-level, protection, mounting, connection, and coordination requirements. The trip unit and accessory configuration should also be reviewed.
Maintenance should follow the manufacturer’s instructions and the facility’s electrical maintenance program. Depending on the breaker design and service conditions, this may include inspection, mechanical operation checks, contact and connection assessment, protection-setting review, and appropriate electrical testing.
Before purchasing the Schneider Electric MT10N1, request clear photographs of the nameplate, front panel, terminals, and trip unit. Confirm the complete product designation, rated current, voltage, breaking capacity, pole configuration, and accessory arrangement.
For used or refurbished equipment, ask for the condition, inspection scope, test records, and applicable warranty terms. Verify whether the breaker is supplied as a complete assembly or without certain accessories. For international shipment, confirm both the physical dimensions and the packed shipping weight.
During maintenance, keep the breaker and surrounding switchboard clean and ensure that electrical connections and mechanical components are inspected according to the manufacturer’s procedures. Protection settings should be documented and checked after any maintenance or replacement work.
For replacement projects, evaluate the entire installation, including busbars, mounting arrangement, upstream protection, downstream feeders, and the protection coordination study. Any change in breaker family or trip-unit configuration should be reviewed by qualified electrical engineering personnel before commissioning.
The Schneider Electric MT10N1 Masterpact air circuit breaker is associated with high-current industrial power distribution and is identified in available product information as a 1000 A configuration. With the appropriate trip unit and installation arrangement, it can provide switching, overload protection, and short-circuit interruption within a properly engineered electrical system.
Because breaker configurations can vary, the complete nameplate and installed accessories must be verified before procurement or replacement. Confirming voltage, pole configuration, breaking capacity, trip-unit functions, mounting compatibility, and protection coordination is essential for safe and reliable operation.