• Allen Bradley 1783-MMX8T Stratix 5800 Expansion Module
  • Allen Bradley 1783-MMX8T Stratix 5800 Expansion Module
  • Allen Bradley 1783-MMX8T Stratix 5800 Expansion Module
  • Allen Bradley 1783-MMX8T Stratix 5800 Expansion Module
Product Overview The Allen Bradley 1783-MMX8T is a Stratix 5800 expansion module with eight copper Ethernet ports. It is used to increase the network connection capacity of a compatible Stratix 5800 exp……
Allen Bradley 1783-MMX8T Stratix 5800 Expansion Module
  • Allen Bradley
  • 1783-MMX8T
  • Expansion Module
  • USA
  • 152.4 × 66 × 151.6 mm
  • 0.92 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 32

Our advantage

Allen Bradley 1783-MMX8T Stratix 5800 Expansion Module

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Allen Bradley 1783-MMX8T Stratix 5800 Expansion Module

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Allen Bradley 1783-MMX8T Stratix 5800 Expansion Module

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Allen Bradley 1783-MMX8T Stratix 5800 Expansion Module

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Allen Bradley 1783-MMX8T is a Stratix 5800 expansion module with eight copper Ethernet ports. It is used to increase the network connection capacity of a compatible Stratix 5800 expandable switch when the base configuration does not provide enough interfaces for the required automation devices.

The module is suited to industrial Ethernet networks that use copper connections for PLCs, distributed I/O, HMIs, drives, and other networked equipment. Its eight-port configuration allows additional devices to be incorporated into the same switching architecture without changing to a different switch platform.

The 1783-MMX8T is the basic copper expansion option within the Stratix 5800 family. It is particularly useful for control cabinets and machine networks where additional copper Ethernet connections are required.


Technical Specifications

Parameter Specification
Brand Allen Bradley
Product Model 1783-MMX8T
Product Family Stratix 5800
Product Type Expansion Module
Expansion Type Basic Expansion
Ethernet Ports 8
Port Type Copper
Port Speed 100/1000 Mbps
Network Technology Industrial Ethernet
Module Function Ethernet Network Expansion
Host Platform Stratix 5800 Expandable Switch
Typical Application Industrial Automation Networks
Dimensions 152.4 × 66 × 151.6 mm
Weight 0.92 kg

Product Features

  • Eight copper Ethernet ports for expanding the Stratix 5800 network.
  • Supports 100 Mbps and 1000 Mbps Ethernet connections.
  • Intended for use with the Stratix 5800 expandable switch platform.
  • Classified as a basic expansion module.
  • Suitable for PLC, HMI, distributed I/O, drive, and other Ethernet device connections.
  • Adds network capacity without requiring a separate standalone switch.
  • Provides a copper-interface option within the Stratix 5800 expansion family.
  • Suitable for machine-level and control-system Ethernet networks.

Working Principle

The 1783-MMX8T functions as an expansion element of a Stratix 5800 expandable switch. After installation, its eight copper Ethernet interfaces become additional connection points within the switching system.

Connected automation devices exchange Ethernet traffic through the expansion interfaces and the host switch. A typical arrangement may connect a PLC, remote I/O station, HMI, drive, and other Ethernet devices through the available copper ports.

The expansion module is useful when the base switch configuration has reached its available connection capacity. Instead of replacing the switching platform, additional network devices can be incorporated through the expansion architecture.


Role in a Stratix 5800 Industrial Ethernet Control Architecture

System Layer Typical Equipment Role of the 1783-MMX8T
Control Layer Allen Bradley PLCs and controllers Adds Ethernet connection capacity for control equipment
I/O Layer Ethernet distributed I/O Provides additional copper network connections
Drive Layer Ethernet-connected drives Connects networked motor-control equipment
HMI Layer Industrial operator terminals Provides additional network access for operator devices
Switching Layer Stratix 5800 expandable switch Hosts the expansion module
Device Layer Ethernet field and machine devices Connects additional networked equipment

Industrial Applications

Application Typical Use
Machine Automation Connecting PLCs, I/O, HMIs, drives, and other Ethernet devices
Manufacturing Cells Expanding network connections for individual production cells
Packaging Equipment Adding copper Ethernet interfaces for machine components
Material Handling Connecting networked controllers and handling equipment
Control Cabinets Increasing available Ethernet connection capacity
Industrial Networks Expanding the number of copper-connected automation devices

Installation and Maintenance

  1. Verify the host platform
    Confirm that the intended Stratix 5800 switch supports the required expansion architecture.
  2. Confirm the expansion type
    Check that an eight-port copper module is appropriate for the planned network.
  3. Inspect the module
    Check the housing and Ethernet connectors for damage before installation.
  4. Prepare the installation area
    Ensure the control cabinet provides sufficient space for the complete switching assembly.
  5. Install the module correctly
    Follow the applicable Stratix 5800 installation procedure when mounting the expansion module.
  6. Check Ethernet cables
    Use suitable industrial copper Ethernet cabling for the connected equipment.
  7. Label network connections
    Mark each cable according to the connected device to simplify troubleshooting.
  8. Check port assignments
    Confirm that connected devices correspond with the network configuration.
  9. Verify link status
    Check the Ethernet link indications after the system is energized.
  10. Check communication
    Confirm that PLCs, I/O, HMIs, drives, and other connected devices communicate as expected.
  11. Inspect connections periodically
    Check Ethernet plugs and cables for looseness, contamination, or mechanical damage.
  12. Update network documentation
    Record changes whenever devices are added, removed, or moved to different expansion ports.

Compatible System Components

Component Function
Stratix 5800 Expandable Switch Provides the main switching platform
Stratix 5800 Expansion Modules Extend the switch’s network interface capacity
Allen Bradley PLCs Provide machine and process control
Ethernet Distributed I/O Connect remote I/O to the industrial network
Ethernet Drives Provide networked motor control and diagnostics
Industrial HMIs Provide operator control and visualization
Industrial Ethernet Cables Connect automation devices to the expansion ports

Recommended Related Models

Model Product Family / Application
Allen Bradley 1783-MMX8TA Stratix 5800 expansion module with eight copper Ethernet ports and advanced features
Allen Bradley 1783-MMX8S Stratix 5800 expansion module using SFP interfaces
Allen Bradley 1783-MMX8E Stratix 5800 expansion module with PoE copper interfaces
Allen Bradley 1783-MMX6T2S Stratix 5800 expansion module combining copper and SFP interfaces
Allen Bradley 1783-MMX16T Stratix 5800 expansion module with higher copper-port capacity

Key Advantages

  • Adds eight copper Ethernet connections to the Stratix 5800 platform.
  • Supports 100 Mbps and 1000 Mbps Ethernet connections.
  • Provides a straightforward solution for expanding copper network capacity.
  • Fits machine-level and industrial control Ethernet architectures.
  • Allows additional devices to be connected through the existing switching platform.
  • Offers a basic expansion option for applications that do not require specialized expansion features.

Technical FAQs

What type of network interface does the 1783-MMX8T provide?

The 1783-MMX8T provides eight copper Ethernet interfaces. The ports support 100 Mbps and 1000 Mbps network connections, making the module suitable for standard copper-based industrial Ethernet devices.

When is an eight-port expansion module useful in a Stratix 5800 system?

It is useful when the base Stratix 5800 switch does not have enough available interfaces for the required PLCs, I/O stations, HMIs, drives, or other Ethernet equipment. The expansion module increases the available connection capacity without changing the overall switch platform.

Should the 1783-MMX8T be selected when the network requires SFP connections?

No. The 1783-MMX8T is the copper-interface option. If the application requires SFP-based network connections, a Stratix 5800 expansion model with SFP interfaces should be selected instead.

What should be considered when choosing between the 1783-MMX8T and other Stratix 5800 expansion modules?

The main considerations are the required interface type, number of connections, network architecture, and whether specialized functions such as SFP connectivity or PoE are required. The 1783-MMX8T is appropriate when eight copper Ethernet connections are sufficient and advanced expansion functions are not needed.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501