• Schneider NW16H1 Circuit Breaker
  • Schneider NW16H1 Circuit Breaker
  • Schneider NW16H1 Circuit Breaker
  • Schneider NW16H1 Circuit Breaker
Product Overview The Schneider Electric NW16H1 MasterPact Circuit VBreaker is a low-voltage air circuit breaker designed for high-capacity power distribution and electrical protection systems. It belong……
Schneider NW16H1 Circuit Breaker
  • Schneider
  • NW16H1
  • Circuit Breaker
  • France
  • 439 x 441 x 395 mm
  • 90 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 3

Our advantage

Schneider NW16H1 Circuit Breaker

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Schneider NW16H1 Circuit Breaker

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Schneider NW16H1 Circuit Breaker

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Schneider NW16H1 Circuit Breaker

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Schneider Electric NW16H1 MasterPact Circuit VBreaker is a low-voltage air circuit breaker designed for high-capacity power distribution and electrical protection systems. It belongs to the MasterPact NW series and is intended for industrial facilities, commercial buildings, and electrical infrastructure where reliable switching and short-circuit protection are essential.

The NW16H1 is built around a 1600 A frame rating and a three-pole configuration. Its H1 performance class provides a rated ultimate short-circuit breaking capacity of 65 kA at 440 V AC. The device supports operating voltages up to 690 V AC, making it suitable for appropriately engineered low-voltage distribution networks.

The drawout configuration allows the circuit breaker to be withdrawn from its cradle for inspection, maintenance, or replacement without removing the complete switchboard assembly. This arrangement is particularly useful in installations where maintenance access and equipment availability are important.

The specific configuration covered here is identified as a three-pole drawout circuit breaker without a control unit. This distinction is important when planning a complete protection system. The breaker frame and its mechanical switching functions should not be confused with a fully configured protection assembly containing a Micrologic trip unit and all required accessories.

The NW16H1 is intended for use in main distribution boards, industrial switchgear, generator distribution systems, and other high-current electrical installations. Correct selection requires an assessment of rated current, system voltage, prospective short-circuit current, protection coordination, and installation requirements.

Technical Specifications

Parameter Specification
Brand Schneider Electric
Product Series MasterPact NW
Model NW16H1
Product Type Air Circuit Breaker
Frame Rating 1600 A
Number of Poles 3P
Performance Class H1
Mounting Configuration Drawout
Control Unit Not included in the specified configuration
Rated Operational Voltage Up to 690 V AC, 50/60 Hz
Rated Current 1600 A at 40°C
Ultimate Breaking Capacity (Icu) 65 kA at 440 V AC
Service Breaking Capacity (Ics) 65 kA at 440 V AC
Short-Time Withstand Current (Icw) 65 kA for 1 second
Rated Insulation Voltage (Ui) 1000 V AC
Impulse Withstand Voltage (Uimp) 12 kV
Short-Circuit Making Capacity (Icm) 143 kA at 440 V AC
Selectivity Category Category B
Suitability for Isolation Yes, according to IEC 60947-2
Dimensions 439 × 441 × 395 mm
Weight 90 kg
Protection Degree IP30
Applicable Standards EN/IEC 60947-1, EN/IEC 60947-2

Specifications refer to the identified three-pole drawout configuration. Confirm the exact nameplate, control-unit arrangement, and accessory list before ordering.

Function and Working Principle

The NW16H1 is designed to connect, carry, and interrupt electrical current in a low-voltage power distribution system. It provides switching functions under normal operating conditions and interrupts fault current when used with the appropriate protection and trip-unit configuration.

1. Normal Current Switching

During normal operation, the circuit breaker maintains an electrical connection between the incoming power source and the downstream distribution circuit.

Its main contacts carry the operating current. The 1600 A frame rating identifies its current class, while the installation’s actual continuous current must remain within the applicable equipment and environmental limits.

2. Overload and Short-Circuit Protection

Circuit protection is provided through the appropriate control and trip-unit arrangement. A compatible protection unit monitors electrical conditions and initiates a trip when configured protection thresholds are exceeded.

For a complete installation, engineers must select the correct protection functions and settings according to the load, cable ratings, transformer characteristics, and system coordination requirements.

Because the specified configuration is without a control unit, buyers should not assume that all electronic protection functions are included in the supplied breaker.

3. Arc Interruption

When the breaker opens under load or fault conditions, an electrical arc may form between the separating contacts. The air circuit breaker uses its arc-control structure to manage and extinguish the arc.

Its H1 performance class provides a defined short-circuit interruption capability. The system fault level must be calculated to confirm that the breaker is suitable for the installation.

4. Drawout Mechanism

The drawout design allows the breaker to be moved between its operating and disconnected positions within a compatible cradle.

This arrangement supports maintenance access and facilitates replacement work. The breaker, cradle, electrical connections, mechanical interlocks, and auxiliary circuits must all be compatible.

5. Isolation and Maintenance

The MasterPact NW16H1 is suitable for isolation in accordance with the applicable IEC requirements. Isolation procedures must still follow the installation’s safety rules, including upstream power isolation, verification of the absence of voltage, and lockout/tagout procedures.

Role in Industrial Power Distribution Systems

The NW16H1 can serve as a main or feeder circuit breaker in a low-voltage distribution network. Its role depends on the switchgear design and the protection coordination strategy.

Main Distribution Protection

In a main distribution board, a circuit breaker may protect the outgoing distribution system from overload and short-circuit conditions. A 1600 A frame can be used in installations where the calculated load and protection requirements are appropriate.

Feeder Circuit Protection

The breaker may also be installed on a high-current feeder supplying downstream panels, production areas, or large electrical loads.

Protection settings should coordinate with downstream breakers so that a fault is isolated as close as possible to its source without unnecessarily interrupting the entire distribution system.

Generator and Transformer Distribution

In generator and transformer applications, circuit breakers provide switching and protection between electrical sources and distribution equipment.

Selection must account for source characteristics, available fault current, voltage, neutral and grounding arrangements, and the required operating sequence.

Switchgear Integration

The drawout configuration is designed for use with a compatible switchgear cradle. Correct mechanical dimensions, primary connections, secondary connections, and interlocks are essential for safe operation.

Industrial Applications

1. Manufacturing Facilities

Large manufacturing plants use high-current distribution equipment to supply production lines, motors, heating systems, and auxiliary services. The NW16H1 may be used in an appropriately rated main or feeder distribution position.

2. Commercial Buildings

Large commercial facilities require dependable distribution protection for central electrical rooms, HVAC systems, lighting distribution, and other major loads.

The breaker can be considered where the system current and short-circuit requirements match its ratings.

3. Data Centers

Data centers rely on coordinated low-voltage distribution equipment to supply servers, cooling systems, UPS equipment, and supporting infrastructure.

A suitable circuit breaker can form part of the distribution protection architecture. Selection must consider fault levels, selectivity, operating continuity, and the complete protection-unit configuration.

4. Power Generation Facilities

Generator installations require switching and protection equipment that can handle the electrical characteristics of the source and the connected distribution network.

The NW16H1 may be used in suitable low-voltage distribution arrangements after a detailed review of generator fault contribution and protection coordination.

5. Industrial Utility Systems

Water treatment plants, processing facilities, and large utility installations use high-capacity switchgear to distribute power to pumps, compressors, and auxiliary systems.

A 1600 A circuit breaker can provide a switching and protection position where its ratings and configuration meet the system design.

Installation and System Integration

Correct installation is essential for the safe operation of a high-current air circuit breaker.

1. Verify Electrical Ratings

Before installation, confirm that the system voltage, rated current, and prospective short-circuit current are compatible with the NW16H1.

The 65 kA breaking capacity at 440 V AC must be evaluated against the calculated fault level at the installation point. Do not select a breaker based solely on its 1600 A frame rating.

2. Confirm the Drawout Cradle

The drawout breaker must be installed in a compatible cradle. Verify the model, pole arrangement, connection layout, mechanical dimensions, and interlock arrangement.

Do not attempt to install a breaker into an unverified cradle simply because the external dimensions appear similar.

3. Check the Control Unit

The specified product configuration is without a control unit. Before commissioning, confirm which protection unit is required and whether it is supplied separately.

The selected protection unit must support the required overload, short-circuit, and ground-fault functions where applicable. Its sensor rating and settings must be appropriate for the installation.

4. Inspect Electrical Connections

Check primary terminals, busbar connections, secondary wiring, auxiliary contacts, and grounding arrangements. Connections must be installed and tightened according to the manufacturer’s instructions.

Poor connections can cause overheating, voltage drop, and equipment damage.

5. Verify Mechanical and Electrical Interlocks

The drawout mechanism and associated interlocks must operate correctly. Verify the operating, test, and disconnected positions where applicable.

Interlocks must not be bypassed to force the breaker into a position or operating state.

6. Perform Commissioning Tests

Before energizing the switchgear, perform the required mechanical inspections and electrical tests. Verify the trip-unit configuration, protection settings, auxiliary circuits, and operating mechanism.

Testing and commissioning should be carried out by qualified personnel using approved procedures and suitable test equipment.

Compatible System Components

The NW16H1 is part of a larger low-voltage distribution assembly. The following components may be relevant to a complete installation.

Component Function Integration Considerations
Compatible MasterPact NW cradle Supports the drawout breaker Must match the breaker frame and pole configuration
Micrologic control unit Provides configured protection and trip functions Not included in the specified configuration; select separately
Current sensors Provide current measurement for protection Must match the control-unit arrangement
Auxiliary contacts Provide breaker status signals Verify contact type and wiring requirements
Closing and opening coils Support electrical operation Confirm rated control voltage and accessory compatibility
Electrical operating mechanism Supports remote operation where configured Verify the exact accessory configuration
Switchgear busbars Carry current through the distribution assembly Check current rating, connection dimensions, and temperature limits
Protection relay or monitoring system Supports system-level protection and monitoring Coordinate settings and signals with the breaker arrangement
Low-voltage distribution panel Houses and connects the breaker Must be designed for the breaker dimensions, weight, and clearances

The presence of these components in the table does not mean they are included with the NW16H1. Check the actual bill of materials and product configuration before procurement.

Alternative Models and Replacement Considerations

The MasterPact NW range includes different frame sizes and performance levels. A replacement must be selected according to electrical and mechanical requirements.

Related Model General Difference Replacement Consideration
MasterPact NW16N1 1600 A frame with N1 performance class Lower breaking-capacity class; verify fault-level requirements
MasterPact NW16H1 1600 A frame with H1 performance class Reference model for this article
MasterPact NW16H2 1600 A frame with higher H2 breaking performance Verify exact voltage and breaking-capacity requirements
MasterPact NW16H3 1600 A frame with H3 performance class Higher performance class; check compatibility and switchgear arrangement
MasterPact MTZ2 16 Newer MasterPact product family Requires detailed mechanical, electrical, and protection-system assessment

A replacement decision should consider:

  • Rated current and frame size.
  • Number of poles.
  • Rated operational voltage.
  • Ultimate and service breaking capacities.
  • Short-time withstand current.
  • Fixed or drawout mounting arrangement.
  • Cradle and connection compatibility.
  • Control-unit and sensor configuration.
  • Auxiliary contacts and operating accessories.
  • Switchgear dimensions and installation clearances.
  • Protection coordination and commissioning requirements.

A breaker with the same nominal current rating is not automatically a direct replacement. Changes to the cradle, busbar connections, control wiring, protection settings, or switchgear design may be necessary.

Key Advantages

High Current Capacity

The 1600 A frame rating makes the NW16H1 suitable for high-current distribution applications when correctly selected for the system.

H1 Breaking Performance

Its H1 performance class provides a rated ultimate short-circuit breaking capacity of 65 kA at 440 V AC.

Drawout Construction

The drawout design supports inspection, maintenance, and replacement activities without removing the complete switchgear assembly.

Three-Pole Configuration

The three-pole arrangement is intended for compatible three-phase distribution systems.

Isolation Capability

The device is suitable for isolation under the applicable IEC requirements, supporting maintenance and switching procedures.

Industrial Switchgear Integration

The MasterPact NW design supports integration into appropriately engineered low-voltage distribution assemblies.

Technical FAQs

1. What is the Schneider Electric NW16H1?

The NW16H1 is a MasterPact NW air circuit breaker with a 1600 A frame rating and H1 short-circuit performance class. The configuration discussed here is a three-pole drawout version without a control unit.

2. What is the rated current of the NW16H1?

Its rated current is 1600 A at 40°C. Actual operating conditions and installation requirements must be considered when applying this rating.

3. What is its short-circuit breaking capacity?

The H1 version has a rated ultimate short-circuit breaking capacity of 65 kA at 440 V AC. Confirm the applicable rating at the actual system voltage before installation.

4. Is the NW16H1 a three-pole or four-pole breaker?

The product configuration covered here is three-pole. Other NW16H1 variants are available with different pole arrangements, so the full product reference must be checked.

5. Does this version include a Micrologic trip unit?

No. The specified configuration is listed without a control unit. The required protection unit and accessories must be confirmed separately.

6. What does the drawout design mean?

A drawout breaker can be moved within a compatible cradle between designated operating and disconnected positions. This supports maintenance and replacement without removing the entire switchgear assembly.

7. What is the insulation voltage?

The rated insulation voltage is 1000 V AC. The rated impulse withstand voltage is 12 kV.

8. What are the dimensions and weight?

The listed dimensions are 439 × 441 × 395 mm, and the net weight is 90 kg. Verify handling and lifting requirements before installation.

9. Can the NW16H1 replace an NW16H2 or NW16H3?

Not automatically. These models have different short-circuit performance classes. The replacement must meet the system’s calculated fault level and be mechanically and electrically compatible with the switchgear.

10. What should be checked before purchasing?

Verify the complete model reference, three-pole drawout configuration, control-unit status, cradle compatibility, nameplate ratings, mechanical condition, and included accessories. For critical installations, request suitable inspection and test documentation.

Procurement and Maintenance Recommendations

When purchasing the Schneider Electric NW16H1, verify that the offered unit matches the required 1600 A, three-pole, H1, drawout configuration. Pay particular attention to whether the product is supplied with a control unit, cradle, operating mechanism, auxiliary contacts, and other accessories.

For used or surplus equipment, inspect the nameplate, contact condition, arc-control components, operating mechanism, primary connections, and secondary terminals. Confirm whether the breaker has been tested and whether any maintenance records are available.

During maintenance, follow the manufacturer’s inspection and service procedures. Check contact wear, mechanical operation, connection condition, interlocks, and protection-unit settings where fitted. Do not perform internal work or insulation testing without following the prescribed safety procedures.

Because the NW16H1 is a high-current switchgear component, installation, testing, and commissioning should be performed by qualified electrical personnel. Correct protection coordination and compatibility with the existing cradle are essential for safe operation.

Conclusion

The Schneider Electric NW16H1 MasterPact Air Circuit Breaker is a 1600 A, three-pole drawout circuit breaker designed for high-capacity low-voltage power distribution. Its H1 performance class provides a 65 kA rated ultimate breaking capacity at 440 V AC, while its drawout construction supports maintenance and replacement in compatible switchgear assemblies.

The specific configuration described here is supplied without a control unit. Buyers and engineers should therefore verify the required protection unit, cradle, operating accessories, and electrical ratings before procurement. Accurate configuration matching is essential when maintaining or upgrading industrial power distribution systems.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501