• Schneider TSXWMY100 Ethernet TCP/IP Module
  • Schneider TSXWMY100 Ethernet TCP/IP Module
  • Schneider TSXWMY100 Ethernet TCP/IP Module
  • Schneider TSXWMY100 Ethernet TCP/IP Module
Product Overview The Schneider Electric TSXWMY100 Ethernet TCP/IP Module is an industrial communication module designed for the Modicon Premium automation platform. It provides Ethernet connectivity bet……
Schneider TSXWMY100 Ethernet TCP/IP Module
  • Schneider
  • TSXWMY100
  • Ethernet TCP/IP Module
  • France
  • 260×180×60 mm
  • 0.44 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 7

Our advantage

Schneider TSXWMY100 Ethernet TCP/IP Module

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Schneider TSXWMY100 Ethernet TCP/IP Module

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Schneider TSXWMY100 Ethernet TCP/IP Module

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Schneider TSXWMY100 Ethernet TCP/IP Module

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Schneider Electric TSXWMY100 Ethernet TCP/IP Module is an industrial communication module designed for the Modicon Premium automation platform. It provides Ethernet connectivity between a Premium PLC system and other devices on an industrial network, allowing controllers, engineering workstations, supervisory systems, and compatible network equipment to exchange data.

As industrial automation systems become increasingly connected, communication modules play an important role in linking PLC hardware with plant-level networks. The TSXWMY100 provides a 10/100 Mbit/s Ethernet interface and supports industrial communication services including Modbus TCP and Uni-TE messaging. It also provides web server functionality, SNMP support, and other network-related services.

The module uses an RJ45 physical interface for connection to a copper Ethernet network. Its transmission speed can operate at 10 or 100 Mbit/s, depending on the network configuration and connected equipment. The module receives its power through the Modicon Premium rack rather than requiring a separate external power supply.

One of the main characteristics of the TSXWMY100 is its Transparent Ready Class D10 web server capability. This functionality allows authorized users to access supported diagnostic and data-viewing features through a web browser. The module also supports FactoryCast-related web functions, including configurable web pages and HMI functions, depending on the installed configuration.

The TSXWMY100 is intended for existing Modicon Premium installations. Since the product has been discontinued, maintenance teams should verify the complete model number, PLC platform compatibility, firmware requirements, and availability of replacement hardware before purchasing.

Technical Specifications

Parameter Specification
Brand Schneider Electric
Model TSXWMY100
Product Series Modicon Premium
Product Type Ethernet TCP/IP Communication Module
Network Interface RJ45
Ethernet Standard 10BASE-T / 100BASE-TX
Transmission Rate 10/100 Mbit/s
Supported Messaging Modbus TCP, Uni-TE
Network Services SNMP agent, web server
Web Server Class Transparent Ready Class D10
Maximum Connections 64
User Web Page Memory 8 MB
Power Supply Through the PLC rack
Current Consumption 360 mA at 5 V DC
Module Format Standard
PLC Software Compatibility PL7 Pro, Unity Pro
Local Diagnostics COL, STS, RUN, ERR, TX, RX LEDs
Dimensions Provided 260 × 180 × 60 mm
Weight Provided 0.44 kg
Manufacturer Listed Net Weight Approximately 0.34 kg
Product Lifecycle Discontinued
Main Application Ethernet communication for Modicon Premium PLC systems

Note: The supplied dimensions and weight are listing parameters. Published product information lists a net weight of approximately 0.34 kg. Confirm whether the supplied 0.44 kg represents the packaged weight or a different measurement before finalizing the product listing.

Function and Working Principle

The TSXWMY100 operates as an Ethernet communication interface within a Modicon Premium PLC system. It connects the controller platform to an Ethernet network and enables supported devices and software applications to exchange information.

1. Ethernet Network Communication

The module provides an RJ45 interface supporting 10BASE-T and 100BASE-TX Ethernet connections. It can communicate over compatible copper Ethernet cabling and supports automatic operation at the available network speed.

This allows a Modicon Premium PLC to participate in an industrial Ethernet architecture. The network can connect the PLC with engineering computers, supervisory systems, operator interfaces, and other compatible devices.

The actual communication performance depends on the connected network equipment, cable quality, network traffic, and system configuration.

2. Modbus TCP Messaging

Modbus TCP is one of the principal communication services supported by the TSXWMY100.

It allows compatible industrial devices to exchange structured data over an Ethernet network. For example, a PLC application may use Modbus TCP messaging to exchange process values or status information with another controller or supervisory device.

This is useful in installations where different automation devices need a common communication method. Correct IP addressing, device configuration, and data mapping are essential for reliable communication.

3. Uni-TE Communication

The module also supports Uni-TE messaging over TCP/IP. Uni-TE is associated with Schneider Electric’s legacy automation communication architecture.

This capability is relevant to existing Premium installations that use Schneider Electric engineering and communication tools. It helps maintain communication between supported system components without requiring every device to use the same application-level interface.

4. Embedded Web Server

The TSXWMY100 provides Transparent Ready Class D10 web server functionality.

This feature allows users to access supported information through a web browser. Depending on the configuration, available functions include:

  • Rack viewing.
  • Data Editor access through a PC terminal.
  • Configurable FactoryCast web pages.
  • FactoryCast HMI functionality.
  • Supported PLC and communication diagnostics.

The web server can provide a convenient way to review selected system information without relying exclusively on a dedicated operator interface.

Access permissions and network security should be configured appropriately, particularly when the PLC network is connected to a wider enterprise environment.

5. SNMP Network Management

The module supports an SNMP agent for network-management applications.

SNMP can help network administrators monitor compatible network devices and communication conditions through centralized management software. This is useful in larger automation installations where Ethernet infrastructure is shared by multiple PLCs and industrial devices.

6. Local LED Diagnostics

The front panel includes status indicators that help technicians identify communication and configuration conditions.

LED Indicator Function
COL Collision detection
STS Configuration status
RUN Ethernet network status
ERR Ethernet port fault
TX Data transmission activity
RX Data reception activity

These indicators provide a first level of troubleshooting information. Detailed fault diagnosis should also consider PLC configuration, Ethernet switch status, IP settings, cable condition, and application-level communication.

Role in Industrial Control Systems

The TSXWMY100 provides the network connection required to integrate a Modicon Premium PLC into an Ethernet-based industrial control architecture.

PLC Network Connectivity

A PLC may control production equipment locally while exchanging information with other systems through Ethernet. The TSXWMY100 provides the communication interface for this network connection.

This allows a Premium controller to participate in a broader automation environment involving operator stations, engineering computers, and compatible industrial devices.

SCADA and Supervisory Communication

Supervisory Control and Data Acquisition systems are used to monitor production processes and collect operating information from PLCs.

With an appropriate network and application configuration, the TSXWMY100 can support communication between a Modicon Premium installation and compatible supervisory software.

Process variables, machine status, and selected diagnostic information can be made available to higher-level systems through supported communication services.

Engineering and Maintenance Access

Engineering computers are often connected to PLC networks for application development, diagnostics, and maintenance.

The TSXWMY100 supports the network communication environment used by compatible Schneider Electric engineering tools. Product documentation identifies compatibility with PL7 Pro and Unity Pro.

Engineers should verify the exact software version, PLC CPU, firmware, and project configuration before connecting to an existing installation.

Industrial Ethernet Architecture

The module can serve as part of a structured industrial network that links control equipment with other automation devices.

Network segmentation, appropriate switching equipment, IP address management, and access controls are important for maintaining stable communication and protecting the control system.

Industrial Applications

The TSXWMY100 is intended for Modicon Premium PLC installations where Ethernet communication is required. Its applications are generally associated with existing industrial automation systems and legacy control infrastructure.

1. Manufacturing Automation

Manufacturing facilities often use PLCs to coordinate conveyors, assembly equipment, production machinery, and process stations.

The TSXWMY100 can connect a Premium PLC to an Ethernet network, supporting communication with compatible engineering and supervisory equipment.

This allows selected machine information to be exchanged across the plant’s automation architecture.

2. Process Control Systems

Industrial process-control installations may use PLCs to monitor pumps, valves, motors, and other equipment.

Ethernet communication through the TSXWMY100 can support data exchange between the Premium PLC and compatible monitoring systems.

The communication design must account for network reliability, data update requirements, and the consequences of communication loss.

3. Water and Wastewater Treatment

Water treatment facilities use PLC-based control systems to manage pumps, filtration equipment, chemical dosing systems, and treatment processes.

In existing Modicon Premium installations, the TSXWMY100 may provide Ethernet connectivity for supervisory monitoring and engineering access.

Appropriate network security and system availability planning are especially important in infrastructure applications.

4. Packaging and Material Handling

Packaging lines and material-handling systems frequently contain multiple PLC-controlled machines.

The TSXWMY100 can support Ethernet communication between a Premium PLC and compatible network devices, helping integrate machine-level information into a larger production system.

Application design should consider communication timing and the availability of alternative control paths for critical operations.

5. Energy and Utility Facilities

Utility and energy-related installations use automation systems to monitor equipment and coordinate operating conditions.

The TSXWMY100 may be used in legacy Premium PLC systems that exchange data with compatible supervisory or engineering platforms.

Its suitability depends on the communication requirements, existing PLC architecture, and lifecycle requirements of the facility.

Installation and System Integration

Correct installation and configuration are essential for reliable Ethernet communication.

1. Verify Modicon Premium Compatibility

Before installing the TSXWMY100, confirm that the PLC rack, processor, firmware, and software configuration support the module.

The TSXWMY100 is designed for the Modicon Premium platform. It should not be treated as a universal Ethernet interface for unrelated PLC families.

Check the system documentation to identify the correct rack position and any hardware or software restrictions.

2. Install the Module in the Rack

The module receives its operating power through the PLC rack.

Before installation, isolate the equipment according to the applicable maintenance procedure. Follow the manufacturer’s instructions for module insertion, rack positioning, and handling.

Avoid touching exposed electronic contacts and use appropriate electrostatic-discharge precautions.

3. Connect the Ethernet Cable

Use a compatible Ethernet cable with an RJ45 connector and connect it to the module’s Ethernet port.

The network cable should be routed away from high-interference power conductors where appropriate. Use suitable cable management and grounding practices for the installation environment.

Inspect the connector and cable for physical damage before commissioning.

4. Configure Network Parameters

Configure the module’s network settings according to the existing industrial Ethernet architecture.

Important settings may include:

  • IP address.
  • Subnet mask.
  • Gateway configuration, where applicable.
  • Network communication parameters.
  • Device addressing and application-level data mapping.

Avoid duplicate IP addresses and document the final configuration for future maintenance.

5. Configure PLC Communication Services

Use the appropriate Schneider Electric engineering software and system documentation to configure the required communication services.

Confirm that the selected application uses supported services such as Modbus TCP or Uni-TE messaging.

Do not assume that every Ethernet service available on other Premium communication modules is also available on the TSXWMY100. In particular, its feature set differs from certain TSX ETY modules.

6. Test Communication

After installation, verify that the module starts correctly and that the status indicators show the expected operating conditions.

Test the Ethernet connection, PLC communication, web server access, and any required Modbus TCP or Uni-TE messaging.

Check the network switch, cable, IP configuration, and PLC application if communication is unsuccessful.

Compatible System Components

The TSXWMY100 operates within a Modicon Premium automation environment. The following components may be relevant to a complete installation.

Component Function Integration Considerations
Modicon Premium PLC rack Houses the controller and communication modules Verify supported rack configuration and module position
Premium CPU Executes PLC application logic Confirm processor compatibility and firmware
Rack power supply Supplies operating power to installed modules Verify available power capacity
Ethernet switch Connects PLC equipment to the industrial network Use a suitable industrial Ethernet switch
RJ45 Ethernet cable Provides the physical network connection Confirm cable category, length, and environmental suitability
Engineering workstation Supports PLC configuration and diagnostics Verify PL7 Pro or Unity Pro compatibility
SCADA system Provides supervisory monitoring Configure supported communication services and data mapping
HMI system Provides operator information and control Confirm the selected communication architecture
Network management software Monitors network equipment Use supported SNMP functions where required

These components are examples of equipment used in a compatible automation architecture. They are not necessarily included with the TSXWMY100.

Alternative Models and Replacement Considerations

The TSXWMY100 has been discontinued. Schneider Electric regional product information has referenced different replacement guidance, so replacement selection should be based on the actual control platform and application rather than a model-number comparison alone.

Alternative or Related Module Platform / Role Considerations
Schneider Electric BMENOC0311 Modicon M580 Ethernet communication module A potential migration option in some Schneider guidance; requires an M580-based architecture
Schneider Electric TSXETY4103 Modicon Premium Ethernet communication module Related Premium communication product, but feature differences must be checked
Schneider Electric TSXETY5103 Modicon Premium Ethernet communication module Offers a different communication feature set; not automatically interchangeable
Schneider Electric TSXWMY100 Original Modicon Premium module Suitable for like-for-like maintenance only when the exact hardware and configuration are verified

Before choosing a replacement, evaluate:

  • PLC platform and CPU compatibility.
  • Rack and slot requirements.
  • Ethernet speed and physical interface.
  • Modbus TCP and Uni-TE communication requirements.
  • Web server functionality.
  • Supported connection capacity.
  • PLC programming software and firmware.
  • Existing SCADA and HMI configuration.
  • Network addressing and security requirements.
  • Application downtime and commissioning requirements.

A migration from Modicon Premium to Modicon M580 may involve hardware replacement, application conversion, communication changes, and engineering work. BMENOC0311 should not be considered a direct plug-in substitute for TSXWMY100.

Key Advantages

10/100 Mbit/s Ethernet Connectivity

The module provides an Ethernet interface supporting 10BASE-T and 100BASE-TX, allowing compatible Premium PLC installations to connect to industrial Ethernet networks.

Modbus TCP and Uni-TE Support

Support for these communication services helps integrate the module into existing Schneider Electric and compatible industrial communication architectures.

Embedded Web Server

Transparent Ready Class D10 web server functionality provides access to supported monitoring and diagnostic features.

SNMP Support

The SNMP agent can assist network-management applications in monitoring compatible network infrastructure.

Rack-Based Power Supply

The module receives power through the Modicon Premium rack, avoiding the need for a separate external power supply.

Local Status Indicators

The COL, STS, RUN, ERR, TX, and RX LEDs provide useful diagnostic information during installation and troubleshooting.

Support for Legacy Premium Systems

For facilities maintaining existing Modicon Premium installations, the TSXWMY100 can be an important spare part for restoring Ethernet communication functionality.

Technical FAQs

1. What is the Schneider Electric TSXWMY100?

The TSXWMY100 is an Ethernet TCP/IP communication module designed for the Modicon Premium automation platform. It provides network connectivity through an RJ45 interface.

2. What Ethernet speed does the TSXWMY100 support?

It supports 10BASE-T and 100BASE-TX Ethernet, with transmission rates of 10 or 100 Mbit/s.

3. Which communication protocols does it support?

The module supports Modbus TCP and Uni-TE messaging over TCP/IP. It also provides SNMP agent and web server functionality.

4. Does the TSXWMY100 have a built-in web server?

Yes. It provides Transparent Ready Class D10 web server functionality, including supported rack-viewing, data-editor, and FactoryCast-related features.

5. How is the module powered?

The TSXWMY100 receives its power through the Modicon Premium rack. Its documented current consumption is 360 mA at 5 V DC.

6. Which PLC programming software is compatible?

Product documentation identifies PL7 Pro and Unity Pro compatibility. The exact software version and supported PLC configuration should be verified before use.

7. How many network connections can it support?

The published product specifications list a maximum of 64 connections. Actual application performance depends on the communication configuration and network environment.

8. Is the TSXWMY100 discontinued?

Yes. Schneider Electric lists the TSXWMY100 as discontinued. Service and support dates may vary by region, so check the applicable local product lifecycle information.

9. Can BMENOC0311 directly replace the TSXWMY100?

No. BMENOC0311 belongs to the Modicon M580 platform and is not a direct plug-in replacement for a Modicon Premium module. A platform migration and engineering assessment may be necessary.

10. What should be checked before purchasing a replacement module?

Verify the complete model number, physical condition, Ethernet port, status indicators, PLC compatibility, and available test information. Also confirm whether the module has been configured or used previously and whether it is supplied with any accessories.

Procurement and Maintenance Recommendations

When sourcing the Schneider Electric TSXWMY100, begin by checking the model number printed on the module. This is particularly important for discontinued industrial automation components, where similar-looking communication modules may belong to different PLC platforms or provide different network services.

For used or refurbished units, request clear photographs of the front panel, product label, RJ45 connector, and module contacts. Confirm the condition of the housing and connectors, and ask whether the unit has been functionally tested.

Before installing a replacement, record the existing IP configuration and communication settings. Keep a copy of the PLC application and document the network architecture so that the replacement can be commissioned consistently.

During routine maintenance, inspect the Ethernet cable, connector, rack contacts, and status indicators. Investigate unexpected ERR or RUN conditions by checking both the module and the surrounding network infrastructure.

Because the TSXWMY100 is discontinued, facilities should also evaluate long-term spare-parts availability and consider a planned migration strategy where the existing Modicon Premium platform is approaching the end of its operational lifecycle.

Conclusion

The Schneider Electric TSXWMY100 Ethernet TCP/IP Module is a communication component for the Modicon Premium automation platform. It provides 10/100 Mbit/s Ethernet connectivity through an RJ45 interface and supports Modbus TCP, Uni-TE, SNMP, and Transparent Ready Class D10 web server functionality.

With rack-based power, local diagnostic LEDs, and compatibility with the PL7 Pro and Unity Pro engineering environment, the module supports Ethernet integration in existing Premium PLC installations.

Since the TSXWMY100 has been discontinued, accurate identification and compatibility checks are essential when purchasing replacement equipment. Maintenance teams should verify the module’s condition, network configuration, and PLC platform requirements before installation.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501