Our advantage
Global Logistics
We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.
Brand new and original
Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.
24-hour service
We provide 7*24 hours service to our customers. We will be there whenever you need us.
Price advantage
All our products are priced very favorably because we have our own warehouse and supply.
| Company Information | |||
| [email protected] | |||
| Mobile | +8615980777398 | ||
| +8615980777398 | |||
| 15980777398 |

The Allen Bradley 80026-420-62-R Powerware 9130 Battery Assembly is a replacement battery assembly associated with the Powerware 9130 uninterruptible power supply (UPS) system. It belongs to the backup-power section of the UPS architecture and supports continued operation of connected equipment when the normal AC power source is interrupted.
Unlike an AC/DC power supply, the battery assembly does not primarily perform AC-to-DC conversion for the control cabinet. Its function is energy storage and backup power support. During normal operation, the UPS maintains the battery system in a charged condition. When an input-power interruption occurs, stored energy becomes available to the UPS inverter so that connected loads can continue receiving power for the available backup period.
For maintenance engineers, the 80026-420-62-R is particularly relevant when servicing an existing Powerware 9130 installation and restoring the battery portion of the UPS system.
| Parameter | Specification |
|---|---|
| Manufacturer | Allen Bradley |
| Model | 80026-420-62-R |
| Product Family | Powerware 9130 |
| Product Type | Battery Assembly |
| Application | UPS Backup Power |
| Dimensions | 438 x 86 x 438 mm |
| Weight | 12 kg |
The 80026-420-62-R is intended for battery backup applications within the Powerware 9130 UPS platform.
Key characteristics include:
Battery assemblies should be treated as system-specific service components. Before replacement, the UPS model, battery configuration, connectors, and installation arrangement should be verified.
The 80026-420-62-R operates as the stored-energy section of the Powerware 9130 UPS.
A simplified UPS power path can be represented as:
AC Utility Power → UPS Charger / Power Circuit → Battery Assembly → UPS Inverter → Protected Load
During normal operation, the UPS charging circuit maintains the battery assembly at the required state of charge. The stored electrical energy remains available for use if the incoming utility supply is interrupted.
When an input-power failure occurs, the UPS transfers its energy source to the battery system. The stored DC energy is then used by the UPS inverter to maintain power to the protected load.
This makes the battery assembly different from a conventional industrial power supply. It does not act as the primary power-conversion device for the automation cabinet; instead, it serves as the stored-energy source that allows the UPS to maintain power continuity.
The 80026-420-62-R occupies the energy-storage layer of the Powerware 9130 UPS architecture.
A simplified arrangement is:
Utility Power → UPS → Battery Assembly → Inverter → Protected Equipment
The battery assembly works together with the UPS charging system, inverter, control electronics, and protected-load connections.
In an industrial environment, the UPS may support equipment such as:
Maintaining the battery section in suitable condition is therefore important when the UPS is used to protect equipment that cannot tolerate an unexpected power interruption.
The 80026-420-62-R is applicable to installations using the Powerware 9130 UPS platform.
| Application | Typical Use |
|---|---|
| Industrial Automation | Backup power for control equipment |
| PLC Systems | Maintaining controller operation during outages |
| HMI Systems | Supporting operator-interface continuity |
| Industrial Networking | Backup power for communication equipment |
| Process Control | Protecting critical control electronics |
| Manufacturing Equipment | Supporting controlled shutdown or continued operation |
| Data and Control Cabinets | UPS battery backup |
| Plant Maintenance | Replacement of depleted battery assemblies |
The actual backup duration depends on the UPS configuration, battery condition, and connected load.
Battery replacement should be performed according to the UPS maintenance procedure and with attention to the electrical hazards associated with stored energy.
Before servicing the 80026-420-62-R, technicians should identify the UPS model and confirm that the replacement battery assembly matches the installed configuration.
Recommended checks include:
Battery assemblies should not be treated as ordinary electronic modules. Appropriate safety procedures are required because the stored electrical energy can remain hazardous even when the normal AC supply has been disconnected.
The 80026-420-62-R forms part of a larger Powerware 9130 UPS architecture.
| Component | Function |
|---|---|
| Powerware 9130 UPS | Provides uninterruptible power |
| Battery Assembly | Stores backup electrical energy |
| Battery Charger | Maintains battery charge |
| UPS Inverter | Converts stored DC energy for the protected load |
| UPS Control Electronics | Manages UPS operating functions |
| Input Power Circuit | Provides utility power |
| Output Power Circuit | Supplies protected equipment |
| Protected Load | Receives backup power from the UPS |
The battery assembly should be evaluated together with the UPS charging and inverter sections when diagnosing backup-power problems.
| Model / Product Family | Product Type | Typical Application |
|---|---|---|
| Allen Bradley 80026-420-62-R | Powerware 9130 Battery Assembly | UPS battery replacement |
| Allen Bradley 80026-172-23 | AC/DC Power Supply | Industrial control-system power |
| Allen Bradley 80026-096-01 | DC/DC Converter Power Supply | DC power conversion |
| Allen Bradley 80026-088-01 | AC/DC Switching Power Supply | AC/DC power conversion |
| Allen Bradley Powerware 9130 | UPS System | Uninterruptible power protection |
| Allen Bradley 1606 Series | Industrial Power Supply | Automation control power |
The 80026-420-62-R is specifically a battery assembly, so it should not be substituted with a conventional power supply simply because both products are associated with electrical power systems.
The 80026-420-62-R is a Powerware 9130 Battery Assembly used as the stored-energy source within the UPS system.
When the normal input supply is interrupted, the UPS uses stored energy from the battery assembly to maintain power to the protected load through the UPS inverter.
It should be investigated when the UPS reports battery-related alarms, reduced backup performance, charging problems, or an inability to maintain the expected load during a power interruption.
The Powerware 9130 configuration, complete battery assembly model, connectors, wiring, installation position, and applicable UPS maintenance procedure should be verified before replacement.