The Siemens 6AG2136-6DB00-1CA0 SIPLUS ET 200SP F-DQ Safety Output Module is a fail-safe digital output module designed for safety-related automation applications. It belongs to the Siemens SIPLUS ET 200SP product family and is intended for distributed I/O systems that require reliable switching of safety-related 24 V DC loads.
This module is based on the standard SIMATIC ET 200SP safety output module 6ES7136-6DB00-0CA0. The SIPLUS version incorporates conformal coating and an extended operating temperature range, making it suitable for installations exposed to more demanding environmental conditions than those typically encountered in standard control cabinets.
The 6AG2136-6DB00-1CA0 provides four fail-safe digital transistor outputs, each designed for 24 V DC applications with a maximum resistive-load switching current of 2 A. It supports safety applications up to Performance Level e according to ISO 13849 and Safety Integrity Level 3 according to IEC 61508, when used within an appropriately designed and validated safety system.
Unlike conventional digital output modules, a fail-safe output module is designed to support safety functions that place connected equipment into a defined safe state when specified fault conditions occur. Typical applications include controlled shutdown of machinery, safety-related actuator control, and emergency-stop response systems.
The module operates as part of a Siemens ET 200SP distributed I/O station. It communicates with the higher-level automation system through the station’s backplane and requires a compatible BaseUnit and safety controller configuration.
With its compact 15 mm module width, four output channels, diagnostic capabilities, and environmental protection features, the 6AG2136-6DB00-1CA0 is a specialized component for industrial safety automation.
| Parameter | Specification |
|---|---|
| Brand | Siemens |
| Product Model | 6AG2136-6DB00-1CA0 |
| Product Family | SIPLUS ET 200SP |
| Product Type | Fail-Safe Digital Output Module |
| Module Designation | F-DQ 4x24VDC HF |
| Standard Base Model | 6ES7136-6DB00-0CA0 |
| Number of Digital Outputs | 4 |
| Output Type | Transistor |
| Rated Supply Voltage | 24 V DC |
| Permissible Supply Voltage | 20.4–28.8 V DC |
| Maximum Switching Current | 2 A per output with resistive load |
| Output Configuration | PM switching |
| Safety Performance | Up to PL e, ISO 13849 |
| Safety Integrity Level | Up to SIL 3, IEC 61508 |
| Short-Circuit Protection | Yes |
| Open-Circuit Detection | Yes |
| Overload Protection | Yes |
| Diagnostic Functions | Channel and module diagnostics |
| Conformal Coating | Yes |
| Operating Temperature | -30 to +60°C |
| Temporary Temperature Capability | Up to +70°C for 10 minutes, subject to specified conditions |
| Compatible BaseUnit | BU type A0 |
| Width | 15 mm |
| Height | 73 mm |
| Depth | 58 mm |
| Dimensions Provided | 15 × 73 × 58 mm |
| Weight Provided | 0.076 kg |
| Typical Application | Safety-related digital output control |
Note: The supplied weight is 0.076 kg. Manufacturer technical documentation lists approximately 57 g for the module. Confirm whether the listed weight includes additional packaging or accessories.
The primary function of the Siemens 6AG2136-6DB00-1CA0 is to control safety-related digital outputs in a distributed automation system. It receives output commands from a configured fail-safe controller and switches connected 24 V DC loads according to the application’s safety logic.
Its operation involves several important functions.
The module provides four transistor-based digital output channels. Each channel can control a compatible 24 V DC load, such as an industrial actuator, contactor interface, or other safety-related switching device.
Unlike standard digital outputs, fail-safe outputs are designed to operate within a safety architecture. Their switching behavior is monitored and controlled according to the safety program and configured operating parameters.
When a safety condition is triggered, the system can command the relevant outputs to transition to their defined safe state.
The 6AG2136-6DB00-1CA0 uses a PM output configuration. In this arrangement, the output switching architecture uses positive-side and negative-side switching paths to support safety-related load control.
This configuration is important when selecting compatible loads and planning field wiring. Engineers must follow the manufacturer’s connection diagrams and ensure that the connected equipment is suitable for the module’s output arrangement.
The module includes electronic protection functions intended to identify abnormal output conditions.
Short-circuit and overload monitoring help protect the output channels and support fault detection. When an abnormal condition occurs, the module can provide diagnostic information to the automation system.
These functions help maintenance personnel distinguish between output-channel faults and problems elsewhere in the field circuit.
Open-circuit detection helps identify situations in which the expected electrical connection between an output and its load is interrupted.
This capability is useful in safety-related installations because a disconnected actuator or damaged field cable may prevent the intended safety action from being completed.
The diagnostic behavior depends on the configured channel parameters and the electrical characteristics of the connected load.
The module provides diagnostic information through the ET 200SP station. The controller and engineering environment can use this information to identify module conditions and support maintenance activities.
Depending on the configuration, diagnostic information may include channel faults, module errors, and other operating conditions.
The 6AG2136-6DB00-1CA0 is designed to operate within a safety-related automation architecture rather than as an independent controller.
It is typically installed in a Siemens ET 200SP distributed I/O station and connected to a compatible fail-safe controller. The controller executes the safety program, while the output module provides the physical switching interface for connected field devices.
The module can be used in safety architectures based on compatible Siemens SIMATIC fail-safe controllers.
The controller evaluates safety inputs, executes the configured safety logic, and sends output commands to the distributed safety I/O system.
This architecture allows safety functions to be distributed across a machine or production line while maintaining centralized safety-program management.
The four output channels can be used to control suitable 24 V DC devices through the appropriate safety circuit.
Possible field devices include:
The connected device must be suitable for the required safety function. A fail-safe output module alone does not make an ordinary actuator or contactor safety-rated.
The ET 200SP architecture allows I/O modules to be installed close to the machines and equipment they control.
This can reduce long field wiring runs and simplify the organization of distributed control cabinets.
The 6AG2136-6DB00-1CA0 occupies a compact 15 mm module width, making it practical for installations where cabinet space is limited.
Diagnostic information can help engineers identify output faults and investigate safety-system interruptions.
For example, if a connected actuator does not respond to a safety command, maintenance personnel can examine the channel status, field wiring, load condition, and controller diagnostics.
This structured troubleshooting approach can reduce unnecessary component replacement and help restore equipment safely.
The Siemens SIPLUS ET 200SP F-DQ module is intended for safety-related switching tasks in industrial automation. Its suitability depends on the required safety function, load characteristics, system architecture, and applicable safety standards.
Automated manufacturing lines often contain conveyors, robotic equipment, positioning devices, and powered mechanical assemblies.
The module can provide fail-safe digital output signals for compatible safety-related control circuits. When a safety condition occurs, the configured controller can command the relevant outputs to transition to their defined safe state.
Packaging machines may include motors, actuators, pneumatic systems, and moving mechanical components.
Safety-related output channels can be incorporated into machine shutdown and actuator-control arrangements. The exact implementation depends on the machine’s risk assessment and safety design.
Material-handling equipment such as conveyor systems, transfer units, and automated storage machinery may require coordinated safety shutdown functions.
The 6AG2136-6DB00-1CA0 can be used as part of a distributed safety I/O system that controls compatible field devices.
Industrial process facilities may use safety-related actuators and shutdown circuits to manage equipment during abnormal operating conditions.
The module can provide the required digital output interface where the load voltage, current, and safety architecture are compatible.
The SIPLUS product family includes environmental protection features intended for demanding industrial and transportation-related applications.
The conformal coating and extended temperature capability of this model make it relevant to installations where environmental conditions are more challenging than those in a typical indoor control cabinet.
Actual suitability for railway or other regulated applications must be checked against the relevant system approvals and project requirements.
Correct installation is essential for maintaining the module’s diagnostic and safety functions.
The 6AG2136-6DB00-1CA0 is designed for use with a compatible ET 200SP BaseUnit, with BU type A0 identified in the technical specifications.
Before installation, verify the BaseUnit type, station configuration, terminal arrangement, and compatibility with the selected safety I/O system.
Do not install the module into an arbitrary ET 200SP position without checking the system configuration.
The module uses a nominal 24 V DC supply, with a documented permissible range of 20.4–28.8 V DC.
The power supply must provide sufficient capacity for the module and connected loads. Engineers should also verify voltage drop, grounding, and the electrical characteristics of the field devices.
The four transistor outputs must be wired according to the PM output configuration and the manufacturer’s connection diagrams.
Check the rated current of each connected load. The maximum switching capacity for a resistive load is 2 A per output.
Inductive loads may require additional consideration because their electrical behavior during switching differs from that of resistive loads.
The module must be integrated into a compatible fail-safe automation project.
Engineering personnel should configure the module in the appropriate Siemens engineering environment, assign the required hardware parameters, and establish the safety communication and diagnostic settings.
The safety program must be developed and validated according to the machine’s risk assessment and applicable functional-safety standards.
Before commissioning, verify the correct response of each output channel and the connected safety-related device.
Testing should include the intended safe-state behavior, fault detection, diagnostic response, and recovery procedure.
Safety functions must be validated as part of the complete machine or process system, not simply by checking whether the output LED changes state.
The SIPLUS version includes conformal coating and an extended temperature range of -30 to +60°C under the specified operating conditions.
However, environmental protection does not remove the need for suitable cabinet design. Avoid direct exposure to liquids, excessive contamination, vibration beyond permitted limits, and other conditions outside the manufacturer’s specifications.
The 6AG2136-6DB00-1CA0 operates as part of a Siemens ET 200SP safety automation system.
| Component | Function | Integration Considerations |
|---|---|---|
| Siemens ET 200SP Interface Module | Connects the distributed I/O station to the automation network | Verify network and controller compatibility |
| Siemens SIMATIC F-CPU | Executes fail-safe control logic | Confirm supported hardware and safety firmware |
| ET 200SP BaseUnit BU type A0 | Provides the module’s mounting and electrical connection | Use the compatible BaseUnit type |
| 24 V DC Power Supply | Supplies the module and field circuits | Confirm voltage, capacity, and power distribution |
| ET 200SP F-DI Module | Acquires fail-safe digital input signals | Configure compatible safety input channels |
| ET 200SP F-DQ Module | Provides fail-safe digital output switching | Verify output architecture and load requirements |
| Safety Contactor | Disconnects or controls power to machinery | Confirm contactor ratings and safety architecture |
| Safety Relay or Safety Device | Provides additional safety-related functions where required | Integrate according to the overall risk assessment |
| STEP 7 Safety Engineering Software | Configures and programs the fail-safe controller | Use a compatible engineering version |
Component compatibility should be checked against the specific controller, firmware, engineering software, and ET 200SP station configuration.
When replacing the 6AG2136-6DB00-1CA0, engineers should compare both its electrical characteristics and its functional-safety capabilities.
| Model | Product Type | Replacement Considerations |
|---|---|---|
| 6ES7136-6DB00-0CA0 | Standard ET 200SP F-DQ 4x24VDC/2A PM module | Standard counterpart; does not automatically provide the same SIPLUS environmental configuration |
| 6AG2136-6DC00-1CA0 | SIPLUS ET 200SP F-DQ 8x24VDC/0.5A | Different channel count and output-current rating |
| 6ES7136-6DC00-0CA0 | ET 200SP F-DQ 8x24VDC/0.5A | Different output architecture and current capacity |
| 6AG2136-6BA00-1CA0 | SIPLUS ET 200SP F-DI module | Safety input function rather than safety output function |
| 6AG2136-6PA00-1BC0 | SIPLUS ET 200SP F-PM-E power module | Provides safety-related power distribution functions rather than the same four-channel output function |
The standard counterpart 6ES7136-6DB00-0CA0 may be relevant when the original module’s environmental protection features are not required. However, it should not be treated as an automatic substitute for installations that depend on the SIPLUS temperature range or conformal coating.
Before selecting a replacement, verify:
A replacement module may require engineering changes and renewed safety validation.
The module provides four safety-related transistor outputs for controlling compatible 24 V DC loads within a properly engineered safety system.
It supports applications up to PL e and SIL 3 when integrated and validated according to the applicable safety architecture and standards.
Channel and module diagnostics help maintenance personnel identify abnormal conditions and investigate output faults.
Short-circuit and overload protection support reliable operation and help detect electrical problems in connected field circuits.
The conformal coating and extended operating temperature range make the module suitable for selected installations with demanding environmental conditions.
The 15 mm module width helps reduce installation space while maintaining four fail-safe output channels.
The module can be integrated into Siemens ET 200SP distributed I/O systems, allowing safety-related outputs to be positioned closer to the equipment they control.
It is a SIPLUS ET 200SP F-DQ fail-safe digital output module designed for safety-related 24 V DC switching applications.
The module provides four digital transistor output channels.
Its rated supply voltage is 24 V DC, with a permissible range of 20.4–28.8 V DC.
The documented maximum switching capacity is 2 A per output for resistive loads. Actual load selection must follow the manufacturer’s specifications and the electrical characteristics of the connected device.
Yes. The module supports safety applications up to SIL 3 according to IEC 61508 when used within a properly designed and validated safety system.
The 6AG2136-6DB00-1CA0 is the SIPLUS version based on the standard 6ES7136-6DB00-0CA0. It includes conformal coating and an extended environmental temperature specification.
The technical data identifies BU type A0 as a usable BaseUnit. The exact station arrangement and terminal configuration should be verified before installation.
It can switch compatible 24 V DC loads, but its use in a safety function requires the complete circuit, connected devices, and controller to meet the applicable safety requirements. An ordinary actuator does not become safety-rated simply because it is connected to a fail-safe output.
The specified operating temperature range is -30 to +60°C. The module also has a temporary higher-temperature capability under defined conditions. Refer to the manufacturer’s documentation for the exact duration and installation requirements.
Confirm the full order number, module type, output channel count, voltage, current rating, BaseUnit compatibility, environmental requirements, and safety-system configuration. Also inspect the product condition and verify whether it has been tested.
When purchasing the Siemens 6AG2136-6DB00-1CA0, verify the complete order number rather than relying only on the ET 200SP or F-DQ product description. Similar-looking Siemens modules may have different output channel counts, current ratings, environmental specifications, or safety functions.
For replacement projects, compare the original module’s configuration with the proposed replacement. Pay particular attention to the four-channel PM output architecture, the 24 V DC supply, the required safety performance, and the conformal coating.
For used or surplus units, request clear photographs of the product label, front panel, and connection area. Check the module housing, contacts, and visible signs of damage. Where the module is intended for a safety-critical installation, request suitable functional test information and verify its suitability through the project’s approved engineering process.
During routine maintenance, monitor diagnostic information, inspect field wiring, and check connected loads for short circuits, overloads, or open-circuit conditions. Any replacement or modification affecting a safety function should be followed by the required verification and validation procedures.
The Siemens 6AG2136-6DB00-1CA0 SIPLUS ET 200SP F-DQ Safety Output Module is a compact four-channel fail-safe digital output module designed for 24 V DC industrial safety applications. With transistor outputs rated for up to 2 A resistive loads, diagnostic functions, short-circuit protection, conformal coating, and support for safety applications up to PL e and SIL 3, it is an important component in compatible Siemens distributed safety I/O systems.
For industrial maintenance, machine safety upgrades, and replacement projects, the complete model number and system configuration should always be checked. Correct BaseUnit selection, load compatibility, safety-program configuration, and system-level validation are essential for dependable operation.