• Schneider TM2DMM8DRT Modicon M238 Discrete I/O Module
  • Schneider TM2DMM8DRT Modicon M238 Discrete I/O Module
  • Schneider TM2DMM8DRT Modicon M238 Discrete I/O Module
  • Schneider TM2DMM8DRT Modicon M238 Discrete I/O Module
Product Overview The Schneider Electric TM2DMM8DRT is an 8-channel digital mixed I/O expansion module for the Modicon M238 logic controller. It combines four 24 V DC digital inputs and four electromecha……
Schneider TM2DMM8DRT Modicon M238 Discrete I/O Module
  • Schneider
  • TM2DMM8DRT
  • Discrete I/O Module
  • France
  • 84.6 × 27.3 × 90 mm
  • 0.0895 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 7

Our advantage

Schneider TM2DMM8DRT Modicon M238 Discrete I/O Module

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Schneider TM2DMM8DRT Modicon M238 Discrete I/O Module

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Schneider TM2DMM8DRT Modicon M238 Discrete I/O Module

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Schneider TM2DMM8DRT Modicon M238 Discrete I/O Module

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Schneider Electric TM2DMM8DRT is an 8-channel digital mixed I/O expansion module for the Modicon M238 logic controller. It combines four 24 V DC digital inputs and four electromechanical relay outputs, allowing a single module to handle both field signal acquisition and equipment switching.

The input section accepts 24 V DC signals from industrial sensors, limit switches, push buttons, and other discrete devices. It supports both sink and source wiring configurations, making it suitable for different sensor output arrangements commonly found in machine control circuits.

The output section consists of four normally open relay contacts. Each channel can switch compatible AC or DC loads, with a maximum rated current of 2 A per channel. Unlike transistor output modules, relay contacts provide electrical switching through mechanical contacts, making them suitable for applications where different load voltage types are required.

The four inputs share one input common line, while the four relay outputs share a separate output common line. These common connections are not internally connected. This separation allows the input and output circuits to be arranged according to their respective power supply and grounding requirements.

The TM2DMM8DRT uses a removable screw terminal block for field wiring. This makes it possible to connect sensors and relay-controlled equipment directly to the module without requiring a separate HE10 cable assembly.

For a compact machine controlled by a Modicon M238 PLC, the TM2DMM8DRT can handle a small group of sensor signals and corresponding relay-controlled devices within one expansion position. Typical applications include conveyor control, packaging equipment, material handling, and general-purpose machine automation.


Technical Specifications

Parameter Specification
Manufacturer Schneider Electric
Model TM2DMM8DRT
Product Series Modicon M238
Product Type Discrete I/O Module
Total I/O Points 8
Digital Input Channels 4
Digital Output Channels 4
Input Type Digital, Type 1
Rated Input Voltage 24 V DC
Input Voltage Range 20.4–28.8 V DC
Input Logic Sink / Source
Rated Input Current 7 mA
Input Impedance 3.4 kΩ
Input Response Time 4 ms (ON and OFF)
Output Type Electromechanical Relay
Relay Contact Configuration 1 NO per Channel
Rated Output Voltage 24 V DC / 240 V AC
Maximum Output Voltage 30 V DC / 264 V AC
Maximum Output Current 2 A per Channel
Maximum Current per Output Common 7 A
Number of Input Common Lines 1
Number of Output Common Lines 1
Contact Resistance ≤ 45 mΩ
Minimum Switching Load 0.1 mA at 0.1 V DC
Output Response Time ≤ 10 ms (OFF to ON); ≤ 5 ms (ON to OFF)
Mechanical Durability 20 Million Operations
Isolation Between Input and Internal Logic 500 V AC for 1 Minute
Isolation Between Output and Internal Logic 2300 V AC for 1 Minute
Isolation Between Input and Output 1500 V AC for 1 Minute
Electrical Connection 1 Removable Screw Terminal Block
Mounting Type 35 mm Symmetrical DIN Rail
Dimensions 84.6 × 27.3 × 90 mm
Weight 0.0895 kg

Product Features

  • Combined Digital I/O: Integrates four digital inputs and four relay outputs in one compact expansion module.
  • 24 V DC Input Signals: Accepts standard industrial discrete signals from compatible sensors and switching devices.
  • Sink and Source Compatibility: Supports both input wiring arrangements for different sensor configurations.
  • Four Relay Output Channels: Provides four normally open relay contacts for switching external control circuits.
  • AC and DC Switching: Supports compatible AC and DC loads within the specified contact ratings.
  • 2 A Output Current: Each relay channel supports a maximum switching current of 2 A.
  • Separate Common Connections: Provides independent input and output common terminals for flexible circuit wiring.
  • Removable Screw Terminal: Allows direct field connections and simplifies wiring inspection and maintenance.
  • Electrical Isolation: Provides isolation between input circuits, output circuits, and internal logic according to the specified ratings.
  • DIN Rail Mounting: Supports installation in industrial control cabinets using a standard 35 mm symmetrical DIN rail.

Product Working Principle

The TM2DMM8DRT operates through two separate I/O sections: a digital input circuit and an electromechanical relay output circuit.

The input section receives 24 V DC signals from external field devices. When a connected sensor or switch changes state, the corresponding input circuit detects the voltage condition and transfers the signal status to the Modicon M238 controller.

The module supports both sink and source input wiring. The selected configuration depends on the electrical output characteristics of the connected sensors and the system wiring arrangement.

The output section operates through four normally open relay contacts. When the PLC program activates an output address, the corresponding relay coil is energized, causing its normally open contact to close. Current can then flow through the external load circuit.

When the controller deactivates the output, the relay coil is de-energized and the contact returns to its normally open state, interrupting the load circuit.

For example, in a conveyor system, an input channel may receive a signal from a photoelectric sensor detecting the position of a product. The M238 controller processes the signal and activates a relay output to operate an external contactor or auxiliary control circuit.

A simplified signal path is:

Field Sensors → TM2DMM8DRT Digital Inputs → Modicon M238 Controller → TM2DMM8DRT Relay Outputs → External Equipment

The relay contacts support compatible AC and DC switching applications. However, the actual switching capacity depends on the load type, voltage, current, and required electrical service life.

Inductive loads such as contactor coils and solenoid valves can generate voltage transients when switched off. Appropriate external suppression circuits should be installed to protect the relay contacts from excessive switching stress.

The input and output common connections remain electrically separate. This allows the two circuits to use their designated external connections without assuming an internal common connection between them.


Role in Schneider Electric Modicon M238 Control Architecture

Within the Modicon M238 architecture, the TM2DMM8DRT provides combined digital signal acquisition and relay-based switching.

The M238 controller executes the application program, evaluates input conditions, and determines the required output states. The TM2DMM8DRT provides the electrical interface between the controller and the connected field devices.

Its four-input and four-output configuration is suitable for compact machines that require a limited number of sensor signals and relay-controlled devices.

A typical control arrangement is:

Proximity Sensors / Limit Switches → TM2DMM8DRT Inputs → Modicon M238 Controller → TM2DMM8DRT Relay Outputs → Contactors / Solenoid Valves

System Component Function
Schneider Electric Modicon M238 Executes machine sequencing and control logic
Schneider Electric TM2DMM8DRT Provides four digital inputs and four relay outputs
Schneider Electric TM2DMM24DRF Provides 16 digital inputs and eight relay outputs
Schneider Electric TM2DRA8RT Provides eight relay output channels
Schneider Electric TM2DRA16RT Provides 16 relay output channels
Schneider Electric TM2DDI16DT Provides additional digital input channels
Proximity Sensors Detects the presence and position of machine components
Limit Switches Provides discrete position and travel-limit signals
Interface Contactors Switches external electrical equipment
Solenoid Valves Controls pneumatic and hydraulic actuators

Industrial Applications

The TM2DMM8DRT is suitable for industrial equipment requiring a combination of discrete signal monitoring and relay-controlled switching.

Industrial Application Typical Use
Packaging Machinery Monitoring product sensors and switching auxiliary equipment
Conveyor Systems Detecting product positions and controlling contactors
Assembly Lines Acquiring limit-switch signals and operating machine actuators
Material Handling Monitoring transfer positions and controlling sorting equipment
Food Processing Monitoring equipment conditions and switching auxiliary loads
Water Treatment Receiving pump status signals and controlling compatible relay circuits
Industrial Ovens Monitoring door switches and controlling auxiliary equipment
Automated Warehousing Detecting material positions and operating transfer mechanisms
Machine Tools Monitoring operating conditions and switching auxiliary devices
General Manufacturing Combining sensor acquisition and relay output control in PLC-based machines

Installation and Maintenance

  1. Verify Controller Compatibility: Confirm that the TM2DMM8DRT is supported by the installed Modicon M238 controller and the selected expansion configuration.
  2. Inspect the Module: Check the enclosure, terminal block, and expansion interface for visible damage before installation.
  3. Prepare the Mounting Position: Select a suitable control cabinet location with sufficient clearance for terminal access and field wiring.
  4. Install the Module: Secure the module to a compatible 35 mm symmetrical DIN rail and verify that the expansion connection is correctly engaged.
  5. Prepare Input Wiring: Identify the four digital input channels and determine whether the connected sensors require sink or source wiring.
  6. Connect Digital Inputs: Wire the 24 V DC sensors according to the module terminal diagram and the selected input logic configuration.
  7. Connect Relay Outputs: Connect the four normally open relay contacts to their respective external control circuits, observing the specified voltage and current limits.
  8. Check Common Connections: Verify the input and output common terminals separately. COM0 and COM1 are not internally connected.
  9. Install External Protection: Provide appropriate fuses for the relay output circuits. Do not exceed 2 A per output or 7 A for the output common line.
  10. Configure PLC Addresses: Assign the input and output channels correctly in the controller programming environment and verify the I/O mapping.
  11. Test I/O Operation: Activate each input and relay output individually during commissioning to confirm correct signal acquisition and switching.
  12. Perform Routine Inspection: Check terminal tightness, relay contact condition, external fuses, wiring insulation, and inductive-load suppression components during scheduled maintenance.

When troubleshooting, check the 24 V DC input supply and sensor wiring if an input signal is not detected. For relay output problems, inspect the external load circuit, common connection, fuse condition, and relay contact operation.


Compatible System Components

Component Function
Schneider Electric Modicon M238 Main logic controller for the expansion system
Schneider Electric TM2DMM8DRT Four-input and four-relay-output mixed I/O module
Schneider Electric TM2DMM24DRF 16-input and eight-relay-output mixed I/O module
Schneider Electric TM2DRA8RT Eight-channel relay output module
Schneider Electric TM2DRA16RT 16-channel relay output module
Schneider Electric TM2DDI16DT 16-channel digital input module
24 V DC Sensors Supply discrete signals to the input channels
Interface Contactors Switch external electrical loads
Solenoid Valves Control pneumatic and hydraulic actuators
External Suppression Devices Reduce switching transients from inductive loads

Recommended Related Models

Model / Product Product Type Typical Application
Schneider TM2DMM24DRF Modicon M238 Digital Mixed I/O Module 16 digital inputs and eight relay outputs
Schneider TM2DRA8RT Modicon TM2 Relay Output Module Eight-channel relay switching
Schneider TM2DRA16RT Modicon TM2 Relay Output Module 16-channel relay switching
Schneider TM2DDI16DT Modicon TM2 Digital Input Module 16-channel 24 V DC signal acquisition
Schneider TM2DD08UT Modicon TM2 Digital Output Module Eight-channel sinking transistor outputs
Schneider TM2DD08TT Modicon TM2 Digital Output Module Eight-channel sourcing transistor outputs

Key Advantages

  • Four digital inputs and four relay outputs in one module.
  • 24 V DC input signal compatibility.
  • Sink and source input wiring.
  • Normally open electromechanical relay contacts.
  • Supports compatible AC and DC loads.
  • Maximum 2 A switching current per output.
  • Separate input and output common connections.
  • Removable screw terminal block.
  • Electrical isolation between designated circuits.
  • Suitable for compact Modicon M238 control systems.

Technical FAQs

1. How many input and output channels does the TM2DMM8DRT provide?

The TM2DMM8DRT provides eight I/O points in total, consisting of four 24 V DC digital inputs and four electromechanical relay outputs. It is suitable for applications requiring both signal acquisition and relay switching.

2. Can the digital inputs accept both NPN and PNP sensor signals?

The input section supports both sink and source wiring configurations. This allows the module to interface with different sensor output arrangements, provided the electrical connections follow the applicable input wiring diagram.

3. What is the maximum current supported by each relay output?

Each relay output supports a maximum current of 2 A. The combined current across the output common line must not exceed 7 A. The permitted switching capacity also depends on the load type and operating voltage.

4. What precautions are required when connecting inductive loads?

Inductive loads such as contactor coils and solenoid valves can generate voltage transients when the relay contacts open. An appropriate external suppression circuit or protective device should be installed. Capacitive loads should not be connected to the relay outputs.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501