Our advantage
Global Logistics
We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.
Brand new and original
Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.
24-hour service
We provide 7*24 hours service to our customers. We will be there whenever you need us.
Price advantage
All our products are priced very favorably because we have our own warehouse and supply.
| Company Information | |||
| [email protected] | |||
| Mobile | +8615980777398 | ||
| +8615980777398 | |||
| 15980777398 |

The Siemens 6AG1255-0AA00-2JA2 SIPLUS G120 IOP-2 Intelligent Operator Panel is an operator interface designed for commissioning, operating, monitoring, and maintaining compatible SINAMICS G120 drive systems. It provides a convenient local interface between maintenance personnel and the drive, allowing users to access operating information, adjust parameters, and perform selected drive-management tasks.
This model is based on the standard Siemens 6SL3255-0AA00-4JA2 Intelligent Operator Panel IOP-2. It belongs to the SIPLUS product range and features conformal coating intended to improve protection of its electronic assemblies in more demanding environmental conditions.
The panel is designed for an operating temperature range of -20°C to +50°C. Its coating-related specifications include protection for printed circuit board assemblies and compliance with several coating and environmental qualification requirements. This makes it relevant to industrial installations where ordinary electronic components may require additional protection against environmental influences.
The 6AG1255-0AA00-2JA2 is an operator panel rather than a standalone PLC, motor controller, or power module. Its primary purpose is to provide access to supported SINAMICS G120 drive functions. It can be used during initial commissioning, routine operation, troubleshooting, and parameter management.
The panel supports multiple languages, including German, English, French, Italian, Spanish, Portuguese, Dutch, Swedish, Russian, Czech, Polish, Turkish, Finnish, and Simplified Chinese. This multilingual capability is useful for industrial facilities with international engineering teams and operators.
With compact dimensions of 70 × 106 × 30 mm and a net weight of 0.134 kg, the unit is suitable for local drive-interface applications where installation space and convenient access are important considerations.
| Parameter | Specification |
|---|---|
| Brand | Siemens |
| Product Range | SIPLUS |
| Model | 6AG1255-0AA00-2JA2 |
| Product Type | Intelligent Operator Panel |
| Product Designation | SIPLUS G120 IOP-2 |
| Standard Base Model | 6SL3255-0AA00-4JA2 |
| Compatible Drive Family | SINAMICS G120 |
| Main Function | Drive operation, commissioning, parameterization, and diagnostics |
| Operating Temperature | -20°C to +50°C |
| Protective Feature | Conformal coating |
| PCB Coating Standard | EN 61086, Class 2 |
| Protection Against Fouling | EN 60664-3, Type 1 |
| Railway Electronic Equipment Coating | EN 50155:2017, Class PC2 |
| Additional Coating Qualification | IPC-CC-830A, Class A |
| Supported Languages | German, English, French, Italian, Spanish, Portuguese, Dutch, Swedish, Russian, Czech, Polish, Turkish, Finnish, Simplified Chinese |
| Dimensions | 70 × 106 × 30 mm |
| Weight | 0.134 kg |
| Typical Application | Local operation and maintenance of SINAMICS G120 drives |
Note: The conformal coating specifications describe protection of the electronic assemblies. They should not be interpreted as a complete enclosure IP rating or as permission to expose the panel to unrestricted moisture or chemical contamination.
The 6AG1255-0AA00-2JA2 provides a local operator interface for compatible SINAMICS G120 drives. It allows personnel to interact with the drive’s supported functions without relying exclusively on an external engineering computer or supervisory system.
One of the main functions of the IOP-2 is to provide access to drive parameters.
During commissioning, engineers need to configure settings that determine how a drive responds to commands and controls its connected motor. Depending on the supported drive configuration, the operator panel can assist with parameter entry and adjustment.
Typical commissioning tasks may include:
Correct parameterization is essential for stable motor operation. Settings must correspond to the connected motor, mechanical load, and application requirements.
The IOP-2 provides an operator interface for supported local drive-control functions. It helps maintenance personnel access drive information and perform permitted operating tasks directly at the equipment.
This is particularly useful when a drive is installed inside an industrial cabinet or machine enclosure and local access is required during commissioning or troubleshooting.
The functions available depend on the connected SINAMICS drive, its firmware, and the configuration of the control system.
The operator panel allows users to review available drive information and operating conditions.
During normal operation, maintenance personnel may need to check whether the drive is operating correctly, review parameter values, or identify abnormal conditions. Local access to this information can reduce the time required for preliminary troubleshooting.
The IOP-2 is an interface device. It does not independently perform the power conversion or motor-control functions of the drive itself.
When a drive reports an alarm or fault, maintenance personnel need to identify the cause before restarting the equipment.
The IOP-2 can assist by providing access to supported diagnostic information. Depending on the connected drive, users can review fault messages and related operating information to guide troubleshooting.
Typical investigation areas include:
The actual diagnostic information depends on the connected drive and its supported functions.
The IOP-2 family supports drive-setting backup and transfer functions for compatible equipment. These functions can help maintenance teams preserve configuration information and simplify replacement or commissioning activities.
Before transferring parameters, verify compatibility between the source and target drive, including hardware configuration, firmware, and application requirements. Parameter transfer should not replace a complete commissioning inspection.
The Siemens 6AG1255-0AA00-2JA2 is designed to support local interaction with compatible SINAMICS G120 drive systems. Its role is different from that of a power module, control unit, or PLC.
In an industrial drive installation, operators and maintenance engineers need a way to access drive information. The IOP-2 provides this local interface and helps users perform supported tasks at the drive.
It can be particularly useful during initial startup, equipment adjustment, and maintenance inspections.
Commissioning involves checking electrical connections, configuring motor data, setting control parameters, and testing the complete drive installation.
The IOP-2 helps engineers access supported drive settings and operating functions during this process. This can simplify work at installations where the drive is not continuously connected to a dedicated engineering workstation.
During maintenance, the operator panel provides a local point of access for checking drive information and investigating alarms.
This can help technicians distinguish between drive-related issues, motor problems, and faults originating elsewhere in the machine-control system.
A SINAMICS G120 drive may be incorporated into a larger automation system containing PLCs, HMIs, industrial networks, sensors, and actuators.
The IOP-2 serves as a local drive interface within this arrangement. It does not replace the PLC or the main supervisory HMI, and it should not be treated as an independent industrial communication controller.
The 6AG1255-0AA00-2JA2 can be used wherever compatible SINAMICS G120 drives require local commissioning, operation, or maintenance access.
Manufacturing facilities use variable frequency drives to control motors in production equipment, conveyors, pumps, fans, and other machinery.
The IOP-2 can help technicians configure and inspect the associated drive. Its local interface is useful when operating parameters need to be reviewed during machine setup or maintenance.
Conveyors and material-handling equipment often rely on variable-speed motor control to coordinate the movement of products.
Where SINAMICS G120 drives are installed, the IOP-2 can provide local access for drive configuration and diagnostics. This can support maintenance work when conveyor speed or motor behavior needs investigation.
Industrial and infrastructure pumping systems may use variable frequency drives to regulate motor speed according to process demand.
The operator panel can assist technicians with local drive setup and fault investigation. Pump protection, process interlocks, and pressure-control logic remain responsibilities of the complete control system.
Fans and ventilation equipment commonly use variable-speed drives to regulate airflow.
The IOP-2 can support local commissioning and maintenance of compatible G120 drive installations. Its extended temperature range may also be relevant to installations exposed to a wider range of ambient temperatures, provided all equipment environmental limits are respected.
Industrial process facilities use drives to operate motors in auxiliary and production equipment. Maintenance teams need reliable access to drive settings and diagnostic information.
The SIPLUS version may be considered where additional protection for electronic assemblies is required. Its coating specifications should be assessed against the actual environmental conditions rather than assumed to provide universal chemical or moisture resistance.
Some infrastructure installations operate in environments with wider temperature variations or additional environmental stresses.
The SIPLUS IOP-2’s coating characteristics and specified temperature range may make it suitable for selected installations. The exact suitability must be confirmed against the environmental and regulatory requirements of the complete system.
Correct installation ensures that the operator panel can communicate with the compatible drive and provide reliable access to its supported functions.
Before installation, confirm that the connected equipment belongs to a supported SINAMICS G120 configuration.
The 6AG1255-0AA00-2JA2 is based on the standard 6SL3255-0AA00-4JA2 IOP-2. However, compatibility should still be checked against the specific drive model, control unit, firmware, and applicable operating instructions.
Do not assume that every Siemens drive supports this operator panel.
The panel has supplied dimensions of 70 × 106 × 30 mm. Confirm the actual mounting arrangement and required clearance before installation.
If the panel is installed directly on the drive, follow the applicable mounting instructions. If a door-mounted arrangement is required, use the appropriate mounting accessories specified for the supported configuration.
The operator panel must be connected using the interface and mounting arrangement supported by the SINAMICS G120 equipment.
Before connection, isolate the equipment as required by the manufacturer’s instructions. Inspect the connector and mounting area for damage, contamination, or loose components.
Avoid forcing the panel into place or using an incompatible accessory.
After installation, check that the panel is recognized by the drive and that the expected operating interface is available.
Review the drive configuration and confirm that the motor and application parameters are correct. Test the supported local operating and diagnostic functions before returning the equipment to service.
The SIPLUS version is specified for operation from -20°C to +50°C and includes conformal coating.
The coating provides additional protection for electronic assemblies, but the installation must still meet the equipment’s environmental limits. Avoid exposure to conditions beyond the specified temperature range or to contaminants for which the coating has not been qualified.
During commissioning or maintenance, record relevant drive parameters and configuration details. This information can help technicians investigate future faults and support replacement work.
Where parameter backup or transfer is used, verify that the target drive is compatible before applying the saved configuration.
The 6AG1255-0AA00-2JA2 is an operator interface for supported SINAMICS G120 drive installations. The following components may form part of the same system.
| Component | Function | Integration Considerations |
|---|---|---|
| SINAMICS G120 Control Unit | Manages drive control and communication functions | Confirm exact compatibility and firmware |
| SINAMICS G120 Power Module | Provides power conversion for the connected motor | Select according to motor and application ratings |
| AC Motor | Converts electrical energy into mechanical movement | Verify motor voltage, current, and power |
| PLC | Coordinates machine and process logic | Integrate through the supported drive-control interface |
| Main HMI | Provides centralized operator supervision | The IOP-2 complements rather than replaces the main HMI |
| Drive Communication Network | Exchanges data between the drive and automation system | Confirm the installed communication option |
| Operator Panel Mounting Accessories | Support the required installation arrangement | Use accessories approved for the panel and drive |
| Engineering Software | Supports drive configuration and commissioning | Use the appropriate Siemens engineering tools and versions |
The components listed are examples of equipment that may be used in a SINAMICS G120 installation. They are not necessarily included with the operator panel.
When replacing the 6AG1255-0AA00-2JA2, it is important to distinguish between the SIPLUS version and the standard IOP-2.
| Model | Description | Replacement Considerations |
|---|---|---|
| 6AG1255-0AA00-2JA2 | SIPLUS G120 IOP-2 with conformal coating | Original model for installations requiring the SIPLUS environmental configuration |
| 6SL3255-0AA00-4JA2 | Standard SINAMICS G120 IOP-2 | Base model; environmental protection and operating-temperature specifications differ |
| 6SL3255-0AA00-4CA1 | SINAMICS G120 Basic Operator Panel BOP-2 | Different operator interface and functionality; not a direct equivalent |
| 6SL3255-0AA00-4HA1 | SINAMICS G120 IOP-2 Handheld | Handheld version with a different physical arrangement |
| 6SL3256-0AP00-0JA0 | Operator panel door-mounting kit | Installation accessory rather than an operator panel |
Before selecting a replacement, compare:
The standard 6SL3255-0AA00-4JA2 is the base model for the SIPLUS version, but it should not automatically be considered an equivalent replacement in environments where the additional coating and extended temperature range are required.
The specified operating temperature range of -20°C to +50°C provides flexibility for selected industrial installations with wider ambient temperature variations.
The SIPLUS version includes conformal coating for its electronic assemblies. This adds a level of protection against environmental influences under the conditions covered by the applicable coating specifications.
The panel provides a local interface for supported SINAMICS G120 commissioning, parameterization, operation, and diagnostics.
Support for multiple European and Asian languages, including Simplified Chinese, makes the panel suitable for international engineering and maintenance teams.
Its 70 × 106 × 30 mm dimensions and 0.134 kg net weight make it suitable for compact drive-interface installations.
Access to supported drive parameters and diagnostic information can help technicians perform commissioning and troubleshooting tasks more efficiently.
The SIPLUS design is intended for applications where additional environmental protection is needed compared with the corresponding standard product.
It is the SIPLUS G120 IOP-2 Intelligent Operator Panel, designed for local operation, commissioning, parameterization, and diagnostics of compatible SINAMICS G120 drives.
No. It is an operator interface panel. It provides access to supported drive functions but does not independently perform PLC logic or motor power conversion.
Its base model is Siemens 6SL3255-0AA00-4JA2, the standard SINAMICS G120 IOP-2 Intelligent Operator Panel.
The specified operating temperature range is -20°C to +50°C.
Yes. The SIPLUS version includes conformal coating for its electronic assemblies. Its published coating specifications include EN 61086 Class 2 and IPC-CC-830A Class A requirements.
It is designed for compatible SINAMICS G120 drive systems. The exact drive model and firmware should be checked before installation.
Supported languages include German, English, French, Italian, Spanish, Portuguese, Dutch, Swedish, Russian, Czech, Polish, Turkish, Finnish, and Simplified Chinese.
Yes. It provides access to supported diagnostic information and operating data. The specific diagnostic functions depend on the connected drive and its configuration.
It may provide similar operator functions, but it does not automatically provide the same SIPLUS environmental configuration. Check temperature and coating requirements before substitution.
The supplied and manufacturer-listed dimensions are 70 × 106 × 30 mm. The net weight without packaging is 0.134 kg.
When purchasing the Siemens 6AG1255-0AA00-2JA2, verify the complete order number and confirm that the product is the SIPLUS G120 IOP-2 version rather than the standard 6SL3255-0AA00-4JA2.
For replacement projects, check the connected SINAMICS G120 drive model, firmware compatibility, mounting arrangement, and required operator functions. If the installation depends on the SIPLUS environmental protection, do not substitute the standard panel without evaluating the operating environment.
For new or surplus equipment, request clear photographs of the product label and physical connectors. Confirm the product condition, packaging, included accessories, and warranty terms. Keep the supplied dimensions and net weight separate from shipping-package measurements.
During maintenance, inspect the panel and connector for physical damage, contamination, and signs of deterioration. Follow the manufacturer’s handling and installation instructions, and avoid cleaning methods or chemicals that may damage the housing or protective coating.
Where the operator panel is used for parameter backup or transfer, keep a record of the original drive configuration. Before restoring parameters to another drive, verify hardware and firmware compatibility and carry out the required commissioning checks.
The Siemens 6AG1255-0AA00-2JA2 SIPLUS G120 IOP-2 Intelligent Operator Panel is a specialized operator interface for compatible SINAMICS G120 drive systems. Based on the standard 6SL3255-0AA00-4JA2 IOP-2, it adds conformal coating and supports an operating temperature range of -20°C to +50°C.
Its main functions include local drive operation, commissioning support, parameterization, and diagnostics. With multilingual support, compact dimensions, and additional environmental protection for electronic assemblies, it is suitable for selected industrial installations requiring convenient local access to SINAMICS G120 drives.
For procurement and replacement, the complete model number, connected drive compatibility, environmental requirements, and mounting arrangement should always be checked before installation.