The Siemens 6AG2137-6AA00-1BA0 SIPLUS ET 200SP CM PTP T1 RAIL is an industrial serial communication module designed for integrating serial devices into Siemens ET 200SP automation systems. It supports communication through RS-232, RS-422, and RS-485 interfaces, allowing controllers and field devices to exchange data through established serial communication protocols.
This module belongs to the Siemens SIPLUS extreme product range. Compared with standard automation components, SIPLUS versions are designed for applications that require enhanced resistance to environmental influences. The 6AG2137-6AA00-1BA0 features conformal coating and an extended environmental specification for demanding industrial and railway-related applications.
The module is based on the standard Siemens 6ES7137-6AA00-0BA0 CM PtP communication module. Its serial communication capabilities support Freeport, 3964(R), USS, and Modbus RTU master and slave operation. The maximum specified transmission rate is 115.2 kbit/s.
Within an ET 200SP installation, the module provides a serial communication interface for connecting compatible devices such as instruments, controllers, barcode readers, and other equipment with RS-232, RS-422, or RS-485 interfaces. It can be used in distributed automation systems where serial communication is required alongside other digital and analog I/O functions.
The 6AG2137-6AA00-1BA0 is a discontinued product. When sourcing this module for an existing installation, buyers should verify the complete order number, firmware requirements, BaseUnit compatibility, and communication settings.
| Parameter | Specification |
|---|---|
| Brand | Siemens |
| Product Series | SIPLUS ET 200SP |
| Model | 6AG2137-6AA00-1BA0 |
| Product Designation | CM PTP T1 RAIL |
| Product Type | Serial Communication Module |
| Base Standard Module | 6ES7137-6AA00-0BA0 |
| Communication Interfaces | RS-232, RS-422, RS-485 |
| Communication Modes | Freeport, 3964(R), USS, Modbus RTU |
| Modbus Operation | Master and Slave |
| Maximum Transmission Rate | 115.2 kbit/s |
| Supply Voltage | 24 V DC |
| Permissible Supply Range | 19.2–28.8 V DC |
| Rated Current Consumption | 29 mA |
| Isolation | Galvanic isolation according to the specified module design |
| Environmental Protection | Conformal coating |
| Temperature Specification | -25 to +55 °C; 70 °C for 10 minutes |
| Mounting | ET 200SP rail-mounted installation |
| Compatible BaseUnit Type | Type A0 |
| Dimensions Provided | 78 × 64 × 23 mm |
| Weight Provided | 0.042 kg |
| Product Lifecycle | Discontinued |
| Successor Model | 6AG2137-6AA01-4BA0 |
Note: The dimensions and weight above are the supplied listing values. Confirm whether the dimensions refer to the product or its packaging before using them for mechanical installation planning.
The primary function of the 6AG2137-6AA00-1BA0 is to provide a serial communication channel between an ET 200SP automation station and external equipment. It converts communication data between the controller’s internal automation environment and the connected serial interface.
The module supports three common serial interface standards:
The choice of interface depends on the connected equipment, cable arrangement, communication distance, and electrical environment.
The module supports several communication methods for different automation applications.
Freeport allows users to implement customized serial communication procedures. It is useful when connecting devices that use a proprietary or application-specific data format.
3964(R) is a Siemens serial communication procedure used in compatible automation applications. It provides an established method for exchanging data between supported devices.
USS is a serial communication protocol commonly associated with Siemens drive communication. It can be used to exchange commands and status information with compatible drive equipment.
Modbus RTU supports master and slave operation. This allows the module to communicate with compatible instruments, controllers, and other Modbus-enabled devices.
The maximum specified transmission rate for this model is 115.2 kbit/s. Actual communication performance also depends on the protocol, cable quality, connected equipment, and network configuration.
The serial module operates as part of the ET 200SP station. Communication data is exchanged with the automation controller through the distributed I/O system.
The controller can process received information and use it in control logic, monitoring functions, or supervisory applications. Depending on the configuration, the controller can also send commands or data to connected serial devices.
The SIPLUS version includes conformal coating to provide additional protection for electronic assemblies in demanding environments. Its environmental specification is intended to support applications exposed to conditions that may be unsuitable for some standard automation modules.
Conformal coating does not make the module waterproof or eliminate the need for suitable cabinet protection. Installation must still follow the specified temperature, humidity, vibration, and contamination limits.
The 6AG2137-6AA00-1BA0 provides a serial communication connection within an ET 200SP distributed automation architecture.
The module can be used in an ET 200SP station connected to a compatible Siemens automation controller. The controller manages the station and processes communication data received from connected serial equipment.
This arrangement allows serial instruments and devices to participate in a larger PLC-based control system without requiring every field device to communicate directly through an Ethernet interface.
Industrial instruments may use RS-232 or RS-485 for configuration, measurement transmission, and operating commands. The module provides an interface for compatible devices so their data can be incorporated into the automation process.
Examples include serial meters, analyzers, measurement instruments, and selected monitoring devices.
The supported USS protocol makes the module relevant to applications involving compatible Siemens drives. It can exchange supported commands and status information through a configured serial connection.
Engineers should verify the drive’s protocol support, communication parameters, addressing, and wiring before commissioning.
Data collected through the serial interface can be processed by the PLC and made available to higher-level monitoring systems. This can help operators view equipment status, measurement values, and communication-related diagnostics through the wider automation architecture.
The SIPLUS ET 200SP T1 RAIL version is designed for demanding railway-related environments. Its environmental characteristics and railway-oriented qualification make it suitable for appropriately engineered applications involving serial communication in railway automation systems.
Potential applications include equipment monitoring, auxiliary control systems, and communication with compatible serial devices. The complete installation must comply with the relevant railway standards and environmental requirements.
Manufacturing and process facilities often contain instruments that communicate through serial interfaces. The module can connect compatible equipment to an ET 200SP station, allowing data to be incorporated into PLC control logic.
Applications may include monitoring process values, collecting instrument status, and exchanging configuration information.
Compatible drives using USS communication can exchange operating commands and status data through the serial interface. This can support motor-control applications where drive information is incorporated into a Siemens automation system.
The protocol configuration and supported functions must be checked for each connected drive.
Industrial meters and monitoring devices may provide serial communication through RS-485 or RS-232. The module can provide an interface for collecting measurement data from compatible equipment.
The resulting information may be used for energy monitoring, equipment analysis, and operational reporting.
Machines often combine PLC-controlled functions with peripheral equipment from different manufacturers. Serial communication can provide a practical way to connect devices that do not have the same industrial Ethernet interface.
The 6AG2137-6AA00-1BA0 can serve as the serial interface within a suitable ET 200SP installation.
Correct installation and configuration are essential for stable serial communication.
The module is designed for an ET 200SP installation and is specified for a Type A0 BaseUnit. Verify the exact BaseUnit type and station configuration before installation.
A module that fits physically may still be unsuitable if the BaseUnit, wiring arrangement, or station configuration is incorrect.
The specified supply voltage is 24 V DC, with a permissible range of 19.2–28.8 V DC. The rated current consumption is 29 mA.
Confirm that the station’s power arrangement meets the module requirements and that the supply remains within the specified operating range.
Choose RS-232, RS-422, or RS-485 according to the connected device. Check the pin assignments, signal references, cable type, and grounding requirements.
For RS-485 networks, pay particular attention to bus topology, termination, biasing, and the permitted number of connected devices.
Set the communication protocol and serial parameters according to the connected equipment. Depending on the application, these may include:
Both ends of the communication link must use compatible settings.
Use the appropriate Siemens engineering environment and hardware configuration for the ET 200SP station. Confirm the module identification, supported firmware, process data configuration, and communication instructions.
After downloading the configuration, test data exchange with the connected device and verify that the PLC processes the received information correctly.
Although the module has conformal coating, it should be installed in an enclosure suitable for the actual operating environment. Maintain the specified temperature limits and protect the equipment from direct water exposure, excessive contamination, and unsuitable mechanical conditions.
The 6AG2137-6AA00-1BA0 operates within an ET 200SP automation architecture and requires compatible station components and connected serial devices.
| Component | Function | Integration Considerations |
|---|---|---|
| Siemens ET 200SP station | Distributed I/O platform | Confirm station configuration and module support |
| Siemens Type A0 BaseUnit | Mechanical and electrical module interface | Required BaseUnit type must be verified |
| Siemens PLC | Controls the automation process | Confirm compatibility with the configured ET 200SP station |
| 24 V DC power supply | Provides operating power | Maintain the specified 19.2–28.8 V DC range |
| RS-232 device | Provides point-to-point serial communication | Verify pinout, signal levels, and communication settings |
| RS-422 device | Provides differential serial communication | Confirm wiring and interface compatibility |
| RS-485 device | Supports differential serial bus communication | Check topology, termination, and addressing |
| USS-compatible drive | Receives and exchanges drive information | Confirm USS support and protocol configuration |
| Modbus RTU instrument | Exchanges serial data | Configure master/slave roles and communication parameters |
| Engineering workstation | Configures and diagnoses the automation station | Use compatible Siemens engineering software and device descriptions |
These components are examples of equipment that may be used in a complete installation. They are not necessarily included with the communication module.
The 6AG2137-6AA00-1BA0 is a discontinued SIPLUS model. Siemens identifies 6AG2137-6AA01-4BA0 as its successor.
| Model | Product Description | Replacement Considerations |
|---|---|---|
| 6AG2137-6AA00-1BA0 | SIPLUS ET 200SP CM PTP T1 RAIL | Original model; supports RS-232/422/485 and up to 115.2 kbit/s |
| 6AG2137-6AA01-4BA0 | SIPLUS ET 200SP CM PTP RAIL QT4 | Successor model with a different environmental specification and maximum communication rate |
| 6ES7137-6AA00-0BA0 | Standard ET 200SP CM PtP | Standard counterpart without the same SIPLUS environmental configuration |
| 6ES7137-6AA01-0BA0 | Standard ET 200SP CM PtP | Related standard module; verify hardware and firmware compatibility |
Before selecting a replacement, compare:
The successor should not be treated as an automatic plug-in replacement without checking the complete system configuration. Differences in firmware, communication settings, environmental qualifications, and engineering configuration may require changes during migration.
Support for RS-232, RS-422, and RS-485 allows the module to connect a variety of compatible industrial devices.
Freeport, 3964(R), USS, and Modbus RTU support provide options for integrating different types of serial equipment.
The module works within the Siemens ET 200SP distributed I/O architecture, allowing serial devices to exchange information with a compatible automation controller.
The conformal coating and specified environmental characteristics make this version suitable for applications requiring additional protection compared with standard modules.
Its T1 RAIL designation and associated railway-related qualifications make it relevant to appropriately designed railway automation installations.
The compact design supports installation in distributed control cabinets where space is limited.
It is a SIPLUS ET 200SP CM PTP T1 RAIL serial communication module. It provides RS-232, RS-422, and RS-485 communication interfaces for compatible industrial equipment.
The module supports Freeport, 3964(R), USS, and Modbus RTU master and slave communication.
The specified maximum transmission rate is 115.2 kbit/s. The actual rate depends on the protocol and connected equipment.
It uses a nominal 24 V DC supply. The permissible voltage range is 19.2–28.8 V DC.
The 6AG2137-6AA00-1BA0 is the SIPLUS version based on the standard module. It includes conformal coating and an enhanced environmental specification for more demanding operating conditions.
Yes, it supports USS communication, which can be used with compatible Siemens drives. The drive must support the protocol, and the communication parameters must be configured correctly.
The T1 RAIL version is designed for railway-related applications and has specified railway qualifications. The complete system must still meet the applicable project and installation requirements.
The module is specified for a Siemens ET 200SP Type A0 BaseUnit. Verify the exact BaseUnit and station arrangement before installation.
This model is discontinued. Siemens identifies 6AG2137-6AA01-4BA0 as its successor. Availability of the original model depends on remaining stock and the industrial spare-parts market.
Not automatically. Compare communication capabilities, environmental ratings, firmware, BaseUnit requirements, and PLC configuration before using the successor in an existing installation.
When purchasing the Siemens 6AG2137-6AA00-1BA0, verify the complete order number on the product label. The SIPLUS designation is important because this model has environmental characteristics that differ from the standard ET 200SP communication module.
For discontinued equipment, confirm whether the unit is new, unused surplus, refurbished, or previously installed. Request clear photographs of the product label and terminal area, and check the condition of the housing and connectors. If the module is intended for a railway installation, verify that its qualification and environmental specification meet the project requirements.
During maintenance, inspect the serial wiring, connector condition, grounding, and communication stability. Keep a record of protocol settings, device addresses, baud rates, and PLC configuration. These details can significantly reduce troubleshooting time when replacing a communication module.
For replacement projects, compare the original module with the successor before making changes. Confirm the BaseUnit, firmware, engineering configuration, serial interface, and communication protocol. A successful physical installation does not necessarily guarantee correct communication or system compatibility.
The Siemens 6AG2137-6AA00-1BA0 SIPLUS ET 200SP CM PTP T1 RAIL is a specialized serial communication module for industrial and railway-related automation applications. It supports RS-232, RS-422, and RS-485 interfaces, together with Freeport, 3964(R), USS, and Modbus RTU communication.
Its conformal coating and environmental design distinguish it from the standard ET 200SP CM PtP module. Although the original model has been discontinued, it remains relevant to maintenance and spare-parts requirements in existing installations. Accurate model identification and careful compatibility checks are essential when sourcing or replacing this module.