• Schneider NS800N Circuit Breaker
  • Schneider NS800N Circuit Breaker
  • Schneider NS800N Circuit Breaker
  • Schneider NS800N Circuit Breaker
Product Overview The Schneider Electric NS800N Circuit Breaker is a low-voltage power distribution protection device belonging to the ComPacT NS630b–1600 product family. Designed for industrial and comm……
Schneider NS800N Circuit Breaker
  • Schneider
  • NS800N
  • Circuit Breaker
  • France
  • 327 x 280 x 147 mm
  • 18 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 5

Our advantage

Schneider NS800N Circuit Breaker

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Schneider NS800N Circuit Breaker

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Schneider NS800N Circuit Breaker

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Schneider NS800N Circuit Breaker

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Schneider Electric NS800N Circuit Breaker is a low-voltage power distribution protection device belonging to the ComPacT NS630b–1600 product family. Designed for industrial and commercial electrical distribution systems, the NS800N platform provides circuit switching, isolation, and protection against abnormal electrical conditions.

With a rated current of 800 A, the NS800N is intended for installations where substantial electrical loads must be distributed and protected. It can be used in main distribution boards, industrial switchboards, power control centers, and other low-voltage electrical installations.

The NS800N designation identifies the circuit-breaker performance class and frame family rather than every detail of an individual assembled breaker. Depending on the selected configuration, the product may be supplied as a three-pole or four-pole unit, with different mounting arrangements, operating mechanisms, and trip-unit options.

The N breaking-capacity class provides an ultimate short-circuit breaking capacity of 50 kA at 380/415 V AC under the applicable IEC 60947-2 conditions. The platform also supports operation at rated voltages up to 690 V AC, with breaking capacity dependent on the actual operating voltage and configuration.

In a distribution system, the circuit breaker performs an important protective function. It can interrupt current when the electrical circuit experiences an overload or short circuit, helping limit damage to cables, connected equipment, and distribution assemblies. Its isolation capability also supports maintenance and electrical system management when applied according to the relevant safety procedures.

The NS800N is suitable for applications requiring high-current distribution protection, but correct selection requires more than checking the 800 A rating. Engineers should verify the number of poles, trip-unit characteristics, rated voltage, short-circuit level, mounting type, and operating mechanism before installation or replacement.

Technical Specifications

Parameter Specification
Brand Schneider Electric
Product Series ComPacT NS
Model NS800N
Product Type Low-Voltage Circuit Breaker
Device Application Power Distribution
Rated Current 800 A
Rated Operational Voltage Up to 690 V AC
Network Type AC
Network Frequency 50/60 Hz
Breaking Capacity Class N
Ultimate Breaking Capacity at 380/415 V AC 50 kA
Ultimate Breaking Capacity at 220/240 V AC 85 kA
Ultimate Breaking Capacity at 440 V AC 50 kA
Ultimate Breaking Capacity at 500/525 V AC 40 kA
Ultimate Breaking Capacity at 660/690 V AC 30 kA
Rated Insulation Voltage 800 V AC for the documented configuration
Rated Impulse Withstand Voltage 8 kV
Utilization Category Category B
Number of Poles 3P or 4P, depending on configuration
Mounting Type Fixed or withdrawable, depending on configuration
Operating Mechanism Manual or electrical, depending on configuration
Trip Unit Depends on the selected assembly
Dimensions Provided 327 × 280 × 147 mm
Weight Provided 18 kg
Typical Applications Main distribution, industrial switchboards, power control centers

Important: The dimensions provided correspond to a documented four-pole NS800N basic-frame configuration. The complete breaker specification depends on its pole arrangement, trip unit, mounting type, and operating mechanism. The 18 kg weight is the supplied listing value and should be verified against the actual assembly.

Function and Working Principle

The NS800N is designed to protect and control high-current electrical distribution circuits. Its operation combines switching, electrical isolation, and protective interruption.

1. Overload Protection

An overload occurs when a circuit carries more current than its intended operating level for a sustained period. Excessive current can cause cables, busbars, and connected electrical equipment to overheat.

When equipped with an appropriate protection unit, the circuit breaker can detect an overload condition and initiate an interruption according to its configured protection characteristics.

The selected trip unit and settings determine the overload protection behavior. Engineers must coordinate these settings with the rated current of the downstream conductors and the characteristics of the connected loads.

2. Short-Circuit Protection

A short circuit can produce a very high fault current within a short period. Without suitable protection, the resulting thermal and electrodynamic forces can damage electrical equipment and create serious safety risks.

The NS800N N-class platform has a 50 kA ultimate breaking capacity at 380/415 V AC. This indicates the maximum short-circuit current the breaker is designed to interrupt under the specified test conditions.

The actual available fault current at the installation point must be calculated or assessed. The selected breaker must have an adequate breaking capacity for the electrical system in which it is installed.

3. Circuit Switching

The breaker can be used to connect and disconnect electrical circuits during normal operation, subject to its rated operating conditions.

Manual operating arrangements allow authorized personnel to operate the breaker locally. Electrical operating mechanisms, where included, can support remote switching as part of a wider power distribution or automation system.

The operating method must be confirmed from the complete product configuration.

4. Electrical Isolation

The NS800N platform is suitable for isolation according to the applicable IEC 60947-2 requirements when used in the corresponding approved configuration.

Isolation is important during inspection, maintenance, and equipment replacement. However, operating the breaker handle alone does not replace site-specific lockout procedures or verification that the circuit is de-energized.

5. Selective Coordination

In a multi-level distribution network, protective devices should be coordinated so that a fault is interrupted by the breaker closest to the affected circuit whenever possible.

This approach can help limit unnecessary interruptions to other sections of the facility.

The NS800N’s Category B classification and short-time withstand characteristics support coordination studies, but actual selectivity depends on the complete protection scheme, trip-unit settings, and upstream and downstream devices.

Role in Industrial Power Distribution Systems

The NS800N is generally installed in a low-voltage distribution assembly where it protects a major feeder or distribution section.

Main Distribution Protection

In an industrial electrical room, the NS800N may be installed in a main or sub-main distribution board. It can protect a feeder supplying production equipment, motor control centers, or secondary distribution panels.

The 800 A rating makes it suitable for appropriately designed high-current distribution circuits. The actual load current, cable capacity, fault level, and environmental conditions must be considered before selection.

Protection of Downstream Equipment

A distribution system often supplies multiple types of equipment, including motor control centers, transformers, power supplies, and industrial machinery.

The NS800N can serve as an upstream protective device for a suitable distribution section. Correct protection coordination helps ensure that downstream faults do not cause unnecessary interruption of the entire installation.

Integration with Electrical Monitoring Systems

When suitable auxiliary contacts, trip indication accessories, or monitoring devices are installed, breaker status can be incorporated into an electrical monitoring system.

A PLC, power management controller, or supervisory system may receive status signals and use them for alarms, equipment sequencing, or operational monitoring.

The availability of these functions depends on the installed accessories and breaker configuration. They should not be assumed to be included with every NS800N unit.

Industrial Applications

The Schneider Electric NS800N is designed for high-current low-voltage distribution applications.

1. Industrial Main Distribution Boards

Manufacturing facilities require reliable protection for incoming and outgoing distribution circuits. The NS800N can be applied to suitable high-current feeders in industrial switchboards.

Its breaking capacity must be matched to the prospective fault current at the installation point.

2. Motor Control Centers

Motor control centers distribute power to multiple motors, drives, and auxiliary systems. A suitably configured NS800N may serve as an upstream protective device for an MCC section or feeder.

Protection coordination is particularly important where motors have high starting currents or where several loads operate simultaneously.

3. Power Distribution Panels

Large distribution panels supply electrical power to production lines, building services, and industrial equipment. The NS800N can help protect a major distribution circuit against overloads and short circuits when correctly selected.

4. Transformer Secondary Protection

The breaker may be considered for a suitable low-voltage transformer secondary circuit. Selection must account for transformer rated current, impedance, prospective short-circuit current, and the protection requirements of the connected distribution network.

5. Commercial and Infrastructure Electrical Systems

Large commercial buildings, infrastructure facilities, and utility-related installations may use high-current circuit breakers in their low-voltage distribution systems.

The NS800N can be considered where its electrical ratings, breaking capacity, installation arrangement, and applicable standards meet the project requirements.

6. Industrial Power Control Centers

Power control centers often contain multiple distribution and control sections. The NS800N can provide protection and switching for a major feeder within an appropriately designed assembly.

Its use should be coordinated with busbar ratings, enclosure design, ventilation, and the complete protection system.

Installation and System Integration

Proper installation is essential for electrical safety and reliable circuit protection.

1. Verify the Complete Product Configuration

Before installation, identify whether the supplied breaker is a three-pole or four-pole version. Confirm the mounting arrangement, operating mechanism, trip-unit type, and accessory configuration.

The NS800N model designation alone does not identify all these details.

The supplied dimensions of 327 × 280 × 147 mm correspond to a four-pole basic-frame configuration in the manufacturer’s product information. A three-pole version has a different width.

2. Check Electrical Ratings

Confirm that the rated operational voltage, rated current, and breaking capacity are suitable for the installation.

The 800 A rating should not be interpreted as a universal current setting. The protection arrangement must be coordinated with the connected cables, busbars, loads, and upstream power source.

A short-circuit study should be used to verify that the selected breaking capacity is adequate for the actual prospective fault current.

3. Panel Mounting and Mechanical Installation

Install the breaker in a compatible switchboard or distribution assembly. Check mounting points, terminal arrangements, clearances, and access for maintenance.

The switchboard must be designed to withstand the thermal and mechanical effects associated with the available fault current.

Ensure that the breaker is securely mounted and that all mechanical operating components move correctly before energizing the installation.

4. Electrical Connections

Use conductors and busbars with suitable current-carrying capacity. Follow the manufacturer’s terminal connection requirements, including tightening torque and connection preparation.

Incorrect terminal installation can result in excessive contact resistance, overheating, and equipment damage.

Protective grounding and the overall switchboard bonding arrangement must comply with the applicable electrical standards.

5. Trip-Unit Configuration

The trip unit is a critical part of the complete circuit-breaker assembly. Confirm its protection functions and settings before commissioning.

Depending on the selected trip unit, available protection functions may include long-time, short-time, and instantaneous protection.

Settings should be based on a protection coordination study rather than selected arbitrarily. Incorrect settings may cause nuisance tripping or inadequate protection.

6. Commissioning and Functional Testing

Before placing the breaker into service, inspect the mechanical assembly, terminals, operating mechanism, and installed accessories.

Verify the protection settings and perform the required commissioning tests according to the manufacturer’s procedures and applicable site standards.

Document the final settings and test results for future maintenance.

Compatible System Components

The NS800N is normally installed as part of a larger low-voltage distribution assembly.

Component Function Compatibility Considerations
Schneider Electric ComPacT NS800N frame Main circuit-breaker assembly Confirm pole count, mounting type, and complete catalog reference
Electronic trip unit Provides configurable electrical protection Select according to required protection functions and breaker compatibility
Auxiliary contacts Provide breaker position information Confirm accessory type and contact arrangement
Trip indication contacts Report trip conditions Verify compatibility with the installed breaker
Motor mechanism Supports electrical operation Required only for configurations designed for remote operation
Busbar system Distributes electrical power Check current rating, dimensions, and short-circuit withstand capability
Switchboard enclosure Houses and protects the distribution equipment Confirm mechanical and thermal design
Upstream protective device Provides coordinated upstream protection Perform a protection coordination study
PLC or power monitoring system Monitors electrical equipment status Requires suitable auxiliary contacts or monitoring accessories

The components listed above are examples of equipment used in a complete distribution installation. They are not necessarily supplied with every NS800N circuit breaker.

Alternative Models and Replacement Considerations

When replacing an NS800N, engineers should compare the full electrical and mechanical configuration rather than selecting a breaker based only on its 800 A rating.

Alternative or Related Model Replacement Considerations
Schneider Electric ComPacT NS800H Different breaking-capacity class; verify the system fault level and configuration
Schneider Electric ComPacT NS800L Higher breaking-capacity class; confirm dimensions and accessory compatibility
Schneider Electric ComPacT NS1000N Higher current rating; not a direct substitute without system evaluation
Schneider Electric ComPacT NS630bN Lower rated current; assess load and protection requirements
Schneider Electric ComPacT NS new-generation range May be considered for modernization, subject to dimensional and electrical compatibility

Before selecting a replacement, compare:

  • Rated current and frame size.
  • Rated operational voltage.
  • Ultimate and service breaking capacity.
  • Three-pole or four-pole configuration.
  • Fixed or withdrawable mounting.
  • Manual or electrical operating mechanism.
  • Trip-unit type and protection functions.
  • Auxiliary contacts and other accessories.
  • Terminal and busbar arrangements.
  • Overall dimensions and switchboard clearances.
  • Protection coordination with upstream and downstream devices.

A replacement breaker may require changes to the switchboard, busbar connections, protection settings, or auxiliary wiring. Compatibility should be confirmed by a qualified electrical engineer.

Key Advantages

High Current Rating

The 800 A rated-current class makes the NS800N suitable for appropriately designed high-current distribution circuits.

Short-Circuit Protection

The N breaking-capacity class provides 50 kA ultimate breaking capacity at 380/415 V AC under the applicable test conditions.

Multiple Configuration Options

The NS800N platform is available in different pole arrangements, mounting types, and operating configurations, allowing it to be adapted to different distribution designs.

Isolation Capability

The platform supports circuit isolation in accordance with the relevant IEC requirements when used in an appropriate configuration.

Industrial Distribution Applications

The breaker is designed for use in industrial and commercial low-voltage distribution systems, including main distribution boards and power control centers.

Accessory and Monitoring Options

Compatible auxiliary and operating accessories can support breaker status monitoring and system integration, depending on the selected assembly.

Established ComPacT NS Platform

The ComPacT NS family is used in industrial power distribution installations. Accurate model and accessory identification supports maintenance and replacement planning.

Technical FAQs

1. What is the Schneider Electric NS800N?

The NS800N is an 800 A low-voltage circuit-breaker model in the Schneider Electric ComPacT NS family. It is designed for power distribution and circuit protection in industrial and commercial installations.

2. What is the rated current of the NS800N?

The rated current is 800 A at the specified reference ambient condition of 50 °C. The actual protection settings and application suitability depend on the installed trip unit and system design.

3. What is the breaking capacity of the NS800N?

The N-class model provides 50 kA ultimate breaking capacity at 380/415 V AC. The breaking capacity varies with operating voltage, so the actual system voltage must be checked.

4. Is the NS800N available in three-pole and four-pole versions?

Yes. The ComPacT NS800N platform includes both three-pole and four-pole configurations. Their dimensions and neutral arrangements differ.

5. Does the NS800N include an electronic trip unit?

Not every NS800N basic frame includes a trip unit. Some configurations are supplied as basic frames without a trip unit, while complete breaker assemblies may include a specified electronic release. Check the full catalog number and product label.

6. What is the difference between NS800N and NS800H?

They belong to different breaking-capacity classes. The N version is rated at 50 kA at 415 V AC, while the H version has a different, higher breaking-capacity rating. The exact specifications should be compared at the intended system voltage.

7. Can the NS800N be used for transformer protection?

It may be suitable for a transformer-related distribution circuit if the current rating, short-circuit capacity, trip characteristics, and coordination requirements are satisfied. The selection must be based on the transformer and system data.

8. Can the breaker be operated remotely?

Certain NS800N configurations can be equipped with an electrical operating mechanism. A manually operated basic frame does not automatically provide remote operation. Confirm the installed mechanism and accessories.

9. What should be checked before purchasing an NS800N?

Verify the full catalog reference, pole count, trip unit, rated current, breaking capacity, mounting type, operating mechanism, accessories, physical condition, and terminal configuration. For replacement projects, compare the original unit’s nameplate and installation drawings.

10. Are the dimensions 327 × 280 × 147 mm correct?

These dimensions match a documented four-pole ComPacT NS800N basic-frame configuration. The three-pole version has a different width. Confirm the actual breaker assembly and mounting arrangement before using the dimensions for panel design.

Procurement and Maintenance Recommendations

When purchasing the Schneider Electric NS800N, begin by identifying the complete breaker configuration. The NS800N designation alone does not specify the number of poles, trip unit, mounting type, or operating mechanism.

For replacement applications, compare the existing breaker’s nameplate and catalog reference with the proposed unit. Verify the rated current, voltage, breaking capacity, trip characteristics, terminal arrangement, and accessory configuration.

For used or surplus equipment, request clear photographs of the front label, terminals, operating mechanism, and trip unit. Check for signs of overheating, damaged insulation, corrosion, mechanical wear, or previous fault operation. Confirm the condition and availability of compatible accessories.

During maintenance, inspect terminals, busbar connections, mechanical components, auxiliary contacts, and trip-unit settings according to the manufacturer’s maintenance instructions. Any abnormal heating, unusual operating behavior, or repeated tripping should be investigated before the breaker is returned to service.

Protection settings should be documented and reviewed whenever the distribution network changes. Changes to transformers, cables, busbars, or downstream loads can affect fault levels and protection coordination.

Because circuit breakers are safety-critical devices, installation, testing, and maintenance should be performed by qualified personnel following the manufacturer’s instructions and applicable electrical regulations.

Conclusion

The Schneider Electric NS800N Circuit Breaker is an 800 A low-voltage distribution protection device from the ComPacT NS family. Its N-class configuration provides 50 kA ultimate breaking capacity at 380/415 V AC and supports applications requiring high-current circuit protection and isolation.

The platform is available in multiple pole arrangements, mounting types, and trip-unit configurations. For procurement and replacement, the complete product configuration must be confirmed rather than relying on the NS800N designation alone.

With correct selection, installation, and protection coordination, the NS800N can serve as an important component in industrial switchboards, main distribution systems, and other low-voltage electrical installations.