• Schneider NW20HA Circuit Breaker
  • Schneider NW20HA Circuit Breaker
  • Schneider NW20HA Circuit Breaker
  • Schneider NW20HA Circuit Breaker
Product Overview The Schneider Electric NW20HA MasterPact Switch Disconnector is a heavy-duty electrical switching and isolation device designed for low-voltage power distribution systems. It belongs to……
Schneider NW20HA Circuit Breaker
  • Schneider
  • NW20HA
  • Circuit Breaker
  • France
  • 442 x 352 x 297 mm
  • 60 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 5

Our advantage

Schneider NW20HA Circuit Breaker

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Schneider NW20HA Circuit Breaker

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Schneider NW20HA Circuit Breaker

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Schneider NW20HA Circuit Breaker

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Schneider Electric NW20HA MasterPact Switch Disconnector is a heavy-duty electrical switching and isolation device designed for low-voltage power distribution systems. It belongs to the MasterPact NW product family and is intended for applications requiring reliable manual switching and electrical isolation in industrial and commercial power installations.

With a rated operational current of 2000 A, the NW20HA is designed for high-current distribution circuits. Its three-pole configuration supports three-phase AC electrical systems, making it suitable for use in main distribution switchboards, industrial power panels, and large electrical installations.

Unlike an automatic circuit breaker, a switch disconnector does not independently provide automatic overload and short-circuit tripping. Its primary functions are to connect, disconnect, and isolate an electrical circuit. Appropriate upstream or associated protective devices must provide the required overcurrent and short-circuit protection.

The NW20HA has a rated operational voltage of up to 690 V AC and a rated insulation voltage of 1000 V AC. Its documented short-circuit making capacity is 143 kA under the specified conditions. This figure describes its ability to close onto a short-circuit condition; it should not be confused with an automatic circuit breaker’s short-circuit breaking capacity.

The product uses a fixed mounting arrangement and push-button operating control. Its robust construction and high-current rating make it suitable for electrical distribution systems where dependable switching and isolation are important.

For maintenance teams and electrical engineers, identifying the exact product type is essential. The NW20HA designation should not be confused with similarly named MasterPact NW automatic circuit breakers, which may have different protection functions, trip units, and accessory configurations.

Technical Specifications

Parameter Specification
Brand Schneider Electric
Product Family MasterPact NW
Model NW20HA
Product Type Switch Disconnector
Device Short Name MasterPact NW20
Rated Operational Current 2000 A
Number of Poles 3P
Network Type AC
Network Frequency 50/60 Hz
Rated Operational Voltage Up to 690 V AC
Rated Insulation Voltage 1000 V AC
Rated Impulse Withstand Voltage 12 kV
Rated Short-Circuit Making Capacity 143 kA, under specified conditions
Breaking Capacity Code HA
Mounting Type Fixed
Operating Control Push-button
Suitability for Isolation Yes
Connection Pitch 115 mm
Dimensions Provided 442 × 352 × 297 mm
Weight Provided 60 kg
Typical Application High-current industrial power distribution

Note: The product is identified as a switch disconnector. Its 143 kA rating is a short-circuit making capacity, not an automatic short-circuit breaking rating. Confirm the complete electrical configuration and associated protection devices before installation.

Function and Working Principle

The NW20HA is designed to provide controlled electrical connection, disconnection, and isolation in high-current distribution circuits. Its operation is based on a mechanical switching mechanism that opens or closes the main electrical contacts.

1. Electrical Circuit Switching

The main contacts establish or interrupt the electrical connection between the incoming and outgoing sides of the distribution circuit.

When the device is in the closed position, current can flow through its three main poles. When operated to the open position, the contacts separate and interrupt the normal current path.

This function allows operators to control the connection of electrical distribution sections and isolate equipment when required.

2. Three-Pole Switching

The three-pole configuration is designed for three-phase AC distribution systems. Each pole provides a switching path for one phase conductor.

Coordinated operation of the three poles helps ensure that the phases are switched together according to the device’s mechanical operating design.

Before installation, engineers should confirm the system configuration, rated voltage, current requirements, and connection arrangement.

3. Manual Operating Mechanism

The NW20HA uses push-button operating control. This allows authorized personnel to operate the switching mechanism according to the equipment’s operating procedures.

The mechanical arrangement is designed for industrial switchboard applications where reliable switching and clear operating procedures are important.

Operating procedures must account for the electrical condition of the circuit and any associated interlocking arrangements.

4. Electrical Isolation

One of the principal functions of a switch disconnector is to provide a means of isolating an electrical circuit.

Isolation is important during maintenance, inspection, and equipment replacement. However, opening the device alone should not be treated as proof that an installation is safe to work on.

Personnel must follow the applicable lockout and verification procedures, including confirming the absence of hazardous voltage and applying any required additional protective measures.

5. Short-Circuit Making Capability

The NW20HA has a specified short-circuit making capacity. This indicates its capability to close under the defined short-circuit conditions in accordance with the applicable rating.

This rating does not mean the device automatically detects and clears short-circuit faults. Suitable overcurrent protection must be provided by the associated protective equipment.

Role in Industrial Power Distribution Systems

The NW20HA can serve as a switching and isolation component in high-current electrical distribution systems. It is typically installed in a main switchboard or distribution assembly where electrical circuits need to be connected, disconnected, or isolated.

Main Distribution Switchboards

In industrial facilities, main switchboards distribute electrical power from incoming supplies to downstream feeders and distribution sections.

A 2000 A switch disconnector can be used in a suitably engineered distribution arrangement to control the connection of a high-current circuit.

Transformer Distribution Systems

Transformers supply electrical power to distribution networks with different voltage and current requirements. A switch disconnector may be incorporated into an appropriate transformer-side or downstream distribution arrangement.

The voltage class, fault level, protection coordination, and installation design must be reviewed before selecting the device.

Industrial Electrical Isolation

Manufacturing plants often require individual electrical sections to be isolated for maintenance or equipment modification.

The NW20HA can provide a switching and isolation point within a properly designed electrical system. Additional isolation procedures and safety devices may still be required depending on the installation.

Coordination with Protection Equipment

Because the NW20HA is a switch disconnector rather than an automatic circuit breaker, it must be used with an appropriate protection arrangement.

This may include protective relays, circuit breakers, or fuses selected according to the installation’s fault-current level and protection-coordination requirements.

Industrial Applications

1. Main Electrical Distribution Systems

Large industrial facilities require equipment capable of handling substantial electrical currents. The NW20HA’s 2000 A rating makes it relevant to suitably designed main distribution arrangements.

It can provide manual switching and isolation within a switchboard while associated protective equipment manages abnormal current conditions.

2. Manufacturing Plants

Manufacturing facilities often contain multiple production areas, electrical feeders, and auxiliary systems.

A switch disconnector can help operators isolate selected distribution sections during planned maintenance or equipment replacement.

3. Commercial and Industrial Buildings

Large commercial buildings, industrial complexes, and infrastructure facilities use high-current distribution equipment to manage incoming supplies and downstream electrical circuits.

The NW20HA may be considered where its voltage, current, pole configuration, and installation requirements match the distribution design.

4. Transformer and Feeder Sections

Electrical distribution networks frequently require switching points between transformers, busbars, and feeder circuits.

A suitable switch disconnector can provide a controlled means of connecting or isolating these sections as part of an engineered switching arrangement.

5. Power Distribution Switchboards

The device may be incorporated into fixed-mounted switchboard assemblies where a 2000 A switching and isolation function is required.

The switchboard designer must verify the available installation space, connection pitch, busbar arrangement, thermal conditions, and protection coordination.

Installation and System Integration

Correct installation is essential for electrical safety, mechanical reliability, and long-term performance.

1. Verify Electrical Ratings

Before installation, confirm that the system voltage, operating current, frequency, and fault level are compatible with the NW20HA.

The device has a rated operational current of 2000 A and a rated operational voltage of up to 690 V AC.

The short-circuit making capacity must be evaluated under the applicable system conditions. It must not be used as a substitute for checking the breaking capacity of the associated protective equipment.

2. Confirm Mounting Dimensions

The supplied dimensions are 442 × 352 × 297 mm. The manufacturer’s product information lists the corresponding height, width, and depth as 352 × 442 × 297 mm.

Before manufacturing or modifying a switchboard, verify the installation drawing and required mounting clearances.

Allow sufficient space for electrical connections, mechanical operation, inspection, and maintenance access.

3. Check Busbar and Cable Connections

High-current electrical connections require careful attention to conductor sizing, contact surfaces, connection pressure, and thermal performance.

The connection pitch is specified as 115 mm. Confirm the actual terminal arrangement and compatible busbar configuration before preparing the switchboard.

Connections should be installed according to the manufacturer’s instructions and applicable electrical standards.

4. Provide Appropriate Overcurrent Protection

The NW20HA is a switch disconnector and does not independently provide automatic overload or short-circuit tripping.

The system must include appropriately rated protective equipment, such as a circuit breaker, protective relay, or fuse arrangement.

Protection coordination should be assessed against the available fault current, cable ratings, downstream equipment, and applicable electrical regulations.

5. Grounding and Electrical Safety

The switchboard and associated metallic structures must be connected to the appropriate protective grounding system.

Before operating or servicing the device, personnel must follow established electrical safety procedures. This includes isolation, lockout, verification of de-energization, and any additional measures required by the installation.

6. Inspection and Commissioning

Before energizing the installation, inspect the mechanical mounting, electrical connections, insulation condition, and operating mechanism.

Confirm that the associated protection equipment is correctly installed and configured.

The commissioning process should include verification of switching operation, interlocks where applicable, and the electrical integrity of the complete distribution assembly.

Compatible System Components

The NW20HA is normally used as part of a larger electrical distribution system. Its associated components must be selected according to the system’s voltage, current, fault level, and protection requirements.

Component Function Integration Considerations
Protective circuit breaker Provides automatic overcurrent and short-circuit protection Select according to fault level and protection coordination
Protective relay Detects abnormal electrical conditions and initiates protective action Confirm compatibility with the associated switching equipment
Fuse system Provides overcurrent and short-circuit protection Verify voltage, current, and interrupting ratings
Main busbar Distributes high-current electrical power Match current rating, connection pitch, and thermal requirements
Distribution switchboard Houses switching and protection equipment Confirm dimensions, mounting, and internal clearances
Current transformer Provides current signals for measurement and protection Select appropriate ratio and accuracy class
Voltage transformer Supplies voltage signals for metering and protection Verify system voltage and insulation requirements
Grounding system Provides protective electrical grounding Follow applicable electrical standards
Auxiliary contacts Provide switching-status information where configured Verify the specific accessory and contact arrangement

These components are examples of equipment used in a complete distribution installation. They are not necessarily included with the NW20HA.

Alternative Models and Replacement Considerations

The MasterPact NW family includes several current ratings, mounting arrangements, and device types. When selecting an alternative, it is important to distinguish switch disconnectors from automatic circuit breakers.

Alternative Model or Family Description Replacement Considerations
MasterPact NW16HA 1600 A switch disconnector Lower current rating; verify system requirements
MasterPact NW20HA 2000 A switch disconnector Original model; confirm exact configuration
MasterPact NW32HA 3200 A switch disconnector Higher current rating; check switchboard compatibility
MasterPact NW20H automatic circuit breaker Automatic circuit breaker within the related NW family Different protective function; not a direct equivalent
MasterPact NT family Related Schneider Electric low-voltage power distribution range Requires full electrical and mechanical compatibility assessment
Current-generation Schneider Electric air circuit breaker or switch disconnector Potential modernization option Verify dimensions, ratings, accessories, and protection coordination

Before choosing a replacement, compare:

  • Rated operational current.
  • Rated operational voltage.
  • Number of poles.
  • Short-circuit making capacity.
  • Required short-circuit breaking capacity of the complete protection system.
  • Fixed or drawout mounting arrangement.
  • Busbar connection dimensions.
  • Mechanical operating mechanism.
  • Auxiliary contacts and accessories.
  • Switchboard dimensions and clearances.
  • Applicable electrical standards and installation requirements.

A 2000 A automatic circuit breaker and a 2000 A switch disconnector do not perform the same function. Replacing one with the other without reviewing the protection design may create a serious safety issue.

Key Advantages

High Current Capacity

The 2000 A operational current rating makes the NW20HA suitable for appropriately designed high-current distribution circuits.

Three-Pole Configuration

Its three-pole arrangement supports switching applications in three-phase AC electrical systems.

Electrical Isolation Function

The device provides a dedicated means of switching and isolating electrical circuits during planned maintenance and system operation.

Industrial Mechanical Design

The MasterPact NW platform is designed for demanding electrical distribution installations where reliable mechanical switching is important.

Defined Short-Circuit Making Capacity

Its specified short-circuit making capability provides an important parameter for evaluating its suitability within an engineered distribution system.

Fixed-Mount Installation

The fixed mounting arrangement supports installation in compatible switchboard designs.

Integration into Large Distribution Systems

The NW20HA can be incorporated into main distribution boards, feeder sections, and other high-current electrical installations when its ratings match the system design.

Technical FAQs

1. What is the Schneider Electric NW20HA?

The NW20HA is a MasterPact NW switch disconnector rated for 2000 A. It is designed for manual switching and electrical isolation in high-current AC distribution systems.

2. Is the NW20HA an automatic circuit breaker?

No. The NW20HA is identified by Schneider Electric as a switch disconnector. It does not independently provide automatic overload and short-circuit tripping. Suitable protective equipment must be installed in the electrical system.

3. What is the rated current of the NW20HA?

Its rated operational current is 2000 A.

4. How many poles does this model have?

The product configuration described here is three-pole (3P), intended for three-phase AC distribution applications.

5. What is the rated operating voltage?

The manufacturer’s product information specifies a rated operational voltage of up to 690 V AC at 50/60 Hz.

6. What does the 143 kA rating mean?

The 143 kA figure is the rated short-circuit making capacity under specified operating conditions. It describes the device’s ability to close onto a short-circuit condition and must not be interpreted as an automatic short-circuit breaking capacity.

7. What is the difference between a switch disconnector and a circuit breaker?

A switch disconnector provides switching and isolation functions. An automatic circuit breaker additionally provides automatic protection against specified overcurrent and short-circuit conditions through its protective mechanism or trip unit.

8. What is the mounting type of the NW20HA?

The referenced configuration is fixed-mounted. Confirm the exact product configuration and switchboard requirements before ordering.

9. What are the dimensions and weight?

The supplied dimensions are 442 × 352 × 297 mm, and the supplied weight is 60 kg. Schneider Electric lists the corresponding dimensions as 352 mm high, 442 mm wide, and 297 mm deep, with a net weight of 60 kg.

10. What should be checked before purchasing a replacement?

Confirm the complete model designation, rated current, voltage, pole configuration, mounting type, operating mechanism, connection arrangement, accessories, and the protection devices used in the installation. Ensure that the replacement performs the same switching and isolation function as the original device.

Procurement and Maintenance Recommendations

When sourcing the Schneider Electric NW20HA, buyers should verify that the product is the correct MasterPact NW switch disconnector rather than an automatic circuit breaker with a similar model designation.

The complete product configuration should be checked against the original equipment documentation. Important details include the 2000 A current rating, three-pole arrangement, fixed mounting, operating voltage, connection pitch, and mechanical operating mechanism.

For used or surplus equipment, request clear photographs of the product nameplate, front panel, main terminals, and mechanical operating components. Confirm the physical condition and ask for inspection or functional-test information where available.

During maintenance, inspect the main contact system, operating mechanism, terminal connections, and switchboard condition according to the manufacturer’s maintenance instructions. Look for signs of overheating, contamination, mechanical damage, or abnormal contact wear.

The associated protective devices should also be inspected and tested according to the electrical system’s maintenance schedule. Since the NW20HA does not provide automatic overcurrent protection by itself, the condition and correct operation of the complete protection arrangement are particularly important.

For replacement projects, review the switchboard drawings and protection-coordination study before installation. Differences in mounting, terminal spacing, operating mechanism, or electrical ratings may require modifications to the existing assembly.

Conclusion

The Schneider Electric NW20HA MasterPact switch disconnector is a 2000 A, three-pole device designed for high-current AC electrical distribution systems. With a rated operational voltage of up to 690 V AC, fixed mounting, and a defined short-circuit making capacity, it provides a switching and isolation function for suitable industrial and commercial installations.

The NW20HA must be distinguished from an automatic circuit breaker because it does not independently provide overload or short-circuit tripping. Appropriate protective equipment is essential for safe system operation.

For maintenance, procurement, and replacement projects, verifying the complete model designation, electrical ratings, mounting arrangement, and associated protection system helps ensure that the selected device matches the requirements of the existing installation.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501