• Allen Bradley 1783-MMX16E Stratix 5800 Expansion Module
  • Allen Bradley 1783-MMX16E Stratix 5800 Expansion Module
  • Allen Bradley 1783-MMX16E Stratix 5800 Expansion Module
  • Allen Bradley 1783-MMX16E Stratix 5800 Expansion Module
Product Overview The Allen Bradley 1783-MMX16E is a Stratix 5800 expansion module used to extend the network interface capability of a compatible industrial Ethernet switching platform. It forms part of……
Allen Bradley 1783-MMX16E Stratix 5800 Expansion Module
  • Allen Bradley
  • 1783-MMX16E
  • Expansion Module
  • USA
  • 152.4 × 77.2 × 151.6 mm
  • 1.81 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 42

Our advantage

Allen Bradley 1783-MMX16E Stratix 5800 Expansion Module

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Allen Bradley 1783-MMX16E Stratix 5800 Expansion Module

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Allen Bradley 1783-MMX16E Stratix 5800 Expansion Module

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Allen Bradley 1783-MMX16E Stratix 5800 Expansion Module

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Allen Bradley 1783-MMX16E is a Stratix 5800 expansion module used to extend the network interface capability of a compatible industrial Ethernet switching platform. It forms part of the Stratix 5800 network infrastructure and is intended for installations where the existing switching arrangement needs additional connectivity.

In an industrial automation cabinet, Ethernet-based controllers, remote I/O, drives, HMIs, and intelligent field devices often share a common network infrastructure. An expansion module allows the network architecture to be extended without treating the added connectivity as a separate control system.

The 1783-MMX16E is therefore suited to network expansion, machine modernization, and plant-floor automation projects based on the Stratix 5800 platform. It can also be relevant during maintenance when an existing network configuration needs additional interface capacity while retaining the established switching architecture.


Technical Specifications

Parameter Specification
Manufacturer Allen Bradley
Product Model 1783-MMX16E
Product Type Expansion Module
Product Family Stratix 5800
Series Stratix 5800
Module Type Network Expansion Module
Primary Function Industrial Ethernet Network Expansion
System Role Network Infrastructure
Application Industrial Automation Networking
Network Integration Compatible Stratix 5800 Switching Platform
System Function Extends Network Interface Capability
Installation Industrial Control Cabinet / Network Equipment
Dimensions 152.4 × 77.2 × 151.6 mm
Weight 1.81 kg

Product Features

  • Stratix 5800 expansion module for industrial Ethernet infrastructure
  • Extends the network connectivity of a compatible Stratix 5800 switching platform
  • Intended for managed industrial network expansion
  • Suitable for automation cabinets and plant-floor Ethernet installations
  • Supports additional network interfaces within an established switching architecture
  • Useful when additional Ethernet-connected automation equipment must be integrated
  • Suitable for machine-network expansion and plant network modernization
  • Integrates with the Allen Bradley Stratix industrial networking platform
  • Can be used during network infrastructure upgrades and maintenance
  • Functions as a network infrastructure component rather than a PLC or I/O module

Working Principle

The 1783-MMX16E operates as an expansion component within a compatible Stratix 5800 switching architecture. Once installed with the host switching platform, it contributes additional network connectivity to the overall Ethernet infrastructure.

Ethernet devices connected to the automation network exchange data through the switching system. Controllers can communicate with remote I/O, drives, HMIs, and other networked equipment, while the Stratix infrastructure manages the movement of Ethernet traffic between the connected network segments and devices.

Automation Devices → Ethernet Connections → Stratix 5800 Switching Platform → 1783-MMX16E → Industrial Network

The expansion module does not execute PLC programs, process field signals, or perform machine control. Its function is concentrated on network infrastructure and the connectivity required for communication between industrial automation devices.

When expanding an existing network, the module should be considered together with the host switch, network topology, connected devices, cabling, and configuration. A physically correct installation still requires appropriate network configuration and communication testing before the system is returned to normal operation.


Role in an Allen Bradley Stratix 5800 Industrial Ethernet Control Architecture

The 1783-MMX16E occupies the network expansion layer within a Stratix 5800 industrial Ethernet architecture. It works with the compatible switching platform to accommodate additional network connectivity while the controller, I/O, motion, and supervisory devices perform their respective automation functions.

System Layer Typical Component Function
Supervisory Layer HMI / SCADA System Provides operator visualization and supervisory functions
Control Layer Allen Bradley PLC / Controller Executes machine or process control logic
Network Infrastructure Stratix 5800 Managed Switch Manages Ethernet communication between connected devices
Network Expansion 1783-MMX16E Extends the connectivity capability of the switching architecture
I/O Layer Ethernet-Based Remote I/O Exchanges field data with the control system
Motion Layer Ethernet-Connected Drive Communicates motion and drive information
Device Layer Networked Instruments / Devices Exchanges process and equipment information
Field Process Industrial Machinery Performs the controlled production or process operation

Industrial Applications

Application Expansion Module Role
Factory Automation Extends network infrastructure for Ethernet-connected automation equipment
Machine Networks Supports additional connectivity within automation cells
Packaging Machinery Integrates additional networked control and machine devices
Material Handling Expands communication infrastructure across automated handling systems
Manufacturing Lines Accommodates additional networked stations and control equipment
Process Automation Supports expansion of industrial Ethernet communication infrastructure
Plant Network Expansion Adds connectivity within an established Stratix 5800 architecture
Automation Modernization Supports network upgrades while retaining compatible switching infrastructure

Installation and Maintenance

  1. Verify host compatibility — Confirm that the 1783-MMX16E is intended for use with the specific Stratix 5800 switching platform before installation.
  2. Review the network topology — Determine where the expansion module fits within the existing industrial Ethernet architecture.
  3. Isolate the equipment as required — Follow the applicable electrical and network maintenance procedures before installing or replacing the module.
  4. Inspect the expansion module — Check the housing and accessible connection areas for visible damage, contamination, or other installation concerns.
  5. Inspect the host switch — Verify that the associated Stratix 5800 switching platform is suitable for the planned expansion.
  6. Install the module correctly — Follow the applicable equipment installation procedure and ensure the expansion module is mechanically secured.
  7. Verify the module interface — Confirm that the module is properly engaged with the compatible switching platform.
  8. Check network cabling — Verify that Ethernet cables are connected to the intended interfaces and routed without unnecessary mechanical stress.
  9. Review configuration settings — Compare the network configuration with the approved network design before placing the expanded system into service.
  10. Test connected equipment — Confirm communication between the expanded switching infrastructure and the connected controllers, I/O, drives, HMIs, and other Ethernet devices.
  11. Monitor network behavior — Check for communication interruptions, interface faults, configuration problems, or unexpected network conditions during commissioning.
  12. Update maintenance records — Record the expansion module, host switch, network connections, and relevant configuration information for future troubleshooting and system maintenance.

Related Components

Component Function
Allen Bradley Stratix 5800 Managed Switch Provides the host industrial Ethernet switching platform
Industrial Ethernet Cable Provides physical network connections between automation devices
Allen Bradley PLC / Controller Executes machine or process control logic
Ethernet-Based Remote I/O Exchanges field data with the control system
Allen Bradley HMI Provides operator visualization and equipment status
Ethernet-Connected Servo Drive Exchanges motion and drive information through the industrial network
Networked Automation Devices Provide process, equipment, and diagnostic information
Industrial Control Cabinet Houses the network and automation infrastructure

Recommended Related Models

Model Product Type Typical Relationship
Allen Bradley 1783-MMS10R Stratix 5800 Managed Switch Associated Stratix 5800 switching platform
Allen Bradley 1783-MMX14T2S Stratix 5800 Expansion Module Related Stratix 5800 expansion configuration
Allen Bradley 1783-MMS4S Stratix 5800 Managed Switch Related managed industrial Ethernet switch
Allen Bradley 1783-MMS10T2C Stratix 5800 Managed Switch Related Stratix 5800 managed networking model
Allen Bradley 1783-BMS20CGN Stratix 5700 Managed Switch Related Allen Bradley managed industrial Ethernet platform

Key Advantages

  • Extends network connectivity within a compatible Stratix 5800 architecture
  • Supports expansion of industrial Ethernet infrastructure
  • Integrates with Allen Bradley Stratix network systems
  • Suitable for machine and plant-floor automation networks
  • Useful for network expansion and modernization projects
  • Accommodates additional Ethernet-connected automation equipment
  • Functions as a dedicated network infrastructure component

Technical FAQs

What is the purpose of the Allen Bradley 1783-MMX16E?

The 1783-MMX16E is a Stratix 5800 expansion module intended to extend the network connectivity of a compatible switching platform. It forms part of the industrial Ethernet infrastructure rather than performing PLC or I/O processing.

Does the 1783-MMX16E function as a standalone PLC or network controller?

No. It is an expansion component for the Stratix 5800 network architecture. Control logic remains the responsibility of the PLC or controller, while the switching infrastructure handles industrial Ethernet communications.

What should be checked before installing the 1783-MMX16E?

The host Stratix 5800 platform, module compatibility, installation arrangement, Ethernet connections, network topology, and applicable configuration should all be checked. The planned expansion should also be consistent with the existing network documentation.

How should a network be tested after adding the expansion module?

After installation, verify the physical connections first, then check communication between the switching infrastructure and connected controllers, I/O systems, drives, HMIs, and other Ethernet devices. Any communication problem should be investigated through the physical connection, interface, and network configuration layers.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501