Product Overview The Schneider Electric NW20N1 MasterPact Circuit Breaker is a high-current air circuit breaker frame designed for low-voltage power distribution and electrical system protection. It bel……
Schneider NW20N1 Circuit Breaker
  • Schneider
  • NW20N1
  • Circuit Breaker
  • France
  • 352 x 537 x 297 mm
  • 65 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 4

Our advantage

Schneider NW20N1 Circuit Breaker

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Schneider NW20N1 Circuit Breaker

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Schneider NW20N1 Circuit Breaker

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Schneider NW20N1 Circuit Breaker

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Schneider Electric NW20N1 MasterPact Circuit Breaker is a high-current air circuit breaker frame designed for low-voltage power distribution and electrical system protection. It belongs to the MasterPact NW family, which is used in industrial facilities, commercial buildings, infrastructure installations, and large electrical distribution systems.

The NW20N1 is designed for applications requiring a rated current of 2000 A and a high short-circuit interruption capability. Its N1 performance classification provides a rated ultimate short-circuit breaking capacity of 42 kA at 440 V AC. The product is suitable for use in appropriately engineered power distribution systems where reliable switching, isolation, and coordination are required.

The specified configuration is a four-pole, fixed-mounted circuit breaker frame without a control unit. This distinction is important when identifying the product. The circuit breaker frame provides the mechanical and electrical platform, but the required trip or control unit must be selected separately to provide the intended protection functions.

The MasterPact NW series is designed for demanding electrical distribution environments. Its construction supports high-current connections and integration into switchboards and industrial power distribution assemblies. Depending on the selected configuration and accessories, the MasterPact platform can be used for incoming feeders, bus-tie applications, and major distribution circuits.

For maintenance teams and procurement specialists, the complete product configuration should always be verified. Pole count, mounting type, rated current, breaking capacity, trip unit, and auxiliary accessories can differ between products carrying similar MasterPact NW designations.

Technical Specifications

Parameter Specification
Brand Schneider Electric
Product Series MasterPact NW
Model NW20N1
Product Type Air Circuit Breaker Frame
Application Low-Voltage Power Distribution Protection
Rated Current 2000 A at 40°C
Number of Poles 4 Poles
Performance Classification N1
Ultimate Breaking Capacity 42 kA at 440 V AC
Rated Operational Voltage Up to 690 V AC, 50/60 Hz
Rated Insulation Voltage 1000 V AC
Rated Impulse Withstand Voltage 12 kV
Mounting Type Fixed
Control Unit Not Included
Suitability for Isolation Yes, according to IEC 60947-2
Selectivity Category Category B
Control Type Push-button
Maximum Breaking Time 25 ms
Maximum Closing Response Time 70 ms
Dimensions 352 × 537 × 297 mm
Weight 65 kg
Typical Application Main distribution, feeder protection, industrial switchboards

The specifications above describe the four-pole fixed-mounted frame configuration. The required trip unit and other accessories must be confirmed separately.

Function and Working Principle

The MasterPact NW20N1 is used in low-voltage power distribution systems to provide switching and circuit interruption capability. When correctly equipped with the appropriate control unit and accessories, the completed breaker assembly can protect electrical circuits against specified abnormal operating conditions.

1. Power Circuit Switching

The circuit breaker provides a means of connecting and disconnecting a high-current electrical circuit. Its contacts are designed for the demands of industrial power distribution, where large electrical loads and substantial current flows are common.

In a switchboard, the breaker may be installed as an incoming supply device, feeder breaker, or bus-section switching device, depending on the system design.

2. Short-Circuit Interruption

A short circuit can produce extremely high fault current within a very short period. The circuit breaker must be selected according to the prospective fault current at its installation point.

The NW20N1 N1 performance classification specifies a 42 kA ultimate breaking capacity at 440 V AC. This rating is an important selection parameter when evaluating the breaker for an electrical distribution network.

The actual protection arrangement depends on the selected trip unit, system voltage, fault level, and coordination study.

3. Overload and Fault Protection

The specified NW20N1 configuration is supplied without a control unit. Therefore, the required electronic trip unit or compatible control arrangement must be selected separately.

In a complete MasterPact installation, the trip unit monitors electrical conditions and initiates a trip when configured protection thresholds are exceeded. Depending on the selected unit, protection functions may include long-time, short-time, instantaneous, and ground-fault protection.

The specific protection functions cannot be assumed from the NW20N1 frame designation alone.

4. Four-Pole Circuit Isolation

The four-pole configuration allows switching of three phases and the neutral conductor. This arrangement may be required in electrical systems where neutral isolation is part of the protection and distribution design.

The neutral pole position and connection arrangement must be verified against the actual breaker configuration and the applicable electrical standards.

5. Electrical System Selectivity

Selectivity is important in large distribution networks. It helps ensure that a fault is isolated by the breaker closest to the affected circuit, limiting unnecessary interruption of other equipment.

The NW20N1 is classified as Category B. Actual selectivity performance depends on the selected trip unit, protection settings, upstream and downstream breakers, and the electrical coordination study.

Role in Industrial Power Distribution Systems

The Schneider MasterPact NW20N1 can serve as a major switching component in industrial low-voltage distribution systems. Its 2000 A current rating makes it suitable for applications where substantial electrical loads must be managed.

Main Incoming Circuit Breaker

In a main distribution board, a high-current circuit breaker can be installed between the incoming electrical supply and the main busbar system.

It provides the switching platform for controlling the main supply connection. The complete protection arrangement must include a suitable trip unit and correctly coordinated upstream and downstream protective devices.

Feeder Circuit Protection

Industrial facilities often distribute electricity from a main switchboard to multiple production areas, motor control centers, and auxiliary distribution panels.

A MasterPact NW breaker may be used in a feeder position where its current and interruption ratings match the electrical design.

Bus Coupler Applications

Some electrical distribution systems use two incoming supplies or separate busbar sections. A bus-coupler breaker can connect or isolate these sections according to the system’s operating strategy.

The NW20N1 frame may be considered for an appropriately rated fixed-mounted arrangement, subject to the required accessories, control logic, and interlocking design.

Generator and Transformer Distribution

Large generator and transformer installations require carefully selected switching and protection equipment.

The breaker must be matched to the generator or transformer ratings, fault-current contribution, grounding arrangement, and protection coordination requirements.

Industrial Applications

1. Manufacturing Plants

Large manufacturing facilities use electrical distribution systems to supply production lines, machine centers, pumps, compressors, and auxiliary equipment.

A 2000 A MasterPact circuit breaker frame may be used in a main distribution or feeder position where the electrical design requires this current rating and breaking capacity.

2. Data Centers

Data centers require reliable electrical distribution for server rooms, cooling systems, UPS equipment, and supporting infrastructure.

High-current circuit breakers are commonly incorporated into main and secondary switchboards. The NW20N1 may be considered for suitable distribution configurations when its electrical ratings and selected protection equipment meet the installation requirements.

3. Commercial Buildings

Large commercial buildings contain electrical distribution systems supplying lighting, HVAC equipment, elevators, and other building services.

A MasterPact NW breaker may be used in main switchboards or major feeder circuits where high-current switching and protection are required.

4. Power Generation Facilities

Power generation installations require circuit breakers to manage connections between generators, transformers, busbars, and distribution equipment.

The NW20N1’s rated current and short-circuit performance should be evaluated against the generator or transformer characteristics and the calculated system fault level.

5. Water and Wastewater Treatment Plants

Water treatment facilities operate pumps, blowers, mixers, and other electrically driven equipment. Their main distribution systems may require high-capacity circuit breakers to supply multiple process areas.

A suitable MasterPact NW configuration can be incorporated into these systems as part of a coordinated electrical protection arrangement.

6. Industrial Infrastructure

Ports, transportation facilities, industrial campuses, and large utility installations often use high-capacity low-voltage switchboards.

The NW20N1 may be suitable for applications requiring a 2000 A four-pole fixed-mounted breaker frame, provided the full protection and accessory configuration is correctly specified.

Installation and System Integration

Correct installation is essential for the electrical safety and performance of a high-current air circuit breaker.

1. Verify the Electrical Ratings

Before installation, confirm the system voltage, rated current, frequency, prospective short-circuit current, and grounding arrangement.

The NW20N1 is rated for 2000 A at 40°C and has an N1 breaking capacity of 42 kA at 440 V AC. The selected breaker configuration must be suitable for the actual electrical network.

Do not select a breaker based only on the normal operating current. The calculated fault level and protection coordination requirements are equally important.

2. Confirm the Trip Unit Configuration

The specified NW20N1 frame does not include a control unit.

Before placing the breaker into service, select and install a compatible trip unit according to the intended protection requirements and manufacturer documentation.

The trip unit must be configured with suitable protection settings for the connected circuit. Incorrect settings may result in unwanted trips or inadequate protection.

3. Check Fixed-Mount Installation Requirements

The NW20N1 configuration discussed here is fixed-mounted. Confirm the mounting arrangement, switchboard support structure, connection positions, and required clearances before installation.

The switchboard must be designed to support the mechanical load and electrical stresses associated with a 2000 A circuit breaker.

4. Inspect Electrical Connections

High-current connections require correct conductor sizing, suitable terminal arrangements, and appropriate tightening procedures.

Inspect the busbar connections, contact surfaces, terminal hardware, and conductor routing. Follow the manufacturer’s specified torque values rather than using generic tightening recommendations.

5. Integrate Auxiliary Circuits

Depending on the selected configuration, the completed breaker assembly may use auxiliary contacts, shunt-trip accessories, undervoltage releases, motor mechanisms, or other control components.

These accessories can support remote monitoring, interlocking, and automated switching. Confirm the exact accessory compatibility before integrating them into the control system.

6. Commissioning and Functional Testing

Before energizing the switchboard, qualified personnel should verify the installation, insulation condition, mechanical operation, connection integrity, and protection settings.

Functional testing should confirm the correct operation of the breaker mechanism, trip unit, auxiliary circuits, and any electrical interlocks.

All commissioning and maintenance activities should follow the manufacturer’s instructions and applicable electrical safety standards.

Compatible System Components

The NW20N1 is normally incorporated into a larger low-voltage switchboard assembly. The following components may be relevant to a complete installation.

Component Function Integration Considerations
Compatible electronic trip unit Provides circuit protection functions Must be selected separately for this frame configuration
Main busbar system Distributes electrical power Must be rated for the installation current and fault withstand level
Auxiliary contacts Provide breaker status signals Confirm accessory type and contact arrangement
Shunt-trip release Allows remote tripping Verify control voltage and accessory compatibility
Undervoltage release Trips or prevents closing under specified voltage conditions Confirm the required voltage and control arrangement
Motor mechanism Supports electrically operated switching Check the applicable breaker accessories
Current transformers or sensors Provide current measurement for protection and monitoring Confirm the sensing arrangement required by the selected trip unit
Switchboard enclosure Houses the breaker and distribution components Verify dimensions, clearances, and mechanical support
Protection coordination system Coordinates upstream and downstream devices Perform a suitable protection study
PLC or monitoring system Supervises electrical equipment Use compatible auxiliary contacts or monitoring interfaces

These are potential system components, not a statement that they are included with the NW20N1 frame.

Alternative Models and Replacement Considerations

When replacing a MasterPact NW20N1, the complete breaker configuration must be compared rather than selecting a substitute based only on the 2000 A rating.

Alternative or Related Model Key Consideration
Schneider MasterPact NW20N1 3P fixed Same general family and performance class, but different pole configuration
Schneider MasterPact NW20N1 4P drawout Similar electrical rating, but mounting and cradle arrangement differ
Schneider MasterPact NW20H1 Higher breaking-capacity class; requires detailed configuration comparison
Schneider MasterPact NW20N1 with compatible trip unit May provide a more complete assembly when the frame and trip unit are correctly matched
Current-generation Schneider Electric MasterPact model May be considered for a modernization project, subject to engineering review

Before selecting a replacement, check:

  • Rated current and operating voltage.
  • Number of poles.
  • Ultimate and service short-circuit breaking capacities.
  • Fixed or drawout mounting arrangement.
  • Trip unit model and protection functions.
  • Busbar and terminal connection dimensions.
  • Auxiliary contacts and control accessories.
  • Mechanical and electrical interlocking requirements.
  • Switchboard dimensions and available installation space.
  • Applicable electrical standards and coordination requirements.

A breaker with the same rated current is not necessarily a direct replacement. Differences in pole count, mounting arrangement, trip unit, terminal layout, and accessory configuration may require modifications to the switchboard.

Key Advantages

High Current Capacity

The 2000 A rated current makes the NW20N1 suitable for appropriately designed high-current distribution applications.

Short-Circuit Interruption Capability

Its N1 performance classification provides a 42 kA ultimate breaking capacity at 440 V AC, supporting use in electrical networks with corresponding fault-level requirements.

Four-Pole Configuration

The four-pole arrangement supports switching of three phases and neutral where required by the distribution design.

Fixed-Mount Construction

The fixed-mounted configuration is suitable for switchboards designed around a permanent breaker installation.

MasterPact NW Platform

The product belongs to Schneider Electric’s MasterPact NW family, which offers a range of breaker frames, trip units, and accessories for low-voltage power distribution.

Integration into Industrial Switchboards

The frame can be incorporated into main distribution boards, feeder assemblies, and other high-current electrical installations when correctly configured.

Technical FAQs

1. What is the Schneider NW20N1?

The NW20N1 is a MasterPact NW air circuit breaker frame designed for low-voltage power distribution applications. The specified version is a 2000 A, four-pole, fixed-mounted configuration without a control unit.

2. What is the rated current of the NW20N1?

The rated current is 2000 A at 40°C.

3. What is the breaking capacity of the NW20N1?

The N1 performance classification provides a rated ultimate short-circuit breaking capacity of 42 kA at 440 V AC.

4. Is the NW20N1 a three-pole or four-pole breaker?

The configuration described here is four-pole. Other NW20N1 configurations are available with different pole arrangements, so the exact product configuration should always be checked.

5. Does this model include a trip unit?

No. The specified configuration is supplied without a control unit. A compatible trip unit must be selected separately according to the protection requirements.

6. Is the NW20N1 fixed-mounted or drawout?

The configuration described here is fixed-mounted. A drawout version has a different mounting arrangement and should not be treated as a direct mechanical replacement.

7. What is the rated operational voltage?

The product documentation specifies an operational voltage of up to 690 V AC at 50/60 Hz. The applicable breaking capacity must be checked at the actual operating voltage.

8. Can the NW20N1 be used as a main circuit breaker?

It may be used in a main distribution position when its current rating, breaking capacity, trip unit, and accessories meet the electrical system design requirements.

9. What should be checked before purchasing?

Verify the complete model designation, pole count, mounting type, trip unit status, accessory configuration, physical condition, and terminal arrangement. For critical applications, request appropriate inspection and functional test documentation.

10. What are the dimensions and weight?

The supplied listing dimensions are 352 × 537 × 297 mm, and the weight is 65 kg. These values correspond to the documented four-pole fixed-mounted configuration.

Procurement and Maintenance Recommendations

The Schneider Electric NW20N1 is a high-current electrical component, so procurement should be based on the exact configuration rather than the model family alone.

Before purchasing, confirm that the breaker is a four-pole fixed-mounted frame and that its 2000 A current rating and 42 kA N1 breaking capacity match the application. Check whether the trip unit, auxiliary contacts, operating mechanism, and other accessories are included or need to be sourced separately.

For new surplus, used, or refurbished equipment, request clear photographs of the nameplate, terminals, operating mechanism, and accessory positions. Confirm the product’s physical condition and obtain available inspection or testing records.

During maintenance, inspect the main contacts, connection points, operating mechanism, insulation components, and auxiliary circuits according to the manufacturer’s maintenance schedule. Check for overheating, abnormal wear, contamination, and loose connections.

Protection settings should be reviewed whenever the electrical distribution system changes. Any replacement trip unit or accessory must be compatible with the installed frame and the system’s protection coordination requirements.

High-current circuit breakers should only be installed, tested, and maintained by qualified electrical personnel using appropriate isolation procedures and manufacturer-approved instructions.

Conclusion

The Schneider Electric NW20N1 MasterPact Air Circuit Breaker is a 2000 A, four-pole, fixed-mounted breaker frame designed for industrial low-voltage power distribution. Its N1 performance classification provides a 42 kA ultimate short-circuit breaking capacity at 440 V AC, making it suitable for appropriately engineered high-current electrical systems.

The specified configuration does not include a control unit. Selecting a compatible trip unit and confirming the required accessories are therefore essential steps before commissioning. Accurate verification of pole count, mounting type, electrical ratings, and protection configuration helps ensure that the NW20N1 is correctly applied in industrial switchboards and power distribution systems.



Related Products