• Schneider NW08HA Circuit Breaker
  • Schneider NW08HA Circuit Breaker
  • Schneider NW08HA Circuit Breaker
  • Schneider NW08HA Circuit Breaker
Product Overview The Schneider Electric NW08HA MasterPact Switch-Disconnector is an industrial low-voltage power switching and isolation device designed for high-current electrical distribution systems.……
Schneider NW08HA Circuit Breaker
  • Schneider
  • NW08HA
  • Circuit Breaker
  • France
  • 537 x 352 x 297 mm
  • 80 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 5

Our advantage

Schneider NW08HA Circuit Breaker

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Schneider NW08HA Circuit Breaker

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Schneider NW08HA Circuit Breaker

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Schneider NW08HA Circuit Breaker

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Schneider Electric NW08HA MasterPact Switch-Disconnector is an industrial low-voltage power switching and isolation device designed for high-current electrical distribution systems. Belonging to the MasterPact NW product family, it is intended for applications where reliable load switching, electrical isolation, and controlled power distribution are essential.

With an 800 A rated operational current, the NW08HA is designed for demanding electrical installations in industrial facilities, commercial buildings, and large power distribution networks. Its robust construction supports integration into main distribution boards and switchgear assemblies where high-current circuits must be managed safely.

An important distinction is that the NW08HA is a switch-disconnector rather than a conventional automatic circuit breaker. It provides switching and isolation functions, but it should not be treated as an independently operating overcurrent protection device. Appropriate external protection, such as a coordinated circuit breaker, fuse, or overcurrent relay arrangement, must be provided according to the electrical system design.

The MasterPact NW platform is designed for industrial power distribution applications that require high current capacity, mechanical durability, and reliable switching performance. The NW08HA configuration provides an 800 A current rating and is available in different pole and mounting arrangements depending on the complete product configuration.

Before purchasing, users should verify whether the required unit is fixed-mounted or drawout, three-pole or four-pole, and confirm the associated chassis, connections, operating mechanism, and accessories.

Technical Specifications

Parameter Specification
Brand Schneider Electric
Product Series MasterPact NW
Model NW08HA
Product Type Switch-Disconnector
Application Power Distribution and Electrical Isolation
Frame Rating 800 A
Rated Operational Current 800 A
Rated Operational Voltage Up to 690 V AC
Network Type AC
Network Frequency 50/60 Hz
Rated Insulation Voltage 1000 V AC
Rated Impulse Withstand Voltage 12 kV
Rated Short-Circuit Making Capacity 143 kA at specified operating conditions
Rated Short-Time Withstand Current 65 kA for 1 second
Poles 3P or 4P, depending on configuration
Mounting Options Fixed or Drawout, depending on configuration
Suitability for Isolation Yes
Product Family MasterPact NW
Dimensions 537 × 352 × 297 mm
Weight 80 kg

Note: Electrical ratings and mounting arrangements must be checked against the exact pole configuration and product variant. Short-circuit making capacity is not the same as automatic circuit-breaker breaking capacity.

Function and Working Principle

The NW08HA is designed to establish, carry, and interrupt electrical current under its specified switching conditions. It also provides an isolation function that allows an electrical circuit to be separated from its supply for appropriate maintenance or system operations.

1. High-Current Switching

The device is designed for electrical distribution systems with a rated operational current of 800 A.

Its main contacts provide the electrical path between the incoming supply and the connected distribution circuit. When the operating mechanism changes the contact position, the circuit can be connected or disconnected according to the device’s operating specifications.

This capability is useful in industrial switchgear where operators need to control the connection of high-current electrical circuits.

2. Electrical Isolation

Isolation is an important requirement in industrial electrical maintenance.

The NW08HA is suitable for isolation when installed and operated according to its specified conditions. Its contact position indication helps operators identify the device’s switching state.

However, isolation procedures must follow the installation’s safety requirements. Operators should verify the absence of voltage using appropriate test equipment and apply the required lockout and tagout procedures before working on electrical equipment.

3. Short-Circuit Making Capability

The NW08HA has a specified short-circuit making capacity. This rating describes its ability to close onto a circuit under defined short-circuit conditions.

It should not be confused with the interrupting capacity of an automatic circuit breaker. The NW08HA requires an appropriate external protective arrangement to detect and clear overcurrent and short-circuit conditions.

The protective device must be coordinated with the switch-disconnector and the electrical installation’s prospective fault current.

4. Mechanical Operating Mechanism

The MasterPact NW platform uses a mechanical operating arrangement to control the movement of its contacts.

Depending on the complete configuration, operation may involve manual or electrically operated accessories. The specific mechanism, control voltage, and auxiliary functions must be verified against the full product reference.

Correct mechanical operation is essential for reliable switching and isolation.

5. Contact Position Indication

Contact position indication provides information about the operating state of the device.

This is useful for electrical maintenance, switching procedures, and integration into power distribution monitoring systems. Position indication should be used together with the appropriate electrical verification procedures rather than as the only confirmation that a circuit is safe.

Role in Industrial Power Distribution Systems

The NW08HA can serve as a high-current switching and isolation component within an industrial electrical distribution architecture.

Main Distribution Boards

In main distribution boards, the device can be used to connect or isolate high-current distribution sections. Its 800 A rating makes it suitable for appropriately designed power distribution arrangements.

It may be installed as part of a larger switchgear assembly containing protective devices, busbars, metering equipment, and control components.

Electrical Switchgear Integration

The MasterPact NW platform is designed for integration into industrial switchgear systems.

Depending on the selected version, the NW08HA may use a fixed or drawout mounting arrangement. Drawout configurations can support maintenance and equipment replacement procedures by allowing the switching device to be withdrawn from its chassis under the prescribed conditions.

The complete switchgear assembly must be designed for the applicable voltage, current, short-circuit conditions, and installation environment.

External Protection Coordination

Because the NW08HA is a switch-disconnector, external overcurrent protection is an essential part of the electrical design.

A suitable circuit breaker, fuse, or protective relay arrangement must be selected to provide the required fault detection and interruption. Coordination must consider the device ratings, prospective short-circuit current, and applicable electrical standards.

Power System Maintenance

The device can provide an isolation point for maintenance operations when correctly incorporated into the electrical safety system.

Its position indication and mechanical operating arrangement support switching procedures, but safe maintenance still requires approved isolation, voltage testing, and lockout procedures.

Industrial Applications

The Schneider Electric NW08HA is intended for high-current electrical distribution and isolation applications.

1. Industrial Main Switchboards

Large industrial facilities use main switchboards to distribute electrical power to production lines, auxiliary systems, and building services.

An 800 A switch-disconnector can be incorporated into an appropriately rated distribution assembly to provide circuit switching and isolation.

2. Power Distribution Systems

Industrial power distribution networks often contain multiple distribution sections and high-current feeders.

The NW08HA can be used where a high-current switching and isolation device is required. Its suitability depends on the system voltage, load current, external protection arrangement, and installation design.

3. Manufacturing Facilities

Manufacturing plants operate motors, production equipment, heating systems, and auxiliary electrical loads.

A MasterPact NW switch-disconnector may be incorporated into the facility’s main or secondary distribution switchgear to support power management and maintenance isolation.

4. Commercial and Infrastructure Facilities

Large commercial buildings and infrastructure facilities may require high-capacity electrical distribution equipment.

The NW08HA can be considered for suitable switchgear installations where its current rating, voltage characteristics, and switching functions meet the system requirements.

5. Generator and Power Supply Distribution

Generator installations and other power supply systems may require switching and isolation devices between electrical sources and distribution equipment.

The NW08HA can be used in an appropriately engineered arrangement. Source transfer, synchronization, interlocking, and fault protection must be handled by the complete system design.

Installation and System Integration

Correct installation is essential for the safe and reliable operation of the NW08HA.

1. Verify the Electrical Ratings

Before installation, confirm the system voltage, rated current, network frequency, number of poles, and available short-circuit current.

The device has an 800 A rated operational current. The external protective equipment must be coordinated with the switch-disconnector and the electrical installation.

Never select the device based only on its current rating. Its voltage and short-circuit characteristics must also satisfy the application requirements.

2. Confirm the Mounting Configuration

The NW08HA is available in different mounting arrangements depending on the complete configuration.

Check whether the required device is fixed-mounted or drawout. For drawout versions, verify chassis compatibility, connection arrangements, and the mechanical interlocking requirements.

The supplied dimensions are 537 × 352 × 297 mm. Confirm the dimensional drawing for the exact version before designing the switchgear compartment.

3. Busbar and Electrical Connections

The device must be connected to appropriately rated busbars and conductors.

Connection design should account for current capacity, temperature rise, conductor material, mechanical support, and short-circuit forces.

All electrical connections should be tightened according to the manufacturer’s specified torque values. Incorrect connections can result in overheating, contact damage, and equipment failure.

4. External Protection Coordination

Install suitable overcurrent protection in accordance with the electrical system design.

The protective device must be capable of detecting and interrupting fault currents within the required limits. Its coordination with the NW08HA must be verified before the switchgear is energized.

5. Grounding and Safety

Ensure that the switchgear enclosure and associated equipment are correctly grounded.

Before maintenance, isolate the relevant circuit, follow the required switching sequence, verify the absence of voltage, and apply lockout and tagout procedures.

Only qualified electrical personnel should install, operate, or maintain high-current switchgear.

6. Commissioning and Functional Testing

Before energizing the equipment, inspect the mechanical installation, electrical connections, busbar alignment, grounding, and operating mechanism.

Check the contact position indication and confirm the operation of any installed auxiliary devices.

Commissioning should also include verification of the external protective equipment, electrical interlocks, and applicable switchgear safety functions.

Compatible System Components

The NW08HA is normally installed as part of a complete electrical distribution and protection system.

Component Function Integration Considerations
MasterPact NW chassis Supports the drawout device where applicable Confirm exact frame and mounting compatibility
Main busbars Distribute high-current electrical power Verify current capacity and short-circuit withstand rating
External circuit breaker Provides overcurrent and short-circuit interruption Coordinate with the switch-disconnector
Protective relay Detects abnormal electrical conditions Confirm trip logic and protection settings
Current transformers Provide current measurement signals Select suitable ratios and accuracy classes
Voltage transformers Provide voltage measurement signals Verify voltage rating and protection requirements
Auxiliary contacts Provide device position or status signals Confirm contact configuration and control voltage
Electrical operating accessories Support remote or electrically controlled operation Verify exact device compatibility
Switchgear enclosure Provides mechanical and environmental protection Confirm dimensions, clearances, and thermal requirements
Power monitoring equipment Measures electrical operating conditions Integrate according to the control and monitoring architecture

Accessories and external components are not necessarily included with the NW08HA. Verify the complete bill of materials before ordering.

Alternative Models and Replacement Considerations

When replacing or upgrading an existing MasterPact NW08HA installation, the replacement must match the electrical and mechanical requirements of the original system.

Related Model General Description Replacement Considerations
MasterPact NW08H1 800 A circuit breaker configuration Different protection function; not a direct substitute without system redesign
MasterPact NW08H2 800 A circuit breaker configuration with a different performance class Check interrupting ratings and protection requirements
MasterPact NW08HF 800 A high-performance circuit breaker configuration Verify the required breaking capacity and mounting arrangement
MasterPact NW16HA 1600 A switch-disconnector family member Higher current rating; not a direct replacement
MasterPact NW20HA 2000 A switch-disconnector family member Intended for a different current range
MasterPact NW32HA 3200 A switch-disconnector family member Requires a different switchgear design and connection arrangement

A replacement evaluation should include:

  • Rated operational current.
  • Rated operational and insulation voltage.
  • Number of poles.
  • Short-circuit making and withstand ratings.
  • Fixed or drawout mounting arrangement.
  • Chassis and busbar compatibility.
  • Auxiliary contact configuration.
  • Electrical operating accessories.
  • External overcurrent protection coordination.
  • Mechanical dimensions and switchgear compartment requirements.

A circuit breaker and a switch-disconnector perform different functions. Replacing one with the other requires a full protection and system-design review.

Key Advantages

High Current Capacity

The NW08HA has an 800 A rated operational current, making it suitable for appropriately designed high-current distribution systems.

Reliable Switching Function

Its mechanical contact arrangement supports the switching and isolation requirements of industrial electrical installations.

Isolation Capability

The device is suitable for isolation under its specified operating conditions, supporting maintenance and electrical safety procedures.

MasterPact NW Platform

The product belongs to Schneider Electric’s established MasterPact NW family, which is designed for industrial and commercial power distribution applications.

Multiple Mounting Arrangements

Depending on the complete configuration, fixed and drawout mounting arrangements are available to suit different switchgear designs.

High Mechanical Durability

The MasterPact platform is designed for repeated switching operations. Actual service life depends on operating conditions, maintenance practices, and the selected configuration.

Integration into Industrial Switchgear

The device can be incorporated into distribution boards and switchgear assemblies alongside busbars, protective relays, external circuit breakers, and monitoring equipment.

Technical FAQs

1. What is the Schneider NW08HA?

The Schneider Electric NW08HA is an 800 A MasterPact NW switch-disconnector designed for high-current electrical switching and isolation applications.

2. Is the NW08HA an automatic circuit breaker?

No. The NW08HA is a switch-disconnector. It provides switching and isolation functions but does not replace an independently coordinated overcurrent protection device.

3. What is the rated current of the NW08HA?

Its rated operational current is 800 A.

4. What voltage can the NW08HA operate at?

The manufacturer specifies a rated operational voltage of up to 690 V AC, depending on the applicable operating conditions and configuration.

5. What is the rated insulation voltage?

The specified rated insulation voltage is 1000 V AC, with a rated impulse withstand voltage of 12 kV.

6. Does the NW08HA provide short-circuit protection?

It has a specified short-circuit making and withstand capability, but it does not independently provide automatic fault interruption. Suitable external protection must be installed and coordinated with the device.

7. Is the NW08HA available in fixed and drawout versions?

Different mounting arrangements are available within the product family. The exact configuration should be confirmed from the complete product reference and nameplate.

8. What is the weight of the NW08HA?

The supplied product weight is 80 kg. This figure should be checked against the exact pole and mounting configuration when arranging transportation.

9. What should be checked before purchasing?

Verify the complete model identification, rated current, voltage, number of poles, mounting arrangement, chassis compatibility, accessories, and physical condition. Also confirm that the external protection arrangement is suitable.

10. Can the NW08HA replace a MasterPact NW08H1 circuit breaker?

Not as a direct functional replacement. The NW08HA is a switch-disconnector, while the NW08H1 is a circuit breaker configuration. A substitution requires a review of the protection architecture and switchgear design.

Procurement and Maintenance Recommendations

When sourcing a Schneider Electric NW08HA, confirm the complete product reference and the exact mechanical configuration. The product family includes different pole arrangements and mounting options, so the basic model designation alone may not identify every required accessory or installation detail.

For replacement projects, compare the existing unit’s nameplate, current rating, voltage rating, connection arrangement, and chassis configuration. Confirm whether the installation uses a fixed or drawout arrangement and whether auxiliary contacts or electrical operating accessories are required.

For used or surplus equipment, request clear photographs of the nameplate, main contacts, terminals, operating mechanism, and any included accessories. Check the condition of the contact surfaces and mechanical components. Where possible, obtain inspection and functional test records.

During maintenance, follow the manufacturer’s inspection procedures and applicable electrical safety standards. Inspect electrical connections, busbar joints, mechanical operation, insulation condition, and auxiliary devices at the recommended intervals.

The NW08HA must always be used with a suitable external protection arrangement. Its switching and isolation functions should not be mistaken for the fault-interruption capability of an automatic circuit breaker.

Conclusion

The Schneider Electric NW08HA MasterPact 800A Switch-Disconnector is designed for high-current industrial power distribution applications that require reliable switching and electrical isolation. With an 800 A rated operational current, 690 V AC operational voltage capability, and a robust MasterPact NW platform, it can be incorporated into appropriately engineered industrial switchgear systems.

For maintenance and replacement projects, the most important considerations are the exact mounting configuration, pole arrangement, electrical ratings, external protection coordination, and mechanical compatibility. Correct product identification and installation help maintain safe and reliable operation in industrial power distribution systems.



Related Products