• Schneider TM2AMO1HT Modicon M238 Analog Output Module
  • Schneider TM2AMO1HT Modicon M238 Analog Output Module
  • Schneider TM2AMO1HT Modicon M238 Analog Output Module
  • Schneider TM2AMO1HT Modicon M238 Analog Output Module
Product Overview The Schneider Electric TM2AMO1HT is a single-channel analog output expansion module for the Modicon M238 logic controller. It converts digital output values generated by the PLC program……
Schneider TM2AMO1HT Modicon M238 Analog Output Module
  • Schneider
  • TM2AMO1HT
  • Analog Output Module
  • France
  • 90 × 23.5 × 70 mm
  • 0.085 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 5

Our advantage

Schneider TM2AMO1HT Modicon M238 Analog Output Module

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Schneider TM2AMO1HT Modicon M238 Analog Output Module

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Schneider TM2AMO1HT Modicon M238 Analog Output Module

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Schneider TM2AMO1HT Modicon M238 Analog Output Module

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Schneider Electric TM2AMO1HT is a single-channel analog output expansion module for the Modicon M238 logic controller. It converts digital output values generated by the PLC program into proportional voltage or current signals, allowing the controller to regulate equipment that requires continuous analog references rather than simple ON/OFF commands.

The module supports two output signal formats: 0–10 V DC and 4–20 mA. With 12-bit resolution, it can generate different output levels according to the values calculated by the controller. This makes it suitable for applications involving speed references, valve positioning, pressure regulation, and other process-control functions.

For example, in a pumping system, the M238 controller can calculate the required pump speed based on pressure feedback. The TM2AMO1HT converts the programmed output value into a 0–10 V or 4–20 mA reference signal, which can then be connected to a compatible variable-frequency drive. The drive adjusts motor operation according to the received reference.

The same principle applies to modulating valves and other process actuators. Instead of simply switching an output on or off, the controller can send a continuously adjustable signal corresponding to the required operating position or setpoint.

The TM2AMO1HT has one analog output channel and uses a removable screw terminal block for field wiring. It requires an external 24 V DC supply for its analog output circuitry. Photocoupler insulation separates the output channel from the module’s internal logic, helping isolate the signal interface.

One important configuration detail is the relationship between the selected output mode and the physical wiring. The voltage and current output settings must match the connected equipment. Incorrectly configuring a channel for current output when it is physically wired for voltage operation can damage the analog circuit.

For engineers maintaining existing Modicon M238 installations, the TM2AMO1HT is a dedicated solution for adding one configurable voltage/current output without replacing the main controller.


Technical Specifications

Parameter Specification
Manufacturer Schneider Electric
Model TM2AMO1HT
Product Series Modicon M238
Product Type Analog Output Module
Number of Analog Outputs 1
Analog Output Type Voltage / Current
Voltage Output Range 0–10 V DC
Current Output Range 4–20 mA
Output Resolution 12 bits
Voltage LSB Value 2.5 mV
Current LSB Value 4.8 µA
Load Type Resistive
Voltage Load Impedance ≥ 2,000 Ω
Current Load Impedance ≤ 300 Ω
Stabilization Time 10 ms
Conversion Time 10 ms + 1 controller cycle
Measurement Error ±0.2% FS at 25°C
Temperature Coefficient ±0.015% FS/°C
Repeat Accuracy ±0.5% FS
Non-Linearity ±0.2% FS
Output Ripple ≤ 1 LSB
Total Error ±1% FS
External Supply Voltage 24 V DC
Supply Voltage Limits 19.2–30 V DC
Internal Current Consumption 50 mA at 5 V DC
External Current Consumption 40 mA at 24 V DC
Electrical Connection 1 Removable Screw Terminal Block
Signal Cable Twisted Shielded Cable
Channel Insulation Photocoupler
Dielectric Strength 500 V
Mounting Type DIN Rail / Panel Mounting
Dimensions 90 × 23.5 × 70 mm
Weight 0.085 kg

Product Features

  • Single Analog Output Channel: Provides one configurable channel for voltage or current signal generation.
  • Dual Signal Selection: Supports 0–10 V DC and 4–20 mA output modes for different actuator and drive interfaces.
  • 12-Bit Resolution: Converts controller values into finely adjustable analog output levels.
  • Low Stabilization Time: Features a 10 ms stabilization time for analog output response.
  • External 24 V DC Supply: Uses an external power source for the analog output circuitry.
  • Photocoupler Insulation: Provides electrical isolation between the output channel and internal logic.
  • Removable Screw Terminal: Simplifies field wiring, inspection, and module replacement.
  • Shielded Cable Compatibility: Supports twisted shielded wiring to help reduce electrical interference.
  • Multiple Controller Applications: Belongs to the Modicon M238 expansion system, with documented range compatibility also including Advantys OTB and Twido.
  • Adjustable Output Configuration: Allows the channel to be configured for the required voltage or current operating mode through the programming environment.

Product Working Principle

The TM2AMO1HT converts a numerical value calculated by the Modicon M238 controller into an analog electrical signal.

During normal operation, the PLC program determines the output value according to process conditions, operator settings, or feedback from connected sensors. This value is transferred to the module through the controller’s expansion interface.

The module then converts the digital command into the selected analog output format. In voltage mode, it generates a signal between 0 and 10 V DC. In current mode, it generates a signal between 4 and 20 mA.

For example, consider a variable-frequency drive controlling a centrifugal pump. The PLC program calculates the required motor speed based on the pressure measured by a transmitter. The TM2AMO1HT converts the corresponding command into a 4–20 mA reference signal, which the drive interprets as its speed demand.

The relationship between the output signal and the commanded value depends on the configured scaling. A higher output value can represent a higher speed reference, valve opening, or another process setpoint.

The module uses 12-bit conversion resolution. Its output can therefore represent multiple discrete levels across the selected analog range. The actual process response also depends on the connected equipment and its own input characteristics.

A simplified signal path is:

PLC Program → Digital Output Value → TM2AMO1HT Conversion → 0–10 V / 4–20 mA Signal → Drive or Analog Actuator

The module’s output channel is electrically isolated from the internal logic through a photocoupler. This separation helps protect the controller-side circuitry from electrical disturbances associated with the external signal interface.

Correct channel configuration is essential. The physical wiring must correspond to the selected voltage or current mode in the programming software. The connected load must also satisfy the specified impedance requirements.


Role in Schneider Electric Modicon M238 Control Architecture

Within the Modicon M238 automation architecture, the TM2AMO1HT provides an additional analog control channel for applications that require continuously adjustable output signals.

The M238 controller executes the machine or process program, while the TM2AMO1HT handles the conversion of the programmed output value into a physical analog signal. This division allows the controller to manage process logic without requiring a separate signal-conversion device for the corresponding output.

A typical arrangement in a pump-control application is:

Pressure Transmitter → Modicon M238 Controller → TM2AMO1HT → 4–20 mA Reference → Variable-Frequency Drive → Pump Motor

The module can also be used in applications involving modulating valves, proportional actuators, and other compatible analog-input equipment.

System Component Function
Schneider Electric Modicon M238 Executes machine and process control programs
Schneider Electric TM2AMO1HT Converts PLC output values into 0–10 V or 4–20 mA signals
Schneider Electric TM2AMM3HT Provides mixed analog input and output expansion
Schneider Electric TM2AMM6HT Provides additional analog input and output channels
Schneider Electric TM2AVO2HT Provides two voltage analog output channels
Schneider Electric Altivar Drive Receives compatible analog references for motor speed control
Analog Pressure Transmitter Supplies process feedback to the controller
Modulating Control Valve Adjusts fluid flow according to an analog reference
Industrial Actuator Converts the analog command into mechanical movement

The TM2AMO1HT is particularly useful when an existing M238 installation requires one additional analog control point without changing the main controller architecture.


Industrial Applications

The TM2AMO1HT is used in automation systems where PLC-generated analog signals are required to regulate equipment operation.

Industrial Application Typical Use
Pumping Systems Sending speed reference signals to variable-frequency drives
HVAC Systems Controlling compatible modulating valves and air-handling equipment
Water Treatment Adjusting chemical dosing equipment and regulating process flow
Chemical Processing Providing analog references for proportional control devices
Packaging Machinery Controlling compatible variable-speed equipment
Food and Beverage Processing Regulating pumps, valves, and process equipment
Industrial Manufacturing Providing adjustable analog commands to machine actuators
Material Handling Controlling compatible drive systems through analog references
Process Automation Converting PLC calculations into voltage or current control signals
Utility Equipment Supporting analog regulation of pumps and other process machinery

Installation and Maintenance

  1. Verify Module Compatibility: Confirm that the TM2AMO1HT matches the expansion requirements of the existing Modicon M238 installation.
  2. Prepare the Mounting Position: Select a suitable DIN rail or panel mounting location with adequate clearance for wiring and maintenance.
  3. Inspect the Module: Check the housing, terminal block, and electrical contacts for physical damage before installation.
  4. Install the Module: Secure the unit to the mounting arrangement and verify that its expansion connection is correctly engaged.
  5. Prepare the External Supply: Provide a regulated 24 V DC supply within the specified 19.2–30 V operating range.
  6. Select the Output Signal Type: Determine whether the connected equipment requires a 0–10 V voltage signal or a 4–20 mA current signal.
  7. Check Load Impedance: Verify that the voltage-mode load is at least 2,000 Ω and the current-mode load does not exceed 300 Ω.
  8. Connect Field Wiring: Use twisted shielded cable for the analog signal connection and follow the correct terminal assignments.
  9. Configure the Output Channel: Set the required signal type and output scaling in the programming environment.
  10. Verify Physical and Software Configuration: Confirm that the selected voltage or current mode matches the actual wiring before enabling the output.
  11. Test Analog Signal Operation: Measure the output with an appropriate instrument and compare the measured value with the programmed reference.
  12. Perform Routine Inspection: Check terminal tightness, cable shielding, external power stability, and signal behavior during scheduled maintenance.

During troubleshooting, incorrect signal-mode configuration should be checked before replacing the module. A mismatch between the physical wiring and software settings can damage the analog circuit. Also inspect the external 24 V DC supply and connected load impedance when the output signal is outside the expected range.


Compatible System Components

Component Function
Schneider Electric Modicon M238 Main logic controller for the TM2 expansion system
Schneider Electric TM2AMO1HT Single-channel voltage/current analog output module
Schneider Electric TM2AMM3HT Mixed analog input/output expansion module
Schneider Electric TM2AMM6HT Multi-channel analog input/output expansion module
Schneider Electric TM2AVO2HT Two-channel voltage analog output module
Schneider Electric TM2ALM3LT Low-level analog input and output expansion module
Schneider Electric Advantys OTB Compatible distributed I/O system
Schneider Electric Twido Compatible controller range listed for the module
Schneider Electric Altivar Drives Receives compatible analog speed references
Analog Control Valves Regulates process flow through analog command signals

Recommended Related Models

Model / Product Product Type Typical Application
Schneider TM2AVO2HT Modicon TM2 Analog Output Module Two-channel ±10 V voltage output applications
Schneider TM2AMM3HT Modicon TM2 Analog Mixed I/O Module Applications requiring two analog inputs and one analog output
Schneider TM2AMM6HT Modicon TM2 Analog Mixed I/O Module Applications requiring four analog inputs and two analog outputs
Schneider TM2ALM3LT Modicon TM2 Low-Level Analog Mixed I/O Module Temperature measurement and analog output applications
Schneider TM2AMI2HT Modicon TM2 Analog Input Module Two-channel analog signal acquisition
Schneider TM2ARI8HT Modicon TM2 Analog Input Module Eight-channel temperature input applications using NTC/PTC sensors

Key Advantages

  • One configurable analog output channel.
  • Selectable 0–10 V DC and 4–20 mA signals.
  • 12-bit conversion resolution.
  • 10 ms stabilization time.
  • Photocoupler insulation between output and internal logic.
  • External 24 V DC power supply.
  • Removable screw terminal connection.
  • Compatible with the Modicon M238 expansion architecture.

Technical FAQs

1. Can the TM2AMO1HT generate both voltage and current outputs simultaneously?

No. The module has one configurable analog output channel. It can operate in either 0–10 V voltage mode or 4–20 mA current mode, but it does not provide two independent outputs or simultaneous voltage and current signals.

2. What is the maximum load resistance for the 4–20 mA output?

The specified load impedance for current operation is no more than 300 Ω. The connected device and cable arrangement should remain within this limit to maintain the required output performance.

3. Why is shielded twisted-pair cable recommended for the TM2AMO1HT?

Analog signals can be affected by electromagnetic interference from motor drives, contactors, and power cables. Twisted shielded cable helps reduce induced noise and improves signal quality, particularly in industrial control cabinets with multiple electrical devices.

4. What happens if the output is configured for current mode but wired for voltage operation?

An incorrect combination of physical wiring and software configuration can damage the analog output circuit. The wiring arrangement must be checked against the selected output mode in the programming software before commissioning or changing the configuration.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501