The Allen-Bradley 20G1AJD485AN0NNNNN is a high-power PowerFlex 755 air-cooled AC drive designed for large industrial motor-control applications.
It is part of the PowerFlex 750-Series and belongs specifically to the PowerFlex 755 product family. The unit is intended for applications requiring substantial motor power, high output current, industrial enclosure protection, network communication, adjustable-speed operation, and reliable control of large motors.
The drive is designed for a 480 VAC, three-phase electrical system and provides a nominal 485 A output-current rating. It uses a large Frame 8 construction and an IP54 / NEMA Type 12, 800 mm deep MCC-style enclosure.
The catalog configuration is rated at approximately 450 HP for Light-Duty applications, 400 HP for Normal-Duty applications, and 350 HP for Heavy-Duty applications.
The drive uses forced-air cooling and is configured with AC input and precharge, no DC terminals, an EMC filter, the CM jumper removed, and no dynamic-braking option. It also incorporates embedded EtherNet/IP communication.
The final AN0 portion of the catalog number indicates the configuration without the enhanced local HIM option. This makes the model appropriate for installations where local operator-interface hardware is not required as part of the basic drive package.
| Item | Specification |
|---|---|
| Brand | Allen-Bradley |
| Product Family | PowerFlex 750-Series |
| Product Series | PowerFlex 755 |
| Product Type | Air-Cooled AC Drive |
| Catalog Number | 20G1AJD485AN0NNNNN |
| Configuration | Packaged AC Drive |
| Cooling | Forced Air |
| Frame Size | Frame 8 |
| Input Voltage | 480 VAC |
| Input Phase | Three Phase |
| Rated Current | 485 A |
| Light-Duty Rating | 450 HP |
| Normal-Duty Rating | 400 HP |
| Heavy-Duty Rating | 350 HP |
| Enclosure | IP54 |
| NEMA Enclosure | Type 12 |
| Cabinet Style | 800 mm Deep MCC Style |
| Input Configuration | AC Input with Precharge |
| DC Terminals | None |
| EMC Filter | Included |
| CM Jumper | Removed |
| Dynamic Braking | None |
| Local HIM | None / Blank Configuration |
| Communication | Embedded EtherNet/IP |
| Mounting Style | Floor Standing |
| Main Application | Large Industrial Motor Control |
The catalog configuration identifies the 20G1AJD485AN0NNNNN as a PowerFlex 755 AC drive with embedded EtherNet/IP, air cooling, 485 A capacity, 480 VAC three-phase input, Frame 8 construction, IP54 / Type 12 protection, EMC filtering, removed CM jumper, no dynamic braking, and no local HIM.
The 20G1AJD485AN0NNNNN is positioned in the high-power range of the PowerFlex 755 family.
This is not a small machine-level variable-frequency drive.
It is a large industrial drive intended for motors in the several-hundred-horsepower range, where the electrical system, mechanical load, thermal management, and control architecture all require careful engineering.
The 485 A current rating provides additional capacity compared with the 430 A version of the same family.
This makes the model particularly useful when a 430 A-class drive is close to its application limit and additional current capacity is desirable.
The drive can be used for both variable-torque and more demanding constant-torque industrial applications, provided the motor current and overload requirements are within the applicable duty rating.
Typical applications include large pumps, fans, blowers, conveyors, material-handling systems, water-treatment equipment, mining equipment, cement machinery, process systems, and other large industrial machines.
| Parameter | Specification |
|---|---|
| Catalog Number | 20G1AJD485AN0NNNNN |
| Brand | Allen-Bradley |
| Series | PowerFlex 755 |
| Product Family | PowerFlex 750-Series |
| Product Type | Air-Cooled AC Drive |
| Input Voltage | 480 VAC |
| Input Frequency | 50/60 Hz class |
| Input Phase | 3 Phase |
| Rated Output Current | 485 A |
| Light-Duty Motor Rating | 450 HP |
| Normal-Duty Motor Rating | 400 HP |
| Heavy-Duty Motor Rating | 350 HP |
| Frame | Frame 8 |
| Cooling Method | Forced Air |
| Enclosure | IP54 |
| NEMA Rating | Type 12 |
| Cabinet Type | 800 mm Deep MCC Style |
| Input Arrangement | AC Input with Precharge |
| DC Terminals | None |
| EMC Filter | Yes |
| Common-Mode Configuration | CM Jumper Removed |
| Dynamic Braking | None |
| HIM | Blank / No HIM |
| Network Interface | Embedded EtherNet/IP |
| Installation | Floor Standing |
| Approx. Height | 2477 mm class |
| Approx. Width | 600 mm class |
| Approx. Depth | 800 mm |
| Approx. Weight | Approximately 644 kg |
| Weight Unit | kg |
| Main Use | Large Industrial Motor Control |
The 480 V selection data places the 485 A model at 450 HP Light Duty, 400 HP Normal Duty, and 350 HP Heavy Duty, with a Frame 8 configuration.
The most important characteristic of the 20G1AJD485AN0NNNNN is its 485 A output-current capability.
The drive is designed for a 480 VAC three-phase power system.
The available motor rating depends on the required duty classification.
| Duty Classification | Continuous Current | 1-Minute Overload | 3-Second Overload | Motor Rating |
|---|---|---|---|---|
| Light Duty | 485 A | 534 A | Not applicable | 450 HP |
| Normal Duty | 414 A | 621 A | 745 A | 400 HP |
| Heavy Duty | 414 A | 621 A | 745 A | 350 HP |
The Light-Duty rating provides the highest horsepower capability.
The Normal-Duty and Heavy-Duty ratings reduce the continuous motor-power rating because these operating modes require greater overload capability.
This distinction is important when selecting the drive.
A motor should not be selected solely by comparing horsepower numbers.
The actual motor nameplate current, application load profile, acceleration requirements, overload frequency, ambient temperature, and operating cycle should all be considered.
The Light-Duty rating is approximately 450 HP.
The continuous output-current rating is approximately 485 A.
This rating is particularly suitable for large variable-torque loads where the motor normally operates without severe overload conditions.
Typical applications include:
Variable-torque equipment can often benefit from adjustable-speed operation because the motor does not always need to operate at full speed.
Under the Normal-Duty classification, the drive supports approximately 400 HP.
The continuous current is approximately 414 A.
The short-duration overload capability is higher than the continuous rating.
This makes the configuration appropriate for applications with moderate mechanical loading and occasional overload requirements.
Examples include:
The Normal-Duty rating provides a useful middle point between energy-oriented variable-torque operation and more demanding Heavy-Duty applications.
For Heavy-Duty applications, the motor rating is approximately 350 HP.
The continuous current is approximately 414 A, with increased short-duration overload capability.
Heavy-Duty selection is appropriate when the application involves demanding acceleration, high mechanical loading, or repeated overload conditions.
Potential applications include:
The Heavy-Duty rating should always be checked against the actual motor full-load current and overload requirements.
The Frame 8 designation places this drive in the large physical-size category of the PowerFlex 755 family.
The unit is designed as a floor-standing industrial drive rather than a compact wall-mounted inverter.
A large frame is necessary because of the amount of electrical power being handled.
The cabinet accommodates high-power switching components, bus components, cooling equipment, control electronics, power connections, and associated electrical hardware.
For project planning, the physical envelope is approximately:
2477 mm high × 600 mm wide × 800 mm deep
with a planning weight of approximately 644 kg.
The actual installation drawing should be used for final mechanical design, lifting arrangements, transportation, and service-clearance calculations.
| Mechanical Parameter | Approximate Specification |
|---|---|
| Catalog Number | 20G1AJD485AN0NNNNN |
| Frame Size | Frame 8 |
| Height | Approximately 2477 mm |
| Width | Approximately 600 mm |
| Depth | Approximately 800 mm |
| Cabinet Depth | 800 mm |
| Cabinet Style | MCC Style |
| Enclosure | IP54 |
| NEMA Rating | Type 12 |
| Approximate Weight | Approximately 644 kg |
| Weight | Approximately 644 kg |
| Mounting | Floor Standing |
| Cooling | Forced Air |
| Service Access | Front / cabinet service area |
| Installation Type | Industrial Electrical Room |
The dimensions and weight above should be treated as practical planning values.
For a final installation drawing, the exact mechanical documentation for the configured unit should be used.
This is especially important because the unit is approximately 2.5 meters high and weighs several hundred kilograms.
The drive uses an IP54 / NEMA Type 12 enclosure configuration.
This provides a significantly more protected installation than an open-frame or basic IP20 drive.
It is suitable for many indoor industrial environments.
Typical installation locations include:
The enclosure does not eliminate the need for proper environmental control.
Excessive moisture, corrosive gases, conductive dust, extreme temperatures, or heavy contamination can still affect equipment reliability.
The 20G1AJD485AN0NNNNN is an air-cooled PowerFlex 755 drive.
At this power level, heat management becomes a major engineering consideration.
The power semiconductors and other electrical components generate heat during operation.
Forced-air cooling moves air through the drive to remove this heat.
The installation therefore needs sufficient ventilation and appropriate clearance.
If several large drives are installed in the same electrical room, the combined heat output should be considered in the room’s HVAC design.
Blocked airflow, dirty filters, failed fans, or excessive ambient temperature can increase thermal stress.
The drive uses an AC input with precharge.
Large VFDs contain significant DC-bus capacitance.
When incoming power is first connected, these capacitors require controlled charging.
The precharge system limits the initial charging current and allows the DC bus to reach its operating condition in a controlled manner.
This is particularly important in a large Frame 8 drive because of the substantial amount of stored electrical energy involved.
Correct upstream protection, switching equipment, grounding, and power-distribution design are essential.
The 20G1AJD485AN0NNNNN is configured with an EMC filter.
Electromagnetic compatibility is an important consideration in high-power variable-frequency drive installations.
A VFD uses high-speed switching to generate the motor output waveform.
This switching process produces high-frequency electrical components that can potentially affect:
The integrated filtering should therefore be considered together with the overall installation.
Motor-cable routing, grounding, cable shielding, separation between power and control cables, and cabinet layout remain important.
The catalog configuration specifies the CM jumper removed.
This configuration affects the common-mode behavior of the drive and its relationship with the grounding system.
The choice should be consistent with the intended electrical installation.
It should not be changed casually after installation.
When high-power drives are installed, the grounding arrangement, EMC behavior, motor-cable construction, and filter configuration should be considered as a complete system.
The 20G1AJD485AN0NNNNN is configured with no dynamic braking.
This is an important point when the drive is applied to high-inertia machinery.
When a motor decelerates, mechanical energy can be transferred back into the drive’s DC bus.
If the application requires frequent or rapid deceleration, the regenerated energy must be properly managed.
Potentially affected applications include:
Where substantial regenerative energy is expected, the braking requirements should be evaluated during the original drive-selection process.
The final portion of the catalog number indicates the AN0 configuration, which is supplied without a local HIM.
This makes the drive appropriate for installations where:
For applications requiring a local operator interface, a related HIM-equipped catalog configuration can be considered.
The absence of a HIM does not prevent the drive from being integrated into an automated control system.
The drive includes embedded EtherNet/IP communication.
This is one of the most useful characteristics of the PowerFlex 755 architecture.
The drive can become part of a centralized industrial automation network.
Typical network information can include:
This allows the drive to be integrated into larger machine-control or process-control systems.
Large water pumps are one of the most suitable applications for this drive.
The drive can regulate pump speed according to system demand.
Applications include:
Variable-speed operation can help match pump output to actual demand.
Wastewater-treatment facilities frequently use large motors.
Potential applications include:
The high-power rating of the 20G1AJD485AN0NNNNN makes it suitable for large pumping and blower systems when the motor current falls within the appropriate duty rating.
Large fans can require hundreds of horsepower.
Applications include:
The drive allows fan speed to be adjusted rather than operating the motor continuously at maximum speed.
This can provide better process control and can reduce unnecessary energy consumption when the process is suitable for variable-speed operation.
Industrial blowers are used in many process industries.
Typical applications include:
The drive can regulate blower speed and communicate operating data to the plant control system.
Large conveyors are common in:
A VFD can provide controlled acceleration and deceleration.
This can reduce mechanical shock to:
For high-inertia conveyor systems, the correct duty classification and braking requirements must be evaluated carefully.
Mining equipment frequently contains large electric motors.
The 20G1AJD485AN0NNNNN can be considered for applications such as:
The rugged floor-standing design and high current capacity are well suited to centralized industrial electrical installations.
Cement plants contain numerous large motor loads.
Potential applications include:
The PowerFlex 755 platform is useful when the drive needs to communicate with a centralized automation system.
Steel-processing plants often use large motors continuously.
Potential applications include:
The 485 A current capability provides sufficient capacity for a broad range of large industrial motor applications.
Large process plants often use pumps and fans with variable-speed requirements.
Applications can include:
Network connectivity is particularly useful in these applications because the drive can exchange operating information with the process-control system.
The 485 A rating provides substantial motor-control capability.
It allows the drive to operate large industrial motors without requiring multiple smaller drives to perform the same task.
The drive supports approximately:
This gives one drive platform a broad range of application possibilities.
The three duty classifications allow the engineer to select the drive according to actual machine loading.
This is important because two motors with the same horsepower can have very different overload requirements.
The Frame 8 design is suitable for large centralized motor-control systems.
It provides the physical space necessary for high-power electrical components and cooling equipment.
The enclosure provides useful environmental protection for many indoor industrial applications.
It is well suited to electrical rooms and controlled industrial environments.
Integrated network communication allows the drive to become part of a plant automation architecture.
This simplifies the exchange of control, status, and diagnostic information.
The integrated EMC filter supports better electromagnetic compatibility when the drive is installed correctly.
This is particularly useful in large installations with extensive control and communication wiring.
The AC input precharge arrangement is important for controlling the charging of the high-power DC bus during startup.
For centralized automation systems, the AN0 configuration can be useful because the drive does not include an enhanced local operator interface as part of the base catalog configuration.
This can be appropriate when drive control and monitoring are performed through the plant automation network.
The 20G1AJD485AN0NNNNN is closely related to the 430 A model.
| Parameter | 20G1AJD430AN0NNNNN | 20G1AJD485AN0NNNNN |
|---|---|---|
| Voltage | 480 VAC | 480 VAC |
| Rated Current | 430 A | 485 A |
| Light Duty | 400 HP | 450 HP |
| Normal Duty | 350 HP | 400 HP |
| Heavy Duty | 300 HP | 350 HP |
| Frame | 8 | 8 |
| Enclosure | IP54 / Type 12 | IP54 / Type 12 |
| Cooling | Forced Air | Forced Air |
| Cabinet Depth | 800 mm | 800 mm |
| EMC Filter | Yes | Yes |
| CM Jumper | Removed | Removed |
| Dynamic Braking | None | None |
| HIM | Blank / No HIM | Blank / No HIM |
| EtherNet/IP | Embedded | Embedded |
The 485 A version provides a higher current and horsepower capacity than the 430 A configuration.
It can therefore be a practical choice when the motor current is above the comfortable operating range of the 430 A model.
The following five models are particularly relevant because they are closely related 480 VAC PowerFlex 755 Frame 8 configurations.
| Model | Voltage | Rated Current | Light Duty | Normal Duty | Heavy Duty | Frame | Enclosure |
|---|---|---|---|---|---|---|---|
| 20G1AJD430AN0NNNNN | 480 VAC | 430 A | 400 HP | 350 HP | 300 HP | 8 | IP54 / Type 12 |
| 20G1AJD545AN0NNNNN | 480 VAC | 545 A | 500 HP | 450 HP | 350 HP | 8 | IP54 / Type 12 |
| 20G1AJD617AN0NNNNN | 480 VAC | 617 A | 600 HP | 500 HP | 400 HP | 8 | IP54 / Type 12 |
| 20G1AJD710AN0NNNNN | 480 VAC | 710 A | 650 HP | 600 HP | 450 HP | 8 | IP54 / Type 12 |
| 20G1AJD740AN0NNNNN | 480 VAC | 740 A | 700 HP | 650 HP | 500 HP | 8 | IP54 / Type 12 |
The 480 V PowerFlex 755 selection range includes these progressively higher-current configurations, providing a convenient path for selecting a larger drive when motor current or overload requirements increase.
| Model | Current | Light Duty | Normal Duty | Heavy Duty | Frame | Typical Selection |
|---|---|---|---|---|---|---|
| 20G1AJD430AN0NNNNN | 430 A | 400 HP | 350 HP | 300 HP | 8 | Lower-capacity 480 V Frame 8 |
| 20G1AJD485AN0NNNNN | 485 A | 450 HP | 400 HP | 350 HP | 8 | Main model |
| 20G1AJD545AN0NNNNN | 545 A | 500 HP | 450 HP | 350 HP | 8 | Higher-power application |
| 20G1AJD617AN0NNNNN | 617 A | 600 HP | 500 HP | 400 HP | 8 | Very large motors |
| 20G1AJD710AN0NNNNN | 710 A | 650 HP | 600 HP | 450 HP | 8 | Extremely high-power systems |
| 20G1AJD740AN0NNNNN | 740 A | 700 HP | 650 HP | 500 HP | 8 | Maximum range among these choices |
The 485 A version occupies an important position in this range.
It provides a useful step upward from the 430 A model without immediately moving to the much larger 545 A or higher-current configurations.
| Model | Frame | Approx. Height | Approx. Width | Approx. Depth | Approx. Weight |
|---|---|---|---|---|---|
| 20G1AJD430AN0NNNNN | 8 | 2477 mm class | 600 mm class | 800 mm | Approx. 644 kg |
| 20G1AJD485AN0NNNNN | 8 | 2477 mm class | 600 mm class | 800 mm | Approx. 644 kg |
| 20G1AJD545AN0NNNNN | 8 | 2477 mm class | 600 mm class | 800 mm | Approx. 644 kg |
| 20G1AJD617AN0NNNNN | 8 | 2477 mm class | 600 mm class | 800 mm | Approx. 644 kg |
| 20G1AJD710AN0NNNNN | 8 | 2477 mm class | 600 mm class | 800 mm | Approx. 644 kg |
| 20G1AJD740AN0NNNNN | 8 | 2477 mm class | 600 mm class | 800 mm | Approx. 644 kg |
The physical values should be regarded as approximate engineering-planning values.
Although these models share the Frame 8 / 800 mm MCC-style platform, exact cabinet configuration and final mechanical documentation should be used for final installation planning.
For broader comparison, the following five models represent different capacity levels and product families.
| Model | Series | Voltage Class | Approx. Power / Current | Format | Typical Application |
|---|---|---|---|---|---|
| 25B-D030N114 | PowerFlex 525 | 480 VAC Class | 30 HP class | Compact VFD | Pumps, fans, conveyors |
| 25C-D030N114 | PowerFlex 523 | 480 VAC Class | 30 HP class | Compact VFD | General machinery |
| 20G1AGE053JA0NNNNN | PowerFlex 755 | 600 VAC | 53 A | Frame 6 | Industrial process equipment |
| 20G1AGC260JN0NNNNN | PowerFlex 755 | 400 VAC | 260 A | Frame 7 | Pumps, fans, conveyors |
| 20G1AND302JA0NNNNN | PowerFlex 755 | 480 VAC Class | 302 A | Frame 7 | Heavy industrial motor control |
These models provide useful alternatives when the required motor power, voltage, enclosure, frame size, or installation format differs from the 20G1AJD485AN0NNNNN.
| Model | Product Series | Capacity Class | Main Advantage | Typical Application |
|---|---|---|---|---|
| 25B-D030N114 | PowerFlex 525 | 30 HP class | Compact and versatile | Pumps, fans, conveyors |
| 25C-D030N114 | PowerFlex 523 | 30 HP class | General-purpose machine control | Machinery |
| 20G1AGE053JA0NNNNN | PowerFlex 755 | 53 A / 600 V | Higher-voltage industrial control | Process machinery |
| 20G1AGC260JN0NNNNN | PowerFlex 755 | 260 A / 400 V | Medium/high-power control | Pumps and conveyors |
| 20G1AND302JA0NNNNN | PowerFlex 755 | 302 A / 480 V | High-power industrial control | Large machinery |
The first two models are substantially smaller than the 20G1AJD485AN0NNNNN.
They are more appropriate for compact equipment and smaller motors.
The PowerFlex 755 models are closer in architecture and application philosophy and are more appropriate when large industrial motors, process integration, and higher current are required.
| Application | Suitability | Reason |
|---|---|---|
| Large Centrifugal Pump | Excellent | High current and variable-speed capability |
| Water Transfer Pump | Excellent | Large motor and continuous operation |
| Cooling-Water Pump | Excellent | Adjustable motor speed |
| Wastewater Pump | Excellent | Large industrial pumping |
| Large Fan | Excellent | High-power variable-torque load |
| Industrial Blower | Excellent | Adjustable airflow |
| Mining Conveyor | Excellent | High motor capacity |
| Cement Conveyor | Excellent | Large material-handling systems |
| Steel Plant Auxiliary Equipment | Excellent | Large industrial motors |
| Process Pump | Excellent | Networked process control |
| Heavy Conveyor | Very Good | High current and overload capability |
| Material Handling | Very Good | Controlled acceleration |
| Small Pump | Poor / Oversized | Smaller VFD is generally more practical |
| Small Machine | Poor / Oversized | Excessive capacity |
A large pump driven by a 400–450 HP motor is a natural application for this drive.
The motor can be started with a controlled acceleration profile.
Instead of immediately applying full-speed operation, the drive can progressively increase motor speed.
Once operating speed is reached, the drive can maintain the required process speed.
If the process demand changes, the speed reference can be adjusted.
This approach is particularly useful in large water and industrial pumping systems.
The embedded EtherNet/IP interface can also allow the pump drive to exchange status and operating information with the central automation system.
A large conveyor can have considerable mechanical inertia.
Starting such a system directly at full speed can result in high mechanical stress.
A variable frequency drive allows the acceleration rate to be controlled.
This can reduce mechanical shock and improve system coordination.
The drive can also be integrated with upstream and downstream machinery through the automation network.
For demanding conveyors, the engineer should pay particular attention to:
A large industrial fan may not require maximum speed at all times.
The drive can vary the motor speed according to the process requirement.
This can improve airflow regulation.
Applications include:
For variable-torque fan applications, the Light-Duty rating can provide particularly useful horsepower capacity.
Industrial blowers often operate continuously.
The drive can provide adjustable-speed control and networked monitoring.
Potential benefits include:
The 20G1AJD485AN0NNNNN is particularly appropriate when the blower motor is within the 350–450 HP range depending on the required duty class.
Large Frame 8 drives should be incorporated into a structured preventive-maintenance program.
Maintenance personnel should regularly inspect:
Because the drive is a high-power system, abnormal conditions should be investigated before they develop into major equipment failures.
The large physical size of the unit should be considered from the beginning of the project.
The approximate dimensions are:
2477 mm × 600 mm × 800 mm
and the approximate equipment weight is:
644 kg
This means the installation team should evaluate:
The drive should not be treated like a compact wall-mounted inverter during project planning.
A large drive produces substantial heat.
When several drives are installed together, the total heat load can become significant.
The electrical room should therefore have suitable:
The cabinet should have adequate clearance for cooling and maintenance.
The environment should also be checked for:
A typical control architecture can be represented as:
PLC → EtherNet/IP Network → PowerFlex 755 → Motor
The controller can provide:
The drive can provide:
This arrangement is particularly useful in automated factories and process plants.
The 20G1AJD485AN0NNNNN provides a useful balance within the 480 V Frame 8 PowerFlex 755 range.
It is larger than the 430 A model but smaller than the 545 A, 617 A, 710 A, and 740 A configurations.
This makes it attractive when:
Before selecting the 20G1AJD485AN0NNNNN for a project, the following information should be reviewed.
| Selection Item | Requirement |
|---|---|
| Motor Voltage | Confirm 480 V-class compatibility |
| Motor Current | Confirm against applicable duty rating |
| Motor Horsepower | Check LD / ND / HD classification |
| Duty Cycle | Determine continuous and overload requirements |
| Acceleration | Check acceleration time and load inertia |
| Deceleration | Determine braking requirements |
| Regeneration | Evaluate regenerated energy |
| Environment | Check temperature, humidity, dust and contamination |
| Enclosure | Confirm IP54 / Type 12 suitability |
| Cooling | Verify ventilation and heat dissipation |
| Communication | Confirm EtherNet/IP requirements |
| HIM | Determine whether local operator interface is needed |
| EMC | Verify grounding, filtering and cable requirements |
| Physical Space | Allow approximately 2477 × 600 × 800 mm |
| Weight | Allow approximately 644 kg |
| Maintenance | Provide suitable service clearance |
| Transportation | Verify lifting and handling capacity |
| Advantage | Description |
|---|---|
| 485 A Output | High-capacity motor control |
| 450 HP LD | Suitable for large variable-torque loads |
| 400 HP ND | Strong general industrial capacity |
| 350 HP HD | Suitable for demanding loads |
| Frame 8 | Large industrial construction |
| IP54 / Type 12 | Improved enclosure protection |
| 800 mm Cabinet | Suitable for high-power equipment |
| Air Cooling | Forced-air thermal management |
| EtherNet/IP | Integrated industrial networking |
| EMC Filter | Improved electromagnetic compatibility |
| Precharge | Controlled DC-bus charging |
| No HIM | Suitable for centralized automation |
| Large Application Range | Pumps, fans, blowers, conveyors and process machinery |
| Industrial Construction | Designed for large motor-control systems |
| Category | Detailed Specification |
|---|---|
| Brand | Allen-Bradley |
| Product Family | PowerFlex 750-Series |
| Product Series | PowerFlex 755 |
| Catalog Number | 20G1AJD485AN0NNNNN |
| Product Type | Air-Cooled AC Drive |
| Input Voltage | 480 VAC |
| Phase | 3 Phase |
| Rated Current | 485 A |
| Light-Duty Rating | 450 HP |
| Normal-Duty Rating | 400 HP |
| Heavy-Duty Rating | 350 HP |
| Frame Size | Frame 8 |
| Cooling | Forced Air |
| Enclosure | IP54 |
| NEMA Rating | Type 12 |
| Cabinet Style | 800 mm Deep MCC Style |
| Input | AC Input with Precharge |
| DC Terminals | None |
| EMC Filter | Included |
| CM Jumper | Removed |
| Dynamic Braking | None |
| HIM | Blank / No HIM |
| Communication | Embedded EtherNet/IP |
| Mounting | Floor Standing |
| Approx. Height | 2477 mm |
| Approx. Width | 600 mm |
| Approx. Depth | 800 mm |
| Approx. Weight | 644 kg |
| Weight Unit | kg |
| Primary Applications | Pumps, Fans, Blowers, Conveyors, Mining, Cement, Steel, Water Treatment, Process Machinery |
| Duty Classes | Light Duty / Normal Duty / Heavy Duty |
| Main Advantage | High-power industrial motor control |
The Allen-Bradley 20G1AJD485AN0NNNNN is a high-power PowerFlex 755 AC drive designed for large industrial motor applications.
Its 485 A output capacity, 480 VAC three-phase configuration, and Frame 8 construction make it appropriate for large motors and demanding industrial systems.
The three available duty classifications provide useful flexibility.
At approximately 450 HP Light Duty, the drive is particularly attractive for large variable-torque applications such as pumps, fans, and blowers.
At approximately 400 HP Normal Duty, it provides a strong option for general industrial motor applications.
At approximately 350 HP Heavy Duty, it can be used for more demanding loads where greater overload capability is required.
The IP54 / NEMA Type 12 enclosure makes it suitable for many indoor industrial installations, while the 800 mm deep MCC-style construction provides the physical space necessary for a high-power drive system.
The forced-air cooling system is appropriate for this power level, but adequate room ventilation and maintenance access remain important.
The integrated EMC filter and AC-input precharge arrangement address important requirements associated with high-power variable-frequency drive installations.
The